Changes for page 06 Operation
Last modified by Iris on 2025/08/06 18:24
Summary
-
Page properties (2 modified, 0 added, 0 removed)
Details
- Page properties
-
- Parent
-
... ... @@ -1,1 +1,1 @@ 1 -Servo. 1User Manual.02VD2 SA Series.WebHome1 +Servo.2\. User Manual.06 VD2 SA Series Servo Drives Manual (Full V1\.1).WebHome - Content
-
... ... @@ -25,7 +25,7 @@ 25 25 26 26 After power on the main circuit, the bus voltage indicator shows no abnormality, and the panel display "rdy", indicating that the servo drive is in an operational state, waiting for the host computer to give the servo enable signal. 27 27 28 -If the drive panel displays other fault codes, please refer to __[[“10 Faults>>http s://docs.we-con.com.cn/bin/view/Servo/2.%20User%20Manual/06%20VD2%20SA%20Series%20Servo%20Drives%20Manual%20%28Full%20V1.1%29/10%20Malfunctions/]]__” to analyze and eliminate the cause of the fault.28 +If the drive panel displays other fault codes, please refer to __[[“10 Faults>>http://13.229.109.52:8080/wiki/servo/view/2.%20User%20Manual/06%20VD2%20SA%20Series%20Servo%20Drives%20Manual%20%28Full%20V1.1%29/10%20Malfunctions/#HFaultandwarningcodetable]]__” to analyze and eliminate the cause of the fault. 29 29 30 30 **(2) Set the servo drive enable (S-ON) to invalid (OFF)** 31 31 ... ... @@ -35,7 +35,7 @@ 35 35 36 36 **(1) Panel jog operation** 37 37 38 -Enter “P10-01” by pressing the key on the panel. After pressing “OK”, the panel will display the current jog speed. At this time, you can adjust the jog speed by pressing the "up" or "down" keys; After adjusting the moving speed, press "OK", and the panel displays "JOG" and is in a flashing state. Press "OK" again to enter the jog operation mode (the motor is now powered on!). Long press the "up" and "down" keys to achieve the forward and reverse rotation of the motor. Press "Mode" key to exit the jog operation mode. For operation and display, please refer to __[["5.3.2. Jog operation">>http s://docs.we-con.com.cn/bin/view/Servo/2.%20User%20Manual/06%20VD2%20SA%20Series%20Servo%20Drives%20Manual%20%28Full%20V1.1%29/05%20Panel/#HJogoperation]]__.38 +Enter “P10-01” by pressing the key on the panel. After pressing “OK”, the panel will display the current jog speed. At this time, you can adjust the jog speed by pressing the "up" or "down" keys; After adjusting the moving speed, press "OK", and the panel displays "JOG" and is in a flashing state. Press "OK" again to enter the jog operation mode (the motor is now powered on!). Long press the "up" and "down" keys to achieve the forward and reverse rotation of the motor. Press "Mode" key to exit the jog operation mode. For operation and display, please refer to __[["5.3.2. Jog operation">>http://13.229.109.52:8080/wiki/servo/view/2.%20User%20Manual/06%20VD2%20SA%20Series%20Servo%20Drives%20Manual%20%28Full%20V1.1%29/05%20Panel/#HJogoperation]]__. 39 39 40 40 **(2) Jog operation of servo debugging platform** 41 41 ... ... @@ -61,7 +61,13 @@ 61 61 By setting the “P00-04” rotation direction, you could change the rotation direction of the motor without changing the polarity of the input instruction. The function code is shown in below. 62 62 63 63 64 -|=(% scope="row" %)**Function code**|=**Name**|=**Setting method**|=Effective time|=**Default value**|=**Range**|=**Definition**|=**Unit** 64 +|=(% scope="row" %)**Function code**|=**Name**|=((( 65 +**Setting method** 66 +)))|=((( 67 +**Effective time** 68 +)))|=((( 69 +**Default value** 70 +)))|=**Range**|=**Definition**|=**Unit** 65 65 |=P00-04|Rotation direction|((( 66 66 Shutdown setting 67 67 )))|((( ... ... @@ -127,7 +127,7 @@ 127 127 128 128 **(2) Input the instruction and the motor rotates** 129 129 130 -Input appropriate instructions during operation, first run the motor at a low speed, and observe the rotation to see if it conforms to the set rotation direction. Observe the actual running speed, bus voltage and other parameters of the motor through the host computer debugging platform. According to [[__"7 Adjustment"__>>http s://docs.we-con.com.cn/bin/view/Servo/2.%20User%20Manual/06%20VD2%20SA%20Series%20Servo%20Drives%20Manual%20%28Full%20V1.1%29/07%20Adjustments/]], the motor could work as expected.136 +Input appropriate instructions during operation, first run the motor at a low speed, and observe the rotation to see if it conforms to the set rotation direction. Observe the actual running speed, bus voltage and other parameters of the motor through the host computer debugging platform. According to [[__"7 Adjustment"__>>http://13.229.109.52:8080/wiki/servo/view/2.%20User%20Manual/06%20VD2%20SA%20Series%20Servo%20Drives%20Manual%20%28Full%20V1.1%29/07%20Adjustments/]], the motor could work as expected. 131 131 132 132 **(3) Timing diagram of power on** 133 133 ... ... @@ -138,7 +138,7 @@ 138 138 139 139 == **Servo shutdown** == 140 140 141 -According to the different shutdown modes, it could be divided into free shutdown and zero speed shutdown. The respective characteristics are shown in __[[Table 6-5>>http s://docs.we-con.com.cn/bin/view/Servo/2.%20User%20Manual/06%20VD2%20SA%20Series%20Servo%20Drives%20Manual%20%28Full%20V1.1%29/06%20Operation/#HServoshutdown]]__. According to the shutdown status, it could be divided into free running state and position locked, as shown in __[[Table 6-6>>https://docs.we-con.com.cn/bin/view/Servo/2.%20User%20Manual/06%20VD2%20SA%20Series%20Servo%20Drives%20Manual%20%28Full%20V1.1%29/06%20Operation/#HServoshutdown]]__.147 +According to the different shutdown modes, it could be divided into free shutdown and zero speed shutdown. The respective characteristics are shown in __[[Table 6-5>>http://13.229.109.52:8080/wiki/servo/view/2.%20User%20Manual/06%20VD2%20SA%20Series%20Servo%20Drives%20Manual%20(Full%20V1.1)/06%20Operation/#HServoshutdown]]__. According to the shutdown status, it could be divided into free running state and position locked, as shown in __[[Table 6-6>>http://13.229.109.52:8080/wiki/servo/view/2.%20User%20Manual/06%20VD2%20SA%20Series%20Servo%20Drives%20Manual%20(Full%20V1.1)/06%20Operation/#HServoshutdown]]__. 142 142 143 143 144 144 |=(% scope="row" %)Shutdown mode|=Shutdown description|=Shutdown characteristics ... ... @@ -438,7 +438,7 @@ 438 438 439 439 1) Brake timing when servo motor is stationary 440 440 441 -When the servo enable changes from ON to OFF, if the actual motor speed is lower than20 rpm, the servo drive will act according to the static brake sequence. The specific sequence action is shown in __[[Figure 6-3>>http s://docs.we-con.com.cn/bin/download/Servo/2.%20User%20Manual/06%20VD2%20SA%20Series%20Servo%20Drives%20Manual%20%28Full%20V1.1%29/06%20Operation/WebHome/image-20220608163304-3.png?rev=1.1]]__447 +When the servo enable changes from ON to OFF, if the actual motor speed is lower than20 rpm, the servo drive will act according to the static brake sequence. The specific sequence action is shown in __[[Figure 6-3>>http://docs.we-con.com.cn/wiki/servo/download/2.%20User%20Manual/06%20VD2%20SA%20Series%20Servo%20Drives%20Manual%20%28Full%20V1.1%29/WebHome/Wecon%20VD2%20SA%20Series%20Servo%20Drives%20Manual%20%28Full%20V1.1%29_html_2da3eb860da7ba31.gif?rev=1.1]]__ 442 442 443 443 444 444 |((( ... ... @@ -458,7 +458,7 @@ 458 458 459 459 2) The brake timing when servo motor rotates 460 460 461 -When the servo enable is from ON to OFF, if the actual motor speed is greater than or equal to 20 rpm, the drive will act in accordance with the rotation brake sequence. The specific sequence action is shown in __[[Figure 6-4>>http s://docs.we-con.com.cn/bin/download/Servo/2.%20User%20Manual/06%20VD2%20SA%20Series%20Servo%20Drives%20Manual%20%28Full%20V1.1%29/06%20Operation/WebHome/image-20220608163425-4.png?rev=1.1]]__.467 +When the servo enable is from ON to OFF, if the actual motor speed is greater than or equal to 20 rpm, the drive will act in accordance with the rotation brake sequence. The specific sequence action is shown in __[[Figure 6-4>>http://docs.we-con.com.cn/wiki/servo/download/2.%20User%20Manual/06%20VD2%20SA%20Series%20Servo%20Drives%20Manual%20%28Full%20V1.1%29/WebHome/Wecon%20VD2%20SA%20Series%20Servo%20Drives%20Manual%20%28Full%20V1.1%29_html_4408711d09c83291.gif?rev=1.1]]__. 462 462 463 463 464 464 |((( ... ... @@ -501,12 +501,12 @@ 501 501 Set “P00-01” to 1 by the software “Wecon SCTool”, and the servo drive is in position control mode. 502 502 503 503 504 -| =(% scope="row" %)**Function code**|=**Name**|=(((510 +|**Function code**|**Name**|((( 505 505 **Setting method** 506 -)))| =(((512 +)))|((( 507 507 **Effective time** 508 -)))| =**Default value**|=**Range**|=**Definition**|=**Unit**509 -| =P01-01|Control mode|(((514 +)))|**Default value**|**Range**|**Definition**|**Unit** 515 +|P01-01|Control mode|((( 510 510 Operation setting 511 511 )))|((( 512 512 immediately Effective ... ... @@ -531,12 +531,12 @@ 531 531 When the VD2 series servo drive is in position control mode, firstly set the position instruction source through the function code “P01-06”. 532 532 533 533 534 -| =(% scope="row" %)**Function code**|=**Name**|=(((540 +|**Function code**|**Name**|((( 535 535 **Setting method** 536 -)))| =(((542 +)))|((( 537 537 **Effective time** 538 -)))| =**Default value**|=**Range**|=**Definition**|=**Unit**539 -| =P01-06|Position instruction source|(((544 +)))|**Default value**|**Range**|**Definition**|**Unit** 545 +|P01-06|Position instruction source|((( 540 540 Operation setting 541 541 )))|((( 542 542 immediately Effective ... ... @@ -557,7 +557,7 @@ 557 557 |VD2A and VD2B servo drives|VD2F servo drive 558 558 |(% colspan="2" %)Figure 6-7 Position instruction input setting 559 559 560 -VD2 series servo drive has a set of pulse input terminals to receive the input of position pulse (via the CN2 terminal). The position pulse mode connection is shown in __[[Figure 6-7>>http s://docs.we-con.com.cn/bin/view/Servo/2.%20User%20Manual/06%20VD2%20SA%20Series%20Servo%20Drives%20Manual%20%28Full%20V1.1%29/06%20Operation/#HPositioninstructioninputsetting]]__.566 +VD2 series servo drive has a set of pulse input terminals to receive the input of position pulse (via the CN2 terminal). The position pulse mode connection is shown in __[[Figure 6-7>>http://13.229.109.52:8080/wiki/servo/view/2.%20User%20Manual/06%20VD2%20SA%20Series%20Servo%20Drives%20Manual%20(Full%20V1.1)/06%20Operation/#HPositioninstructioninputsetting]]__. 561 561 562 562 The instruction pulse and symbol output circuit on the control device(HMI/PLC) side could select differential input or open collector input. The maximum input frequency is shown as below. 563 563 ... ... @@ -577,7 +577,7 @@ 577 577 578 578 Figure 6-8 Differential input connection 579 579 580 -✎**Note: **The differential input connection of the VD2F drive differs only from the signal pin number. Please refer to “__[[4.4.3 position instruction input signal>>http s://docs.we-con.com.cn/bin/view/Servo/2.%20User%20Manual/06%20VD2%20SA%20Series%20Servo%20Drives%20Manual%20%28Full%20V1.1%29/04%20Wiring/#HPositioninstructioninputsignal]]__”586 +✎**Note: **The differential input connection of the VD2F drive differs only from the signal pin number. Please refer to “__[[4.4.3 position instruction input signal>>http://13.229.109.52:8080/wiki/servo/view/2.%20User%20Manual/06%20VD2%20SA%20Series%20Servo%20Drives%20Manual%20%28Full%20V1.1%29/04%20Wiring/#HPositioninstructioninputsignal]]__” 581 581 582 582 2.Open collector input 583 583 ... ... @@ -588,7 +588,7 @@ 588 588 589 589 Figure 6-9 Open collector input connection 590 590 591 -✎**Note:** The differential input connection of the VD2F drive differs only from the signal pin number. Please refer to “__[[4.4.3 position instruction input signal>>http s://docs.we-con.com.cn/bin/view/Servo/2.%20User%20Manual/06%20VD2%20SA%20Series%20Servo%20Drives%20Manual%20%28Full%20V1.1%29/04%20Wiring/#HPositioninstructioninputsignal]]__”597 +✎**Note:** The differential input connection of the VD2F drive differs only from the signal pin number. Please refer to “__[[4.4.3 position instruction input signal>>http://13.229.109.52:8080/wiki/servo/view/2.%20User%20Manual/06%20VD2%20SA%20Series%20Servo%20Drives%20Manual%20%28Full%20V1.1%29/04%20Wiring/#HPositioninstructioninputsignal]]__” 592 592 593 593 2) Position pulse frequency and anti-interference level 594 594 ... ... @@ -602,17 +602,17 @@ 602 602 The input pulse frequency refers to the frequency of the input signal, which can be modified through the function code “P00-13”. If the actual input frequency is greater than the set value of “P00-13”, it may cause pulse loss or alarm. The position pulse anti-interference level can be adjusted through the function code “P00-14”, the larger the set value, the greater the filtering depth. The details of related function code parameters are as shown below. 603 603 604 604 605 -| =(% scope="row" %)**Function code**|=**Name**|=(((611 +|**Function code**|**Name**|((( 606 606 **Setting method** 607 -)))| =(((613 +)))|((( 608 608 **Effective time** 609 -)))| =**Default value**|=**Range**|=(% colspan="2" %)**Definition**|=**Unit**610 -| =P00-13|Maximum position pulse frequency|(((615 +)))|**Default value**|**Range**|(% colspan="2" %)**Definition**|**Unit** 616 +|P00-13|Maximum position pulse frequency|((( 611 611 Shutdown setting 612 612 )))|((( 613 613 Effective immediately 614 614 )))|300|1 to 500|(% colspan="2" %)Set the maximum frequency of external pulse instruction|KHz 615 -| =(% rowspan="3" %)P00-14|(% rowspan="3" %)Position pulse anti-interference level|(% rowspan="3" %)(((621 +|(% rowspan="3" %)P00-14|(% rowspan="3" %)Position pulse anti-interference level|(% rowspan="3" %)((( 616 616 Operation setting 617 617 )))|(% rowspan="3" %)((( 618 618 Power-on again ... ... @@ -637,8 +637,8 @@ 637 637 638 638 8: Filtering time 16.384us 639 639 )))|(% rowspan="3" %)- 640 -| =(% rowspan="2" %)9|VD2: Filtering time 25.5us641 -| =VD2F: Filtering time 25.5us646 +|(% rowspan="2" %)9|VD2: Filtering time 25.5us 647 +|VD2F: Filtering time 25.5us 642 642 643 643 Table 6-13 Position pulse frequency and anti-interference level parameters 644 644 ... ... @@ -647,12 +647,12 @@ 647 647 In VD2 series servo drives, there are three types of input pulse instructions, and the related function codes are shown in the table below. 648 648 649 649 650 -| =(% scope="row" %)**Function code**|=**Name**|=(((656 +|**Function code**|**Name**|((( 651 651 **Setting method** 652 -)))| =(((658 +)))|((( 653 653 **Effective time** 654 -)))| =**Default value**|=**Range**|=**Definition**|=**Unit**655 -| =P00-12|Position pulse type selection|(((660 +)))|**Default value**|**Range**|**Definition**|**Unit** 661 +|P00-12|Position pulse type selection|((( 656 656 Operation setting 657 657 )))|((( 658 658 Power-on again ... ... @@ -673,8 +673,8 @@ 673 673 Table 6-14 Position pulse type selection parameter 674 674 675 675 676 -| =(% scope="row" %)**Pulse type selection**|=**Pulse type**|=**Signal**|=**Schematic diagram of forward pulse**|=**Schematic diagram of negative pulse**677 -| =0|(((682 +|**Pulse type selection**|**Pulse type**|**Signal**|**Schematic diagram of forward pulse**|**Schematic diagram of negative pulse** 683 +|0|((( 678 678 Direction + pulse 679 679 680 680 (Positive logic) ... ... @@ -683,12 +683,12 @@ 683 683 684 684 SIGN 685 685 )))|[[image:https://docs.we-con.com.cn/bin/download/Servo/2.%20User%20Manual/06%20VD2%20SA%20Series%20Servo%20Drives%20Manual%20%28Full%20V1.1%29/06%20Operation/WebHome/21.jpg?rev=1.1]]|[[image:https://docs.we-con.com.cn/bin/download/Servo/2.%20User%20Manual/06%20VD2%20SA%20Series%20Servo%20Drives%20Manual%20%28Full%20V1.1%29/06%20Operation/WebHome/26.jpg?rev=1.1]] 686 -| =1|CW/CCW|(((692 +|1|CW/CCW|((( 687 687 PULSE (CW) 688 688 689 689 SIGN (CCW) 690 690 )))|(% colspan="2" %)[[image:https://docs.we-con.com.cn/bin/download/Servo/2.%20User%20Manual/06%20VD2%20SA%20Series%20Servo%20Drives%20Manual%20%28Full%20V1.1%29/06%20Operation/WebHome/27.jpg?rev=1.1]] 691 -| =2|(((697 +|2|((( 692 692 AB phase orthogonal 693 693 694 694 pulse (4 times frequency) ... ... @@ -705,7 +705,7 @@ 705 705 706 706 Phase B is 90° ahead of Phase A 707 707 ))) 708 -| =3|(((714 +|3|((( 709 709 Direction + pulse 710 710 711 711 (Negative logic) ... ... @@ -714,7 +714,7 @@ 714 714 715 715 SIGN 716 716 )))|[[image:https://docs.we-con.com.cn/bin/download/Servo/2.%20User%20Manual/06%20VD2%20SA%20Series%20Servo%20Drives%20Manual%20%28Full%20V1.1%29/06%20Operation/WebHome/30.jpg?rev=1.1]]|[[image:https://docs.we-con.com.cn/bin/download/Servo/2.%20User%20Manual/06%20VD2%20SA%20Series%20Servo%20Drives%20Manual%20%28Full%20V1.1%29/06%20Operation/WebHome/31.jpg?rev=1.1]] 717 -| =4|(((723 +|4|((( 718 718 CW/CCW 719 719 720 720 (Negative logic) ... ... @@ -723,7 +723,7 @@ 723 723 724 724 SIGN (CCW) 725 725 )))|(% colspan="2" %)[[image:https://docs.we-con.com.cn/bin/download/Servo/2.%20User%20Manual/06%20VD2%20SA%20Series%20Servo%20Drives%20Manual%20%28Full%20V1.1%29/06%20Operation/WebHome/32.jpg?rev=1.1]] 726 -| =5|(((732 +|5|((( 727 727 AB phase orthogonal 728 728 729 729 pulse (4 times frequency negative logic) ... ... @@ -745,7 +745,7 @@ 745 745 746 746 **(2) The source of position instruction is internal position instruction (P01-06=1)** 747 747 748 -The VD2 series servo drive has a multi-segment position operation function, which supports maximum 16-segment instructions. The displacement, maximum operating speed (steady-state operating speed) and acceleration/deceleration time of each segment could be set separately. The waiting time between positions could also be set according to actual needs. The setting process of multi-segment position is shown in __[[Figure 6-11>>http s://docs.we-con.com.cn/bin/download/Servo/2.%20User%20Manual/06%20VD2%20SA%20Series%20Servo%20Drives%20Manual%20%28Full%20V1.1%29/06%20Operation/WebHome/image-20220608164116-9.png?rev=1.1]]__.754 +The VD2 series servo drive has a multi-segment position operation function, which supports maximum 16-segment instructions. The displacement, maximum operating speed (steady-state operating speed) and acceleration/deceleration time of each segment could be set separately. The waiting time between positions could also be set according to actual needs. The setting process of multi-segment position is shown in __[[Figure 6-11>>http://docs.we-con.com.cn/wiki/servo/download/2.%20User%20Manual/06%20VD2%20SA%20Series%20Servo%20Drives%20Manual%20%28Full%20V1.1%29/WebHome/Wecon%20VD2%20SA%20Series%20Servo%20Drives%20Manual%20%28Full%20V1.1%29_html_6173c39e1ccf532e.gif?rev=1.1]]__. 749 749 750 750 The servo drive completely runs the multi-segment position instruction set by P07-01 once, and the total number of positions is called completing one round of operation. 751 751 ... ... @@ -757,12 +757,12 @@ 757 757 1) Set multi-segment position running mode 758 758 759 759 760 -| =(% scope="row" %)**Function code**|=**Name**|=(((766 +|**Function code**|**Name**|((( 761 761 **Setting method** 762 -)))| =(((768 +)))|((( 763 763 **Effective time** 764 -)))| =**Default value**|=**Range**|=**Definition**|=**Unit**765 -| =P07-01|Multi-segment position running mode|(((770 +)))|**Default value**|**Range**|**Definition**|**Unit** 771 +|P07-01|Multi-segment position running mode|((( 766 766 Shutdown setting 767 767 )))|((( 768 768 Effective immediately ... ... @@ -773,17 +773,17 @@ 773 773 774 774 2: DI switching running 775 775 )))|- 776 -| =P07-02|Start segment number|(((782 +|P07-02|Start segment number|((( 777 777 Shutdown setting 778 778 )))|((( 779 779 Effective immediately 780 780 )))|1|1 to 16|1st segment NO. in non-DI switching mode|- 781 -| =P07-03|End segment number|(((787 +|P07-03|End segment number|((( 782 782 Shutdown setting 783 783 )))|((( 784 784 Effective immediately 785 785 )))|1|1 to 16|last segment NO. in non-DI switching mode|- 786 -| =P07-04|Margin processing method|(((792 +|P07-04|Margin processing method|((( 787 787 Shutdown setting 788 788 )))|((( 789 789 Effective immediately ... ... @@ -792,7 +792,7 @@ 792 792 793 793 1: Run again from the start segment 794 794 )))|- 795 -| =P07-05|Displacement instruction type|(((801 +|P07-05|Displacement instruction type|((( 796 796 Shutdown setting 797 797 )))|((( 798 798 Effective immediately ... ... @@ -808,7 +808,7 @@ 808 808 809 809 ~1. Single running 810 810 811 -In this running mode, the segment number is automatically incremented and switched, and the servo drive only operates for one round (the servo drive runs completely once for the total number of multi-segment position instructions set by P07-02 and P07-03). The single running curve is shown in __[[Figure 6-12>>http s://docs.we-con.com.cn/bin/download/Servo/2.%20User%20Manual/06%20VD2%20SA%20Series%20Servo%20Drives%20Manual%20%28Full%20V1.1%29/06%20Operation/WebHome/image-20220608164226-10.png?rev=1.1]]__, and S1 and S2 are the displacements of the 1st segment and the 2nd segment respectively817 +In this running mode, the segment number is automatically incremented and switched, and the servo drive only operates for one round (the servo drive runs completely once for the total number of multi-segment position instructions set by P07-02 and P07-03). The single running curve is shown in __[[Figure 6-12>>http://docs.we-con.com.cn/wiki/servo/download/2.%20User%20Manual/06%20VD2%20SA%20Series%20Servo%20Drives%20Manual%20%28Full%20V1.1%29/WebHome/Wecon%20VD2%20SA%20Series%20Servo%20Drives%20Manual%20%28Full%20V1.1%29_html_669701d67ab2f246.gif?rev=1.1]]__, and S1 and S2 are the displacements of the 1st segment and the 2nd segment respectively 812 812 813 813 814 814 [[image:image-20220608164226-10.png]] ... ... @@ -817,7 +817,7 @@ 817 817 818 818 2. Cycle running 819 819 820 -In this running mode, the position number is automatically incremented and switched, and the servo drive repeatedly runs the total number of multi-segment position instructions set by P07-02 and P07-03. The waiting time could be set between each segment. The cycle running curve is shown in __[[Figure 6-13>>http s://docs.we-con.com.cn/bin/download/Servo/2.%20User%20Manual/06%20VD2%20SA%20Series%20Servo%20Drives%20Manual%20%28Full%20V1.1%29/06%20Operation/WebHome/image-20220608164327-11.png?rev=1.1]]__, and S1,S2,S3 and S4 are the displacements of the 1st, 2nd, 3rd and 4th segment respectively.826 +In this running mode, the position number is automatically incremented and switched, and the servo drive repeatedly runs the total number of multi-segment position instructions set by P07-02 and P07-03. The waiting time could be set between each segment. The cycle running curve is shown in __[[Figure 6-13>>http://docs.we-con.com.cn/wiki/servo/download/2.%20User%20Manual/06%20VD2%20SA%20Series%20Servo%20Drives%20Manual%20%28Full%20V1.1%29/WebHome/Wecon%20VD2%20SA%20Series%20Servo%20Drives%20Manual%20%28Full%20V1.1%29_html_80b358d07288f7b4.gif?rev=1.1]]__, and S1,S2,S3 and S4 are the displacements of the 1st, 2nd, 3rd and 4th segment respectively. 821 821 822 822 823 823 [[image:image-20220608164327-11.png]] ... ... @@ -832,11 +832,11 @@ 832 832 In this running mode, the next running segment number could be set when operating the current segment number. The interval time is determined by the instruction delay of the host computer. The running segment number is determined by DI terminal logic, and the related function codes are shown in the table below. 833 833 834 834 835 -| =(% scope="row" %)**DI function code**|=**Function name**|=**Function**836 -| =21|INPOS1: Internal multi-segment position segment selection 1|Form internal multi-segment position running segment number837 -| =22|INPOS2: Internal multi-segment position segment selection 2|Form internal multi-segment position running segment number838 -| =23|INPOS3: Internal multi-segment position segment selection 3|Form internal multi-segment position running segment number839 -| =24|INPOS4: Internal multi-segment position segment selection 4|Form internal multi-segment position running segment number841 +|**DI function code**|**Function name**|**Function** 842 +|21|INPOS1: Internal multi-segment position segment selection 1|Form internal multi-segment position running segment number 843 +|22|INPOS2: Internal multi-segment position segment selection 2|Form internal multi-segment position running segment number 844 +|23|INPOS3: Internal multi-segment position segment selection 3|Form internal multi-segment position running segment number 845 +|24|INPOS4: Internal multi-segment position segment selection 4|Form internal multi-segment position running segment number 840 840 841 841 Table 6-17 DI function code 842 842 ... ... @@ -843,16 +843,16 @@ 843 843 The multi-segment segment number is a 4-bit binary number, and the DI terminal logic is level valid. When the input level is valid, the segment selection bit value is 1, otherwise it is 0. Table 6-17 shows the correspondence between the position bits 1 to 4 of the internal multi-segment position and the position number. 844 844 845 845 846 -| =(% scope="row" %)**INPOS4**|=**INPOS3**|=**INPOS2**|=**INPOS1**|=**Running position number**847 -| =0|0|0|0|1848 -| =0|0|0|1|2849 -| =0|0|1|0|3850 -| =(% colspan="5" %)…………851 -| =1|1|1|1|16852 +|**INPOS4**|**INPOS3**|**INPOS2**|**INPOS1**|**Running position number** 853 +|0|0|0|0|1 854 +|0|0|0|1|2 855 +|0|0|1|0|3 856 +|(% colspan="5" %)………… 857 +|1|1|1|1|16 852 852 853 853 Table 6-18 INPOS corresponds to running segment number 854 854 855 -The operating curve in this running mode is shown in __[[Figure 6-14>>http s://docs.we-con.com.cn/bin/download/Servo/2.%20User%20Manual/06%20VD2%20SA%20Series%20Servo%20Drives%20Manual%20%28Full%20V1.1%29/06%20Operation/WebHome/image-20220608164545-12.png?rev=1.1]]__.861 +The operating curve in this running mode is shown in __[[Figure 6-14>>http://docs.we-con.com.cn/wiki/servo/download/2.%20User%20Manual/06%20VD2%20SA%20Series%20Servo%20Drives%20Manual%20%28Full%20V1.1%29/WebHome/Wecon%20VD2%20SA%20Series%20Servo%20Drives%20Manual%20%28Full%20V1.1%29_html_91c44ab732c79e26.gif?rev=1.1]]__. 856 856 857 857 858 858 [[image:image-20220608164545-12.png]] ... ... @@ -863,7 +863,7 @@ 863 863 864 864 **A. Run the remaining segments** 865 865 866 -In this processing way, the multi-segment position instruction enable is OFF during running, the servo drive will abandon the unfinished displacement part and shutdown, and the positioning completion signal will be valid after the shutdown is complete. When the multi-segment position enable is ON, and the servo drive will start to run from the next segment where the OFF occurs. The curves of single running and cycle running are shown in __[[Figure 6-15>>http s://docs.we-con.com.cn/bin/download/Servo/2.%20User%20Manual/06%20VD2%20SA%20Series%20Servo%20Drives%20Manual%20%28Full%20V1.1%29/06%20Operation/WebHome/image-20220608164847-13.png?rev=1.1]]__ and __[[Figure 6-16>>https://docs.we-con.com.cn/bin/download/Servo/2.%20User%20Manual/06%20VD2%20SA%20Series%20Servo%20Drives%20Manual%20%28Full%20V1.1%29/06%20Operation/WebHome/image-20220608165032-14.png?rev=1.1]]__ respectively.872 +In this processing way, the multi-segment position instruction enable is OFF during running, the servo drive will abandon the unfinished displacement part and shutdown, and the positioning completion signal will be valid after the shutdown is complete. When the multi-segment position enable is ON, and the servo drive will start to run from the next segment where the OFF occurs. The curves of single running and cycle running are shown in __[[Figure 6-15>>http://docs.we-con.com.cn/wiki/servo/download/2.%20User%20Manual/06%20VD2%20SA%20Series%20Servo%20Drives%20Manual%20%28Full%20V1.1%29/WebHome/Wecon%20VD2%20SA%20Series%20Servo%20Drives%20Manual%20%28Full%20V1.1%29_html_29777829e6742c0d.gif?rev=1.1]]__ and __[[Figure 6-16>>http://docs.we-con.com.cn/wiki/servo/download/2.%20User%20Manual/06%20VD2%20SA%20Series%20Servo%20Drives%20Manual%20%28Full%20V1.1%29/WebHome/Wecon%20VD2%20SA%20Series%20Servo%20Drives%20Manual%20%28Full%20V1.1%29_html_d264849e0940e3e4.gif?rev=1.1]]__ respectively. 867 867 868 868 869 869 [[image:image-20220608164847-13.png]] ... ... @@ -877,7 +877,7 @@ 877 877 878 878 **B. Run again from the start segment** 879 879 880 -In this processing mode, when the multi-segment position instruction enable is OFF during running, the servo drive will abandon the uncompleted displacement part and shutdown. After the shutdown is completed, the positioning completion signal is valid. When the multi-segment position enable is ON, and the servo drive will start to operate from the next position set by P07-02. The curves of single running and cycle running are shown in __[[Figure 6-17>>http s://docs.we-con.com.cn/bin/download/Servo/2.%20User%20Manual/06%20VD2%20SA%20Series%20Servo%20Drives%20Manual%20%28Full%20V1.1%29/06%20Operation/WebHome/image-20220608165343-15.png?rev=1.1]]__ and __[[Figure 6-18>>https://docs.we-con.com.cn/bin/download/Servo/2.%20User%20Manual/06%20VD2%20SA%20Series%20Servo%20Drives%20Manual%20%28Full%20V1.1%29/06%20Operation/WebHome/image-20220608165558-16.png?rev=1.1]]__ respectively.886 +In this processing mode, when the multi-segment position instruction enable is OFF during running, the servo drive will abandon the uncompleted displacement part and shutdown. After the shutdown is completed, the positioning completion signal is valid. When the multi-segment position enable is ON, and the servo drive will start to operate from the next position set by P07-02. The curves of single running and cycle running are shown in __[[Figure 6-17>>http://docs.we-con.com.cn/wiki/servo/download/2.%20User%20Manual/06%20VD2%20SA%20Series%20Servo%20Drives%20Manual%20%28Full%20V1.1%29/WebHome/Wecon%20VD2%20SA%20Series%20Servo%20Drives%20Manual%20%28Full%20V1.1%29_html_2328499c9613af49.gif?rev=1.1]]__ and __[[Figure 6-18>>http://docs.we-con.com.cn/wiki/servo/download/2.%20User%20Manual/06%20VD2%20SA%20Series%20Servo%20Drives%20Manual%20%28Full%20V1.1%29/WebHome/Wecon%20VD2%20SA%20Series%20Servo%20Drives%20Manual%20%28Full%20V1.1%29_html_1f2e35174b1afd3c.gif?rev=1.1]]__ respectively. 881 881 882 882 883 883 [[image:image-20220608165343-15.png]] ... ... @@ -915,11 +915,15 @@ 915 915 916 916 2) Multi-segment position running curve setting 917 917 918 -The multi-segment position running supports maximum 16 segments different position instructions. The displacement, maximum running speed (steady-state running speed), acceleration and deceleration time of each position and the waiting time between segment could all be set. __[[Table 6-19>>http s://docs.we-con.com.cn/bin/view/Servo/2.%20User%20Manual/06%20VD2%20SA%20Series%20Servo%20Drives%20Manual%20%28Full%20V1.1%29/06%20Operation/#HPositioninstructioninputsetting]]__ are the related function codes of the 1st segment running curve.924 +The multi-segment position running supports maximum 16 segments different position instructions. The displacement, maximum running speed (steady-state running speed), acceleration and deceleration time of each position and the waiting time between segment could all be set. __[[Table 6-19>>http://13.229.109.52:8080/wiki/servo/view/2.%20User%20Manual/06%20VD2%20SA%20Series%20Servo%20Drives%20Manual%20(Full%20V1.1)/06%20Operation/#HPositioninstructioninputsetting]]__ are the related function codes of the 1st segment running curve. 919 919 920 920 921 -|=(% scope="row" %)**Function code**|=**Name**|=**Setting method**|=**Effective time**|=**Default value**|=**Range**|=**Definition**|=**Unit** 922 -|=P07-09|((( 927 +|**Function code**|**Name**|((( 928 +**Setting method** 929 +)))|((( 930 +**Effective time** 931 +)))|**Default value**|**Range**|**Definition**|**Unit** 932 +|P07-09|((( 923 923 1st segment 924 924 925 925 displacement ... ... @@ -932,17 +932,17 @@ 932 932 933 933 2147483646 934 934 )))|Position instruction, positive and negative values could be set|- 935 -| =P07-10|Maximum speed of the 1st displacement|(((945 +|P07-10|Maximum speed of the 1st displacement|((( 936 936 Operation setting 937 937 )))|((( 938 938 Effective immediately 939 939 )))|100|1 to 5000|Steady-state running speed of the 1st segment|rpm 940 -| =P07-11|Acceleration and deceleration of 1st segment displacement|(((950 +|P07-11|Acceleration and deceleration of 1st segment displacement|((( 941 941 Operation setting 942 942 )))|((( 943 943 Effective immediately 944 944 )))|100|1 to 65535|The time required for the acceleration and deceleration of the 1st segment|ms 945 -| =P07-12|Waiting time after completion of the 1st segment displacement|(((955 +|P07-12|Waiting time after completion of the 1st segment displacement|((( 946 946 Operation setting 947 947 )))|((( 948 948 Effective immediately ... ... @@ -962,8 +962,8 @@ 962 962 When selecting multi-segment position instruction as the instruction source, configure 1 DI port channel of the servo drive to function 20 (internal multi-segment position enable signal), and confirm the valid logic of the DI terminal. 963 963 964 964 965 -| =(% scope="row" %)**DI function code**|=**Function name**|=**Function**966 -| =20|ENINPOS: Internal multi-segment position enable signal|(((975 +|**DI function code**|**Function name**|**Function** 976 +|20|ENINPOS: Internal multi-segment position enable signal|((( 967 967 DI port logic invalid: Does not affect the current operation of the servo motor. 968 968 969 969 DI port logic valid: Motor runs multi-segment position ... ... @@ -1020,12 +1020,12 @@ 1020 1020 When the function code P00-16 is 0, the electronic gear ratio switching function could be used. You could switch between electronic gear 1 and electronic gear 2 as needed. There is only one set of gear ratios at any time. Related function codes are shown in the table below. 1021 1021 1022 1022 1023 -| =(% scope="row" %)**Function code**|=**Name**|=(((1033 +|**Function code**|**Name**|((( 1024 1024 **Setting method** 1025 -)))| =(((1035 +)))|((( 1026 1026 **Effective time** 1027 -)))| =**Default value**|=**Range**|=**Definition**|=**Unit**1028 -| =P00-16|Number of instruction pulses when the motor rotates one circle|(((1037 +)))|**Default value**|**Range**|**Definition**|**Unit** 1038 +|P00-16|Number of instruction pulses when the motor rotates one circle|((( 1029 1029 Shutdown setting 1030 1030 )))|((( 1031 1031 Effective immediately ... ... @@ -1034,7 +1034,7 @@ 1034 1034 1035 1035 unit 1036 1036 ))) 1037 -| =P00-17|(((1047 +|P00-17|((( 1038 1038 Electronic gear 1 1039 1039 1040 1040 numerator ... ... @@ -1041,7 +1041,7 @@ 1041 1041 )))|Operation setting|((( 1042 1042 Effective immediately 1043 1043 )))|1|1 to 4294967294|Set the numerator of the 1st group electronic gear ratio for position instruction frequency division or multiplication. P00-16 is effective when the number of instruction pulses of one motor rotation is 0.|- 1044 -| =P00-18|(((1054 +|P00-18|((( 1045 1045 Electronic gear 1 1046 1046 1047 1047 denominator ... ... @@ -1050,7 +1050,7 @@ 1050 1050 )))|((( 1051 1051 Effective immediately 1052 1052 )))|1|1 to 4294967294|Set the denominator of the 1st group electronic gear ratio for position instruction frequency division or multiplication. P00-16 is effective when the number of instruction pulses of one motor rotation is 0.|- 1053 -| =P00-19|(((1063 +|P00-19|((( 1054 1054 Electronic gear 2 1055 1055 1056 1056 numerator ... ... @@ -1057,7 +1057,7 @@ 1057 1057 )))|Operation setting|((( 1058 1058 Effective immediately 1059 1059 )))|1|1 to 4294967294|Set the numerator of the 2nd group electronic gear ratio for position instruction frequency division or multiplication. P00-16 is effective when the number of instruction pulses of one motor rotation is 0.|- 1060 -| =P00-20|(((1070 +|P00-20|((( 1061 1061 Electronic gear 2 1062 1062 1063 1063 denominator ... ... @@ -1070,8 +1070,8 @@ 1070 1070 To use electronic gear ratio 2, it is necessary to configure any DI port as function 09 (GEAR-SEL electronic gear switch 1), and determine the valid logic of the DI terminal. 1071 1071 1072 1072 1073 -| =(% scope="row" %)**DI function code**|=**Function name**|=**Function**1074 -| =09|GEAR-SEL electronic gear switch 1|(((1083 +|**DI function code**|**Function name**|**Function** 1084 +|09|GEAR-SEL electronic gear switch 1|((( 1075 1075 DI port logic invalid: electronic gear ratio 1 1076 1076 1077 1077 DI port logic valid: electronic gear ratio 2 ... ... @@ -1079,10 +1079,10 @@ 1079 1079 1080 1080 Table 6-21 Switching conditions of electronic gear ratio group 1081 1081 1082 -| =(% scope="row" %)**P00-16 value**|=**DI terminal level corresponding to DI port function 9**|=**Electronic gear ratio**[[image:https://docs.we-con.com.cn/bin/download/Servo/2.%20User%20Manual/06%20VD2%20SA%20Series%20Servo%20Drives%20Manual%20%28Full%20V1.1%29/06%20Operation/WebHome/39.png?rev=1.1]]1083 -| =(% rowspan="2" %)0|DI port logic invalid|[[image:https://docs.we-con.com.cn/bin/download/Servo/2.%20User%20Manual/06%20VD2%20SA%20Series%20Servo%20Drives%20Manual%20%28Full%20V1.1%29/06%20Operation/WebHome/40.png?rev=1.1]]1084 -| =DI port logic valid|[[image:https://docs.we-con.com.cn/bin/download/Servo/2.%20User%20Manual/06%20VD2%20SA%20Series%20Servo%20Drives%20Manual%20%28Full%20V1.1%29/06%20Operation/WebHome/41.png?rev=1.1]]1085 -| =1 to 131072|~-~-|[[image:https://docs.we-con.com.cn/bin/download/Servo/2.%20User%20Manual/06%20VD2%20SA%20Series%20Servo%20Drives%20Manual%20%28Full%20V1.1%29/06%20Operation/WebHome/42.png?rev=1.1]]1092 +|**P00-16 value**|**DI terminal level corresponding to DI port function 9**|**Electronic gear ratio**[[image:https://docs.we-con.com.cn/bin/download/Servo/2.%20User%20Manual/06%20VD2%20SA%20Series%20Servo%20Drives%20Manual%20%28Full%20V1.1%29/06%20Operation/WebHome/39.png?rev=1.1]] 1093 +|(% rowspan="2" %)0|DI port logic invalid|[[image:https://docs.we-con.com.cn/bin/download/Servo/2.%20User%20Manual/06%20VD2%20SA%20Series%20Servo%20Drives%20Manual%20%28Full%20V1.1%29/06%20Operation/WebHome/40.png?rev=1.1]] 1094 +|DI port logic valid|[[image:https://docs.we-con.com.cn/bin/download/Servo/2.%20User%20Manual/06%20VD2%20SA%20Series%20Servo%20Drives%20Manual%20%28Full%20V1.1%29/06%20Operation/WebHome/41.png?rev=1.1]] 1095 +|1 to 131072|~-~-|[[image:https://docs.we-con.com.cn/bin/download/Servo/2.%20User%20Manual/06%20VD2%20SA%20Series%20Servo%20Drives%20Manual%20%28Full%20V1.1%29/06%20Operation/WebHome/42.png?rev=1.1]] 1086 1086 1087 1087 Table 6-22 Application of electronic gear ratio 1088 1088 ... ... @@ -1106,12 +1106,12 @@ 1106 1106 Figure 6-25 Position instruction filtering diagram 1107 1107 1108 1108 1109 -| =(% scope="row" %)**Function code**|=**Name**|=(((1119 +|**Function code**|**Name**|((( 1110 1110 **Setting method** 1111 -)))| =(((1121 +)))|((( 1112 1112 **Effective time** 1113 -)))| =**Default value**|=**Range**|=**Definition**|=**Unit**1114 -| =P04-01|Pulse instruction filtering method|(((1123 +)))|**Default value**|**Range**|**Definition**|**Unit** 1124 +|P04-01|Pulse instruction filtering method|((( 1115 1115 Shutdown setting 1116 1116 )))|((( 1117 1117 Effective immediately ... ... @@ -1120,10 +1120,10 @@ 1120 1120 1121 1121 1: average filtering 1122 1122 )))|- 1123 -| =P04-02|Position instruction 1st-order low-pass filtering time constant|Shutdown setting|(((1133 +|P04-02|Position instruction 1st-order low-pass filtering time constant|Shutdown setting|((( 1124 1124 Effective immediately 1125 1125 )))|0|0 to 1000|Position instruction first-order low-pass filtering time constant|ms 1126 -| =P04-03|Position instruction average filtering time constant|Shutdown setting|(((1136 +|P04-03|Position instruction average filtering time constant|Shutdown setting|((( 1127 1127 Effective immediately 1128 1128 )))|0|0 to 128|Position instruction average filtering time constant|ms 1129 1129 ... ... @@ -1152,34 +1152,35 @@ 1152 1152 1153 1153 When using the positioning completion or approach function, you could also set positioning completion, positioning approach conditions, window and hold time. The principle of window filter time is shown in Figure 6-27. 1154 1154 1155 -To use the positioning completion/positioning approach function, a DO terminal of the servo drive should be assigned to the function 134 (P-COIN, positioning completion)/ 135 (P-NEAR, positioning approach). The related code parameters and DO function codes are shown as __[[Table 6-24>>http s://docs.we-con.com.cn/bin/view/Servo/2.%20User%20Manual/06%20VD2%20SA%20Series%20Servo%20Drives%20Manual%20%28Full%20V1.1%29/06%20Operation/#HPosition-relatedDOoutputfunction]]__.1165 +To use the positioning completion/positioning approach function, a DO terminal of the servo drive should be assigned to the function 134 (P-COIN, positioning completion)/ 135 (P-NEAR, positioning approach). The related code parameters and DO function codes are shown as __[[Table 6-24>>http://13.229.109.52:8080/wiki/servo/view/2.%20User%20Manual/06%20VD2%20SA%20Series%20Servo%20Drives%20Manual%20(Full%20V1.1)/06%20Operation/#HPosition-relatedDOoutputfunction]]__. 1156 1156 1167 + 1157 1157 [[image:image-20220608170650-25.png]] 1158 1158 1159 1159 Figure 6-27 Positioning completion signal output with increased window filter time diagram 1160 1160 1161 1161 1162 -| =(% scope="row" %)**Function code**|=**Name**|=(((1173 +|**Function code**|**Name**|((( 1163 1163 **Setting method** 1164 -)))| =(((1175 +)))|((( 1165 1165 **Effective time** 1166 -)))| =**Default value**|=**Range**|=**Definition**|=**Unit**1167 -| =P05-12|Positioning completion threshold|(((1177 +)))|**Default value**|**Range**|**Definition**|**Unit** 1178 +|P05-12|Positioning completion threshold|((( 1168 1168 Operation setting 1169 1169 )))|((( 1170 1170 Effective immediately 1171 1171 )))|800|1 to 65535|Positioning completion threshold|Equivalent pulse unit 1172 -| =P05-13|Positioning approach threshold|(((1183 +|P05-13|Positioning approach threshold|((( 1173 1173 Operation setting 1174 1174 )))|((( 1175 1175 Effective immediately 1176 1176 )))|5000|1 to 65535|Positioning approach threshold|Equivalent pulse unit 1177 -| =P05-14|Position detection window time|(((1188 +|P05-14|Position detection window time|((( 1178 1178 Operation setting 1179 1179 )))|((( 1180 1180 Effective immediately 1181 1181 )))|10|0 to 20000|Set positioning completion detection window time|ms 1182 -| =P05-15|Positioning signal hold time|(((1193 +|P05-15|Positioning signal hold time|((( 1183 1183 Operation setting 1184 1184 )))|((( 1185 1185 Effective immediately ... ... @@ -1188,9 +1188,9 @@ 1188 1188 Table 6-24 Function code parameters of positioning completion 1189 1189 1190 1190 1191 -| =(% scope="row" %)**DO function code**|=**Function name**|=**Function**1192 -| =134|P-COIN positioning complete|Output this signal indicates the servo drive position is complete.1193 -| =135|(((1202 +|**DO function code**|**Function name**|**Function** 1203 +|134|P-COIN positioning complete|Output this signal indicates the servo drive position is complete. 1204 +|135|((( 1194 1194 P-NEAR positioning close 1195 1195 )))|((( 1196 1196 Output this signal indicates that the servo drive position is close. ... ... @@ -1200,7 +1200,7 @@ 1200 1200 1201 1201 = **Speed control mode** = 1202 1202 1203 -Speed control refers to controlling the speed of the machine through speed instructions. Given the speed instruction by digital voltage or communication, the servo drive can control the mechanical speed fast and precisely. Therefore, the speed control mode is mainly used to control the rotation speed such as analog CNC engraving and milling machine. [[Figure 6-28>>path:http s://docs.we-con.com.cn/bin/download/Servo/2.%20User%20Manual/06%20VD2%20SA%20Series%20Servo%20Drives%20Manual%20%28Full%20V1.1%29/06%20Operation/WebHome/6.28.jpg?width=806&height=260&rev=1.1]] is the speed control block diagram.1214 +Speed control refers to controlling the speed of the machine through speed instructions. Given the speed instruction by digital voltage or communication, the servo drive can control the mechanical speed fast and precisely. Therefore, the speed control mode is mainly used to control the rotation speed such as analog CNC engraving and milling machine. [[Figure 6-28>>path:http://13.229.109.52:8080/wiki/servo/download/2.%20User%20Manual/06%20VD2%20SA%20Series%20Servo%20Drives%20Manual%20%28Full%20V1.1%29/06%20Operation/WebHome/6.28.jpg?width=806&height=260&rev=1.1]] is the speed control block diagram. 1204 1204 1205 1205 1206 1206 [[image:6.28.jpg||height="260" width="806"]] ... ... @@ -1600,7 +1600,7 @@ 1600 1600 1601 1601 Figure 6-35 Rotation detection signal diagram 1602 1602 1603 -To use the motor rotation detection signal output function, a DO terminal of the servo drive should be assigned to function 132 (T-COIN, rotation detection). The function code parameters and related DO function codes are shown in __[[Table 6-34>>http s://docs.we-con.com.cn/bin/view/Servo/2.%20User%20Manual/06%20VD2%20SA%20Series%20Servo%20Drives%20Manual%20%28Full%20V1.1%29/06%20Operation/#HSpeed-relatedDOoutputfunction]]__ and __[[Table 6-35>>https://docs.we-con.com.cn/bin/view/Servo/2.%20User%20Manual/06%20VD2%20SA%20Series%20Servo%20Drives%20Manual%20%28Full%20V1.1%29/06%20Operation/#HSpeed-relatedDOoutputfunction]]__.1614 +To use the motor rotation detection signal output function, a DO terminal of the servo drive should be assigned to function 132 (T-COIN, rotation detection). The function code parameters and related DO function codes are shown in __[[Table 6-34>>http://13.229.109.52:8080/wiki/servo/view/2.%20User%20Manual/06%20VD2%20SA%20Series%20Servo%20Drives%20Manual%20(Full%20V1.1)/06%20Operation/#HZero-speedclampfunction]]__ and __[[Table 6-35>>http://13.229.109.52:8080/wiki/servo/view/2.%20User%20Manual/06%20VD2%20SA%20Series%20Servo%20Drives%20Manual%20(Full%20V1.1)/06%20Operation/#HZero-speedclampfunction]]__. 1604 1604 1605 1605 1606 1606 |**Function code**|**Name**|((( ... ... @@ -1641,7 +1641,7 @@ 1641 1641 1642 1642 Figure 6-36 Zero-speed signal diagram 1643 1643 1644 -To use the motor zero-speed signal output function, a DO terminal of servo drive should be assigned to function 133 (ZSP, zero-speed signal). The function code parameters and related DO function codes are shown in __[[Table 6-36>>http s://docs.we-con.com.cn/bin/view/Servo/2.%20User%20Manual/06%20VD2%20SA%20Series%20Servo%20Drives%20Manual%20%28Full%20V1.1%29/06%20Operation/#HSpeed-relatedDOoutputfunction]]__ and __[[Table 6-37>>https://docs.we-con.com.cn/bin/view/Servo/2.%20User%20Manual/06%20VD2%20SA%20Series%20Servo%20Drives%20Manual%20%28Full%20V1.1%29/06%20Operation/#HSpeed-relatedDOoutputfunction]]__.1655 +To use the motor zero-speed signal output function, a DO terminal of servo drive should be assigned to function 133 (ZSP, zero-speed signal). The function code parameters and related DO function codes are shown in __[[Table 6-36>>http://13.229.109.52:8080/wiki/servo/view/2.%20User%20Manual/06%20VD2%20SA%20Series%20Servo%20Drives%20Manual%20(Full%20V1.1)/06%20Operation/#HZero-speedclampfunction]]__ and __[[Table 6-37>>http://13.229.109.52:8080/wiki/servo/view/2.%20User%20Manual/06%20VD2%20SA%20Series%20Servo%20Drives%20Manual%20(Full%20V1.1)/06%20Operation/#HZero-speedclampfunction]]__. 1645 1645 1646 1646 1647 1647 |**Function code**|**Name**|((( ... ... @@ -1674,7 +1674,7 @@ 1674 1674 1675 1675 Figure 6-37 Speed consistent signal diagram 1676 1676 1677 -To use the motor speed consistent function, a DO terminal of the servo drive should be assigned to function 136 (V-COIN, consistent speed). The function code parameters and related DO function codes are shown in __[[Table 6-38>>http s://docs.we-con.com.cn/bin/view/Servo/2.%20User%20Manual/06%20VD2%20SA%20Series%20Servo%20Drives%20Manual%20%28Full%20V1.1%29/06%20Operation/#HSpeed-relatedDOoutputfunction]]__ and __[[Table 6-39>>https://docs.we-con.com.cn/bin/view/Servo/2.%20User%20Manual/06%20VD2%20SA%20Series%20Servo%20Drives%20Manual%20%28Full%20V1.1%29/06%20Operation/#HSpeed-relatedDOoutputfunction]]__.1688 +To use the motor speed consistent function, a DO terminal of the servo drive should be assigned to function 136 (V-COIN, consistent speed). The function code parameters and related DO function codes are shown in __[[Table 6-38>>http://13.229.109.52:8080/wiki/servo/view/2.%20User%20Manual/06%20VD2%20SA%20Series%20Servo%20Drives%20Manual%20(Full%20V1.1)/06%20Operation/#HZero-speedclampfunction]]__ and __[[Table 6-39>>http://13.229.109.52:8080/wiki/servo/view/2.%20User%20Manual/06%20VD2%20SA%20Series%20Servo%20Drives%20Manual%20(Full%20V1.1)/06%20Operation/#HZero-speedclampfunction]]__. 1678 1678 1679 1679 1680 1680 |**Function code**|**Name**|((( ... ... @@ -1707,7 +1707,7 @@ 1707 1707 1708 1708 Figure 6-38 Speed approaching signal diagram 1709 1709 1710 -To use the motor speed approach function, a DO terminal of the servo drive should be assigned to function 137 (V-NEAR, speed approach). The function code parameters and related DO function codes are shown in __[[Table 6-40>>http s://docs.we-con.com.cn/bin/view/Servo/2.%20User%20Manual/06%20VD2%20SA%20Series%20Servo%20Drives%20Manual%20%28Full%20V1.1%29/06%20Operation/#HSpeed-relatedDOoutputfunction]]__ and __[[Table 6-40>>https://docs.we-con.com.cn/bin/view/Servo/2.%20User%20Manual/06%20VD2%20SA%20Series%20Servo%20Drives%20Manual%20%28Full%20V1.1%29/06%20Operation/#HSpeed-relatedDOoutputfunction]]__.1721 +To use the motor speed approach function, a DO terminal of the servo drive should be assigned to function 137 (V-NEAR, speed approach). The function code parameters and related DO function codes are shown in __[[Table 6-40>>http://13.229.109.52:8080/wiki/servo/view/2.%20User%20Manual/06%20VD2%20SA%20Series%20Servo%20Drives%20Manual%20(Full%20V1.1)/06%20Operation/#HZero-speedclampfunction]]__ and __[[Table 6-40>>http://13.229.109.52:8080/wiki/servo/view/2.%20User%20Manual/06%20VD2%20SA%20Series%20Servo%20Drives%20Manual%20(Full%20V1.1)/06%20Operation/#HZero-speedclampfunction]]__. 1711 1711 1712 1712 1713 1713 |**Function code**|**Name**|((( ... ... @@ -1927,7 +1927,7 @@ 1927 1927 1928 1928 In torque mode, if the given torque instruction is too large to exceed the load torque of the mechanical side. This would cause the servo motor to continuously accelerate and overspeed. In order to protect the machinery, the speed of the motor must be limited. 1929 1929 1930 -In torque mode, the actual motor speed would be in the limited speed. After the speed limit is reached, the motor runs at a constant speed at the speed limit. The running curves are shown as __[[Figure 6-45>>http s://docs.we-con.com.cn/bin/view/Servo/2.%20User%20Manual/06%20VD2%20SA%20Series%20Servo%20Drives%20Manual%20%28Full%20V1.1%29/06%20Operation/#HSpeedlimitintorquemode]]__ and __[[Figure 6-46>>https://docs.we-con.com.cn/bin/view/Servo/2.%20User%20Manual/06%20VD2%20SA%20Series%20Servo%20Drives%20Manual%20%28Full%20V1.1%29/06%20Operation/#HSpeedlimitintorquemode]]__.1941 +In torque mode, the actual motor speed would be in the limited speed. After the speed limit is reached, the motor runs at a constant speed at the speed limit. The running curves are shown as __[[Figure 6-45>>http://docs.we-con.com.cn/wiki/servo/download/2.%20User%20Manual/06%20VD2%20SA%20Series%20Servo%20Drives%20Manual%20%28Full%20V1.1%29/WebHome/Wecon%20VD2%20SA%20Series%20Servo%20Drives%20Manual%20%28Full%20V1.1%29_html_e1eced3568bc22d7.gif?rev=1.1]]__ and __[[Figure 6-46>>http://docs.we-con.com.cn/wiki/servo/download/2.%20User%20Manual/06%20VD2%20SA%20Series%20Servo%20Drives%20Manual%20%28Full%20V1.1%29/WebHome/Wecon%20VD2%20SA%20Series%20Servo%20Drives%20Manual%20%28Full%20V1.1%29_html_79d479af8534745f.gif?rev=1.1]]__. 1931 1931 1932 1932 |((( 1933 1933 [[image:image-20220608172910-40.png]] ... ... @@ -1970,7 +1970,7 @@ 1970 1970 1971 1971 Table 6-48 Speed limit parameters in torque mode 1972 1972 1973 -✎**Note:** Function codes P01-17 and P01-18 are only effective in limiting motor speed under the torque mode. The speed limit value is set according to load requirements. To set speed limit in speed mode or position mode, please refer to __[[6.3.3 Speed instruction limit>>http s://docs.we-con.com.cn/bin/view/Servo/2.%20User%20Manual/06%20VD2%20SA%20Series%20Servo%20Drives%20Manual%20%28Full%20V1.1%29/06%20Operation/#HSpeedinstructionlimit]]__.1984 +✎**Note:** Function codes P01-17 and P01-18 are only effective in limiting motor speed under the torque mode. The speed limit value is set according to load requirements. To set speed limit in speed mode or position mode, please refer to __[[6.3.3 Speed instruction limit>>http://13.229.109.52:8080/wiki/servo/view/2.%20User%20Manual/06%20VD2%20SA%20Series%20Servo%20Drives%20Manual%20(Full%20V1.1)/06%20Operation/#HSpeedinstructionlimit]]__. 1974 1974 1975 1975 == **Torque-related DO output functions** == 1976 1976 ... ... @@ -1985,7 +1985,7 @@ 1985 1985 1986 1986 Figure 6-47 Torque arrival output diagram 1987 1987 1988 -To use the torque arrival function, a DO terminal of the servo drive should be assigned to function 138 (T-COIN, torque arrival). The function code parameters and related DO function codes are shown in __[[Table 6-49>>http s://docs.we-con.com.cn/bin/view/Servo/2.%20User%20Manual/06%20VD2%20SA%20Series%20Servo%20Drives%20Manual%20%28Full%20V1.1%29/06%20Operation/#HTorque-relatedDOoutputfunctions]]__ and __[[Table 6-50>>https://docs.we-con.com.cn/bin/view/Servo/2.%20User%20Manual/06%20VD2%20SA%20Series%20Servo%20Drives%20Manual%20%28Full%20V1.1%29/06%20Operation/#HTorque-relatedDOoutputfunctions]]__.1999 +To use the torque arrival function, a DO terminal of the servo drive should be assigned to function 138 (T-COIN, torque arrival). The function code parameters and related DO function codes are shown in __[[Table 6-49>>http://13.229.109.52:8080/wiki/servo/view/2.%20User%20Manual/06%20VD2%20SA%20Series%20Servo%20Drives%20Manual%20(Full%20V1.1)/06%20Operation/#HTorque-relatedDOoutputfunctions]]__ and __[[Table 6-50>>http://13.229.109.52:8080/wiki/servo/view/2.%20User%20Manual/06%20VD2%20SA%20Series%20Servo%20Drives%20Manual%20(Full%20V1.1)/06%20Operation/#HTorque-relatedDOoutputfunctions]]__. 1989 1989 1990 1990 1991 1991 |**Function code**|**Name**|((( ... ... @@ -2066,7 +2066,7 @@ 2066 2066 2067 2067 Table 6-51 Mixed control mode parameters 2068 2068 2069 -Please set the servo drive parameters in different control modes according to the mechanical structure and indicators. The setting method refer to [[__“Parameters”__>>http s://docs.we-con.com.cn/bin/view/Servo/2.%20User%20Manual/06%20VD2%20SA%20Series%20Servo%20Drives%20Manual%20%28Full%20V1.1%29/09%20Parameters/]]. When function code P00-01=4/5/6 (that is, in mixed mode), a DI terminal of the servo drive needs to be assigned to function 17 (MixModeSel, mixed mode selection), and the DI terminal logic is determined to be valid.2080 +Please set the servo drive parameters in different control modes according to the mechanical structure and indicators. The setting method refer to [[__“Parameters”__>>url:http://docs.we-con.com.cn/wiki/servo/view/2.%20User%20Manual/06%20VD2%20SA%20Series%20Servo%20Drives%20Manual%20%28Full%20V1.1%29/#_Chapter%209%20Parameters]]. When function code P00-01=4/5/6 (that is, in mixed mode), a DI terminal of the servo drive needs to be assigned to function 17 (MixModeSel, mixed mode selection), and the DI terminal logic is determined to be valid. 2070 2070 2071 2071 2072 2072 |**DI function code**|**Name**|**Function name**|**Function**