Changes for page 06 Operation
Last modified by Iris on 2026/04/17 16:03
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -894,24 +894,16 @@ 894 894 895 895 * Set multi-segment position running mode 896 896 897 -|**Function code**|**Name**|((( 898 -**Setting** 899 - 900 -**method** 897 +|=(% scope="row" %)**Function code**|=**Name**|=((( 898 +**Setting method** 899 +)))|=((( 900 +**Effective time** 901 +)))|=**Default value**|=**Range**|=**Definition**|=**Unit** 902 +|=P07-01|Multi-segment position running mode|((( 903 +Shutdown setting 901 901 )))|((( 902 -**Effective** 903 - 904 -**time** 905 -)))|**Default value**|**Range**|**Definition** 906 -|P07-01|Multi-segment position running mode|((( 907 -Shutdown 908 - 909 -setting 910 -)))|((( 911 -Effective 912 - 913 -immediately 914 -)))|0|0 to 3|((( 905 +Effective immediately 906 +)))|0|0 to 2|((( 915 915 0: Single running 916 916 917 917 1: Cycle running ... ... @@ -918,66 +918,37 @@ 918 918 919 919 2: DI switching running 920 920 921 -3: Run continuously 922 -))) 923 -|P07-02|Start segment number|((( 924 -Shutdown 925 - 926 -setting 913 +3: Run continuously 914 +)))|- 915 +|=P07-02|Start segment number|((( 916 +Shutdown setting 927 927 )))|((( 928 -Effective 929 - 930 -immediately 931 -)))|1|1 to 16|1st segment NO. in non-DI switching mode 932 -|P07-03|End segment number|((( 933 -Shutdown 934 - 935 -setting 918 +Effective immediately 919 +)))|1|1 to 16|1st segment NO. in non-DI switching mode|- 920 +|=P07-03|End segment number|((( 921 +Shutdown setting 936 936 )))|((( 937 -Effective 938 - 939 -immediately 940 -)))|1|1 to 16|last segment NO. in non-DI switching mode 941 -|P07-04|Remaining segment handling method|((( 942 -Shutdown 943 - 944 -setting 923 +Effective immediately 924 +)))|1|1 to 16|last segment NO. in non-DI switching mode|- 925 +|=P07-04|Remaining segment handling method|((( 926 +Shutdown setting 945 945 )))|((( 946 -Effective 947 - 948 -immediately 949 -)))|0|0 to 1|((( 928 +Effective immediately 929 +)))|0|0 to 1|((( 950 950 0: Run the remaining segments 951 951 952 -1: Run again from the start segment 953 -))) 954 -|P07-05|Displacement instruction type|((( 955 -Shutdown 956 - 957 -setting 932 +1: Run again from the start segment 933 +)))|- 934 +|=P07-05|Displacement instruction type|((( 935 +Shutdown setting 958 958 )))|((( 959 -Effective 937 +Effective immediately 938 +)))|0|0 to 1|((( 939 +(% id="cke_bm_79356S" style="display:none" %) (%%)0: Relative position instruction 960 960 961 -immediately 962 -)))|0|0 to 1|((( 963 -0: Relative position instruction 941 +1: Absolute position instruction(% id="cke_bm_79356E" style="display:none" %) 942 +)))|- 964 964 965 -1: Absolute position instruction 966 -))) 967 -|P07-07|Pulse remainder processing method|((( 968 -Shutdown 969 - 970 -setting 971 -)))|((( 972 -Effective 973 - 974 -immediately 975 -)))|0|0 to 1|((( 976 -0: Discard remaining pulses 977 - 978 -1: Execute remaining pulses 979 -))) 980 - 981 981 Table 6-18 multi-segment position running mode parameters 982 982 983 983 VD2 series servo drive has three multi-segment position running modes, and you could select the best running mode according to the site requirements.