Changes for page 06 Operation

Last modified by Iris on 2025/07/23 15:49

From version 48.9
edited by Joey
on 2022/06/15 14:46
Change comment: (Autosaved)
To version 51.3
edited by Stone Wu
on 2022/07/07 09:23
Change comment: (Autosaved)

Summary

Details

Page properties
Parent
... ... @@ -1,1 +1,1 @@
1 -Servo.2\. User Manual.06 VD2 SA Series Servo Drives Manual (Full V1\.1).WebHome
1 +Servo.1 User Manual.02 VD2 SA Series.WebHome
Author
... ... @@ -1,1 +1,1 @@
1 -XWiki.Joey
1 +XWiki.Stone
Content
... ... @@ -61,13 +61,7 @@
61 61  By setting the “P00-04” rotation direction, you could change the rotation direction of the motor without changing the polarity of the input instruction. The function code is shown in below.
62 62  
63 63  
64 -|=(% scope="row" %)**Function code**|=**Name**|=(((
65 -**Setting method**
66 -)))|=(((
67 -**Effective time**
68 -)))|=(((
69 -**Default value**
70 -)))|=**Range**|=**Definition**|=**Unit**
64 +|=(% scope="row" %)**Function code**|=**Name**|=**Setting method**|=Effective time|=**Default value**|=**Range**|=**Definition**|=**Unit**
71 71  |=P00-04|Rotation direction|(((
72 72  Shutdown setting
73 73  )))|(((
... ... @@ -516,7 +516,7 @@
516 516  Operation setting
517 517  )))|(((
518 518  immediately Effective
519 -)))|0|0 to 1|(((
513 +)))|0|0 to 6|(((
520 520  0: position control
521 521  
522 522  2: speed control
... ... @@ -558,8 +558,7 @@
558 558  
559 559  1) Low-speed pulse instruction input
560 560  
561 -
562 -|[[image:https://docs.we-con.com.cn/bin/download/Servo/2.%20User%20Manual/06%20VD2%20SA%20Series%20Servo%20Drives%20Manual%20%28Full%20V1.1%29/06%20Operation/WebHome/22.jpg?rev=1.1]]|[[image:https://docs.we-con.com.cn/bin/download/Servo/2.%20User%20Manual/06%20VD2%20SA%20Series%20Servo%20Drives%20Manual%20%28Full%20V1.1%29/06%20Operation/WebHome/23.jpg?rev=1.1]]
555 +|[[image:image-20220707092316-1.png]]|[[image:image-20220707092322-2.png]]
563 563  |VD2A and VD2B servo drives|VD2F servo drive
564 564  |(% colspan="2" %)Figure 6-7 Position instruction input setting
565 565  
... ... @@ -578,9 +578,8 @@
578 578  
579 579  Take VD2A and VD2B drive as examples, the connection of differential input is shown as below.
580 580  
574 +[[image:image-20220707092440-4.jpeg]]
581 581  
582 -[[image:https://docs.we-con.com.cn/bin/download/Servo/2.%20User%20Manual/06%20VD2%20SA%20Series%20Servo%20Drives%20Manual%20%28Full%20V1.1%29/06%20Operation/WebHome/24.jpg?rev=1.1]]
583 -
584 584  Figure 6-8 Differential input connection
585 585  
586 586  ✎**Note: **The differential input connection of the VD2F drive differs only from the signal pin number. Please refer to “__[[4.4.3 position instruction input signal>>https://docs.we-con.com.cn/bin/view/Servo/2.%20User%20Manual/06%20VD2%20SA%20Series%20Servo%20Drives%20Manual%20%28Full%20V1.1%29/04%20Wiring/#HPositioninstructioninputsignal]]__”
... ... @@ -589,9 +589,8 @@
589 589  
590 590  Take VD2A and VD2B drive as examples, the connection of differential input is shown as below.
591 591  
584 +[[image:image-20220707092401-3.jpeg]]
592 592  
593 -[[image:https://docs.we-con.com.cn/bin/download/Servo/2.%20User%20Manual/06%20VD2%20SA%20Series%20Servo%20Drives%20Manual%20%28Full%20V1.1%29/06%20Operation/WebHome/25.jpg?rev=1.1]]
594 -
595 595  Figure 6-9 Open collector input connection
596 596  
597 597  ✎**Note:** The differential input connection of the VD2F drive differs only from the signal pin number. Please refer to “__[[4.4.3 position instruction input signal>>https://docs.we-con.com.cn/bin/view/Servo/2.%20User%20Manual/06%20VD2%20SA%20Series%20Servo%20Drives%20Manual%20%28Full%20V1.1%29/04%20Wiring/#HPositioninstructioninputsignal]]__”
... ... @@ -1976,7 +1976,7 @@
1976 1976  
1977 1977  Table 6-48 Speed limit parameters in torque mode
1978 1978  
1979 -✎**Note:** Function codes P01-17 and P01-18 are only effective in limiting motor speed under the torque mode. The speed limit value is set according to load requirements. To set speed limit in speed mode or position mode, please refer to __[[6.3.3 Speed instruction limit>>http://13.229.109.52:8080/wiki/servo/view/2.%20User%20Manual/06%20VD2%20SA%20Series%20Servo%20Drives%20Manual%20(Full%20V1.1)/06%20Operation/#HSpeedinstructionlimit]]__.
1970 +✎**Note:** Function codes P01-17 and P01-18 are only effective in limiting motor speed under the torque mode. The speed limit value is set according to load requirements. To set speed limit in speed mode or position mode, please refer to __[[6.3.3 Speed instruction limit>>https://docs.we-con.com.cn/bin/view/Servo/2.%20User%20Manual/06%20VD2%20SA%20Series%20Servo%20Drives%20Manual%20%28Full%20V1.1%29/06%20Operation/#HSpeedinstructionlimit]]__.
1980 1980  
1981 1981  == **Torque-related DO output functions** ==
1982 1982  
... ... @@ -1991,7 +1991,7 @@
1991 1991  
1992 1992  Figure 6-47 Torque arrival output diagram
1993 1993  
1994 -To use the torque arrival function, a DO terminal of the servo drive should be assigned to function 138 (T-COIN, torque arrival). The function code parameters and related DO function codes are shown in __[[Table 6-49>>http://13.229.109.52:8080/wiki/servo/view/2.%20User%20Manual/06%20VD2%20SA%20Series%20Servo%20Drives%20Manual%20(Full%20V1.1)/06%20Operation/#HTorque-relatedDOoutputfunctions]]__ and __[[Table 6-50>>http://13.229.109.52:8080/wiki/servo/view/2.%20User%20Manual/06%20VD2%20SA%20Series%20Servo%20Drives%20Manual%20(Full%20V1.1)/06%20Operation/#HTorque-relatedDOoutputfunctions]]__.
1985 +To use the torque arrival function, a DO terminal of the servo drive should be assigned to function 138 (T-COIN, torque arrival). The function code parameters and related DO function codes are shown in __[[Table 6-49>>https://docs.we-con.com.cn/bin/view/Servo/2.%20User%20Manual/06%20VD2%20SA%20Series%20Servo%20Drives%20Manual%20%28Full%20V1.1%29/06%20Operation/#HTorque-relatedDOoutputfunctions]]__ and __[[Table 6-50>>https://docs.we-con.com.cn/bin/view/Servo/2.%20User%20Manual/06%20VD2%20SA%20Series%20Servo%20Drives%20Manual%20%28Full%20V1.1%29/06%20Operation/#HTorque-relatedDOoutputfunctions]]__.
1995 1995  
1996 1996  
1997 1997  |**Function code**|**Name**|(((
... ... @@ -2072,7 +2072,7 @@
2072 2072  
2073 2073  Table 6-51 Mixed control mode parameters
2074 2074  
2075 -Please set the servo drive parameters in different control modes according to the mechanical structure and indicators. The setting method refer to [[__“Parameters”__>>url:http://docs.we-con.com.cn/wiki/servo/view/2.%20User%20Manual/06%20VD2%20SA%20Series%20Servo%20Drives%20Manual%20%28Full%20V1.1%29/#_Chapter%209%20Parameters]]. When function code P00-01=4/5/6 (that is, in mixed mode), a DI terminal of the servo drive needs to be assigned to function 17 (MixModeSel, mixed mode selection), and the DI terminal logic is determined to be valid.
2066 +Please set the servo drive parameters in different control modes according to the mechanical structure and indicators. The setting method refer to [[__“Parameters”__>>https://docs.we-con.com.cn/bin/view/Servo/2.%20User%20Manual/06%20VD2%20SA%20Series%20Servo%20Drives%20Manual%20%28Full%20V1.1%29/09%20Parameters/]]. When function code P00-01=4/5/6 (that is, in mixed mode), a DI terminal of the servo drive needs to be assigned to function 17 (MixModeSel, mixed mode selection), and the DI terminal logic is determined to be valid.
2076 2076  
2077 2077  
2078 2078  |**DI function code**|**Name**|**Function name**|**Function**
image-20220707092316-1.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Stone
Size
... ... @@ -1,0 +1,1 @@
1 +277.2 KB
Content
image-20220707092322-2.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Stone
Size
... ... @@ -1,0 +1,1 @@
1 +277.2 KB
Content
image-20220707092401-3.jpeg
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Stone
Size
... ... @@ -1,0 +1,1 @@
1 +73.4 KB
Content
image-20220707092440-4.jpeg
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Stone
Size
... ... @@ -1,0 +1,1 @@
1 +33.1 KB
Content