Changes for page 03 Software
Last modified by Jim on 2025/01/10 15:20
From version 40.1
edited by Devin Chen
on 2024/10/22 17:42
on 2024/10/22 17:42
Change comment:
There is no comment for this version
Summary
-
Page properties (2 modified, 0 added, 0 removed)
Details
- Page properties
-
- Author
-
... ... @@ -1,1 +1,1 @@ 1 -XWiki. DevinChen1 +XWiki.Jim - Content
-
... ... @@ -1,49 +1,46 @@ 1 1 |=(% style="width: 179px;" %)**Software**|=(% style="width: 126px;" %)Version|=(% style="width: 119px;" %)Download|=(% style="width: 652px;" %)Description 2 -|=(% style="width: 179px;" %)**PLC Editor2**|(% style="width:126px" %)2. 4.34(20240926)|(% style="width:119px" %)[[Link>>https://ftp.we-con.com.cn/Download/WIKI/LX5V%20PLC/Software/Wecon%20PLC%20Editor2%20setup%202.4.34.24092602.zip]]|(% style="width:652px" %)(((2 +|=(% style="width: 179px;" %)**PLC Editor2**|(% style="width:126px" %)2.3.118(20240103)|(% style="width:119px" %)[[Link>>https://ftp.we-con.com.cn/Download/WIKI/LX5V%20PLC/Software/Wecon%20PLC%20Editor2%20setup%20Ver2.3.118.24010301.zip]]|(% style="width:652px" %)((( 3 3 Software Update: 4 4 5 -* Fixed issue where the range and description of the K parameter in the SOCTCP instruction were inconsistent. 6 -* Fixed issue where the compiler did not report an error when a T register was called twice after using the TON or TOF instruction. 7 -* Fixed issue where the software would freeze when deleting the last section of a program after copying a 3V program to a 5V PLC. 8 -* Fixed the issue where the PLC software would lag during online monitoring of the module 9 -* Fixed issue where the 6V project took a long time to close after switching from monitoring to editing mode. 10 -))) 5 +* Fixed 5S high-speed input problem; 6 +* Fixed the problem that the conversion failed when downloading some 6V ladder diagrams; 11 11 8 +New features 12 12 10 +* Add LX6S model; 11 +* Support EtherCAT remote IO module; 12 +* Support LX6S axis group and local pulse axis; 13 +* Supporrt LX6 series 4AD/4DA module 14 +))) 15 + 13 13 |=(% style="width: 179px;" %)**Software**|=(% style="width: 126px;" %)Version|=(% style="width: 119px;" %)Download|=(% style="width: 652px;" %)Description 14 -|=(% style="width: 179px;" %)**PLC Editor2**|(% style="width:126px" %)2. 4.23(20240702)|(% style="width:119px" %)[[Link>>https://ftp.we-con.com.cn/Download/WIKI/LX6V%20PLC/Software/Wecon%20PLC%20Editor2%20setup%202.4.23.24070201.zip]]|(% style="width:652px" %)(((17 +|=(% style="width: 179px;" %)**PLC Editor2**|(% style="width:126px" %)2.3.66(20231113)|(% style="width:119px" %)[[Link>>https://ftp.we-con.com.cn/Download/WIKI/LX6V%20PLC/Software/Wecon%20PLC%20Editor2%20setup%20Ver2.3.66.23111301.zip]]|(% style="width:652px" %)((( 15 15 Software Update: 16 16 17 -* Fixed Ethernet search device issue; 18 -* Fixed the issue that the imported XML file would crash; 20 +* Optimize 6V ladder diagram loading speed; 21 +* Optimize communication interface stuck problem; 22 +* Optimize the response time of the software when opening a large project; 23 +* Some bug fixes; 19 19 20 20 New features 21 21 22 -* Added 6V USB download function 23 -* Added FB/FC import and export function 24 -* Cancel EN/ENO of function block 25 -* Added EtherCAT distributed clock function 26 -* Added EtherCAT & Expansion module scanning function 27 -* LX5 series add LX5V-4TC, LX5V-2TC2ADV BD module 27 +* 5V PWM instructions increased to 16 channels (8*1μs + 8*100μs); 28 +* Added 6V global variable MODBUS address mapping; 29 +* The maximum array length limit of 6V is increased from 49 to 99; 30 +* Added 6V comment editing function; 31 +* Add a new array using variables as subscripts. 28 28 ))) 29 29 30 30 |=(% style="width: 179px;" %)**Software**|=(% style="width: 126px;" %)Version|=(% style="width: 119px;" %)Download|=(% style="width: 652px;" %)Description 31 -|=(% style="width: 179px;" %)**PLC Editor2**|(% style="width:126px" %)2.3.2 18(20240325)|(% style="width:119px" %)[[Link>>https://ftp.we-con.com.cn/Download/WIKI/LX5V%20PLC/Software/Wecon%20PLC%20Editor2%20setup-240325.exe]]|(% style="width:652px" %)(((35 +|=(% style="width: 179px;" %)**PLC Editor2**|(% style="width:126px" %)2.3.247|(% style="width:119px" %)[[Link>>https://ftp.we-con.com.cn/Download/WIKI/LX6V%20PLC/Software/Wecon%20PLC%20Editor2%20setup%20Ver2.3.47.23090402.zip]]|(% style="width:652px" %)((( 32 32 Software Update: 33 33 34 -* Added axis debug function; 35 -* Added variable copy and paste function; 38 +* Added 6V pulse axis function; 39 +* Added 6V axis group function; 40 +* Added 6V function to read PLC CPU temperature and occupancy rate; 41 +* Added 5V PLC identification code function; 42 +* Added LX1V model. 43 +))) 36 36 37 -New features 38 38 39 -* Support MC_TOUCHPROBE 40 -* Add three EtherCAT related FB: 41 -** ETC_READPARAMETER_COE 42 -** ETC_WRITEPARAMETER_COE 43 -** IODVETHERCAT 44 -* Add four built-in FC: 45 -** ROUND 46 -** ROUNDUP 47 -** CEIL 48 -** FLOOR 49 -))) 46 +