... ... @@ -3407,11 +3407,7 @@ 3407 3407 3408 3408 ① The deceleration point signal is invalid when starting homing, the reverse limit switch is not encountered 3409 3409 3410 -[[image:1748226908598-664.jpg]] 3411 3411 3412 -(% style="text-align:center" %) 3413 -[[image:1748226944069-933.jpg||height="472" width="600"]] 3414 - 3415 3415 When it starts to homing, HW=0, and it starts to homing at a reverse high speed. If it does not encounter the limit switch, after encountering the rising edge of HW, slow down and run at a reverse low speed. After encountering the falling edge of HW, reverse and run at a forward low speed, and stop at the first Z signal after encountering the rising edge of HW. 3416 3416 3417 3417