Changes for page 06 Operation
Last modified by Iris on 2025/08/08 14:40
From version 61.1
edited by Jim(Forgotten)
on 2023/06/26 14:54
on 2023/06/26 14:54
Change comment:
There is no comment for this version
To version 60.1
edited by Jim(Forgotten)
on 2023/04/10 10:47
on 2023/04/10 10:47
Change comment:
There is no comment for this version
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -193,47 +193,8 @@ 193 193 194 194 **Emergency shutdown** 195 195 196 -It is free shutdown mode at present, and the motor shaft remains in a free state. The corresponding configuration and selection could be selected through the DI terminal function of the function code "DIDO configuration". The V1.18 firmware version adds the Estop stop time setting function. In some occasions where the servo needs to control the emergency stop of the motor, it is necessary to control the emergency stop time of the DI. Therefore, the P01-05 shutdown deceleration time function is added to deal with this situation.196 +It is free shutdown mode at present, and the motor shaft remains in a free state. The corresponding configuration and selection could be selected through the DI terminal function of the function code "DIDO configuration". 197 197 198 -Estop mode 1 (deceleration stop): 199 - 200 -~1. Configurate DI function code: 8 [ESTOP] 201 - 202 -2. Set P1-5 shutdown deceleration time. 203 - 204 -3. Trigger DI emergency shutdown. 205 - 206 -4. Servo emergency shutdown and deceleration to zero speed. 207 - 208 -Estop mode 2: 209 - 210 -~1. Configurate DI function code: 1 [Servo enable SON] 211 - 212 -2. Set P1-05 shutdown deceleration time. 213 - 214 -3. Set P0-05 Servo OFF shutdown mode: zero speed stop. 215 - 216 -4. Trigger DI to turn off servo enable SON. 217 - 218 -|Function code|Name|((( 219 -Setting 220 - 221 -method 222 -)))|((( 223 -Effective 224 - 225 -time 226 -)))|Default|Range|Definition|Unit 227 -|P01-05|Shutdown deceleration time|((( 228 -Shutdown 229 - 230 -setting 231 -)))|((( 232 -immediately 233 - 234 -Effective 235 -)))|50|0 to 65535|The time for the speed command to decelerate from 1000rpm to 0|ms 236 - 237 237 **Overtravel shutdown** 238 238 239 239 Overtravel means that the movable part of the machine exceeds the set area. In some occasions where the servo moves horizontally or vertically, it is necessary to limit the movement range of the workpiece. The overtravel is generally detected by limit switches, photoelectric switches or the multi-turn position of the encoder, that is, hardware overtravel or software overtravel. ... ... @@ -2177,51 +2177,6 @@ 2177 2177 [[**Figure 6-49 The relationship between encoder feedback position and rotating load position**>>image:image-20220608173701-44.png||id="Iimage-20220608173701-44.png"]] 2178 2178 ))) 2179 2179 2180 -(% class="wikigeneratedid" %) 2181 -((( 2182 -Multi-turn absolute value position U0-56 origin setting (only for multi-turn encoders) 2183 -Under the following two working conditions: 1. The current physical position of the motor cannot reach the 2184 -absolute zero point (U0-56). The value of U0-56 can be calibrated by moving the motor to the target position and setting the offset value of P10-8. 2. Move the motor to a known position on the machine and use this function to determine the position of U0-56. 2185 -P10-08 multi-turn absolute encoder origin offset compensation is used in conjunction with U0-56 multi-turn absolute encoder current position. When setting P10-06=1, the value of U0-56 is updated to the value of P10-8 multi-turn absolute value encoder origin offset compensation at the reset time. 2186 - 2187 -|**Function code**|**Name**|((( 2188 -**Setting** 2189 - 2190 -**method** 2191 -)))|((( 2192 -**Effective** 2193 - 2194 -**time** 2195 -)))|**Default**|**Range**|**Definition**|**Unit** 2196 -|P10-06|Multi-turn absolute encoder reset|((( 2197 -Shutdown 2198 - 2199 -setting 2200 -)))|Effective immediately|0|0 to 1|((( 2201 -0: No operation 2202 - 2203 -1: Clear rotation number of multi-turn absolute encoder, multi-turn absolute encoder current position and encoder fault alarms. 2204 - 2205 -**✎Note:** After resetting the multi-turn data of the encoder, the encoder absolute position will change suddenly, and the mechanical origin return operation is required. 2206 -)))|- 2207 - 2208 -(% style="background-color:#ffffff" %) 2209 -|**Function code**|**Name**|((( 2210 -**Setting** 2211 - 2212 -**method** 2213 -)))|((( 2214 -**Effective** 2215 - 2216 -**time** 2217 -)))|**Default**|**Range**|**Definition**|**Unit** 2218 -|P10-08|Multi-turn absolute encoder origin offset compensation|((( 2219 -Operation 2220 - 2221 -setting 2222 -)))|Effective immediately|0|-2147483647 to 2147483646|P10-08 multi-turn absolute encoder origin offset compensation is used in conjunction with U0-56 multi-turn absolute encoder current position. When P10-6 is set to 1, the value of U0-56 is updated to P10-8.|- 2223 -))) 2224 - 2225 2225 == Related functions and parameters == 2226 2226 2227 2227 **Encoder feedback data** ... ... @@ -2255,36 +2255,6 @@ 2255 2255 2256 2256 This function is permitted when a multi-turn absolute encoder motor is used as a single-turn absolute and when it is confirmed that no mechanical failure will occur. 2257 2257 2258 -**A93 warning solution** 2259 - 2260 -Check the encoder communication wire and its placement, reduce the abnormal frequency, and eliminate A93. In this way, the A93 warning problem can be completely solved, and the operation of the motor will not be affected after the A93 warning is released. 2261 -Increase the threshold for encoder read-write check exceptions is only suitable as a temporary solution. Eliminate A93 warning by increasing exception threshold. The disadvantage is that the motor may run in an unstable state. 2262 - 2263 -|**Function code**|**Name**|((( 2264 -**Setting** 2265 - 2266 -**method** 2267 -)))|((( 2268 -**Effective** 2269 - 2270 -**time** 2271 -)))|**Default**|**Range**|**Definition**|**Unit** 2272 -|P00-31|Encoder read-write check abnormal frequency|((( 2273 -Operation 2274 - 2275 -setting 2276 -)))|((( 2277 -immediately 2278 - 2279 -Effective 2280 -)))|20|0 to100|((( 2281 -The setting of the alarm threshold for the abnormal frequency of the encoder read-write 2282 - 2283 -0: no alarm 2284 - 2285 -Others: When this setting value is exceeded, report A93. 2286 -)))|- 2287 - 2288 2288 (% class="box infomessage" %) 2289 2289 ((( 2290 2290 **✎Note: **Be sure to use the shield multi-turn absolute encoder battery fault function carefully, otherwise it may cause data loss, mechanical failure, or even personal injury or death.