Changes for page 03 Software

Last modified by Jim on 2025/01/10 15:20

From version 24.1
edited by Jim
on 2023/10/09 16:56
Change comment: There is no comment for this version
To version 41.1
edited by Jim
on 2025/01/10 15:20
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -1,48 +1,23 @@
1 -|=(% style="width: 179px;" %)**Software**|=(% style="width: 126px;" %)Version|=(% style="width: 119px;" %)Download|=(% style="width: 652px;" %)Description
2 -|=(% style="width: 179px;" %)**PLC Editor2**|(% style="width:126px" %)2.3.247|(% style="width:119px" %)[[Link>>https://ftp.we-con.com.cn/Download/WIKI/LX6V%20PLC/Software/Wecon%20PLC%20Editor2%20setup%20Ver2.3.47.23090402.zip]]|(% style="width:652px" %)(((
1 +|=**Software**|=Version|=Download|=Description
2 +|=**PLC Editor2**|2.4.41(20241220)|[[Link>>url:https://ftp.we-con.com.cn/Download/WIKI/LX6V%20PLC/Software/Wecon%20PLC%20Editor2%20setup%202.4.41.24122004.zip]]|(((
3 3  Software Update:
4 4  
5 -* Added 6V pulse axis function;
6 - Added 6V axis group function;
7 - Added 6V function to read PLC CPU temperature and occupancy rate;
8 - Added 5V PLC identification code function.
9 - Added LX1V model.
10 -)))
5 +* Added LX6S series
11 11  
7 +New features
12 12  
13 -|=(% style="width: 179px;" %)**Software**|=(% style="width: 126px;" %)Version|=(% style="width: 119px;" %)Download|=(% style="width: 652px;" %)Description
14 -|=(% style="width: 179px;" %)**PLC Editor2**|(% style="width:126px" %)2.1.232(Beta)|(% style="width:119px" %)[[Link>>https://ftp.we-con.com.cn/Download/WIKI/LX5V%20PLC/Software/Wecon%20PLC%20Editor2%20setup%20Ver2.3.2_1031_1900.zip]]|(% style="width:652px" %)(((
15 -Software Update:
16 -
17 -* Add the following instruction: 
18 - Clock operation: TON, TONR, TOF, TP
19 - Data processing: STDEV, DSTDEV
20 - Other instructions: CRC_XMODEM, LRC
21 - Floating-point operations: CHKFLT, DEMOD
22 - Convenience instructions: MOVAVG, FOLAG, RCD
23 -* Modify PWM command description
9 +* Added axis online debug function.
10 +* Optimize variable creation
11 +* Other bugs fixed.
24 24  )))
25 25  
26 26  |=(% style="width: 179px;" %)**Software**|=(% style="width: 126px;" %)Version|=(% style="width: 119px;" %)Download|=(% style="width: 652px;" %)Description
27 -|=(% style="width: 179px;" %)**PLC Editor2**|(% style="width:126px" %)2.1.203|(% style="width:119px" %)[[Link>>https://ftp.we-con.com.cn/Download/Software/Wecon%20PLC%20Editor2%20setup%202.1.203_R1_0729.zip]]|(% style="width:652px" %)(((
15 +|=(% style="width: 179px;" %)**PLC Editor2**|(% style="width:126px" %)2.4.34(20240926)|(% style="width:119px" %)[[Link>>https://ftp.we-con.com.cn/Download/WIKI/LX5V%20PLC/Software/Wecon%20PLC%20Editor2%20setup%202.4.34.24092602.zip]]|(% style="width:652px" %)(((
28 28  Software Update:
29 29  
30 -* Add monitor edit function
31 -* Add ethernet communication function(Model with -N)
32 -* Add IP search function(Model with -N)
33 -* Add PLCLINK function (Optimize and upgrade the previous 3V N:N protocol)
34 -* Add batch search and replace function of soft components
35 -* Add 3V software interface in 5V software
36 -* Support COM1 user define protocol
37 -* Add DSZR/BCC/MAX/MIN instruction.
38 -* New 5V PLC firmware: V2.013 Update:
39 -* Add multiple origin regression instruction functions of DSZR;
40 -* Support COM1 user define protocol;
41 -* Add PLCLINK function;
42 -* Add acceleration and deceleration (trapezoidal and S-shaped) time division function;
43 -* Add spiral interpolation instruction;
44 -* Add the hardware configuration table function.
45 -* Add BCC/MAX/MIN instruction;
46 -* Add the function of direction delay of interpolation instruction;
47 -* Add monitor edit function.
18 +* Fixed issue where the range and description of the K parameter in the SOCTCP instruction were inconsistent.
19 +* Fixed issue where the compiler did not report an error when a T register was called twice after using the TON or TOF instruction.
20 +* Fixed issue where the software would freeze when deleting the last section of a program after copying a 3V program to a 5V PLC.
21 +* Fixed the issue where the PLC software would lag during online monitoring of the module
22 +* Fixed issue where the 6V project took a long time to close after switching from monitoring to editing mode.
48 48  )))