... ... @@ -2162,32 +2162,24 @@
2162 2162  
2163 2163  **✎Note: **Be sure to use the shield multi-turn absolute encoder battery fault function carefully, otherwise it may cause data loss, mechanical failure, or even personal injury or death.
2164 2164  
2165 -== **Absolute value system encoder battery box use precautions**. ==
2165 +== **Absolute value system encoder battery box use precautions** ==
2166 2166  
2167 -**Cautions**
2167 +Er.40 (Encoder battery failure) will occur when the battery is turned on for the first time, and the function code P10-03 must be set to 1 to clear the encoder fault to operate the absolute value system again.
2168 2168  
2169 -Er.40 (Encoder battery failure) will occur when the battery is turned on for the first time, and the function code P10-03 must be set to 1 to clear the encoder fault to operate the absolute value system again.
2170 2170  
2171 -(% style="text-align:center" %)
2172 -[[image:image-20220707111333-28.png]]
2170 +[[image:https://docs.we-con.com.cn/bin/download/Servo/2.%20User%20Manual/06%20VD2%20SA%20Series%20Servo%20Drives%20Manual%20%28Full%20V1.1%29/06%20Operation/WebHome/45.jpg?rev=1.1||height="303" width="750"]]
2173 2173  
2174 -Figure 6-50 the encoder battery box
2172 +Figure 6-50 the encoder battery box
2175 2175  
2176 -When it is detected that the battery voltage is less than 3.1V, A-92 (Encoder battery low voltage warning) will occur. Please replace the battery in time.
2174 +When it is detected that the battery voltage is less than 3.1V, A-92 (Encoder battery low voltage warning) will occur. Please replace the battery in time. The specific replacement method is as follows:
2177 2177  
2178 -**Replace the battery**
2176 +1. Step1 The servo drive is powered on and is in a non-operational state;
2177 +1. Step2 Replace the battery;
2178 +1. Step3 Set P10-03 to 1, and the drive will release A-92. It will run normally without other abnormal warnings.
2179 2179  
2180 -Please replace the battery while keeping the servo drive and motor well connected and the power on.
2180 +When the servo drive is powered off, if the battery is replaced and powered on again, Er.40 (encoder battery failure) will occur, and the multi-turn data will change suddenly. Please set the function code P10-03 or P10-06 to 1 to clear the encoder fault alarms and perform the origin return function operation again.
2181 2181  
2182 -The specific replacement method is as follows:
2183 2183  
2184 -* Step1 Push open the buckles on both ends of the outer cover of the battery compartment and open the outer cover.
2185 -* Step2 Remove the old battery.
2186 -* Step3 Embed the new battery, and the battery plug wire according to the anti-dull port on the battery box for placement.
2187 -* Step4 Close the outer cover of the battery box, please be careful not to pinch the connector wiring when closing.
2188 -
2189 -When the servo drive is powered off, if the battery is replaced and powered on again, Er.40 (encoder battery failure) will occur, and the multi-turn data will change suddenly. Please set the function code P10-03 or P10-06 to 1 to clear the encoder fault alarms and perform the origin return function operation again.
2190 -
2191 2191  |**Function code**|**Name**|(((
2192 2192  **Setting method**
2193 2193  )))|(((
image-20220707111333-28.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Stone
Size
... ... @@ -1,1 +1,0 @@
1 -44.1 KB
Content