Changes for page 06 Operation
Last modified by Iris on 2025/07/23 15:49
Summary
-
Page properties (1 modified, 0 added, 0 removed)
-
Attachments (0 modified, 0 added, 2 removed)
Details
- Page properties
-
- Content
-
... ... @@ -1327,7 +1327,7 @@ 1327 1327 1328 1328 Select this speed instruction to be effective. 1329 1329 )))|(% colspan="2" %)rpm 1330 -|P01-26|(% colspan="2" %)((( 1330 +|(% colspan="2" %)P01-26|(% colspan="2" %)((( 1331 1331 Internal speed 1332 1332 1333 1333 Instruction 4 ... ... @@ -1339,7 +1339,7 @@ 1339 1339 Effective 1340 1340 1341 1341 immediately 1342 -)))|(% colspan="2" %)0|(% colspan="2" %)-5000 to 5000|(% colspan="2" %)((( 1342 +)))|(% colspan="2" %)0|(% colspan="2" %)-5000 to 5000*|(% colspan="2" %)((( 1343 1343 Internal speed instruction 4 1344 1344 1345 1345 When DI input port: ... ... @@ -1352,7 +1352,7 @@ 1352 1352 1353 1353 Select this speed instruction to be effective. 1354 1354 )))|(% colspan="1" %)rpm 1355 -|P01-27|(% colspan="2" %)((( 1355 +|(% colspan="2" %)P01-27|(% colspan="2" %)((( 1356 1356 Internal speed 1357 1357 1358 1358 Instruction 5 ... ... @@ -1377,7 +1377,7 @@ 1377 1377 1378 1378 Select this speed instruction to be effective. 1379 1379 )))|(% colspan="1" %)rpm 1380 -|P01-28|(% colspan="2" %)((( 1380 +|(% colspan="2" %)P01-28|(% colspan="2" %)((( 1381 1381 Internal speed 1382 1382 1383 1383 Instruction 6 ... ... @@ -1402,7 +1402,7 @@ 1402 1402 1403 1403 Select this speed instruction to be effective. 1404 1404 )))|(% colspan="1" %)rpm 1405 -|P01-29|(% colspan="2" %)((( 1405 +|(% colspan="2" %)P01-29|(% colspan="2" %)((( 1406 1406 Internal speed 1407 1407 1408 1408 Instruction 7 ... ... @@ -1430,6 +1430,9 @@ 1430 1430 1431 1431 Table 6-27 Internal speed instruction parameters 1432 1432 1433 +✎**Note: **“*” means the set range of VD2F servo drive. 1434 + 1435 + 1433 1433 |**DI function code**|**function name**|**Function** 1434 1434 |13|INSPD1 internal speed instruction selection 1|Form internal multi-speed running segment number 1435 1435 |14|INSPD2 internal speed instruction selection 2|Form internal multi-speed running segment number ... ... @@ -1449,15 +1449,16 @@ 1449 1449 1450 1450 Table 6-29 Correspondence between INSPD bits and segment numbers 1451 1451 1455 + 1452 1452 [[image:image-20220608170845-26.png]] 1453 1453 1454 1454 Figure 6-29 Multi-segment speed running curve 1455 1455 1456 -**(2) Speed instruction source is internal speed instruction (P01-01= 1)**1460 +**(2) Speed instruction source is internal speed instruction (P01-01=0)** 1457 1457 1458 1458 The servo drive processes the analog voltage signal output by the host computer or other equipment as a speed instruction. VD2A and VD2B series servo drives have 2 analog input channels: AI_1 and AI_2. AI_1 is analog speed input, and AI_2 is analog speed limit. 1459 1459 1460 - (% style="text-align:center" %)1464 + 1461 1461 [[image:image-20220608153341-5.png]] 1462 1462 1463 1463 Figure 6-30 Analog input circuit ... ... @@ -1464,7 +1464,7 @@ 1464 1464 1465 1465 Taking AI_1 as an example, the method of setting the speed instruction of analog voltage is illustrated as below. 1466 1466 1467 - (% style="text-align:center" %)1471 + 1468 1468 [[image:image-20220608170955-27.png]] 1469 1469 1470 1470 Figure 6-31 Analog voltage speed instruction setting steps ... ... @@ -1471,15 +1471,18 @@ 1471 1471 1472 1472 Explanation of related terms: 1473 1473 1474 -* Zero drift: When analog input voltage is 0, the servo drive sample voltage value relative to the value of GND. 1475 -* Bias: After zero drift correction, the corresponding analog input voltage when the sample voltage is 0. 1476 -* Dead zone: It is the corresponding analog input voltage interval when the sample voltage is 0. 1478 +Zero drift: When analog input voltage is 0, the servo drive sample voltage value relative to the value of GND. 1477 1477 1478 -(% style="text-align:center" %) 1480 +Bias: After zero drift correction, the corresponding analog input voltage when the sample voltage is 0. 1481 + 1482 +Dead zone: It is the corresponding analog input voltage interval when the sample voltage is 0. 1483 + 1484 + 1479 1479 [[image:image-20220608171124-28.png]] 1480 1480 1481 1481 Figure 6-32 AI_1 diagram before and after bias 1482 1482 1489 + 1483 1483 |**Function code**|**Name**|**Setting method**|**Effective time**|**Default value**|**Range**|**Definition**|**Unit** 1484 1484 |P05-01☆|AI_1 input bias|Operation setting|Effective immediately|0|-5000 to 5000|Set AI_1 channel analog bias value|mV 1485 1485 |P05-02☆|AI_1 input filter time constant|Operation setting|Effective immediately|200|0 to 60000|AI_1 channel input first-order low-pass filtering time constant|0.01ms ... ... @@ -1496,14 +1496,16 @@ 1496 1496 1497 1497 In the speed control mode, excessive acceleration of the speed instruction will cause the motor to jump or vibrate. Therefore, a suitable acceleration and deceleration time can realize the smooth speed change of the motor and avoid the occurrence of mechanical damage caused by the above situation. 1498 1498 1499 - (% style="text-align:center" %)1506 + 1500 1500 [[image:image-20220608171314-29.png]] 1501 1501 1502 1502 Figure 6-33 of acceleration and deceleration time diagram 1503 1503 1504 -(% style="text-align:center" %) 1505 -[[image:image-20220707103616-27.png]] 1511 +Actual acceleration time T1 =[[image:https://docs.we-con.com.cn/bin/download/Servo/2.%20User%20Manual/06%20VD2%20SA%20Series%20Servo%20Drives%20Manual%20%28Full%20V1.1%29/06%20Operation/WebHome/43.jpg?rev=1.1]] 1506 1506 1513 +Actual deceleration time T2 =[[image:https://docs.we-con.com.cn/bin/download/Servo/2.%20User%20Manual/06%20VD2%20SA%20Series%20Servo%20Drives%20Manual%20%28Full%20V1.1%29/06%20Operation/WebHome/44.jpg?rev=1.1]] 1514 + 1515 + 1507 1507 |**Function code**|**Name**|((( 1508 1508 **Setting method** 1509 1509 )))|(((
- image-20220707103506-26.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.Stone - Size
-
... ... @@ -1,1 +1,0 @@ 1 -7.4 KB - Content
- image-20220707103616-27.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.Stone - Size
-
... ... @@ -1,1 +1,0 @@ 1 -7.3 KB - Content