Changes for page 06 Operation
Last modified by Iris on 2025/07/23 15:49
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -838,11 +838,11 @@ 838 838 In this running mode, the next running segment number could be set when operating the current segment number. The interval time is determined by the instruction delay of the host computer. The running segment number is determined by DI terminal logic, and the related function codes are shown in the table below. 839 839 840 840 841 -|**DI function code**|**Function name**|**Function** 842 -|21|INPOS1: Internal multi-segment position segment selection 1|Form internal multi-segment position running segment number 843 -|22|INPOS2: Internal multi-segment position segment selection 2|Form internal multi-segment position running segment number 844 -|23|INPOS3: Internal multi-segment position segment selection 3|Form internal multi-segment position running segment number 845 -|24|INPOS4: Internal multi-segment position segment selection 4|Form internal multi-segment position running segment number 841 +|=(% scope="row" %)**DI function code**|=**Function name**|=**Function** 842 +|=21|INPOS1: Internal multi-segment position segment selection 1|Form internal multi-segment position running segment number 843 +|=22|INPOS2: Internal multi-segment position segment selection 2|Form internal multi-segment position running segment number 844 +|=23|INPOS3: Internal multi-segment position segment selection 3|Form internal multi-segment position running segment number 845 +|=24|INPOS4: Internal multi-segment position segment selection 4|Form internal multi-segment position running segment number 846 846 847 847 Table 6-17 DI function code 848 848 ... ... @@ -849,12 +849,12 @@ 849 849 The multi-segment segment number is a 4-bit binary number, and the DI terminal logic is level valid. When the input level is valid, the segment selection bit value is 1, otherwise it is 0. Table 6-17 shows the correspondence between the position bits 1 to 4 of the internal multi-segment position and the position number. 850 850 851 851 852 -|**INPOS4**|**INPOS3**|**INPOS2**|**INPOS1**|**Running position number** 853 -|0|0|0|0|1 854 -|0|0|0|1|2 855 -|0|0|1|0|3 856 -|(% colspan="5" %)………… 857 -|1|1|1|1|16 852 +|=(% scope="row" %)**INPOS4**|=**INPOS3**|=**INPOS2**|=**INPOS1**|=**Running position number** 853 +|=0|0|0|0|1 854 +|=0|0|0|1|2 855 +|=0|0|1|0|3 856 +|=(% colspan="5" %)………… 857 +|=1|1|1|1|16 858 858 859 859 Table 6-18 INPOS corresponds to running segment number 860 860 ... ... @@ -924,12 +924,8 @@ 924 924 The multi-segment position running supports maximum 16 segments different position instructions. The displacement, maximum running speed (steady-state running speed), acceleration and deceleration time of each position and the waiting time between segment could all be set. __[[Table 6-19>>http://13.229.109.52:8080/wiki/servo/view/2.%20User%20Manual/06%20VD2%20SA%20Series%20Servo%20Drives%20Manual%20(Full%20V1.1)/06%20Operation/#HPositioninstructioninputsetting]]__ are the related function codes of the 1st segment running curve. 925 925 926 926 927 -|**Function code**|**Name**|((( 928 -**Setting method** 929 -)))|((( 930 -**Effective time** 931 -)))|**Default value**|**Range**|**Definition**|**Unit** 932 -|P07-09|((( 927 +|=(% scope="row" %)**Function code**|=**Name**|=**Setting method**|=**Effective time**|=**Default value**|=**Range**|=**Definition**|=**Unit** 928 +|=P07-09|((( 933 933 1st segment 934 934 935 935 displacement ... ... @@ -942,17 +942,17 @@ 942 942 943 943 2147483646 944 944 )))|Position instruction, positive and negative values could be set|- 945 -|P07-10|Maximum speed of the 1st displacement|((( 941 +|=P07-10|Maximum speed of the 1st displacement|((( 946 946 Operation setting 947 947 )))|((( 948 948 Effective immediately 949 949 )))|100|1 to 5000|Steady-state running speed of the 1st segment|rpm 950 -|P07-11|Acceleration and deceleration of 1st segment displacement|((( 946 +|=P07-11|Acceleration and deceleration of 1st segment displacement|((( 951 951 Operation setting 952 952 )))|((( 953 953 Effective immediately 954 954 )))|100|1 to 65535|The time required for the acceleration and deceleration of the 1st segment|ms 955 -|P07-12|Waiting time after completion of the 1st segment displacement|((( 951 +|=P07-12|Waiting time after completion of the 1st segment displacement|((( 956 956 Operation setting 957 957 )))|((( 958 958 Effective immediately