Changes for page 06 Operation
Last modified by Iris on 2025/08/06 18:24
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -1477,7 +1477,7 @@ 1477 1477 |135|P-NEAR (positioning approach)| |146|COM_VDO1(Communication VDO2 output) 1478 1478 |136|V-COIN (consistent speed)| |147|COM_VDO1(communication VDO3 output) 1479 1479 |137|V-NEAR (speed approach)| |148|COM_VDO1(communication VDO4 output) 1480 -|138|T-COIN (torque arrival)| | 1480 +|138|T-COIN (torque arrival)| |149|HOME_ATTAIN (Homing arrived) 1481 1481 1482 1482 When P06-32 is set to a value other than the above table, it is considered to not use DO port function. 1483 1483 ... ... @@ -1492,6 +1492,8 @@ 1492 1492 ② Only in the VD2-0xxSA1H model, the default function code for the DO_1 channel function selection is 130ALM (fault signal)! In the VD2-0xxSA1H model, the function code for the DO_2, DO_3, and DO_4 channels are 143 OZ (Z/A/B pulse output), and these 3 channels correspond to the Z-axis, A-axis, and B-axis of the pulse output respectively! 1493 1493 1494 1494 ③ The function selection code of DO_2, DO_3 and DO_4 channels in the VD2L-0xxSA1P model are 143 OZ (Z pulse output), and these 3 channels correspond to Z axis, pulse axis, and direction axis of the pulse output respectively! 1495 + 1496 +④VD2L does not support function code 149. 1495 1495 ))) 1496 1496 1497 1497 = **Speed control mode** = ... ... @@ -1518,8 +1518,9 @@ 1518 1518 )))|(% style="width:125px" %)((( 1519 1519 Effective immediately 1520 1520 )))|(% style="width:85px" %)0|(% style="width:75px" %)0 to 1|(% style="width:310px" %)((( 1521 -* 0: internal speed instruction 1522 -* 1: AI_1 analog input (not supported by VD2F) 1523 +0: internal speed instruction 1524 + 1525 +1: AI_1 analog input (not supported by **VD2F and VD2L**) 1523 1523 )))|- 1524 1524 1525 1525 Table 6-26 Speed instruction source parameter ... ... @@ -1550,15 +1550,17 @@ 1550 1550 Effective 1551 1551 1552 1552 immediately 1553 -)))|(% colspan="2" %)0|(% colspan="2" %)- 5000 to5000|(% colspan="2" %)(((1556 +)))|(% colspan="2" %)0|(% colspan="2" %)-6000 to 6000|(% colspan="2" %)((( 1554 1554 Internal speed instruction 0 1555 1555 1556 1556 When DI input port: 1557 1557 1558 -* 15-INSPD3: 0 1559 -* 14-INSPD2: 0 1560 -* 13-INSPD1: 0, 1561 +15-INSPD3: 0 1561 1561 1563 +14-INSPD2: 0 1564 + 1565 +13-INSPD1: 0, 1566 + 1562 1562 select this speed instruction to be effective. 1563 1563 )))|(% colspan="2" %)rpm 1564 1564 |=(% colspan="1" %)P01-23|(% colspan="2" %)((( ... ... @@ -1573,15 +1573,17 @@ 1573 1573 Effective 1574 1574 1575 1575 immediately 1576 -)))|(% colspan="2" %)0|(% colspan="2" %)- 5000 to5000|(% colspan="2" %)(((1581 +)))|(% colspan="2" %)0|(% colspan="2" %)-6000 to 6000|(% colspan="2" %)((( 1577 1577 Internal speed instruction 1 1578 1578 1579 1579 When DI input port: 1580 1580 1581 -* 15-INSPD3: 0 1582 -* 14-INSPD2: 0 1583 -* 13-INSPD1: 1, 1586 +15-INSPD3: 0 1584 1584 1588 +14-INSPD2: 0 1589 + 1590 +13-INSPD1: 1, 1591 + 1585 1585 Select this speed instruction to be effective. 1586 1586 )))|(% colspan="2" %)rpm 1587 1587 |=(% colspan="1" %)P01-24|(% colspan="2" %)((( ... ... @@ -1596,15 +1596,17 @@ 1596 1596 Effective 1597 1597 1598 1598 immediately 1599 -)))|(% colspan="2" %)0|(% colspan="2" %)- 5000 to5000|(% colspan="2" %)(((1606 +)))|(% colspan="2" %)0|(% colspan="2" %)-6000 to 6000|(% colspan="2" %)((( 1600 1600 Internal speed instruction 2 1601 1601 1602 1602 When DI input port: 1603 1603 1604 -* 15-INSPD3: 0 1605 -* 14-INSPD2: 1 1606 -* 13-INSPD1: 0, 1611 +15-INSPD3: 0 1607 1607 1613 +14-INSPD2: 1 1614 + 1615 +13-INSPD1: 0, 1616 + 1608 1608 Select this speed instruction to be effective. 1609 1609 )))|(% colspan="2" %)rpm 1610 1610 |=(% colspan="1" %)P01-25|(% colspan="2" %)((( ... ... @@ -1619,15 +1619,17 @@ 1619 1619 Effective 1620 1620 1621 1621 immediately 1622 -)))|(% colspan="2" %)0|(% colspan="2" %)- 5000 to5000|(% colspan="2" %)(((1631 +)))|(% colspan="2" %)0|(% colspan="2" %)-6000 to 6000|(% colspan="2" %)((( 1623 1623 Internal speed instruction 3 1624 1624 1625 1625 When DI input port: 1626 1626 1627 -* 15-INSPD3: 0 1628 -* 14-INSPD2: 1 1629 -* 13-INSPD1: 1, 1636 +15-INSPD3: 0 1630 1630 1638 +14-INSPD2: 1 1639 + 1640 +13-INSPD1: 1, 1641 + 1631 1631 Select this speed instruction to be effective. 1632 1632 )))|(% colspan="2" %)rpm 1633 1633 |=P01-26|(% colspan="2" %)((( ... ... @@ -1642,15 +1642,17 @@ 1642 1642 Effective 1643 1643 1644 1644 immediately 1645 -)))|(% colspan="2" %)0|(% colspan="2" %)- 5000 to5000|(% colspan="2" %)(((1656 +)))|(% colspan="2" %)0|(% colspan="2" %)-6000 to 6000|(% colspan="2" %)((( 1646 1646 Internal speed instruction 4 1647 1647 1648 1648 When DI input port: 1649 1649 1650 -* 15-INSPD3: 1 1651 -* 14-INSPD2: 0 1652 -* 13-INSPD1: 0, 1661 +15-INSPD3: 1 1653 1653 1663 +14-INSPD2: 0 1664 + 1665 +13-INSPD1: 0, 1666 + 1654 1654 Select this speed instruction to be effective. 1655 1655 )))|(% colspan="1" %)rpm 1656 1656 |=P01-27|(% colspan="2" %)((( ... ... @@ -1665,15 +1665,17 @@ 1665 1665 Effective 1666 1666 1667 1667 immediately 1668 -)))|(% colspan="2" %)0|(% colspan="2" %)- 5000 to5000|(% colspan="2" %)(((1681 +)))|(% colspan="2" %)0|(% colspan="2" %)-6000 to 6000|(% colspan="2" %)((( 1669 1669 Internal speed instruction 5 1670 1670 1671 1671 When DI input port: 1672 1672 1673 -* 15-INSPD3: 1 1674 -* 14-INSPD2: 0 1675 -* 13-INSPD1: 1, 1686 +15-INSPD3: 1 1676 1676 1688 +14-INSPD2: 0 1689 + 1690 +13-INSPD1: 1, 1691 + 1677 1677 Select this speed instruction to be effective. 1678 1678 )))|(% colspan="1" %)rpm 1679 1679 |=P01-28|(% colspan="2" %)((( ... ... @@ -1688,15 +1688,17 @@ 1688 1688 Effective 1689 1689 1690 1690 immediately 1691 -)))|(% colspan="2" %)0|(% colspan="2" %)- 5000 to5000|(% colspan="2" %)(((1706 +)))|(% colspan="2" %)0|(% colspan="2" %)-6000 to 6000|(% colspan="2" %)((( 1692 1692 Internal speed instruction 6 1693 1693 1694 1694 When DI input port: 1695 1695 1696 -* 15-INSPD3: 1 1697 -* 14-INSPD2: 1 1698 -* 13-INSPD1: 0, 1711 +15-INSPD3: 1 1699 1699 1713 +14-INSPD2: 1 1714 + 1715 +13-INSPD1: 0, 1716 + 1700 1700 Select this speed instruction to be effective. 1701 1701 )))|(% colspan="1" %)rpm 1702 1702 |=P01-29|(% colspan="2" %)((( ... ... @@ -1711,15 +1711,17 @@ 1711 1711 Effective 1712 1712 1713 1713 immediately 1714 -)))|(% colspan="2" %)0|(% colspan="2" %)- 5000 to5000|(% colspan="2" %)(((1731 +)))|(% colspan="2" %)0|(% colspan="2" %)-6000 to 6000|(% colspan="2" %)((( 1715 1715 Internal speed instruction 7 1716 1716 1717 1717 When DI input port: 1718 1718 1719 -* 15-INSPD3: 1 1720 -* 14-INSPD2: 1 1721 -* 13-INSPD1: 1, 1736 +15-INSPD3: 1 1722 1722 1738 +14-INSPD2: 1 1739 + 1740 +13-INSPD1: 1, 1741 + 1723 1723 Select this speed instruction to be effective. 1724 1724 )))|(% colspan="1" %)rpm 1725 1725 ... ... @@ -1735,12 +1735,13 @@ 1735 1735 The multi-speed segment number is a 3-bit binary number, and the DI terminal logic is level valid. When the input level is valid, the segment selection bit value is 1, otherwise it is 0. The corresponding relationship between INSPD1 to 3 and segment numbers is shown as below. 1736 1736 1737 1737 1738 -|=**INSPD3**|=**INSPD2**|=**INSPD1**|=**Running segment number**|=**Internal speed instruction number** 1739 -|0|0|0|1|0 1740 -|0|0|1|2|1 1741 -|0|1|0|3|2 1742 -|(% colspan="5" %)...... 1743 -|1|1|1|8|7 1757 +(% style="margin-left:auto; margin-right:auto" %) 1758 +|=(% style="text-align: center; vertical-align: middle;" %)**INSPD3**|=(% style="text-align: center; vertical-align: middle;" %)**INSPD2**|=(% style="text-align: center; vertical-align: middle;" %)**INSPD1**|=(% style="text-align: center; vertical-align: middle;" %)**Running segment number**|=(% style="text-align: center; vertical-align: middle;" %)**Internal speed instruction number** 1759 +|(% style="text-align:center; vertical-align:middle" %)0|(% style="text-align:center; vertical-align:middle" %)0|(% style="text-align:center; vertical-align:middle" %)0|(% style="text-align:center; vertical-align:middle" %)1|(% style="text-align:center; vertical-align:middle" %)0 1760 +|(% style="text-align:center; vertical-align:middle" %)0|(% style="text-align:center; vertical-align:middle" %)0|(% style="text-align:center; vertical-align:middle" %)1|(% style="text-align:center; vertical-align:middle" %)2|(% style="text-align:center; vertical-align:middle" %)1 1761 +|(% style="text-align:center; vertical-align:middle" %)0|(% style="text-align:center; vertical-align:middle" %)1|(% style="text-align:center; vertical-align:middle" %)0|(% style="text-align:center; vertical-align:middle" %)3|(% style="text-align:center; vertical-align:middle" %)2 1762 +|(% colspan="5" style="text-align:center; vertical-align:middle" %)...... 1763 +|(% style="text-align:center; vertical-align:middle" %)1|(% style="text-align:center; vertical-align:middle" %)1|(% style="text-align:center; vertical-align:middle" %)1|(% style="text-align:center; vertical-align:middle" %)8|(% style="text-align:center; vertical-align:middle" %)7 1744 1744 1745 1745 Table 6-29 Correspondence between INSPD bits and segment numbers 1746 1746 ... ... @@ -1781,16 +1781,22 @@ 1781 1781 ))) 1782 1782 1783 1783 |=(% scope="row" %)**Function code**|=**Name**|=**Setting method**|=**Effective time**|=**Default value**|=**Range**|=**Definition**|=**Unit** 1784 -|=P05-01☆|AI_1 input bias|Operation setting|Effective immediately|0|-5000 to 5000|Set AI_1 channel analog bias value|mV 1785 -|=P05-02☆|AI_1 input filter time constant|Operation setting|Effective immediately|200|0 to 60000|AI_1 channel input first-order low-pass filtering time constant|0.01ms 1786 -|=P05-03☆|AI_1 dead zone|Operation setting|Effective immediately|20|0 to 1000|Set AI_1 channel quantity dead zone value|mV 1787 -|=P05-04☆|AI_1 zero drift|Operation setting|Effective immediately|0|-500 to 500|Automatic calibration of zero drift inside the drive|mV 1804 +|=P05-01((( 1805 +★ 1806 +)))|AI_1 input bias|Operation setting|Effective immediately|0|-5000 to 5000|Set AI_1 channel analog bias value|mV 1807 +|=P05-02((( 1808 +★ 1809 +)))|AI_1 input filter time constant|Operation setting|Effective immediately|200|0 to 60000|AI_1 channel input first-order low-pass filtering time constant|0.01ms 1810 +|=P05-03((( 1811 +★ 1812 +)))|AI_1 dead zone|Operation setting|Effective immediately|20|0 to 1000|Set AI_1 channel quantity dead zone value|mV 1813 +|=P05-04((( 1814 +★ 1815 +)))|AI_1 zero drift|Operation setting|Effective immediately|0|-500 to 500|Automatic calibration of zero drift inside the drive|mV 1788 1788 1789 -Table 6-30 AI_1 parameters 1790 - 1791 1791 (% class="box infomessage" %) 1792 1792 ((( 1793 -✎**Note: **“ ☆” means VD2F servo drive does not support the function code .1819 +✎**Note: **“★” means VD2F and VD2L servo drive does not support the function code . 1794 1794 ))) 1795 1795 1796 1796 == Acceleration and deceleration time setting ==