Changes for page 06 Operation
Last modified by Iris on 2025/08/08 14:40
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -112,13 +112,10 @@ 112 112 )))|(% style="width:126px" %)((( 113 113 Effective immediately 114 114 )))|0|0 to 3|((( 115 -0: use built-in braking resistor 116 - 117 -1: use external braking resistor and natural cooling 118 - 119 -2: use external braking resistor and forced air cooling; (cannot be set) 120 - 121 -3: No braking resistor is used, it is all absorbed by capacitor. 115 +* 0: use built-in braking resistor 116 +* 1: use external braking resistor and natural cooling 117 +* 2: use external braking resistor and forced air cooling; (cannot be set) 118 +* 3: No braking resistor is used, it is all absorbed by capacitor. 122 122 )))|- 123 123 (% class="info" %)|(% colspan="8" scope="row" %)✎**Note: **VD2-010SA1G and VD2F-010SA1P drives have no built-in resistor by default, so the default value of the function code “P00-09” is 3 (No braking resistor is used, it is all absorbed by capacitor). 124 124 |=P00-10|External braking resistor value|(% style="width:118px" %)((( ... ... @@ -159,7 +159,7 @@ 159 159 According to the different shutdown modes, it could be divided into free shutdown and zero speed shutdown. The respective characteristics are shown in __Table 6-5__. According to the shutdown status, it could be divided into free running state and position locked, as shown in __Table 6-6__. 160 160 161 161 |=(% scope="row" style="width: 150px;" %)Shutdown mode|=(% style="width: 532px;" %)Shutdown description|=(% style="width: 393px;" %)Shutdown characteristics 162 -|=(% style="width: 150px;" %)Free sto p|(% style="width:532px" %)Servo motor is not energized and decelerates freely to 0. The deceleration time is affected by factors such as mechanical inertia and mechanical friction.|(% style="width:393px" %)Smooth deceleration, small mechanical shock, but slow deceleration process.159 +|=(% style="width: 150px;" %)Free shutdown|(% style="width:532px" %)Servo motor is not energized and decelerates freely to 0. The deceleration time is affected by factors such as mechanical inertia and mechanical friction.|(% style="width:393px" %)Smooth deceleration, small mechanical shock, but slow deceleration process. 163 163 |=(% style="width: 150px;" %)Zero-speed shutdown|(% style="width:532px" %)The servo drive outputs reverse braking torque, and the motor quickly decelerates to zero-speed.|(% style="width:393px" %)Rapid deceleration with mechanical shock, but fast deceleration process. 164 164 165 165 Table 6-5 Comparison of two shutdown modes ... ... @@ -189,9 +189,8 @@ 189 189 190 190 immediately 191 191 )))|(% style="width:86px" %)0|(% style="width:70px" %)0 to 1|(% style="width:347px" %)((( 192 -0: Free stop, and the motor shaft remains free status. 193 - 194 -1: Zero-speed stop, and the motor axis remains free status. 189 +* 0: Free shutdown, and the motor shaft remains free status. 190 +* 1: Zero-speed shutdown, and the motor shaft remains free status. 195 195 )))|- 196 196 197 197 Table 6-7 Servo OFF shutdown mode parameters details ... ... @@ -253,58 +253,30 @@ 253 253 **Effective time** 254 254 )))|=(% style="width: 106px;" %)**Default value**|=(% style="width: 84px;" %)**Range**|=(% style="width: 380px;" %)**Definition**|=**Unit** 255 255 |=(% style="width: 89px;" %)P06-08|(% style="width:135px" %)DI_3 channel function selection|(% style="width:122px" %)Operation setting|(% style="width:114px" %)Power-on again|(% style="width:106px" %)3|(% style="width:84px" %)0 to 32|(% style="width:380px" %)((( 256 -0: OFF (not used) 257 - 258 -01: S-ON servo enable 259 - 260 -02: A-CLR fault and Warning Clear 261 - 262 -03: POT forward drive prohibition 263 - 264 -04: NOT Reverse drive prohibition 265 - 266 -05: ZCLAMP Zero speed 267 - 268 -06: CL Clear deviation counter 269 - 270 -07: C-SIGN Inverted instruction 271 - 272 -08: E-STOP Emergency stop 273 - 274 -09: GEAR-SEL Electronic Gear Switch 1 275 - 276 -10: GAIN-SEL gain switch 277 - 278 -11: INH Instruction pulse prohibited input 279 - 280 -12: VSSEL Vibration control switch input 281 - 282 -13: INSPD1 Internal speed instruction selection 1 283 - 284 -14: INSPD2 Internal speed instruction selection 2 285 - 286 -15: INSPD3 Internal speedinstruction selection 3 287 - 288 -16: J-SEL inertia ratio switch (not implemented yet) 289 - 290 -17: MixModesel mixed mode selection 291 - 292 -20: Internal multi-segment position enable signal 293 - 294 -21: Internal multi-segment position selection 1 295 - 296 -22: Internal multi-segment position selection 2 297 - 298 -23: Internal multi-segment position selection 3 299 - 300 -24: Internal multi-segment position selection 4 301 - 302 -25: HOME_START Homing start 303 -26: HOME ORG Homing signal 304 -27: JOGU DI Forward jog 305 -28: JOGD DI Reverse jog 306 - 307 -Others: reserved 252 +* 0: OFF (not used) 253 +* 01: S-ON servo enable 254 +* 02: A-CLR fault and Warning Clear 255 +* 03: POT forward drive prohibition 256 +* 04: NOT Reverse drive prohibition 257 +* 05: ZCLAMP Zero speed 258 +* 06: CL Clear deviation counter 259 +* 07: C-SIGN Inverted instruction 260 +* 08: E-STOP Emergency stop 261 +* 09: GEAR-SEL Electronic Gear Switch 1 262 +* 10: GAIN-SEL gain switch 263 +* 11: INH Instruction pulse prohibited input 264 +* 12: VSSEL Vibration control switch input 265 +* 13: INSPD1 Internal speed instruction selection 1 266 +* 14: INSPD2 Internal speed instruction selection 2 267 +* 15: INSPD3 Internal speedinstruction selection 3 268 +* 16: J-SEL inertia ratio switch (not implemented yet) 269 +* 17: MixModesel mixed mode selection 270 +* 20: Internal multi-segment position enable signal 271 +* 21: Internal multi-segment position selection 1 272 +* 22: Internal multi-segment position selection 2 273 +* 23: Internal multi-segment position selection 3 274 +* 24: Internal multi-segment position selection 4 275 +* Others: reserved 308 308 )))|- 309 309 |=(% style="width: 89px;" %)P06-09|(% style="width:135px" %)DI_3 channel logic selection|(% style="width:122px" %)Operation setting|(% style="width:114px" %)((( 310 310 Effective immediately ... ... @@ -311,9 +311,8 @@ 311 311 )))|(% style="width:106px" %)0|(% style="width:84px" %)0 to 1|(% style="width:380px" %)((( 312 312 DI port input logic validity function selection. 313 313 314 -0: Normally open input. Active low level (switch on); 315 - 316 -1: Normally closed input. Active high level (switch off); 282 +* 0: Normally open input. Active low level (switch on); 283 +* 1: Normally closed input. Active high level (switch off); 317 317 )))|- 318 318 |=(% style="width: 89px;" %)P06-10|(% style="width:135px" %)DI_3 input source selection|(% style="width:122px" %)Operation setting|(% style="width:114px" %)((( 319 319 Effective immediately ... ... @@ -320,9 +320,8 @@ 320 320 )))|(% style="width:106px" %)0|(% style="width:84px" %)0 to 1|(% style="width:380px" %)((( 321 321 Select the DI_3 port type to enable 322 322 323 -0: Hardware DI_3 input terminal 324 - 325 -1: virtual VDI_3 input terminal 290 +* 0: Hardware DI_3 input terminal 291 +* 1: virtual VDI_3 input terminal 326 326 )))|- 327 327 |=(% style="width: 89px;" %)P06-11|(% style="width:135px" %)DI_4 channel function selection|(% style="width:122px" %)((( 328 328 Operation setting ... ... @@ -329,53 +329,30 @@ 329 329 )))|(% style="width:114px" %)((( 330 330 again Power-on 331 331 )))|(% style="width:106px" %)4|(% style="width:84px" %)0 to 32|(% style="width:380px" %)((( 332 -0: OFF (not used) 333 - 334 -01: SON Servo enable 335 - 336 -02: A-CLR Fault and Warning Clear 337 - 338 -03: POT Forward drive prohibition 339 - 340 -04: NOT Reverse drive prohibition 341 - 342 -05: ZCLAMP Zero speed 343 - 344 -06: CL Clear deviation counter 345 - 346 -07: C-SIGN Inverted instruction 347 - 348 -08: E-STOP Emergency shutdown 349 - 350 -09: GEAR-SEL Electronic Gear Switch 1 351 - 352 -10: GAIN-SEL gain switch 353 - 354 -11: INH Instruction pulse prohibited input 355 - 356 -12: VSSEL Vibration control switch input 357 - 358 -13: INSPD1 Internal speed instruction selection 1 359 - 360 -14: INSPD2 Internal speed instruction selection 2 361 - 362 -15: INSPD3 Internal speed instruction selection 3 363 - 364 -16: J-SEL inertia ratio switch (not implemented yet) 365 - 366 -17: MixModesel mixed mode selection 367 - 368 -20: Internal multi-segment position enable signal 369 - 370 -21: Internal multi-segment position selection 1 371 - 372 -22: Internal multi-segment position selection 2 373 - 374 -23: Internal multi-segment position selection 3 375 - 376 -24: Internal multi-segment position selection 4 377 - 378 -Others: reserved 298 +* 0: OFF (not used) 299 +* 01: SON Servo enable 300 +* 02: A-CLR Fault and Warning Clear 301 +* 03: POT Forward drive prohibition 302 +* 04: NOT Reverse drive prohibition 303 +* 05: ZCLAMP Zero speed 304 +* 06: CL Clear deviation counter 305 +* 07: C-SIGN Inverted instruction 306 +* 08: E-STOP Emergency shutdown 307 +* 09: GEAR-SEL Electronic Gear Switch 1 308 +* 10: GAIN-SEL gain switch 309 +* 11: INH Instruction pulse prohibited input 310 +* 12: VSSEL Vibration control switch input 311 +* 13: INSPD1 Internal speed instruction selection 1 312 +* 14: INSPD2 Internal speed instruction selection 2 313 +* 15: INSPD3 Internal speed instruction selection 3 314 +* 16: J-SEL inertia ratio switch (not implemented yet) 315 +* 17: MixModesel mixed mode selection 316 +* 20: Internal multi-segment position enable signal 317 +* 21: Internal multi-segment position selection 1 318 +* 22: Internal multi-segment position selection 2 319 +* 23: Internal multi-segment position selection 3 320 +* 24: Internal multi-segment position selection 4 321 +* Others: reserved 379 379 )))|- 380 380 |=(% style="width: 89px;" %)P06-12|(% style="width:135px" %)DI_4 channel logic selection|(% style="width:122px" %)Operation setting|(% style="width:114px" %)((( 381 381 Effective immediately ... ... @@ -382,9 +382,8 @@ 382 382 )))|(% style="width:106px" %)0|(% style="width:84px" %)0 to 1|(% style="width:380px" %)((( 383 383 DI port input logic validity function selection. 384 384 385 -0: Normally open input. Active low level (switch on); 386 - 387 -1: Normally closed input. Active high level (switch off); 328 +* 0: Normally open input. Active low level (switch on); 329 +* 1: Normally closed input. Active high level (switch off); 388 388 )))|- 389 389 |=(% style="width: 89px;" %)P06-13|(% style="width:135px" %)DI_4 input source selection|(% style="width:122px" %)Operation setting|(% style="width:114px" %)((( 390 390 Effective immediately ... ... @@ -391,9 +391,8 @@ 391 391 )))|(% style="width:106px" %)0|(% style="width:84px" %)0 to 1|(% style="width:380px" %)((( 392 392 Select the DI_4 port type to enable 393 393 394 -0: Hardware DI_4 input terminal 395 - 396 -1: virtual VDI_4 input terminal 336 +* 0: Hardware DI_4 input terminal 337 +* 1: virtual VDI_4 input terminal 397 397 )))|- 398 398 399 399 Table 6-8 DI3 and DI4 channel parameters