Changes for page 06 Operation
Last modified by Iris on 2026/04/17 16:03
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -2651,7 +2651,7 @@ 2651 2651 2652 2652 **Cautions** 2653 2653 2654 - When the battery is connected for the first time,Er.40 (Encoder battery failure) will occur. First,set functioncode P10-06 = 1to resetthemulti-turnencoder. Afterthe reset,set function code P10-03=1 to clear the encoder fault,thenperformthe absolute value systemoperation again.2654 +Er.40 (Encoder battery failure) will occur when the battery is turned on for the first time, and the function code P10-03 must be set to 1 to clear the encoder fault to operate the absolute value system again. 2655 2655 2656 2656 (% style="text-align:center" %) 2657 2657 ((( ... ... @@ -2837,7 +2837,7 @@ 2837 2837 2838 2838 == Port filtering time == 2839 2839 2840 -VD2A , VD2Band VD2Cservo drives have 8 hardware DI terminals (DI_1 toDI_8) ,VD2Fand VD2Lservo driveshave4 hardware DI terminals (DI_1 toDI_4). All the DI terminals are normal terminals.2840 +VD2A and VD2B servo drives have 8 hardware DI terminals (DI_1 to DI_8) , and VD2F servo drive has 4 hardware DI terminals (DI_1 to DI_4) . All the DI terminals are normal terminals. 2841 2841 2842 2842 |=(% scope="row" style="width: 204px;" %)**Setting value**|=(% style="width: 235px;" %)**DI channel logic selection**|=(% style="width: 637px;" %)**Illustration** 2843 2843 |=(% style="width: 204px;" %)0|(% style="width:235px" %)Active high level|(% style="width:637px" %)[[image:image-20220707113050-31.jpeg]]