Changes for page 04 Wiring

Last modified by Jim on 2024/07/30 10:16

From version 118.6
edited by Joey
on 2022/06/18 21:59
Change comment: Update document after refactoring.
To version 118.7
edited by Stone Wu
on 2022/07/05 11:11
Change comment: There is no comment for this version

Summary

Details

Page properties
Author
... ... @@ -1,1 +1,1 @@
1 -XWiki.Joey
1 +XWiki.Stone
Content
... ... @@ -30,12 +30,12 @@
30 30  
31 31  Table 4-1 The name and function of VD2A servo drive main circuit terminal
32 32  
33 -**VD2B servo drive main circuit terminal distribution**
33 +**VD2B servo drive (220V) main circuit terminal distribution**
34 34  
35 35  (% style="text-align:center" %)
36 36  [[image:Wecon VD2 SA Series Servo Drives Manual (Full V1.1)_html_17042d8c7761266a.gif]]
37 37  
38 -Figure 4-2 VD2B servo drive main circuit terminal distribution
38 +Figure 4-2 VD2B servo drive (220V) main circuit terminal distribution
39 39  
40 40  (% class="table-bordered" %)
41 41  |(% style="text-align:center; vertical-align:middle" %)**Terminal number**|(% style="text-align:center; vertical-align:middle" %)**Terminal name**|(% style="text-align:center; vertical-align:middle" %)**Terminal function**
... ... @@ -60,8 +60,34 @@
60 60  |(% style="text-align:center; vertical-align:middle" %)W
61 61  |(% style="text-align:center; vertical-align:middle" %)Ground terminal|(% style="text-align:center; vertical-align:middle" %)Ground terminal|Grounding treatment of the servo drive.
62 62  
63 -Table 4-2 The name and function of VD2B servo drive main circuit terminal
63 +Table 4-2 The name and function of VD2B servo drive (220V) main circuit terminal
64 64  
65 +**VD2B servo drive (380V) main circuit terminal distribution**
66 +
67 +[[image:image-20220705111045-1.jpeg]]
68 +
69 +Figure 4-3 VD2B servo drive (380V) main circuit terminal distribution
70 +
71 +|**Terminal number**|**Terminal name**|**Terminal function**
72 +|L1|(% rowspan="3" %)Power input terminal|(% rowspan="3" %)Three-phase 380V AC input is connected to L1, L2, L3;
73 +|L2
74 +|L3
75 +|L1C|(% rowspan="2" %)Control power input terminal|(% rowspan="2" %)Single-phase 380V AC input is connected to L1C and L2C.
76 +|L2C
77 +|P+|(% rowspan="3" %)Braking resistor terminal|(% rowspan="3" %)(((
78 +Use internal braking resistor: short-circuit C and D.
79 +
80 +Use external braking resistor: Please disconnect the short wire between C and D, and then connect the external braking resistor between P+ and C.
81 +)))
82 +|C
83 +|D
84 +|U|(% rowspan="3" %)Motor power line terminal|(% rowspan="3" %)Connect with the U, V and W of motor to power the motor.
85 +|V
86 +|W
87 +|Ground terminal|Ground terminal|Grounding treatment of servo drive.
88 +
89 +Table 4-3 The name and function of VD2B servo drive (380V) main circuit terminal
90 +
65 65  **VD2F servo drive main circuit terminal distribution**
66 66  
67 67  (% style="text-align:center" %)
image-20220705111045-1.jpeg
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Stone
Size
... ... @@ -1,0 +1,1 @@
1 +379.0 KB
Content