@@ -88,36 +88,12 @@ |
88 |
88 |
|
89 |
89 |
Table 4-3 The name and function of VD2B servo drive (380V) main circuit terminal |
90 |
90 |
|
91 |
|
-(% style="text-align:center" %) |
92 |
|
-((( |
93 |
|
-(% style="display:inline-block" %) |
94 |
|
-[[Figure 4-4 VD2C servo drive (380V) main circuit terminal distribution>>image:1721014980046-575.png]] |
95 |
|
-))) |
96 |
|
- |
97 |
|
-|=**Terminal number**|=**Terminal name**|=**Terminal function** |
98 |
|
-|L1|(% rowspan="3" %)Power input terminal|(% rowspan="3" %)Three-phase 380V AC input is connected to L1, L2, L3; |
99 |
|
-|L2 |
100 |
|
-|L3 |
101 |
|
-|L1C|(% rowspan="2" %)Control power input terminal|(% rowspan="2" %)Single-phase 380V AC input is connected to L1C and L2C. |
102 |
|
-|L2C |
103 |
|
-|P+|(% rowspan="3" %)Braking resistor terminal|(% rowspan="3" %)((( |
104 |
|
-Use internal braking resistor: short-circuit C and D. |
105 |
|
- |
106 |
|
-Use external braking resistor: Please disconnect the short wire between C and D, and then connect the external braking resistor between P+ and C. |
107 |
|
-))) |
108 |
|
-|C |
109 |
|
-|D |
110 |
|
-|U|(% rowspan="3" %)Motor power line terminal|(% rowspan="3" %)Connect with the U, V and W of motor to power the motor. |
111 |
|
-|V |
112 |
|
-|W |
113 |
|
-|Ground terminal|Ground terminal|Grounding treatment of servo drive. |
114 |
|
- |
115 |
115 |
**VD2F servo drive main circuit terminal distribution** |
116 |
116 |
|
117 |
117 |
(% style="text-align:center" %) |
118 |
118 |
((( |
119 |
119 |
(% class="wikigeneratedid img-thumbnail" style="display:inline-block" %) |
120 |
|
-[[**Figure 4-5 VD2F servo drive main circuit terminal distribution**>>image:Wecon VD2 SA Series Servo Drives Manual (Full V1.1)_html_6dd68f214c0f9f79.gif||id="IWeconVD2SASeriesServoDrivesManual28FullV1.129_html_6dd68f214c0f9f79.gif"]] |
|
96 |
+[[**Figure 4-4 VD2F servo drive main circuit terminal distribution**>>image:Wecon VD2 SA Series Servo Drives Manual (Full V1.1)_html_6dd68f214c0f9f79.gif||id="IWeconVD2SASeriesServoDrivesManual28FullV1.129_html_6dd68f214c0f9f79.gif"]] |
121 |
121 |
))) |
122 |
122 |
|
123 |
123 |
(% class="table-bordered" %) |
... |
... |
@@ -137,7 +137,7 @@ |
137 |
137 |
|=(% style="text-align: center; vertical-align: middle; width: 160px;" %)W |
138 |
138 |
|=(% style="text-align: center; vertical-align: middle; width: 160px;" %)PE|(% style="text-align:center; vertical-align:middle; width:265px" %)Ground terminal|(% style="width:651px" %)Grounding treatment of the servo drive. |
139 |
139 |
|
140 |
|
-Table 4-5 The name and function of VD2F servo drive main circuit terminal |
|
116 |
+Table 4-4 The name and function of VD2F servo drive main circuit terminal |
141 |
141 |
|
142 |
142 |
== Power wiring == |
143 |
143 |
|