... ... @@ -91,12 +91,12 @@
91 91  1. the maximum brake energy calculated value > the maximum brake energy absorbed by capacitor, and the brake power calculated value ≤ the built-in braking resistor power, use the built-in braking resistor.
92 92  1. the maximum brake energy calculated value > the maximum brake energy absorbed by capacitor, and the brake power calculated value > the built-in braking resistor power, use external braking resistor.
93 93  
94 -|=(% scope="row" %)**Function code**|=**Name**|=(((
94 +|**Function code**|**Name**|(((
95 95  **Setting method**
96 -)))|=(((
96 +)))|(((
97 97  **Effective time**
98 -)))|=**Default**|=**Range**|=**Definition**|=**Unit**
99 -|=P00-09|Braking resistor setting|(((
98 +)))|**Default**|**Range**|**Definition**|**Unit**
99 +|P00-09|Braking resistor setting|(((
100 100  Operation setting
101 101  )))|(((
102 102  Effective immediately
... ... @@ -109,13 +109,13 @@
109 109  
110 110  3: No braking resistor is used, it is all absorbed by capacitor.
111 111  )))|-
112 -|=(% colspan="8" %)✎**Note: **VD2-010SA1G and VD2F-010SA1P drives have no built-in resistor by default, so the default value of the function code “P00-09” is 3 (No braking resistor is used, it is all absorbed by capacitor).
113 -|=P00-10|External braking resistor value|(((
112 +|(% colspan="8" %)✎**Note: **VD2-010SA1G and VD2F-010SA1P drives have no built-in resistor by default, so the default value of the function code “P00-09” is 3 (No braking resistor is used, it is all absorbed by capacitor).
113 +|P00-10|External braking resistor value|(((
114 114  Operation setting
115 115  )))|(((
116 116  Effective immediately
117 117  )))|50|0 to 65535|It is used to set the external braking resistor value of a certain type of drive.|Ω
118 -|=P00-11|External braking resistor power|(((
118 +|P00-11|External braking resistor power|(((
119 119  Operation setting
120 120  )))|(((
121 121  Effective immediately