Changes for page 06 Operation
Last modified by Iris on 2025/07/23 15:49
From version 106.2
edited by Iris
on 2025/07/21 16:11
on 2025/07/21 16:11
Change comment:
There is no comment for this version
To version 104.1
edited by xingzhi lin
on 2025/05/26 14:10
on 2025/05/26 14:10
Change comment:
There is no comment for this version
Summary
-
Page properties (2 modified, 0 added, 0 removed)
-
Attachments (0 modified, 0 added, 1 removed)
Details
- Page properties
-
- Author
-
... ... @@ -1,1 +1,1 @@ 1 -XWiki. Iris1 +XWiki.lxz - Content
-
... ... @@ -83,14 +83,14 @@ 83 83 0 84 84 )))|((( 85 85 0 to 1 86 -)))|((( 87 -Forward rotation: Face the motor shaft to watch 86 +)))|Forward: facing the motor axis. 87 +0: Standard setting (CW is forward); 88 +1: Reverse mode (CCW is forward); 89 +2: Reverse mode (CCW is forward), set P1-12, 90 +P1-17 to limit the CCW direction speed; set 91 +P1-13, P1-18 to limit the CW direction speed. 92 +**Note:VD2L driver P0-04 setting range: 0~~1, not support P00-4=2!**|- 88 88 89 -0: standard setting (CW is forward rotation) 90 - 91 -1: reverse mode (CCW is forward rotation) 92 -)))|- 93 - 94 94 Table 6-3 Rotation direction parameters** ** 95 95 96 96 == **Braking resistor** == ... ... @@ -120,7 +120,7 @@ 120 120 121 121 3: No braking resistor is used, it is all absorbed by capacitor. 122 122 )))|- 123 -(% class="info" %)|(% colspan="8" scope="row" %)✎**Note: **VD2-010SA1G , VD2F-030SA1P-010SA1Pand VD2L-010SA1P drives have no built-in resistor by default, so the default value of the function code “P00-09” is 3 (No braking resistor is used, it is all absorbed by capacitor).123 +(% class="info" %)|(% colspan="8" scope="row" %)✎**Note: **VD2-010SA1G and VD2F-010SA1P drives have no built-in resistor by default, so the default value of the function code “P00-09” is 3 (No braking resistor is used, it is all absorbed by capacitor). 124 124 |=P00-10|External braking resistor value|(% style="width:118px" %)((( 125 125 Operation setting 126 126 )))|(% style="width:126px" %)((( ... ... @@ -3761,7 +3761,7 @@ 3761 3761 ① The deceleration point signal is invalid when starting homing, the reverse limit switch is encountered 3762 3762 3763 3763 (% style="text-align:center" %) 3764 -[[image:17 51361620036-469.png||height="389" width="600"]]3764 +[[image:1748227761818-990.jpg||height="394" width="600"]] 3765 3765 3766 3766 When it starts to homing, HW=0, it starts to homing at a reverse high speed. When encountering a limit switch, it automatically reverses and runs at a forward high speed. When encountering a rising edge of HW, it decelerates and runs at a forward low speed. When encountering a falling edge of HW, it reverses and runs at a reverse low speed. When encountering a rising edge of HW, it stops. 3767 3767
- 1751361620036-469.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.lxz - Size
-
... ... @@ -1,1 +1,0 @@ 1 -56.0 KB - Content