Changes for page 06 Operation
Last modified by Iris on 2026/04/17 16:03
Summary
-
Page properties (2 modified, 0 added, 0 removed)
-
Attachments (0 modified, 0 added, 1 removed)
Details
- Page properties
-
- Author
-
... ... @@ -1,1 +1,1 @@ 1 -XWiki. Iris1 +XWiki.Wecon - Content
-
... ... @@ -125,7 +125,7 @@ 125 125 126 126 3: No braking resistor is used, it is all absorbed by capacitor. 127 127 )))|- 128 -(% class="info" %)|(% colspan="8" scope="row" %)✎**Note: **VD2-010SA1G 、VD2F-003SA1P、VD2F-010SA1P、VD2L-003SA1P、VD2L-010SA1P drives have no built-in resistor by default, so the default value of the function code “P00-09” is 3 (No braking resistor is used, it is all absorbed by capacitor).128 +(% class="info" %)|(% colspan="8" scope="row" %)✎**Note: **VD2-010SA1G , VD2F-030SA1P-010SA1P and VD2L-010SA1P drives have no built-in resistor by default, so the default value of the function code “P00-09” is 3 (No braking resistor is used, it is all absorbed by capacitor). 129 129 |=P00-10|External braking resistor value|(% style="width:118px" %)((( 130 130 Operation setting 131 131 )))|(% style="width:126px" %)((( ... ... @@ -909,8 +909,6 @@ 909 909 1: Cycle running 910 910 911 911 2: DI switching running 912 - 913 -3: Run continuously 914 914 )))|- 915 915 |=P07-02|Start segment number|((( 916 916 Shutdown setting ... ... @@ -922,7 +922,7 @@ 922 922 )))|((( 923 923 Effective immediately 924 924 )))|1|1 to 16|last segment NO. in non-DI switching mode|- 925 -|=P07-04| Remaining segmenthandlingmethod|(((923 +|=P07-04|Margin processing method|((( 926 926 Shutdown setting 927 927 )))|((( 928 928 Effective immediately ... ... @@ -1008,17 +1008,13 @@ 1008 1008 1009 1009 The operating curve in this running mode is shown in __Figure 6-14__. 1010 1010 1011 -4. Continuous operation 1012 - 1013 -In this mode, the segment number switches automatically in ascending order. The servo driver runs repeatedly according to the total number of multi-segment position commands set by P07-02 and P07-03. All segments operate continuously without any waiting time in between. The cyclic operation curve is shown in Figure 6-15, where S1, S2, S3, and S4 indicate the displacements of Segment 1, Segment 2, Segment 3, and Segment 4 respectively. 1014 - 1015 1015 (% style="text-align:center" %) 1016 1016 ((( 1017 -(% style="display:inline-block" %) 1018 -[[Figure 6-1 5 Singlerunning-runtheremainingsegments (P07-02=1, P07-03=4)>>image:1776396988490-710.png]]1011 +(% class="wikigeneratedid img-thumbnail" style="display:inline-block" %) 1012 +[[**Figure 6-14 DI switching running curve**>>image:image-20220608164545-12.png||id="Iimage-20220608164545-12.png"]] 1019 1019 ))) 1020 1020 1021 -VD2 series servo drives have two remaining segmenthandlingmethods runningthe remaining segments and run from the start segment again. The related function code is P07-04.1015 +VD2 series servo drives have two margin processing methods: run the remaining segments and run from the start segment again. The related function code is P07-04. 1022 1022 1023 1023 **Run the remaining segments** 1024 1024
- 1776396988490-710.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.Iris - Size
-
... ... @@ -1,1 +1,0 @@ 1 -20.6 KB - Content