Changes for page 06 Operation

Last modified by Iris on 2025/08/08 14:40

From version 108.2
edited by Iris
on 2025/07/21 16:52
Change comment: There is no comment for this version
To version 106.6
edited by Iris
on 2025/07/21 16:11
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -220,8 +220,6 @@
220 220  
221 221  4. Trigger DI to turn off servo enable SON.
222 222  
223 -5.Servo enable turns off and stops and decelerates to zero speed.
224 -
225 225  |Function code|Name|(((
226 226  Setting
227 227  
... ... @@ -300,6 +300,13 @@
300 300  23: Internal multi-segment position selection 3
301 301  
302 302  24: Internal multi-segment position selection 4
301 +
302 +25: HOME_START Homing start
303 +26: HOME ORG Homing signal
304 +27: JOGU DI Forward jog
305 +28: JOGD DI Reverse jog
306 +
307 +Others: reserved
303 303  )))|-
304 304  |=(% style="width: 89px;" %)P06-09|(% style="width:135px" %)DI_3 channel logic selection|(% style="width:122px" %)Operation setting|(% style="width:114px" %)(((
305 305  Effective immediately
... ... @@ -369,6 +369,13 @@
369 369  23: Internal multi-segment position selection 3
370 370  
371 371  24: Internal multi-segment position selection 4
377 +
378 +25: HOME_START Homing start
379 +26: HOME ORG Homing signal
380 +27: JOGU DI Forward jog
381 +28: JOGD DI Reverse jog
382 +
383 +Others: reserved
372 372  )))|-
373 373  |=(% style="width: 89px;" %)P06-12|(% style="width:135px" %)DI_4 channel logic selection|(% style="width:122px" %)Operation setting|(% style="width:114px" %)(((
374 374  Effective immediately