Changes for page 06 Operation
Last modified by Iris on 2025/07/23 15:49
Summary
-
Page properties (1 modified, 0 added, 0 removed)
-
Attachments (0 modified, 0 added, 10 removed)
Details
- Page properties
-
- Content
-
... ... @@ -1662,7 +1662,7 @@ 1662 1662 If the absolute value of the actual speed of servo motor is less than a certain threshold P05-19, it is considered that servo motor stops rotating (close to a standstill), and the servo drive outputs a zero speed signal (ZSP) at this time. On the contrary, if the absolute value of the actual speed of the servo motor is not less than this value, it is considered that the motor is not at a standstill and the zero-speed signal is invalid. 1663 1663 1664 1664 (% style="text-align:center" %) 1665 -[[image: image-20220608171904-32.png]]1665 +[[image:http://docs.we-con.com.cn/wiki/servo/download/2.%20User%20Manual/06%20VD2%20SA%20Series%20Servo%20Drives%20Manual%20%28Full%20V1.1%29/WebHome/Wecon%20VD2%20SA%20Series%20Servo%20Drives%20Manual%20%28Full%20V1.1%29_html_5e35c1aad6d8dfbe.gif?rev=1.1||alt="Wecon VD2 SA Series Servo Drives Manual (Full V1.1)_html_5e35c1aad6d8dfbe.gif"]] 1666 1666 1667 1667 Figure 6-36 Zero-speed signal diagram 1668 1668 ... ... @@ -1695,7 +1695,7 @@ 1695 1695 When the absolute value of the deviation between the actual speed of the servo motor after filtering and the speed instruction meets a certain threshold P05-17, it is considered that the actual speed of the motor has reached the set value, and the servo drive outputs a speed coincidence signal (V-COIN) at this time. Conversely, if the absolute value of the deviation between the actual speed of the servo motor and the set speed instruction after filtering exceeds the threshold, the speed consistent signal is invalid. 1696 1696 1697 1697 (% style="text-align:center" %) 1698 -[[image: image-20220608172053-33.png]]1698 +[[image:http://docs.we-con.com.cn/wiki/servo/download/2.%20User%20Manual/06%20VD2%20SA%20Series%20Servo%20Drives%20Manual%20%28Full%20V1.1%29/WebHome/Wecon%20VD2%20SA%20Series%20Servo%20Drives%20Manual%20%28Full%20V1.1%29_html_2b53a916c8f09d5.gif?rev=1.1||alt="Wecon VD2 SA Series Servo Drives Manual (Full V1.1)_html_2b53a916c8f09d5.gif"]] 1699 1699 1700 1700 Figure 6-37 Speed consistent signal diagram 1701 1701 ... ... @@ -1728,7 +1728,7 @@ 1728 1728 After filtering, the absolute value of the actual speed of the servo motor exceeds a certain threshold [P05-17], and it is considered that the actual speed of the servo motor has reached the expected value. At this time, the servo drive can output a speed close signal (V-NEAR) through the DO terminal. Conversely, if the absolute value of the actual speed of the servo motor after filtering is not greater than this value, the speed approach signal is invalid. 1729 1729 1730 1730 (% style="text-align:center" %) 1731 -[[image: image-20220608172207-34.png]]1731 +[[image:http://docs.we-con.com.cn/wiki/servo/download/2.%20User%20Manual/06%20VD2%20SA%20Series%20Servo%20Drives%20Manual%20%28Full%20V1.1%29/WebHome/Wecon%20VD2%20SA%20Series%20Servo%20Drives%20Manual%20%28Full%20V1.1%29_html_46c88547b24e8a4b.gif?rev=1.1||alt="Wecon VD2 SA Series Servo Drives Manual (Full V1.1)_html_46c88547b24e8a4b.gif"]] 1732 1732 1733 1733 Figure 6-38 Speed approaching signal diagram 1734 1734 ... ... @@ -1761,7 +1761,7 @@ 1761 1761 The current of the servo motor has a linear relationship with the torque. Therefore, the control of the current can realize the control of the torque. Torque control refers to controlling the output torque of the motor through torque instructions. Torque instruction could be given by internal instruction and analog voltage. 1762 1762 1763 1763 (% style="text-align:center" %) 1764 -[[image: image-20220608172405-35.png]]1764 +[[image:http://docs.we-con.com.cn/wiki/servo/download/2.%20User%20Manual/06%20VD2%20SA%20Series%20Servo%20Drives%20Manual%20%28Full%20V1.1%29/WebHome/Wecon%20VD2%20SA%20Series%20Servo%20Drives%20Manual%20%28Full%20V1.1%29_html_fa7e410ad05cf1a6.gif?rev=1.1||alt="Wecon VD2 SA Series Servo Drives Manual (Full V1.1)_html_fa7e410ad05cf1a6.gif"]] 1765 1765 1766 1766 Figure 6-39 Torque mode diagram 1767 1767 ... ... @@ -1817,7 +1817,7 @@ 1817 1817 Taking AI_1 as an example, the method of setting torque instruction of analog voltage is as below. 1818 1818 1819 1819 (% style="text-align:center" %) 1820 -[[image: image-20220608172502-36.png]]1820 +[[image:http://docs.we-con.com.cn/wiki/servo/download/2.%20User%20Manual/06%20VD2%20SA%20Series%20Servo%20Drives%20Manual%20%28Full%20V1.1%29/WebHome/Wecon%20VD2%20SA%20Series%20Servo%20Drives%20Manual%20%28Full%20V1.1%29_html_186332b32f148c60.gif?rev=1.1||alt="Wecon VD2 SA Series Servo Drives Manual (Full V1.1)_html_186332b32f148c60.gif"]] 1821 1821 1822 1822 Figure 6-41 Analog voltage torque instruction setting steps 1823 1823 ... ... @@ -1830,7 +1830,7 @@ 1830 1830 Dead zone: It is the corresponding analog input voltage interval when the sample voltage is 0. 1831 1831 1832 1832 (% style="text-align:center" %) 1833 -[[image: image-20220608172611-37.png]]1833 +[[image:http://docs.we-con.com.cn/wiki/servo/download/2.%20User%20Manual/06%20VD2%20SA%20Series%20Servo%20Drives%20Manual%20%28Full%20V1.1%29/WebHome/Wecon%20VD2%20SA%20Series%20Servo%20Drives%20Manual%20%28Full%20V1.1%29_html_9e37dbf27a47694a.gif?rev=1.1||alt="Wecon VD2 SA Series Servo Drives Manual (Full V1.1)_html_9e37dbf27a47694a.gif"]] 1834 1834 1835 1835 Figure 6-42 AI_1 diagram before and after bias 1836 1836 ... ... @@ -1866,7 +1866,7 @@ 1866 1866 ✎**Note: **If the filter time constant is set too large, the responsiveness will be reduced. Please set it while confirming the responsiveness. 1867 1867 1868 1868 (% style="text-align:center" %) 1869 -[[image: image-20220608172646-38.png]]1869 +[[image:http://docs.we-con.com.cn/wiki/servo/download/2.%20User%20Manual/06%20VD2%20SA%20Series%20Servo%20Drives%20Manual%20%28Full%20V1.1%29/WebHome/Wecon%20VD2%20SA%20Series%20Servo%20Drives%20Manual%20%28Full%20V1.1%29_html_205df0eae349c586.gif?rev=1.1||alt="Wecon VD2 SA Series Servo Drives Manual (Full V1.1)_html_205df0eae349c586.gif"]] 1870 1870 1871 1871 Figure 6-43 Torque instruction-first-order filtering diagram 1872 1872 ... ... @@ -1877,7 +1877,7 @@ 1877 1877 At any time, there is only one valid torque limit value. And the positive and negative torque limit values do not exceed the maximum torque of drive and motor and ±300.0% of the rated torque. 1878 1878 1879 1879 (% style="text-align:center" %) 1880 -[[image: image-20220608172806-39.png]]1880 +[[image:http://docs.we-con.com.cn/wiki/servo/download/2.%20User%20Manual/06%20VD2%20SA%20Series%20Servo%20Drives%20Manual%20%28Full%20V1.1%29/WebHome/Wecon%20VD2%20SA%20Series%20Servo%20Drives%20Manual%20%28Full%20V1.1%29_html_5150cab591eac5bc.gif?rev=1.1||alt="Wecon VD2 SA Series Servo Drives Manual (Full V1.1)_html_5150cab591eac5bc.gif"]] 1881 1881 1882 1882 Figure 6-44 Torque instruction limit diagram 1883 1883 ... ... @@ -1956,9 +1956,10 @@ 1956 1956 1957 1957 |((( 1958 1958 (% style="text-align:center" %) 1959 -[[image: image-20220608172910-40.png]]1959 +[[image:http://docs.we-con.com.cn/wiki/servo/download/2.%20User%20Manual/06%20VD2%20SA%20Series%20Servo%20Drives%20Manual%20%28Full%20V1.1%29/WebHome/Wecon%20VD2%20SA%20Series%20Servo%20Drives%20Manual%20%28Full%20V1.1%29_html_e1eced3568bc22d7.gif?rev=1.1||alt="Wecon VD2 SA Series Servo Drives Manual (Full V1.1)_html_e1eced3568bc22d7.gif"]] 1960 1960 )))|((( 1961 -[[image:image-20220608173155-41.png]] 1961 +(% style="text-align:center" %) 1962 +[[image:http://docs.we-con.com.cn/wiki/servo/download/2.%20User%20Manual/06%20VD2%20SA%20Series%20Servo%20Drives%20Manual%20%28Full%20V1.1%29/WebHome/Wecon%20VD2%20SA%20Series%20Servo%20Drives%20Manual%20%28Full%20V1.1%29_html_79d479af8534745f.gif?rev=1.1||alt="Wecon VD2 SA Series Servo Drives Manual (Full V1.1)_html_79d479af8534745f.gif"]] 1962 1962 ))) 1963 1963 |Figure 6-45 Forward running curve|Figure 6-46 Reverse running curve 1964 1964
- image-20220608171904-32.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.Joey - Size
-
... ... @@ -1,1 +1,0 @@ 1 -95.4 KB - Content
- image-20220608172053-33.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.Joey - Size
-
... ... @@ -1,1 +1,0 @@ 1 -84.7 KB - Content
- image-20220608172207-34.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.Joey - Size
-
... ... @@ -1,1 +1,0 @@ 1 -84.5 KB - Content
- image-20220608172405-35.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.Joey - Size
-
... ... @@ -1,1 +1,0 @@ 1 -77.2 KB - Content
- image-20220608172502-36.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.Joey - Size
-
... ... @@ -1,1 +1,0 @@ 1 -132.1 KB - Content
- image-20220608172611-37.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.Joey - Size
-
... ... @@ -1,1 +1,0 @@ 1 -79.0 KB - Content
- image-20220608172646-38.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.Joey - Size
-
... ... @@ -1,1 +1,0 @@ 1 -46.6 KB - Content
- image-20220608172806-39.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.Joey - Size
-
... ... @@ -1,1 +1,0 @@ 1 -97.4 KB - Content
- image-20220608172910-40.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.Joey - Size
-
... ... @@ -1,1 +1,0 @@ 1 -32.4 KB - Content
- image-20220608173155-41.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.Joey - Size
-
... ... @@ -1,1 +1,0 @@ 1 -33.6 KB - Content