... ... @@ -311,9 +311,9 @@
311 311  )))|(% style="width:106px" %)0|(% style="width:84px" %)0 to 1|(% style="width:380px" %)(((
312 312  DI port input logic validity function selection.
313 313  
314 -0: Normally open input. Active low level (switch on);
314 +0: Normally open input. Low level valid (switch on);
315 315  
316 -1: Normally closed input. Active high level (switch off);
316 +1: Normally closed input. High level valid (switch off);
317 317  )))|-
318 318  |=(% style="width: 89px;" %)P06-10|(% style="width:135px" %)DI_3 input source selection|(% style="width:122px" %)Operation setting|(% style="width:114px" %)(((
319 319  Effective immediately
... ... @@ -322,7 +322,7 @@
322 322  
323 323  0: Hardware DI_3 input terminal
324 324  
325 -1: virtual VDI_3 input terminal
325 +1: Virtual VDI_3 input terminal
326 326  )))|-
327 327  |=(% style="width: 89px;" %)P06-11|(% style="width:135px" %)DI_4 channel function selection|(% style="width:122px" %)(((
328 328  Operation setting
... ... @@ -375,6 +375,11 @@
375 375  
376 376  24: Internal multi-segment position selection 4
377 377  
378 +25: HOME_START Homing start
379 +26: HOME ORG Homing signal
380 +27: JOGU DI Forward jog
381 +28: JOGD DI Reverse jog
382 +
378 378  Others: reserved
379 379  )))|-
380 380  |=(% style="width: 89px;" %)P06-12|(% style="width:135px" %)DI_4 channel logic selection|(% style="width:122px" %)Operation setting|(% style="width:114px" %)(((
... ... @@ -382,9 +382,9 @@
382 382  )))|(% style="width:106px" %)0|(% style="width:84px" %)0 to 1|(% style="width:380px" %)(((
383 383  DI port input logic validity function selection.
384 384  
385 -0: Normally open input. Active low level (switch on);
390 +0: Normally open input. Low level valid (switch on);
386 386  
387 -1: Normally closed input. Active high level (switch off);
392 +1: Normally closed input. High level valid (switch off);
388 388  )))|-
389 389  |=(% style="width: 89px;" %)P06-13|(% style="width:135px" %)DI_4 input source selection|(% style="width:122px" %)Operation setting|(% style="width:114px" %)(((
390 390  Effective immediately
... ... @@ -393,7 +393,7 @@
393 393  
394 394  0: Hardware DI_4 input terminal
395 395  
396 -1: virtual VDI_4 input terminal
401 +1: Virtual VDI_4 input terminal
397 397  )))|-
398 398  
399 399  Table 6-8 DI3 and DI4 channel parameters