... ... @@ -125,7 +125,7 @@
125 125  
126 126  3: No braking resistor is used, it is all absorbed by capacitor.
127 127  )))|-
128 -(% class="info" %)|(% colspan="8" scope="row" %)✎**Note: **VD2-010SA1GVD2F-003SA1P、VD2F-010SA1PVD2L-003SA1P、VD2L-010SA1P drives have no built-in resistor by default, so the default value of the function code “P00-09” is 3 (No braking resistor is used, it is all absorbed by capacitor).
128 +(% class="info" %)|(% colspan="8" scope="row" %)✎**Note: **VD2-010SA1G , VD2F-030SA1P-010SA1P and VD2L-010SA1P drives have no built-in resistor by default, so the default value of the function code “P00-09” is 3 (No braking resistor is used, it is all absorbed by capacitor).
129 129  |=P00-10|External braking resistor value|(% style="width:118px" %)(((
130 130  Operation setting
131 131  )))|(% style="width:126px" %)(((
... ... @@ -909,8 +909,6 @@
909 909  1: Cycle running
910 910  
911 911  2: DI switching running
912 -
913 -3: Run continuously
914 914  )))|-
915 915  |=P07-02|Start segment number|(((
916 916  Shutdown setting
... ... @@ -922,7 +922,7 @@
922 922  )))|(((
923 923  Effective immediately
924 924  )))|1|1 to 16|last segment NO. in non-DI switching mode|-
925 -|=P07-04|Remaining segment handling method|(((
923 +|=P07-04|Margin processing method|(((
926 926  Shutdown setting
927 927  )))|(((
928 928  Effective immediately
... ... @@ -1008,17 +1008,13 @@
1008 1008  
1009 1009  The operating curve in this running mode is shown in __Figure 6-14__.
1010 1010  
1011 -4. Continuous operation
1012 -
1013 -In this mode, the segment number switches automatically in ascending order. The servo driver runs repeatedly according to the total number of multi-segment position commands set by P07-02 and P07-03. All segments operate continuously without any waiting time in between. The cyclic operation curve is shown in Figure 6-15, where S1, S2, S3, and S4 indicate the displacements of Segment 1, Segment 2, Segment 3, and Segment 4 respectively.
1014 -
1015 1015  (% style="text-align:center" %)
1016 1016  (((
1017 -(% style="display:inline-block" %)
1018 -[[Figure 6-15 Single running-run the remaining segments (P07-02=1, P07-03=4)>>image:1776396988490-710.png]]
1011 +(% class="wikigeneratedid img-thumbnail" style="display:inline-block" %)
1012 +[[**Figure 6-14 DI switching running curve**>>image:image-20220608164545-12.png||id="Iimage-20220608164545-12.png"]]
1019 1019  )))
1020 1020  
1021 -VD2 series servo drives have two remaining segment handling methods running the remaining segments and run from the start segment again. The related function code is P07-04.
1015 +VD2 series servo drives have two margin processing methods: run the remaining segments and run from the start segment again. The related function code is P07-04.
1022 1022  
1023 1023  **Run the remaining segments**
1024 1024  
... ... @@ -2651,7 +2651,7 @@
2651 2651  
2652 2652  **Cautions**
2653 2653  
2654 -When the battery is connected for the first time, Er.40 (Encoder battery failure) will occur. First, set function code P10-06 = 1 to reset the multi-turn encoder. After the reset, set function code P10-03 = 1 to clear the encoder fault, then perform the absolute value system operation again.
2648 +Er.40 (Encoder battery failure) will occur when the battery is turned on for the first time, and the function code P10-03 must be set to 1 to clear the encoder fault to operate the absolute value system again.
2655 2655  
2656 2656  (% style="text-align:center" %)
2657 2657  (((
... ... @@ -2837,7 +2837,7 @@
2837 2837  
2838 2838  == Port filtering time ==
2839 2839  
2840 -VD2A, VD2B and VD2C servo drives have 8 hardware DI terminals (DI_1 to DI_8) , VD2F and VD2L servo drivehave 4 hardware DI terminals (DI_1 to DI_4) . All the DI terminals are normal terminals.
2834 +VD2A and VD2B servo drives have 8 hardware DI terminals (DI_1 to DI_8) , and VD2F servo drive has 4 hardware DI terminals (DI_1 to DI_4) . All the DI terminals are normal terminals.
2841 2841  
2842 2842  |=(% scope="row" style="width: 204px;" %)**Setting value**|=(% style="width: 235px;" %)**DI channel logic selection**|=(% style="width: 637px;" %)**Illustration**
2843 2843  |=(% style="width: 204px;" %)0|(% style="width:235px" %)Active high level|(% style="width:637px" %)[[image:image-20220707113050-31.jpeg]]