Changes for page 06 Operation
Last modified by Iris on 2026/04/17 16:03
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -796,7 +796,7 @@ 796 796 797 797 5: A, B phase quadrature pulse (4 times frequency negative logic) 798 798 799 -**✎Note: VD2 F and VD2Lseries driversdo not support the pulse form of CW/CCW! P0-12 parameter setting range of VD2L: 0, 2, 3, 5**799 +**✎Note: **VD2L series drivers do not support the pulse form of CW/CCW! P0-12 parameter setting range of VD2L: 0, 2, 3, 5 800 800 )))|- 801 801 802 802 Table 6-16 Position pulse type selection parameter ... ... @@ -894,16 +894,24 @@ 894 894 895 895 * Set multi-segment position running mode 896 896 897 -|=(% scope="row" %)**Function code**|=**Name**|=((( 898 -**Setting method** 899 -)))|=((( 900 -**Effective time** 901 -)))|=**Default value**|=**Range**|=**Definition**|=**Unit** 902 -|=P07-01|Multi-segment position running mode|((( 903 -Shutdown setting 897 +|**Function code**|**Name**|((( 898 +**Setting** 899 + 900 +**method** 904 904 )))|((( 905 -Effective immediately 906 -)))|0|0 to 2|((( 902 +**Effective** 903 + 904 +**time** 905 +)))|**Default value**|**Range**|**Definition** 906 +|P07-01|Multi-segment position running mode|((( 907 +Shutdown 908 + 909 +setting 910 +)))|((( 911 +Effective 912 + 913 +immediately 914 +)))|0|0 to 3|((( 907 907 0: Single running 908 908 909 909 1: Cycle running ... ... @@ -910,37 +910,66 @@ 910 910 911 911 2: DI switching running 912 912 913 -3: Run continuously 914 -)))|- 915 -|=P07-02|Start segment number|((( 916 -Shutdown setting 921 +3: Run continuously 922 +))) 923 +|P07-02|Start segment number|((( 924 +Shutdown 925 + 926 +setting 917 917 )))|((( 918 -Effective immediately 919 -)))|1|1 to 16|1st segment NO. in non-DI switching mode|- 920 -|=P07-03|End segment number|((( 921 -Shutdown setting 928 +Effective 929 + 930 +immediately 931 +)))|1|1 to 16|1st segment NO. in non-DI switching mode 932 +|P07-03|End segment number|((( 933 +Shutdown 934 + 935 +setting 922 922 )))|((( 923 -Effective immediately 924 -)))|1|1 to 16|last segment NO. in non-DI switching mode|- 925 -|=P07-04|Remaining segment handling method|((( 926 -Shutdown setting 937 +Effective 938 + 939 +immediately 940 +)))|1|1 to 16|last segment NO. in non-DI switching mode 941 +|P07-04|Remaining segment handling method|((( 942 +Shutdown 943 + 944 +setting 927 927 )))|((( 928 -Effective immediately 929 -)))|0|0 to 1|((( 946 +Effective 947 + 948 +immediately 949 +)))|0|0 to 1|((( 930 930 0: Run the remaining segments 931 931 932 -1: Run again from the start segment 933 -)))|- 934 -|=P07-05|Displacement instruction type|((( 935 -Shutdown setting 952 +1: Run again from the start segment 953 +))) 954 +|P07-05|Displacement instruction type|((( 955 +Shutdown 956 + 957 +setting 936 936 )))|((( 937 -Effective immediately 938 -)))|0|0 to 1|((( 939 -(% id="cke_bm_79356S" style="display:none" %) (%%)0: Relative position instruction 959 +Effective 940 940 941 -1: Absolute position instruction(% id="cke_bm_79356E" style="display:none" %) 942 -)))|- 961 +immediately 962 +)))|0|0 to 1|((( 963 +0: Relative position instruction 943 943 965 +1: Absolute position instruction 966 +))) 967 +|P07-07|Pulse remainder processing method|((( 968 +Shutdown 969 + 970 +setting 971 +)))|((( 972 +Effective 973 + 974 +immediately 975 +)))|0|0 to 1|((( 976 +0: Discard remaining pulses 977 + 978 +1: Execute remaining pulses 979 +))) 980 + 944 944 Table 6-18 multi-segment position running mode parameters 945 945 946 946 VD2 series servo drive has three multi-segment position running modes, and you could select the best running mode according to the site requirements.