Changes for page 06 Operation
Last modified by Iris on 2025/07/23 15:49
Summary
-
Page properties (1 modified, 0 added, 0 removed)
-
Attachments (0 modified, 1 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -2162,24 +2162,32 @@ 2162 2162 2163 2163 **✎Note: **Be sure to use the shield multi-turn absolute encoder battery fault function carefully, otherwise it may cause data loss, mechanical failure, or even personal injury or death. 2164 2164 2165 -== **Absolute value system encoder battery box use precautions** == 2165 +== **Absolute value system encoder battery box use precautions**. == 2166 2166 2167 - Er.40 (Encoder battery failure) will occur whenthe batteryis turnedonfor the first time, and the function code P10-03 must be set to 1 to clear the encoder fault to operate the absolute value system again.2167 +**Cautions** 2168 2168 2169 +Er.40 (Encoder battery failure) will occur when the battery is turned on for the first time, and the function code P10-03 must be set to 1 to clear the encoder fault to operate the absolute value system again. 2169 2169 2170 -[[image:https://docs.we-con.com.cn/bin/download/Servo/2.%20User%20Manual/06%20VD2%20SA%20Series%20Servo%20Drives%20Manual%20%28Full%20V1.1%29/06%20Operation/WebHome/45.jpg?rev=1.1||height="303" width="750"]] 2171 +(% style="text-align:center" %) 2172 +[[image:image-20220707111333-28.png]] 2171 2171 2172 -Figure 6-50 2174 +Figure 6-50 the encoder battery box 2173 2173 2174 -When it is detected that the battery voltage is less than 3.1V, A-92 (Encoder battery low voltage The specific replacement method is as follows:2176 +When it is detected that the battery voltage is less than 3.1V, A-92 (Encoder battery low voltage warning) will occur. Please replace the battery in time. 2175 2175 2176 -1. Step1 The servo drive is powered on and is in a non-operational state; 2177 -1. Step2 Replace the battery; 2178 -1. Step3 Set P10-03 to 1, and the drive will release A-92. It will run normally without other abnormal warnings. 2178 +**Replace the battery** 2179 2179 2180 - When theservodriveispoweredoff, ifthe battery is replacedand powered on again,Er.40 (encoderbatteryfailure)will occur,andthemulti-turndatawill changesuddenly. Pleaseset the functioncodeP10-03 or P10-06 to 1 tocleartheencoderfault alarms andperformthe origin returnfunctionoperation again.2180 +Please replace the battery while keeping the servo drive and motor well connected and the power on. 2181 2181 2182 +The specific replacement method is as follows: 2182 2182 2184 +* Step1 Push open the buckles on both ends of the outer cover of the battery compartment and open the outer cover. 2185 +* Step2 Remove the old battery. 2186 +* Step3 Embed the new battery, and the battery plug wire according to the anti-dull port on the battery box for placement. 2187 +* Step4 Close the outer cover of the battery box, please be careful not to pinch the connector wiring when closing. 2188 + 2189 +When the servo drive is powered off, if the battery is replaced and powered on again, Er.40 (encoder battery failure) will occur, and the multi-turn data will change suddenly. Please set the function code P10-03 or P10-06 to 1 to clear the encoder fault alarms and perform the origin return function operation again. 2190 + 2183 2183 |**Function code**|**Name**|((( 2184 2184 **Setting method** 2185 2185 )))|(((
- image-20220707111333-28.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Stone - Size
-
... ... @@ -1,0 +1,1 @@ 1 +44.1 KB - Content