Changes for page 06 Operation
Last modified by Iris on 2025/08/05 17:31
Summary
-
Page properties (1 modified, 0 added, 0 removed)
-
Attachments (0 modified, 5 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -2207,12 +2207,36 @@ 2207 2207 2208 2208 Table 6-56 Absolute encoder reset enable parameter 2209 2209 2210 - ✎**Note: **If the batteryisreplaced when the servo drive is powered off, the encoder data will be lost.2210 +**Battery selection** 2211 2211 2212 +|(% style="width:361px" %)**Battery selection specification**|(% style="width:496px" %)**Item**|(% style="width:219px" %)**Value** 2213 +|(% rowspan="4" style="width:361px" %)((( 2214 +Nominal Voltage: 3.6V 2215 + 2216 +Nominal capacity: 2700mAh 2217 +)))|(% style="width:496px" %)Standard battery voltage (V)|(% style="width:219px" %)3.6 2218 +|(% style="width:496px" %)Standard cell voltage (V)|(% style="width:219px" %)3.1 2219 +|(% style="width:496px" %)Battery ambient temperature range|(% style="width:219px" %)0 to 40 2220 +|(% style="width:496px" %)Battery storage ambient temperature range|(% style="width:219px" %)-20 to 60 2221 + 2222 +Table 6-57 Absolute value encoder battery information 2223 + 2224 +**✎Note: ** 2225 + 2226 +If the battery is replaced when the servo drive is powered off, the encoder data will be lost. 2227 + 2212 2212 When the servo drive is powered off, please ensure that the maximum speed of motor does not exceed 3000 rpm to ensure that the encoder position information is accurately recorded. Please store the storage device according to the specified ambient temperature, and ensure that the encoder battery has reliable contact and sufficient power, otherwise the encoder position information may be lost. 2213 2213 2214 - =**Overview**=2230 +Correct placement of batteries +, - direction 2215 2215 2232 +1. Do not disassemble the battery or put the battery into the fire! If the battery is put into the fire or heated, there is a risk of explosion! 2233 +1. This battery cannot be charged. 2234 +1. If the battery is left inside the machine after a long period of use or the battery is no longer usable, liquid may leak out, etc. Please replace it as soon as possible! (Recommended to replace every 2 years, you can contact the manufacturer's technical staff for replacement) 2235 +1. Do not allow the battery to short-circuit or peel the battery skin! Otherwise, there may be a one-time outflow of high current, making the battery's power weakened, or even rupture. 2236 +1. After the replacement of the battery, please dispose of it according to local laws and regulations. 2237 + 2238 += **Other functions** = 2239 + 2216 2216 == **VDI** == 2217 2217 2218 2218 VDI (Virtual Digital Signal Input Port) is similar to hardware DI terminal. The DI function could also be assigned for use. ... ... @@ -2222,11 +2222,11 @@ 2222 2222 Take the VDI_1 terminal assignment forward drive prohibition (03-POT) as an example, and the use steps of VDI are as the figure below. 2223 2223 2224 2224 2249 +(% style="text-align:center" %) 2225 2225 [[image:image-20220608173804-46.png]] 2226 2226 2227 2227 Figure 6-51 VDI_1 setting steps 2228 2228 2229 - 2230 2230 |**Function code**|**Name**|((( 2231 2231 **Setting method** 2232 2232 )))|((( ... ... @@ -2314,9 +2314,9 @@ 2314 2314 VD2A and VD2B servo drives have 8 hardware DI terminals (DI_1 to DI_8) , and VD2F servo drive has 4 hardware DI terminals (DI_1 to DI_4) . All the DI terminals are normal terminals. 2315 2315 2316 2316 2317 -|**Setting value**|**DI channel logic selection**|**Illustration** 2318 -|0|Active high level|[[image: https://docs.we-con.com.cn/bin/download/Servo/2.%20User%20Manual/06%20VD2%20SA%20Series%20Servo%20Drives%20Manual%20%28Full%20V1.1%29/06%20Operation/WebHome/46.jpg?rev=1.1||height="97" width="307"]]2319 -|1|Active low level|[[image: https://docs.we-con.com.cn/bin/download/Servo/2.%20User%20Manual/06%20VD2%20SA%20Series%20Servo%20Drives%20Manual%20%28Full%20V1.1%29/06%20Operation/WebHome/47.jpg?rev=1.1||height="83" width="305"]]2341 +|(% style="width:204px" %)**Setting value**|(% style="width:235px" %)**DI channel logic selection**|(% style="width:637px" %)**Illustration** 2342 +|(% style="width:204px" %)0|(% style="width:235px" %)Active high level|(% style="width:637px" %)[[image:image-20220707113050-31.jpeg]] 2343 +|(% style="width:204px" %)1|(% style="width:235px" %)Active low level|(% style="width:637px" %)[[image:image-20220707113205-33.jpeg||height="166" width="526"]] 2320 2320 2321 2321 Table 6-58 DI terminal channel logic selection 2322 2322
- image-20220707112813-29.jpeg
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Stone - Size
-
... ... @@ -1,0 +1,1 @@ 1 +5.5 KB - Content
- image-20220707112819-30.jpeg
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Stone - Size
-
... ... @@ -1,0 +1,1 @@ 1 +5.9 KB - Content
- image-20220707113050-31.jpeg
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Stone - Size
-
... ... @@ -1,0 +1,1 @@ 1 +19.5 KB - Content
- image-20220707113057-32.jpeg
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Stone - Size
-
... ... @@ -1,0 +1,1 @@ 1 +10.4 KB - Content
- image-20220707113205-33.jpeg
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Stone - Size
-
... ... @@ -1,0 +1,1 @@ 1 +22.2 KB - Content