Changes for page 06 Operation
Last modified by Iris on 2025/07/23 15:49
From version 102.3
edited by xingzhi lin
on 2025/05/26 09:27
on 2025/05/26 09:27
Change comment:
There is no comment for this version
Summary
-
Page properties (2 modified, 0 added, 0 removed)
-
Attachments (0 modified, 0 added, 26 removed)
- 1748221916083-747.jpg
- 1748221977012-869.jpg
- 1748222014107-121.jpg
- 1748222027683-713.jpg
- 1748222134730-241.jpg
- 1748222168627-745.jpg
- 1748222190794-857.jpg
- 1748222203229-740.jpg
- 1748222259038-454.jpg
- 1748222356175-586.jpg
- 1748222408099-521.jpg
- 1748222430449-293.jpg
- 1748222448727-825.jpg
- 1748222469183-894.jpg
- 1748222485622-911.jpg
- 1748222509640-301.jpg
- 1748222603373-759.jpg
- 1748222658301-527.jpg
- 1748222676833-578.jpg
- 1748222740718-416.jpg
- 1748222745765-448.jpg
- 1748222754767-406.jpg
- 1748222776332-811.jpg
- 1748222790840-470.jpg
- 1748222807478-627.jpg
- 1748222822783-397.jpg
Details
- Page properties
-
- Author
-
... ... @@ -1,1 +1,1 @@ 1 -XWiki. lxz1 +XWiki.Mora - Content
-
... ... @@ -2551,9 +2551,8 @@ 2551 2551 **time** 2552 2552 )))|=**Default value**|=**Range**|=**Definition**|=**Unit** 2553 2553 |=P00-30|Shield multi-turn absolute encoder battery fault|Operation setting|Power on again|0|0 to 1|((( 2554 -0:Detect multi-turn absolute encoder battery under voltage, and battery low voltage fault 2555 - 2556 -1: (Not recommended) Shield multi-turn absolute motor battery failure alarm. Multi-turn absolute application may cause mechanical fault, only multi-turn absolute encoder motors is used as single-turn absolute 2554 +* 0:Detect multi-turn absolute encoder battery under voltage, and battery low voltage fault 2555 +* 1: (Not recommended) Shield multi-turn absolute motor battery failure alarm. Multi-turn absolute application may cause mechanical fault, only multi-turn absolute encoder motors is used as single-turn absolute 2557 2557 )))|- 2558 2558 2559 2559 This function is permitted when a multi-turn absolute encoder motor is used as a single-turn absolute and when it is confirmed that no mechanical failure will occur. ... ... @@ -2698,9 +2698,8 @@ 2698 2698 2699 2699 VDI_1 input level: 2700 2700 2701 -0: Low level 2702 - 2703 -1: High level 2700 +* 0: low level 2701 +* 1: high level 2704 2704 )))|- 2705 2705 |=P13-2|Virtual VDI_2 input value|Operation setting|Effective immediately|0|0 to 1|((( 2706 2706 When P06-07 is set to 1, DI_2 channel logic is control by this function code. ... ... @@ -2707,9 +2707,8 @@ 2707 2707 2708 2708 VDI_2 input level: 2709 2709 2710 -0: Low level 2711 - 2712 -1: High level 2708 +* 0: low level 2709 +* 1: high level 2713 2713 )))|- 2714 2714 |=P13-3|Virtual VDI_3 input value|Operation setting|Effective immediately|0|0 to 1|((( 2715 2715 When P06-10 is set to 1, DI_3 channel logic is control by this function code. ... ... @@ -2716,9 +2716,8 @@ 2716 2716 2717 2717 VDI_3 input level: 2718 2718 2719 -0: Low level 2720 - 2721 -1: High level 2716 +* 0: low level 2717 +* 1: high level 2722 2722 )))|- 2723 2723 |=P13-4|Virtual VDI_4 input value|Operation setting|Effective immediately|0|0 to 1|((( 2724 2724 When P06-13 is set to 1, DI_4 channel logic is control by this function code. ... ... @@ -2725,53 +2725,40 @@ 2725 2725 2726 2726 VDI_4 input level: 2727 2727 2728 -0: Low level 2729 - 2730 -1: High level 2724 +* 0: low level 2725 +* 1: high level 2731 2731 )))|- 2732 -|=P13-05((( 2733 -★ 2734 -)))|Virtual VDI_5 input value|Operation setting|Effective immediately|0|0 to 1|((( 2727 +|=P13-05☆|Virtual VDI_5 input value|Operation setting|Effective immediately|0|0 to 1|((( 2735 2735 When P06-16 is set to 1, DI_5 channel logic is control by this function code. 2736 2736 2737 2737 VDI_5 input level: 2738 2738 2739 -0: Low level 2740 - 2741 -1: High level 2732 +* 0: low level 2733 +* 1: high level 2742 2742 )))|- 2743 -|=P13-06((( 2744 -★ 2745 -)))|Virtual VDI_6 input value|Operation setting|Effective immediately|0|0 to 1|((( 2735 +|=P13-06☆|Virtual VDI_6 input value|Operation setting|Effective immediately|0|0 to 1|((( 2746 2746 When P06-19 is set to 1, DI_6 channel logic is control by this function code. 2747 2747 2748 2748 VDI_6 input level: 2749 2749 2750 -0: Low level 2751 - 2752 -1: High level 2740 +* 0: low level 2741 +* 1: high level 2753 2753 )))|- 2754 -|=P13-07((( 2755 -★ 2756 -)))|Virtual VDI_7 input value|Operation setting|Effective immediately|0|0 to 1|((( 2743 +|=P13-07☆|Virtual VDI_7 input value|Operation setting|Effective immediately|0|0 to 1|((( 2757 2757 When P06-22 is set to 1, DI_7 channel logic is control by this function code. 2758 2758 2759 2759 VDI_7 input level: 2760 2760 2761 -0: Low level 2762 - 2763 -1: High level 2748 +* 0: low level 2749 +* 1: high level 2764 2764 )))|- 2765 -|=P13-08((( 2766 -★ 2767 -)))|Virtual VDI_8 input value|Operation setting|Effective immediately|0|0 to 1|((( 2751 +|=P13-08☆|Virtual VDI_8 input value|Operation setting|Effective immediately|0|0 to 1|((( 2768 2768 When P06-25 is set to 1, DI_8 channel logic is control by this function code. 2769 2769 2770 2770 VDI_8 input level: 2771 2771 2772 -0: Low level 2773 - 2774 -1: High level 2756 +* 0: low level 2757 +* 1: high level 2775 2775 )))|- 2776 2776 2777 2777 Table 6-57 Virtual VDI parameters ... ... @@ -2778,7 +2778,7 @@ 2778 2778 2779 2779 (% class="box infomessage" %) 2780 2780 ((( 2781 -✎**Note: **“ ★” means VD2Fand VD2Lservo drive does not support the function code .2764 +✎**Note: **“☆” means VD2F servo drive does not support the function code . 2782 2782 ))) 2783 2783 2784 2784 == Port filtering time == ... ... @@ -2812,30 +2812,26 @@ 2812 2812 |=P13-11|Communication VDO_1 output value|Operation setting|Effective immediately|0|0 to 1|((( 2813 2813 VDO_1 output level: 2814 2814 2815 -0: Low level 2816 - 2817 -1: High level 2798 +* 0: low level 2799 +* 1: high level 2818 2818 )))|- 2819 2819 |=P13-12|Communication VDO_2 output value|Operation setting|Effective immediately|0|0 to 1|((( 2820 2820 VDO_2 output level: 2821 2821 2822 -0: Low level 2823 - 2824 -1: High level 2804 +* 0: low level 2805 +* 1: high level 2825 2825 )))|- 2826 2826 |=P13-13|Communication VDO_3 output value|Operation setting|Effective immediately|0|0 to 1|((( 2827 2827 VDO_3 output level: 2828 2828 2829 -0: Low level 2830 - 2831 -1: High level 2810 +* 0: low level 2811 +* 1: high level 2832 2832 )))|- 2833 2833 |=P13-14|Communication VDO_4 output value|Operation setting|Effective immediately|0|0 to 1|((( 2834 2834 VDO_4 output level: 2835 2835 2836 -0: Low level 2837 - 2838 -1: High level 2816 +* 0: low level 2817 +* 1: high level 2839 2839 )))|- 2840 2840 2841 2841 Table 6-59 Communication control DO function parameters ... ... @@ -2878,871 +2878,3 @@ 2878 2878 ((( 2879 2879 ✎**Note:** It is advised to configure function codes for DO terminals in sequence to avoid errors. Please use the shielded overload protection fault detection function with caution, otherwise it will cause burn out the motor. 2880 2880 ))) 2881 - 2882 - 2883 -= Homing mode = 2884 - 2885 -The homing mode is used to find the mechanical origin and locate the positional relationship between the mechanical origin and the mechanical zero. 2886 - 2887 -Mechanical homing: A mechanically fixed position may correspond to a certain defined homing switch, or may correspond to the motor Z signal. 2888 - 2889 -Mechanical zero point: Mechanically absolute 0 position. 2890 - 2891 -After the homing, the stop position of the motor is the mechanical homing. By setting P10-08, the relationship between the mechanical homing and the mechanical zero can be set: 2892 - 2893 -Mechanical homing = Mechanical zero +P10-08 (homing offset) 2894 - 2895 -When P10-08=0, the mechanical homing coincides with the mechanical zero. 2896 - 2897 -== Control block diagram == 2898 - 2899 - 2900 -=== Homing mode related function codes === 2901 - 2902 -|Function code|Name|((( 2903 -Setting 2904 - 2905 -method 2906 -)))|((( 2907 -Effective 2908 - 2909 -time 2910 -)))|Default|Range|Definition|Unit 2911 -|P01-39|Homing start mode|((( 2912 -Stop 2913 - 2914 -settings 2915 -)))|((( 2916 -Immediately 2917 - 2918 -effective 2919 -)))|0|0 to 2|((( 2920 -0: Close 2921 - 2922 -1: The servo is powered ON and started after the first ON 2923 - 2924 -2: DI enable 2925 -)))|- 2926 - 2927 -|Function code|Name|((( 2928 -Setting 2929 - 2930 -method 2931 -)))|((( 2932 -Effective 2933 - 2934 -time 2935 -)))|Default|Range|Definition|Unit 2936 -|P01-40|Homing mode|((( 2937 -Stop 2938 - 2939 -settings 2940 -)))|((( 2941 -Immediately 2942 - 2943 -effective 2944 -)))|0|0 to 35|((( 2945 -0 ~~ 35 Homing mode; 2946 - 2947 -✎Note: VD2 currently does not support 15, 16, 31, 32 modes 2948 -)))|- 2949 - 2950 -|Function code|Name|((( 2951 -Setting 2952 - 2953 -method 2954 -)))|((( 2955 -Effective 2956 - 2957 -time 2958 -)))|Default|Range|Definition|Unit 2959 -|P01-41|High-speed search deceleration point signal velocity|((( 2960 -Running 2961 - 2962 -settings 2963 -)))|((( 2964 -Immediately 2965 - 2966 -effective 2967 -)))|300|1 to 3000|High-speed search deceleration point signal velocity in homing mode|rpm 2968 - 2969 -|Function code|Name|((( 2970 -Setting 2971 - 2972 -method 2973 -)))|((( 2974 -Effective 2975 - 2976 -time 2977 -)))|Default|Range|Definition|Unit 2978 -|P01-42〇|Low speed search homing signal speed|((( 2979 -Running 2980 - 2981 -settings 2982 -)))|((( 2983 -Immediately 2984 - 2985 -effective 2986 -)))|60|1 to 300|Low-speed search origin signal velocity in homing mode|rpm 2987 - 2988 -|Function code|Name|((( 2989 -Setting 2990 - 2991 -method 2992 -)))|((( 2993 -Effective 2994 - 2995 -time 2996 -)))|Default|Range|Definition|Unit 2997 -|P01-43〇|Homing acceleration and deceleration|((( 2998 -Running 2999 - 3000 -settings 3001 -)))|((( 3002 -Immediately 3003 - 3004 -effective 3005 -)))|50|1to1000|((( 3006 -Acceleration and deceleration in homing mode 3007 - 3008 -Time for speed acceleration from 0 to 1000rpm 3009 -)))|ms 3010 - 3011 -|Function code|Name|((( 3012 -Setting 3013 - 3014 -method 3015 -)))|((( 3016 -Effective 3017 - 3018 -time 3019 -)))|Default|Range|Definition|Unit 3020 -|P01-44〇|Homing timeout limited time|((( 3021 -Running 3022 - 3023 -settings 3024 -)))|((( 3025 -Immediately 3026 - 3027 -effective 3028 -)))|65535|100 to 65535|Homing timeout limited time|ms 3029 - 3030 -|Function code|Name|((( 3031 -Setting 3032 - 3033 -method 3034 -)))|((( 3035 -Effective 3036 - 3037 -time 3038 -)))|Default|Range|Definition|Unit 3039 -|P10-08〇|Multi-turn absolute encoder homing offset compensation|((( 3040 -Running 3041 - 3042 -settings 3043 -)))|((( 3044 -Immediately 3045 - 3046 -effective 3047 -)))|0|((( 3048 --2147483647~~ 3049 - 3050 -2147483646 3051 -)))|((( 3052 -P10-08 multi-turn absolute encoder homing offset compensation is used in conjunction with U0-56 multi-turn absolute encoder current position. 3053 - 3054 -When P10-6 is set to 1, the value of U0-56 is updated to P10-8. 3055 -)))|- 3056 - 3057 -== Introduction to homing mode == 3058 - 3059 -In the following figure, "H" represents P01-41 (high-speed search deceleration point signal speed), and "L" represents P01-42 (low-speed search homing signal speed). 3060 - 3061 - 3062 -(1) P01-40 =1 3063 - 3064 -Mechanical homing: Motor Z signal 3065 - 3066 -Deceleration point: Reverse limit switch (NOT) 3067 - 3068 -① The deceleration point signal is invalid when starting homing 3069 - 3070 -(% style="text-align:center" %) 3071 -[[image:1748221916083-747.jpg||height="347" width="600"]] 3072 - 3073 -When it starts to homing, NOT=0, it starts to homing at a high speed in the reverse direction. After encountering the rising edge of NOT, it decelerates and reverses the direction, runs at a low speed in the forward direction, and stops at the first Z signal after encountering the falling edge of NOT. 3074 - 3075 - 3076 -② The deceleration point signal is valid when starting homing 3077 - 3078 -(% style="text-align:center" %) 3079 -[[image:1748222134730-241.jpg||height="341" width="600"]] 3080 - 3081 -When starting to homing, NOT=1, it starts to homing at a direct forward low speed, and stops at the first Z signal after encountering the falling edge of NOT. 3082 - 3083 - 3084 - 3085 - 3086 - 3087 - 3088 -(2) P01-40=2 3089 - 3090 -Mechanical homing: Motor Z signal 3091 - 3092 -Deceleration point: Positive Limit Switch (POT) 3093 - 3094 -① The deceleration point signal is invalid when starting homing 3095 - 3096 -(% style="text-align:center" %) 3097 -[[image:1748222168627-745.jpg||height="334" width="600"]] 3098 - 3099 - 3100 -When it starts to homing, POT = 0, and it starts to homing at a forward high speed. After encountering the rising edge of POT, it decelerates and reverses, runs at a reverse low speed, and stops at the first Z signal after encountering the falling edge of POT. 3101 - 3102 - 3103 -② The deceleration point signal is valid when starting homing 3104 - 3105 -(% style="text-align:center" %) 3106 -[[image:1748222190794-857.jpg||height="337" width="600"]] 3107 - 3108 -POT=1 when start homing, run at low speed directly in the reverse direction, and stops at the first Z signal after the falling edge of POT. 3109 - 3110 - 3111 - 3112 -(3) P01-40=3 3113 - 3114 -Mechanical homing: Motor Z signal 3115 - 3116 -Deceleration point: Home switch (HW) 3117 - 3118 -① The deceleration point signal is invalid when starting homing 3119 - 3120 -(% style="text-align:center" %) 3121 -[[image:1748222203229-740.jpg||height="337" width="600"]] 3122 - 3123 - 3124 -When it starts to homing, HW=0. It starts to homing at a forward high speed. After encountering the rising edge of HW, it decelerates and reverses the direction. It runs at a reverse low speed. After encountering the falling edge of HW, it continues to run, and then stops when encountering the first Z signal. 3125 - 3126 - 3127 -② The deceleration point signal is valid when starting homing 3128 - 3129 -(% style="text-align:center" %) 3130 -[[image:1748222259038-454.jpg||height="337" width="600"]] 3131 - 3132 -When starting homing, HW=1, start homing at low speed in reverse directly, and stop at the first Z signal after encountering the falling edge of HW; 3133 - 3134 - 3135 - 3136 - 3137 - 3138 - 3139 - 3140 - 3141 - 3142 - 3143 - 3144 - 3145 - 3146 -(4) P01-40=4 3147 - 3148 -Mechanical homing: Motor Z signal 3149 - 3150 -Deceleration point: Home switch (HW) 3151 - 3152 -① The deceleration point signal is invalid when starting homing 3153 - 3154 -(% style="text-align:center" %) 3155 -[[image:1748222356175-586.jpg||height="337" width="600"]] 3156 - 3157 -HW=0 when starting to homing, directly start to homing at low speed, and stop at the first Z signal after encountering the rising edge of HW; 3158 - 3159 - 3160 -② The deceleration point signal is valid when starting homing 3161 - 3162 -(% style="text-align:center" %) 3163 -[[image:1748222408099-521.jpg||height="338" width="600"]] 3164 - 3165 - 3166 -When starting to homing, HW = 1, start to homing at a high speed in the reverse direction. After encountering the falling edge of HW, decelerate and reverse, run at a low speed in the forward direction, and stop at the first Z signal after encountering the rising edge of HW. 3167 - 3168 - 3169 - 3170 - 3171 - 3172 -(5) P01-40=5 3173 - 3174 -Mechanical homing: Motor Z signal 3175 - 3176 -Deceleration point: Home switch (HW) 3177 - 3178 -① The deceleration point signal is invalid when starting homing 3179 - 3180 -(% style="text-align:center" %) 3181 -[[image:1748222430449-293.jpg||height="337" width="600"]] 3182 - 3183 -When it starts to homing, HW = 0, and it starts to homing at a reverse high speed. After encountering the rising edge of HW, it decelerates and reverses the direction, runs at a forward low speed, and stops at the first Z signal after encountering the falling edge of HW. 3184 - 3185 - 3186 -② The deceleration point signal is valid when starting homing 3187 - 3188 -(% style="text-align:center" %) 3189 -[[image:1748222448727-825.jpg||height="337" width="600"]] 3190 - 3191 -When starting homing, HW=1, it will start homing directly at low speed, and the first Z signal after encountering the falling edge of HW will stop; 3192 - 3193 - 3194 - 3195 - 3196 - 3197 -(6) P01-40=6 3198 - 3199 -Mechanical homing: Motor Z signal 3200 - 3201 -Deceleration point: Home switch (HW) 3202 - 3203 -① The deceleration point signal is invalid when starting homing 3204 - 3205 -(% style="text-align:center" %) 3206 -[[image:1748222469183-894.jpg||height="337" width="600"]] 3207 - 3208 -When starting to homing, HW=0, directly reverse low speed starts to homing, and the first Z signal stops after encountering the rising edge of HW; 3209 - 3210 - 3211 -② The deceleration point signal is valid when starting homing 3212 - 3213 -(% style="text-align:center" %) 3214 -[[image:1748222485622-911.jpg||height="337" width="600"]] 3215 - 3216 -When starting to homing, HW = 1, start to homing at a forward high speed, after encountering the falling edge of HW, decelerate and reverse, run at a reverse low speed, and stop at the first Z signal after encountering the rising edge of HW. 3217 - 3218 - 3219 - 3220 - 3221 - 3222 -(7) P01-40=7 3223 - 3224 -Mechanical homing: Motor Z signal 3225 - 3226 -Deceleration point: Home switch (HW) 3227 - 3228 -① The deceleration point signal is invalid when starting homing, the forward limit switch is not encountered 3229 - 3230 -(% style="text-align:center" %) 3231 -[[image:1748222509640-301.jpg||height="405" width="600"]] 3232 - 3233 - 3234 -When it starts to homing, HW = 0, and it starts to homing at a forward high speed. If the limit switch is not encountered, after encountering the rising edge of HW, it decelerates and reverses the direction, and runs at a reverse low speed. The first Z signal after encountering the falling edge of HW stops. 3235 - 3236 - 3237 -②When homing, the deceleration point signal is invalid and the forward limit switch is encountered 3238 - 3239 -(% style="text-align:center" %) 3240 -[[image:1748222603373-759.jpg||height="482" width="600"]] 3241 - 3242 -When it starts to homing, HW = 0, and it starts to homing at a forward high speed. If it encounters a limit switch, it will automatically reverse and run at a reverse high speed. After encountering the rising edge of HW, it will slow down and continue to run at a reverse low speed. The first Z signal after the falling edge of HW will stop. 3243 - 3244 - 3245 -③ The deceleration point signal is valid when starting homing 3246 - 3247 -(% style="text-align:center" %) 3248 -[[image:1748222658301-527.jpg||height="406" width="600"]] 3249 - 3250 -When starting homing, HW=1, then directly reverse the low speed to start homing, and stop the first Z signal after encountering the falling edge of HW; 3251 - 3252 - 3253 -(8) P01-40=8 3254 - 3255 -Mechanical homing: Motor Z signal 3256 - 3257 -Deceleration point: Home switch (HW) 3258 - 3259 -① The deceleration point signal is invalid when starting homing, the forward limit switch is not encountered 3260 - 3261 -(% style="text-align:center" %) 3262 -[[image:1748222676833-578.jpg||height="425" width="600"]] 3263 - 3264 -When it starts to homing, HM-0 starts to homing at a forward high speed. If it does not encounter the limit switch, after encountering the rising edge of HW, slow down and reverse, and run at a reverse low speed. After encountering the falling edge of HW, reverse, run at a forward low speed, and stop at the first Z signal after encountering the rising edge of HW. 3265 - 3266 - 3267 -② The deceleration point signal is invalid when starting homing, the forward limit switch is encountered 3268 - 3269 -(% style="text-align:center" %) 3270 -[[image:1748222776332-811.jpg||height="460" width="600"]] 3271 - 3272 -When it starts to homing, HW = 0, and it starts to homing at forward high speed. If it encounters a limit switch, it will automatically reverse and run at reverse high speed; After encountering the rising edge of HW, slow down and run at a reverse low speed; After encountering the falling edge of HW, reverse the direction, run at a forward low speed, and stop the first Z signal after encountering the rising edge of HW. 3273 - 3274 - 3275 -③ The deceleration point signal is valid when starting homing 3276 - 3277 -(% style="text-align:center" %) 3278 -[[image:1748222790840-470.jpg||height="403" width="600"]] 3279 - 3280 -When starting to homing, HM-1 will directly reverse and start to return to zero at low speed. After encountering the falling edge of HW, it will reverse and run at forward low speed. The first Z signal after encountering the rising edge of HW will stop. 3281 - 3282 - 3283 - 3284 -(9) P01-40=9 3285 - 3286 -Mechanical homing: Motor Z signal 3287 - 3288 -Deceleration point: Home switch (HW) 3289 - 3290 -① The deceleration point signal is invalid when starting homing, the forward limit switch is not encountered 3291 - 3292 -(% style="text-align:center" %) 3293 -[[image:1748222807478-627.jpg||height="407" width="600"]] 3294 - 3295 -When it starts to homing, HW=0, and it starts to homing at a forward high speed. If the limit switch is not encountered, after encountering the rising edge of HW, it decelerates and runs at a forward low speed; After encountering the falling edge of HW, reverse, run at a low speed in the reverse direction, and stop at the first Z signal after encountering the rising edge of HW. 3296 - 3297 - 3298 -② The deceleration point signal is invalid when starting homing, the forward limit switch is encountered 3299 - 3300 - 3301 -When it starts to homing, HW = 0, and it starts to homing at a forward high speed. If it encounters a limit switch, it will automatically reverse and run at a reverse high speed. After encountering a rising edge of HW, it will slow down and reverse to resume forward operation. Running at a forward low speed, after encountering a falling edge of HW, it will reverse. During reverse low speed operation, the first Z signal after encountering a rising edge of HW will stop. 3302 - 3303 -③ The deceleration point signal is valid when starting homing 3304 - 3305 - 3306 -When starting homing, HW=1 starts homing directly at forward low speed. After encountering the falling edge of HW, the first Z signal after encountering the rising edge of HW stops in reverse and reverse low speed operation; 3307 - 3308 - 3309 -(10) P01-40=10 3310 - 3311 -Mechanical homing: Motor Z signal 3312 - 3313 -Deceleration point: Home switch (HW) 3314 - 3315 -① The deceleration point signal is invalid when starting homing, the forward limit switch is not encountered 3316 - 3317 - 3318 -When it starts to homing, HW = 0, and it starts to homing at a forward high speed. If the limit switch is not encountered, after encountering the rising edge of HW, slow down and run at a forward low speed. After encountering the falling edge of HW, continue to run at a forward low speed, and then the first Z signal encountered stops. 3319 - 3320 -When homing, the deceleration point signal is invalid and the forward limit switch is encountered 3321 - 3322 - 3323 -When it starts to homing, HW = 0, and it starts to homing at a forward high speed. If it encounters a limit switch, it will automatically reverse and run at a reverse high speed. After encountering the rising edge of HW, it will slow down and reverse to resume forward operation. The first Z signal after the low speed encounters the falling edge of HW will stop. 3324 - 3325 - 3326 -③ The deceleration point signal is valid when starting homing 3327 - 3328 - 3329 -When starting homing, HW=1, it will start homing directly at low speed, and the first Z signal after encountering the falling edge of HW will stop; 3330 - 3331 - 3332 -(11) P01-40=11 3333 - 3334 -Mechanical homing: Motor Z signal 3335 - 3336 -Deceleration point: Home switch (HW) 3337 - 3338 -① The deceleration point signal is invalid when starting homing, the reverse limit switch is not encountered 3339 - 3340 - 3341 -When it starts to homing, HW=0, and it starts to homing at a reverse high speed. If the limit switch is not encountered, after encountering the rising edge of HW, it decelerates and reverses the direction, runs at a forward low speed, and stops at the first Z signal after encountering the falling edge of HW. 3342 - 3343 - 3344 -① The deceleration point signal is invalid when starting homing, the reverse limit switch is encountered 3345 - 3346 - 3347 -When it starts to homing, HW=0, and it starts to homing at a reverse high speed. If it encounters a limit switch, it will automatically reverse and run at a forward high speed. After encountering a rising edge of HW, slow down and continue to run at a forward low speed. When encountering a falling edge of HW, the first Z signal after the edge stops. 3348 - 3349 -③ The deceleration point signal is valid when starting homing 3350 - 3351 - 3352 -When starting homing, HW=1, it will start homing directly at low speed, and the first Z signal after encountering the falling edge of HW will stop; 3353 - 3354 - 3355 -(12) P01-40=12 3356 - 3357 -Mechanical homing: Motor Z signal 3358 - 3359 -Deceleration point: Home switch (HW) 3360 - 3361 -① The deceleration point signal is invalid when starting homing, the reverse limit switch is not encountered 3362 - 3363 - 3364 - 3365 -When it starts to homing, HW = 0, it starts to homing at a reverse high speed, and does not encounter a limit switch. After encountering the rising edge of HW, it decelerates and reverses, and runs at a forward low speed. After encountering the falling edge of HW, it reverses and runs at a reverse low speed, and stops at the first Z signal after encountering the rising edge of HW. 3366 - 3367 - 3368 - 3369 -① The deceleration point signal is invalid when starting homing, the reverse limit switch is encountered 3370 - 3371 - 3372 -When it starts to homing, HW=0, it starts to homing at a reverse high speed, encounters a limit switch, automatically reverses, runs at a forward high speed, encounters a rising edge of HW, decelerates, runs at a forward low speed, encounters a falling edge of HW, reverses, runs at a reverse low speed, and stops at the first Z signal after encountering a rising edge of HW. 3373 - 3374 - 3375 - 3376 -③ The deceleration point signal is valid when starting homing 3377 - 3378 - 3379 -When starting to homing, HW = 1, it will directly start to homing at a forward low speed. After encountering the falling edge of HW, it will reverse and run at a reverse low speed. The first Z signal after encountering the rising edge of HW will stop. 3380 - 3381 -(13) P01-40=13 3382 - 3383 -Mechanical homing: Motor Z signal 3384 - 3385 -Deceleration point: Home switch (HW) 3386 - 3387 -① The deceleration point signal is invalid when starting homing, the reverse limit switch is not encountered 3388 - 3389 - 3390 -When it starts to homing, HW=0, and it starts to homing at a reverse high speed. If it does not encounter the limit switch, after encountering the rising edge of HW, slow down and run at a reverse low speed. After encountering the falling edge of HW, reverse and run at a forward low speed, and stop at the first Z signal after encountering the rising edge of HW. 3391 - 3392 - 3393 -① The deceleration point signal is invalid when starting homing, the reverse limit switch is encountered 3394 - 3395 - 3396 -When it starts to homing, HW=0, it starts to homing at reverse high speed, encounters the limit switch, automatically reverses, runs at forward high speed, after encountering the rising edge of HW, decelerates and runs in reverse low speed, and encounters the falling edge of HW when running at reverse low speed, the first Z signal after encountering the rising edge of HW stops. 3397 - 3398 -③ The deceleration point signal is valid when starting homing 3399 - 3400 - 3401 -When starting homing, HW=1 starts homing directly at reverse low speed. After encountering the falling edge of HW, the first Z signal after encountering the rising edge of HW stops in reverse and forward low speed operation; 3402 - 3403 - 3404 -(14) P01-40=14 3405 - 3406 -Mechanical homing: Motor Z signal 3407 - 3408 -Deceleration point: Home switch (HW) 3409 - 3410 -① The deceleration point signal is invalid when starting homing, the reverse limit switch is not encountered 3411 - 3412 - 3413 -When it starts to homing, HW=0, it starts to homing at reverse high speed, and does not encounter the limit switch. After encountering the rising edge of HW, it decelerates and runs at reverse low speed. After encountering the falling edge of HW, it continues to run at reverse low speed, and then the first Z signal encountered stops. 3414 - 3415 - 3416 -① The deceleration point signal is invalid when starting homing, the reverse limit switch is encountered 3417 - 3418 - 3419 -When it starts to homing, HW = 0, it starts to homing at a reverse high speed, encounters a limit switch, automatically reverses, runs at a forward high speed, encounters a rising edge of HW, decelerates and runs in a reverse direction, and stops the first Z signal after encountering a falling edge of HW at a reverse low speed. 3420 - 3421 - 3422 -③ The deceleration point signal is valid when starting homing 3423 - 3424 - 3425 -When starting homing, HW=1, then directly reverse the low speed to start homing, and stop the first Z signal after encountering the falling edge of HW; 3426 - 3427 - 3428 -(15) P01-40=17 3429 - 3430 -Mechanical homing: Negative overrun switch (NOT) 3431 - 3432 -Deceleration point: Negative overrun switch (NOT) 3433 - 3434 -① The deceleration point signal is invalid when starting homing 3435 - 3436 - 3437 -When it starts to homing, NOT = 0, it starts to homing at a high speed in the reverse direction. After encountering the rising edge of NOT, it decelerates and reverses the direction, runs at a low speed in the forward direction, and stops after encountering the falling edge of NOT. 3438 - 3439 - 3440 -② The deceleration point signal is valid when starting homing 3441 - 3442 - 3443 -When starting homing, NOT=1, start homing directly at low speed, and stop after encountering the falling edge of NOT. 3444 - 3445 - 3446 -(16) P01-40=18 3447 - 3448 -Mechanical homing: Positive overrun switch (POT) 3449 - 3450 -Deceleration point: Positive overrun switch (POT) 3451 - 3452 -① The deceleration point signal is invalid when starting homing 3453 - 3454 - 3455 -When it starts to return to zero, POT=0, it starts to homing at a forward high speed, after encountering the rising edge of POT, it decelerates and reverses, runs at a reverse low speed, and stops after encountering the falling edge of POT. 3456 - 3457 - 3458 -② The deceleration point signal is valid when starting homing 3459 - 3460 - 3461 -When starting homing, POT=1, start homing at low speed in reverse directly, and stop when encountering POT falling edge; 3462 - 3463 - 3464 - 3465 -(17) P01-40=19 3466 - 3467 -Mechanical homing: Home switch (HW) 3468 - 3469 -Deceleration point: Home switch (HW) 3470 - 3471 -① The deceleration point signal is invalid when starting homing 3472 - 3473 - 3474 -When it starts to homing, HW=0, and it starts to homing at a forward high speed. After encountering the rising edge of HW, it decelerates and reverses the direction, runs at a reverse low speed, and stops when encountering the falling edge of HW. 3475 - 3476 - 3477 -② The deceleration point signal is valid when starting homing 3478 - 3479 - 3480 -When starting homing, HW=1, start homing at low speed in reverse directly, and stop when encountering HW falling edge; 3481 - 3482 - 3483 -(18) P01-40=20 3484 - 3485 -Mechanical homing: Home switch (HW) 3486 - 3487 -Deceleration point: Home switch (HW) 3488 - 3489 -① The deceleration point signal is invalid when starting homing 3490 - 3491 - 3492 -When starting to homing, HW=0, directly start to homing at low speed, and stop after encountering the rising edge of HW; 3493 - 3494 - 3495 -② The deceleration point signal is valid when starting homing 3496 - 3497 - 3498 -When starting to homing, HW = 1, start to homing at a high speed in the reverse direction. After encountering the falling edge of HW, slow down and reverse the direction, run at a low speed in the forward direction, and stop when encountering the rising edge of HW. 3499 - 3500 - 3501 -(19) P01-40=21 3502 - 3503 -Mechanical homing: Home switch (HW) 3504 - 3505 -Deceleration point: Home switch (HW) 3506 - 3507 -① The deceleration point signal is invalid when starting homing 3508 - 3509 - 3510 -When it starts to homing, HW=0, it starts to homing at a reverse high speed. After encountering the rising edge of HW, it decelerates and reverses the direction, runs at a forward low speed, and stops when encountering the falling edge of HW. 3511 - 3512 - 3513 -② The deceleration point signal is valid when starting homing 3514 - 3515 - 3516 -When starting back to zero, HW=1, it will start homing directly at low speed, and stop after encountering the falling edge of HW; 3517 - 3518 - 3519 -(20) P01-40=22 3520 - 3521 -Mechanical homing: Home switch (HW) 3522 - 3523 -Deceleration point: Home switch (HW) 3524 - 3525 -① The deceleration point signal is invalid when starting homing 3526 - 3527 - 3528 -When starting to homing, HW=0, directly reverse low speed starts to homing, and stops when encountering HW rising edge; 3529 - 3530 - 3531 -Deceleration point signal is valid when homing start 3532 - 3533 - 3534 -When starting to homing, HW=1, start to homing at a forward high speed, after encountering the falling edge of HW, slow down and reverse, run at a reverse low speed, and stop when encountering the rising edge of HW. 3535 - 3536 - 3537 -(21) P01-40=23 3538 - 3539 -Mechanical homing: Home switch (HW) 3540 - 3541 -Deceleration point: Home switch (HW) 3542 - 3543 -① The deceleration point signal is invalid when starting homing, the forward limit switch is not encountered 3544 - 3545 - 3546 -When it starts to homing, HW = 0, it starts to homing at a forward high speed, and does not encounter a limit switch. After encountering the rising edge of HW, it decelerates and reverses, runs at a reverse low speed, and stops when encountering the falling edge of HW. 3547 - 3548 - 3549 -① The deceleration point signal is invalid when starting homing, the forward limit switch is encountered 3550 - 3551 - 3552 -When you start homing, HW = 0, start homing at a forward high speed. When encountering the limit switch, it will automatically reverse and run at a reverse high speed. After encountering the rising edge of HW, slow down, continue to run at reverse low speed, and stop when encountering the HW falling edge. 3553 - 3554 - 3555 - 3556 -③ The deceleration point signal is valid when starting homing 3557 - 3558 - 3559 -When it starts to homing, HW=1, it starts to homing at a reverse low speed, and stops when it encounters the falling edge of HW. 3560 - 3561 - 3562 -(22) P01-40=24 3563 - 3564 -Mechanical homing: Home switch (HW) 3565 - 3566 -Deceleration point: Home switch (HW) 3567 - 3568 -① The deceleration point signal is invalid when starting homing, the forward limit switch is not encountered 3569 - 3570 - 3571 -When it starts to homing, HW = 0, it starts to homing at a forward high speed, and does not encounter a limit switch. After encountering the rising edge of HW, it decelerates and reverses, and runs at a reverse low speed. After encountering the falling edge of HW, it reverses and runs at a forward low speed, and stops when encountering the rising edge of HW. 3572 - 3573 - 3574 -① The deceleration point signal is invalid when starting homing, the forward limit switch is encountered 3575 - 3576 - 3577 -When it starts to homing, HW = 0, it starts to homing at forward high speed, encounters the limit switch, automatically reverses, runs at reverse high speed, encounters the rising edge of HW, decelerates and runs at reverse low speed, encounters the falling edge of HW, reverses, runs at forward low speed, and stops when encountering the rising edge of HW. 3578 - 3579 - 3580 -③ The deceleration point signal is valid when starting homing 3581 - 3582 - 3583 -When starting with homing, HW = 1, it will directly reverse the low speed and start to homing. After encountering the falling edge of HW, it will reverse the direction and run at a forward low speed, and stop when encountering the rising edge of HW. 3584 - 3585 - 3586 -(23) P01-40=25 3587 - 3588 -Mechanical homing: Home switch (HW) 3589 - 3590 -Deceleration point: Home switch (HW) 3591 - 3592 -① The deceleration point signal is invalid when starting homing, the forward limit switch is not encountered 3593 - 3594 - 3595 -When it starts to homing, HW=0, it starts to homing at a forward high speed, and does not encounter a limit switch. After encountering the rising edge of HW, it decelerates and runs at a forward low speed. After encountering the falling edge of HW, it reverses and runs at a reverse low speed, and stops when encountering the rising edge of HW. 3596 - 3597 - 3598 -① The deceleration point signal is invalid when starting homing, the forward limit switch is encountered 3599 - 3600 - 3601 -When it starts to homing, HW=0, it starts to homing at forward high speed, encounters the limit switch, automatically reverses, and runs at reverse high speed. After encountering the rising edge of HW, decelerate and reverse to resume forward operation. After encountering the falling edge of HW at forward low speed, reverse. When running at reverse low speed, stop when encountering the rising edge of HW. 3602 - 3603 - 3604 -③ The deceleration point signal is valid when starting homing 3605 - 3606 - 3607 -When starting homing, when HW=1, it starts to homing directly at low speed in the forward direction. After encountering the falling edge of HW, it stops at the rising edge of HW in the reverse low speed operation 3608 - 3609 - 3610 -(24) P01-40=26 3611 - 3612 -Mechanical homing: Home switch (HW) 3613 - 3614 -Deceleration point: Home switch (HW) 3615 - 3616 -① The deceleration point signal is invalid when starting homing, the forward limit switch is not encountered 3617 - 3618 - 3619 -When it starts to homing, HW=0, it starts to homing at a forward high speed, and does not encounter a limit switch. After encountering the rising edge of HW, it decelerates, runs at a forward low speed, and stops when encountering the falling edge of HW. 3620 - 3621 - 3622 -① The deceleration point signal is invalid when starting homing, the forward limit switch is encountered 3623 - 3624 - 3625 -When it starts to homing, HW=0, it starts to homing at forward high speed, encounters the limit switch, automatically reverses, and runs at reverse high speed. After encountering the rising edge of HW, decelerates and reverses to resume forward operation, and stops when encountering the falling edge of HW at forward low speed. 3626 - 3627 - 3628 -③ The deceleration point signal is valid when starting homing 3629 - 3630 - 3631 -When starting homing, HW=1, it will start homing directly at low speed, and stop when encountering HW falling edge; 3632 - 3633 - 3634 -(25) P01-40=27 3635 - 3636 -Mechanical homing: Home switch (HW) 3637 - 3638 -Deceleration point: Home switch (HW) 3639 - 3640 -① The deceleration point signal is invalid when starting homing, the reverse limit switch is not encountered 3641 - 3642 - 3643 -When it starts to homing, HW=0, it starts to homing at a reverse high speed, and does not encounter a limit switch. After encountering the rising edge of HW, it decelerates and reverses the direction, runs at a forward low speed, and stops when encountering the falling edge of HW. 3644 - 3645 - 3646 -① The deceleration point signal is invalid when starting homing, the reverse limit switch is encountered 3647 - 3648 - 3649 -When it starts to homing, HW=0, it starts to homing at a reverse high speed. When it encounters a limit switch, it automatically reverses and runs at a forward high speed. When it encounters a rising edge of HW, it decelerates and continues to run at a forward low speed. When it encounters a falling edge of HW, it stops. 3650 - 3651 - 3652 -③ The deceleration point signal is valid when starting homing 3653 - 3654 - 3655 -When starting homing, HW=1, it will start homing directly at low speed, and stop when encountering HW falling edge; 3656 - 3657 - 3658 -(26) P01-40=28 3659 - 3660 -Mechanical homing: Home switch (HW) 3661 - 3662 -Deceleration point: Home switch (HW) 3663 - 3664 -① The deceleration point signal is invalid when starting homing, the reverse limit switch is not encountered 3665 - 3666 - 3667 -When it starts to homing, HW=0, it starts to homing at a reverse high speed, and does not encounter a limit switch. After encountering the rising edge of HW, it decelerates and reverses, and runs at a forward low speed. After encountering the falling edge of HW, it reverses and runs at a reverse low speed, and stops when encountering the rising edge of HW. 3668 - 3669 - 3670 -① The deceleration point signal is invalid when starting homing, the reverse limit switch is encountered 3671 - 3672 - 3673 -When it starts to homing, HW=0, it starts to homing at a reverse high speed. When encountering a limit switch, it automatically reverses and runs at a forward high speed. When encountering a rising edge of HW, it decelerates and runs at a forward low speed. When encountering a falling edge of HW, it reverses and runs at a reverse low speed. When encountering a rising edge of HW, it stops. 3674 - 3675 - 3676 -③ The deceleration point signal is valid when starting homing 3677 - 3678 - 3679 -When starting with homing, HW = 1, it will directly start to homing at a forward low speed. After encountering the falling edge of HW, it will reverse and run at a reverse low speed. When encountering the rising edge of HW, it will stop. 3680 - 3681 - 3682 -(27) P01-40=29 3683 - 3684 -Mechanical homing: Home switch (HW) 3685 - 3686 -Deceleration point: Home switch (HW) 3687 - 3688 -① The deceleration point signal is invalid when starting homing, the reverse limit switch is not encountered 3689 - 3690 - 3691 -When it starts to homing, HW = 0, it starts to homing at a reverse high speed, and does not encounter a limit switch. After encountering the rising edge of HW, it decelerates and runs at a reverse low speed. After encountering the falling edge of HW, it reverses and runs at a forward low speed, and stops when encountering the rising edge of HW. 3692 - 3693 - 3694 -① The deceleration point signal is invalid when starting homing, the reverse limit switch is encountered 3695 - 3696 - 3697 -When it starts to homing, HW=0, it starts to homing at a reverse high speed. When it encounters a limit switch, it automatically reverses and runs at a forward high speed. After encountering a rising edge of HW, it decelerates and runs in a reverse low speed. After encountering a falling edge of HW, it reverses. When running at a forward low speed, it stops when it encounters a rising edge of HW. 3698 - 3699 -③ The deceleration point signal is valid when starting homing 3700 - 3701 - 3702 -When starting homing, when HW=1, it starts to homing directly at low speed in reverse direction. After encountering the falling edge of HW, it stops when running at low speed in reverse direction and forward direction and encountering the rising edge of HW 3703 - 3704 - 3705 -(28) P01-40=30 3706 - 3707 -Mechanical homing: Home switch (HW) 3708 - 3709 -Deceleration point: Home switch (HW) 3710 - 3711 -① The deceleration point signal is invalid when starting homing, the reverse limit switch is not encountered 3712 - 3713 - 3714 -When it starts to homing, HW=0, it starts to homing at reverse high speed, and does not encounter the limit switch. After encountering the rising edge of HW, it decelerates, runs at reverse low speed, and stops when encountering the falling edge of HW. 3715 - 3716 - 3717 -① The deceleration point signal is invalid when starting homing, the reverse limit switch is encountered 3718 - 3719 - 3720 -When it starts to homing, HW=0, it starts to homing at a reverse high speed. When it encounters a limit switch, it automatically reverses and runs at a forward high speed. When it encounters a rising edge of HW, it decelerates and runs in a reverse low speed. When it encounters a falling edge of HW, it stops. 3721 - 3722 - 3723 -③ The deceleration point signal is valid when starting homing 3724 - 3725 - 3726 -When starting homing, HW=1, start homing at low speed in reverse directly, and stop when encountering HW falling edge; 3727 - 3728 - 3729 -(29) P01-40=33 and P01-40=34 3730 - 3731 -Mechanical homing: Z signal. 3732 - 3733 -Deceleration point: None 3734 - 3735 -Homing mode 33: Reverse low speed operation, stop the first Z signal encountered 3736 - 3737 -Homing mode 34: running at low speed in forward direction, stopping the first Z signal encountered 3738 - 3739 - 3740 - 3741 -(30) P01-40=35 3742 - 3743 -Homing mode 35, taking the current position as the mechanical homing, after triggering the homing (P01-39: 0x00→0x01/0x00 → 0x02); 3744 - 3745 -After the homing is completed, according to the set value of P10-08 (homing bias compensation), P10-06 (encoder multi-turn reset operation) is executed. 3746 - 3747 - 3748 -
- 1748221916083-747.jpg
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.lxz - Size
-
... ... @@ -1,1 +1,0 @@ 1 -101.4 KB - Content
- 1748221977012-869.jpg
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.lxz - Size
-
... ... @@ -1,1 +1,0 @@ 1 -98.5 KB - Content
- 1748222014107-121.jpg
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.lxz - Size
-
... ... @@ -1,1 +1,0 @@ 1 -102.9 KB - Content
- 1748222027683-713.jpg
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.lxz - Size
-
... ... @@ -1,1 +1,0 @@ 1 -105.8 KB - Content
- 1748222134730-241.jpg
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.lxz - Size
-
... ... @@ -1,1 +1,0 @@ 1 -98.5 KB - Content
- 1748222168627-745.jpg
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.lxz - Size
-
... ... @@ -1,1 +1,0 @@ 1 -102.9 KB - Content
- 1748222190794-857.jpg
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.lxz - Size
-
... ... @@ -1,1 +1,0 @@ 1 -94.7 KB - Content
- 1748222203229-740.jpg
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.lxz - Size
-
... ... @@ -1,1 +1,0 @@ 1 -105.8 KB - Content
- 1748222259038-454.jpg
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.lxz - Size
-
... ... @@ -1,1 +1,0 @@ 1 -104.1 KB - Content
- 1748222356175-586.jpg
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.lxz - Size
-
... ... @@ -1,1 +1,0 @@ 1 -104.0 KB - Content
- 1748222408099-521.jpg
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.lxz - Size
-
... ... @@ -1,1 +1,0 @@ 1 -102.5 KB - Content
- 1748222430449-293.jpg
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.lxz - Size
-
... ... @@ -1,1 +1,0 @@ 1 -102.6 KB - Content
- 1748222448727-825.jpg
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.lxz - Size
-
... ... @@ -1,1 +1,0 @@ 1 -103.0 KB - Content
- 1748222469183-894.jpg
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.lxz - Size
-
... ... @@ -1,1 +1,0 @@ 1 -104.7 KB - Content
- 1748222485622-911.jpg
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.lxz - Size
-
... ... @@ -1,1 +1,0 @@ 1 -104.2 KB - Content
- 1748222509640-301.jpg
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.lxz - Size
-
... ... @@ -1,1 +1,0 @@ 1 -126.7 KB - Content
- 1748222603373-759.jpg
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.lxz - Size
-
... ... @@ -1,1 +1,0 @@ 1 -145.9 KB - Content
- 1748222658301-527.jpg
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.lxz - Size
-
... ... @@ -1,1 +1,0 @@ 1 -126.2 KB - Content
- 1748222676833-578.jpg
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.lxz - Size
-
... ... @@ -1,1 +1,0 @@ 1 -131.1 KB - Content
- 1748222740718-416.jpg
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.lxz - Size
-
... ... @@ -1,1 +1,0 @@ 1 -131.1 KB - Content
- 1748222745765-448.jpg
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.lxz - Size
-
... ... @@ -1,1 +1,0 @@ 1 -131.1 KB - Content
- 1748222754767-406.jpg
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.lxz - Size
-
... ... @@ -1,1 +1,0 @@ 1 -131.1 KB - Content
- 1748222776332-811.jpg
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.lxz - Size
-
... ... @@ -1,1 +1,0 @@ 1 -142.0 KB - Content
- 1748222790840-470.jpg
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.lxz - Size
-
... ... @@ -1,1 +1,0 @@ 1 -127.9 KB - Content
- 1748222807478-627.jpg
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.lxz - Size
-
... ... @@ -1,1 +1,0 @@ 1 -131.2 KB - Content
- 1748222822783-397.jpg
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.lxz - Size
-
... ... @@ -1,1 +1,0 @@ 1 -131.2 KB - Content