Why can't the motor rotate normally?
Last modified by Jim on 2023/11/30 16:29
Question | Reason | Solution |
---|---|---|
Motor doesn't rotate | Parameter setting error. | (1) Check whether the control mode P0-01 is correct. (2) Check whether servo are in run status, if not, check P06-02 to P06-04. (3) Check whether command source selection is correct. |
No input command. | (1) Check whether PLC send pulses normally and whether servo receive pulses. (2) Check whether analog input is in normally range. | |
Mechanically blocked or not connected | (1) Check whether the load is connected correctly. (2) Check whether load and mechanical stuck. (3) Check whether brake device is release. | |
Motor only rotate in one direction | Control command didn't change direction | Please check whether control command changes the direction. |
Direction pin burned | If JOG function works normally when forward rotate and reverse rotate, direction pin burned, please contact technical engineer. |