Changes for page 06 Operation

Last modified by Iris on 2025/08/08 14:40

From version 88.1
edited by Mora Zhou
on 2025/04/29 09:38
Change comment: There is no comment for this version
To version 99.1
edited by Mora Zhou
on 2025/04/29 11:01
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -1477,7 +1477,7 @@
1477 1477  |135|P-NEAR (positioning approach)| |146|COM_VDO1(Communication VDO2 output)
1478 1478  |136|V-COIN (consistent speed)| |147|COM_VDO1(communication VDO3 output)
1479 1479  |137|V-NEAR (speed approach)| |148|COM_VDO1(communication VDO4 output)
1480 -|138|T-COIN (torque arrival)| | |
1480 +|138|T-COIN (torque arrival)| |149|HOME_ATTAIN (Homing arrived)
1481 1481  
1482 1482  When P06-32 is set to a value other than the above table, it is considered to not use DO port function.
1483 1483  
... ... @@ -1492,6 +1492,8 @@
1492 1492  ② Only in the VD2-0xxSA1H model, the default function code for the DO_1 channel function selection is 130ALM (fault signal)! In the VD2-0xxSA1H model, the function code for the DO_2, DO_3, and DO_4 channels are 143 OZ (Z/A/B pulse output), and these 3 channels correspond to the Z-axis, A-axis, and B-axis of the pulse output respectively!
1493 1493  
1494 1494  ③ The function selection code of DO_2, DO_3 and DO_4 channels in the VD2L-0xxSA1P model are 143 OZ (Z pulse output), and these 3 channels correspond to Z axis, pulse axis, and direction axis of the pulse output respectively!
1495 +
1496 +④VD2L does not support function code 149.
1495 1495  )))
1496 1496  
1497 1497  = **Speed control mode** =
... ... @@ -1518,8 +1518,9 @@
1518 1518  )))|(% style="width:125px" %)(((
1519 1519  Effective immediately
1520 1520  )))|(% style="width:85px" %)0|(% style="width:75px" %)0 to 1|(% style="width:310px" %)(((
1521 -* 0: internal speed instruction
1522 -* 1: AI_1 analog input (not supported by VD2F)
1523 +0: internal speed instruction
1524 +
1525 +1: AI_1 analog input (not supported by **VD2F and VD2L**)
1523 1523  )))|-
1524 1524  
1525 1525  Table 6-26 Speed instruction source parameter
... ... @@ -1550,15 +1550,17 @@
1550 1550  Effective
1551 1551  
1552 1552  immediately
1553 -)))|(% colspan="2" %)0|(% colspan="2" %)-5000 to 5000|(% colspan="2" %)(((
1556 +)))|(% colspan="2" %)0|(% colspan="2" %)-6000 to 6000|(% colspan="2" %)(((
1554 1554  Internal speed instruction 0
1555 1555  
1556 1556  When DI input port:
1557 1557  
1558 -* 15-INSPD3: 0
1559 -* 14-INSPD2: 0
1560 -* 13-INSPD1: 0,
1561 +15-INSPD3: 0
1561 1561  
1563 +14-INSPD2: 0
1564 +
1565 +13-INSPD1: 0,
1566 +
1562 1562  select this speed instruction to be effective.
1563 1563  )))|(% colspan="2" %)rpm
1564 1564  |=(% colspan="1" %)P01-23|(% colspan="2" %)(((
... ... @@ -1573,15 +1573,17 @@
1573 1573  Effective
1574 1574  
1575 1575  immediately
1576 -)))|(% colspan="2" %)0|(% colspan="2" %)-5000 to 5000|(% colspan="2" %)(((
1581 +)))|(% colspan="2" %)0|(% colspan="2" %)-6000 to 6000|(% colspan="2" %)(((
1577 1577  Internal speed instruction 1
1578 1578  
1579 1579  When DI input port:
1580 1580  
1581 -* 15-INSPD3: 0
1582 -* 14-INSPD2: 0
1583 -* 13-INSPD1: 1,
1586 +15-INSPD3: 0
1584 1584  
1588 +14-INSPD2: 0
1589 +
1590 +13-INSPD1: 1,
1591 +
1585 1585  Select this speed instruction to be effective.
1586 1586  )))|(% colspan="2" %)rpm
1587 1587  |=(% colspan="1" %)P01-24|(% colspan="2" %)(((
... ... @@ -1596,15 +1596,17 @@
1596 1596  Effective
1597 1597  
1598 1598  immediately
1599 -)))|(% colspan="2" %)0|(% colspan="2" %)-5000 to 5000|(% colspan="2" %)(((
1606 +)))|(% colspan="2" %)0|(% colspan="2" %)-6000 to 6000|(% colspan="2" %)(((
1600 1600  Internal speed instruction 2
1601 1601  
1602 1602  When DI input port:
1603 1603  
1604 -* 15-INSPD3: 0
1605 -* 14-INSPD2: 1
1606 -* 13-INSPD1: 0,
1611 +15-INSPD3: 0
1607 1607  
1613 +14-INSPD2: 1
1614 +
1615 +13-INSPD1: 0,
1616 +
1608 1608  Select this speed instruction to be effective.
1609 1609  )))|(% colspan="2" %)rpm
1610 1610  |=(% colspan="1" %)P01-25|(% colspan="2" %)(((
... ... @@ -1619,15 +1619,17 @@
1619 1619  Effective
1620 1620  
1621 1621  immediately
1622 -)))|(% colspan="2" %)0|(% colspan="2" %)-5000 to 5000|(% colspan="2" %)(((
1631 +)))|(% colspan="2" %)0|(% colspan="2" %)-6000 to 6000|(% colspan="2" %)(((
1623 1623  Internal speed instruction 3
1624 1624  
1625 1625  When DI input port:
1626 1626  
1627 -* 15-INSPD3: 0
1628 -* 14-INSPD2: 1
1629 -* 13-INSPD1: 1,
1636 +15-INSPD3: 0
1630 1630  
1638 +14-INSPD2: 1
1639 +
1640 +13-INSPD1: 1,
1641 +
1631 1631  Select this speed instruction to be effective.
1632 1632  )))|(% colspan="2" %)rpm
1633 1633  |=P01-26|(% colspan="2" %)(((
... ... @@ -1642,15 +1642,17 @@
1642 1642  Effective
1643 1643  
1644 1644  immediately
1645 -)))|(% colspan="2" %)0|(% colspan="2" %)-5000 to 5000|(% colspan="2" %)(((
1656 +)))|(% colspan="2" %)0|(% colspan="2" %)-6000 to 6000|(% colspan="2" %)(((
1646 1646  Internal speed instruction 4
1647 1647  
1648 1648  When DI input port:
1649 1649  
1650 -* 15-INSPD3: 1
1651 -* 14-INSPD2: 0
1652 -* 13-INSPD1: 0,
1661 +15-INSPD3: 1
1653 1653  
1663 +14-INSPD2: 0
1664 +
1665 +13-INSPD1: 0,
1666 +
1654 1654  Select this speed instruction to be effective.
1655 1655  )))|(% colspan="1" %)rpm
1656 1656  |=P01-27|(% colspan="2" %)(((
... ... @@ -1665,15 +1665,17 @@
1665 1665  Effective
1666 1666  
1667 1667  immediately
1668 -)))|(% colspan="2" %)0|(% colspan="2" %)-5000 to 5000|(% colspan="2" %)(((
1681 +)))|(% colspan="2" %)0|(% colspan="2" %)-6000 to 6000|(% colspan="2" %)(((
1669 1669  Internal speed instruction 5
1670 1670  
1671 1671  When DI input port:
1672 1672  
1673 -* 15-INSPD3: 1
1674 -* 14-INSPD2: 0
1675 -* 13-INSPD1: 1,
1686 +15-INSPD3: 1
1676 1676  
1688 +14-INSPD2: 0
1689 +
1690 +13-INSPD1: 1,
1691 +
1677 1677  Select this speed instruction to be effective.
1678 1678  )))|(% colspan="1" %)rpm
1679 1679  |=P01-28|(% colspan="2" %)(((
... ... @@ -1688,15 +1688,17 @@
1688 1688  Effective
1689 1689  
1690 1690  immediately
1691 -)))|(% colspan="2" %)0|(% colspan="2" %)-5000 to 5000|(% colspan="2" %)(((
1706 +)))|(% colspan="2" %)0|(% colspan="2" %)-6000 to 6000|(% colspan="2" %)(((
1692 1692  Internal speed instruction 6
1693 1693  
1694 1694  When DI input port:
1695 1695  
1696 -* 15-INSPD3: 1
1697 -* 14-INSPD2: 1
1698 -* 13-INSPD1: 0,
1711 +15-INSPD3: 1
1699 1699  
1713 +14-INSPD2: 1
1714 +
1715 +13-INSPD1: 0,
1716 +
1700 1700  Select this speed instruction to be effective.
1701 1701  )))|(% colspan="1" %)rpm
1702 1702  |=P01-29|(% colspan="2" %)(((
... ... @@ -1711,15 +1711,17 @@
1711 1711  Effective
1712 1712  
1713 1713  immediately
1714 -)))|(% colspan="2" %)0|(% colspan="2" %)-5000 to 5000|(% colspan="2" %)(((
1731 +)))|(% colspan="2" %)0|(% colspan="2" %)-6000 to 6000|(% colspan="2" %)(((
1715 1715  Internal speed instruction 7
1716 1716  
1717 1717  When DI input port:
1718 1718  
1719 -* 15-INSPD3: 1
1720 -* 14-INSPD2: 1
1721 -* 13-INSPD1: 1,
1736 +15-INSPD3: 1
1722 1722  
1738 +14-INSPD2: 1
1739 +
1740 +13-INSPD1: 1,
1741 +
1723 1723  Select this speed instruction to be effective.
1724 1724  )))|(% colspan="1" %)rpm
1725 1725  
... ... @@ -1735,12 +1735,13 @@
1735 1735  The multi-speed segment number is a 3-bit binary number, and the DI terminal logic is level valid. When the input level is valid, the segment selection bit value is 1, otherwise it is 0. The corresponding relationship between INSPD1 to 3 and segment numbers is shown as below.
1736 1736  
1737 1737  
1738 -|=**INSPD3**|=**INSPD2**|=**INSPD1**|=**Running segment number**|=**Internal speed instruction number**
1739 -|0|0|0|1|0
1740 -|0|0|1|2|1
1741 -|0|1|0|3|2
1742 -|(% colspan="5" %)......
1743 -|1|1|1|8|7
1757 +(% style="margin-left:auto; margin-right:auto" %)
1758 +|=(% style="text-align: center; vertical-align: middle;" %)**INSPD3**|=(% style="text-align: center; vertical-align: middle;" %)**INSPD2**|=(% style="text-align: center; vertical-align: middle;" %)**INSPD1**|=(% style="text-align: center; vertical-align: middle;" %)**Running segment number**|=(% style="text-align: center; vertical-align: middle;" %)**Internal speed instruction number**
1759 +|(% style="text-align:center; vertical-align:middle" %)0|(% style="text-align:center; vertical-align:middle" %)0|(% style="text-align:center; vertical-align:middle" %)0|(% style="text-align:center; vertical-align:middle" %)1|(% style="text-align:center; vertical-align:middle" %)0
1760 +|(% style="text-align:center; vertical-align:middle" %)0|(% style="text-align:center; vertical-align:middle" %)0|(% style="text-align:center; vertical-align:middle" %)1|(% style="text-align:center; vertical-align:middle" %)2|(% style="text-align:center; vertical-align:middle" %)1
1761 +|(% style="text-align:center; vertical-align:middle" %)0|(% style="text-align:center; vertical-align:middle" %)1|(% style="text-align:center; vertical-align:middle" %)0|(% style="text-align:center; vertical-align:middle" %)3|(% style="text-align:center; vertical-align:middle" %)2
1762 +|(% colspan="5" style="text-align:center; vertical-align:middle" %)......
1763 +|(% style="text-align:center; vertical-align:middle" %)1|(% style="text-align:center; vertical-align:middle" %)1|(% style="text-align:center; vertical-align:middle" %)1|(% style="text-align:center; vertical-align:middle" %)8|(% style="text-align:center; vertical-align:middle" %)7
1744 1744  
1745 1745  Table 6-29 Correspondence between INSPD bits and segment numbers
1746 1746  
... ... @@ -1781,16 +1781,22 @@
1781 1781  )))
1782 1782  
1783 1783  |=(% scope="row" %)**Function code**|=**Name**|=**Setting method**|=**Effective time**|=**Default value**|=**Range**|=**Definition**|=**Unit**
1784 -|=P05-01☆|AI_1 input bias|Operation setting|Effective immediately|0|-5000 to 5000|Set AI_1 channel analog bias value|mV
1785 -|=P05-02☆|AI_1 input filter time constant|Operation setting|Effective immediately|200|0 to 60000|AI_1 channel input first-order low-pass filtering time constant|0.01ms
1786 -|=P05-03☆|AI_1 dead zone|Operation setting|Effective immediately|20|0 to 1000|Set AI_1 channel quantity dead zone value|mV
1787 -|=P05-04☆|AI_1 zero drift|Operation setting|Effective immediately|0|-500 to 500|Automatic calibration of zero drift inside the drive|mV
1804 +|=P05-01(((
1805 +★
1806 +)))|AI_1 input bias|Operation setting|Effective immediately|0|-5000 to 5000|Set AI_1 channel analog bias value|mV
1807 +|=P05-02(((
1808 +★
1809 +)))|AI_1 input filter time constant|Operation setting|Effective immediately|200|0 to 60000|AI_1 channel input first-order low-pass filtering time constant|0.01ms
1810 +|=P05-03(((
1811 +★
1812 +)))|AI_1 dead zone|Operation setting|Effective immediately|20|0 to 1000|Set AI_1 channel quantity dead zone value|mV
1813 +|=P05-04(((
1814 +★
1815 +)))|AI_1 zero drift|Operation setting|Effective immediately|0|-500 to 500|Automatic calibration of zero drift inside the drive|mV
1788 1788  
1789 -Table 6-30 AI_1 parameters
1790 -
1791 1791  (% class="box infomessage" %)
1792 1792  (((
1793 -✎**Note: **“” means VD2F servo drive does not support the function code .
1819 +✎**Note: **“” means VD2F and VD2L servo drive does not support the function code .
1794 1794  )))
1795 1795  
1796 1796  == Acceleration and deceleration time setting ==
... ... @@ -1884,10 +1884,13 @@
1884 1884  )))|0|0 to 3|(((
1885 1885  Set the zero-speed clamp function. In speed mode:
1886 1886  
1887 -* 0: Force the speed to 0;
1888 -* 1: Force the speed to 0, and keep the position locked when the actual speed is less than P01-22
1889 -* 2: When speed instruction is less than P01-22, force the speed to 0 and keep the position locked
1890 -* 3: Invalid, ignore zero-speed clamp input
1913 +0: Force the speed to 0;
1914 +
1915 +1: Force the speed to 0, and keep the position locked when the actual speed is less than P01-22
1916 +
1917 +2: When speed instruction is less than P01-22, force the speed to 0 and keep the position locked
1918 +
1919 +3: Invalid, ignore zero-speed clamp input
1891 1891  )))|-
1892 1892  |=P01-22|(((
1893 1893  Zero-speed clamp speed threshold
... ... @@ -1895,7 +1895,7 @@
1895 1895  Operation setting
1896 1896  )))|(((
1897 1897  Effective immediately
1898 -)))|20|0 to 1000|Set the speed threshold of zero-speed clamp function|rpm
1927 +)))|20|0 to 6000|Set the speed threshold of zero-speed clamp function|rpm
1899 1899  
1900 1900  Table 6-33 Zero-speed clamp related parameters
1901 1901  
... ... @@ -1940,7 +1940,7 @@
1940 1940  
1941 1941  |=(% scope="row" %)**DO function code**|=(% style="width: 247px;" %)**Function name**|=(% style="width: 695px;" %)**Function**
1942 1942  |=132|(% style="width:247px" %)(((
1943 -T-COIN rotation detection
1972 +TGON rotation detection
1944 1944  )))|(% style="width:695px" %)(((
1945 1945  Valid: when the absolute value of motor speed after filtering is greater than or equal to the set value of function code P05-16
1946 1946  
... ... @@ -2008,7 +2008,7 @@
2008 2008  
2009 2009  |=(% scope="row" %)**DO Function code**|=(% style="width: 262px;" %)**Function name**|=(% style="width: 684px;" %)**Function**
2010 2010  |=136|(% style="width:262px" %)(((
2011 -U-COIN consistent speed
2040 +V-COIN consistent speed
2012 2012  )))|(% style="width:684px" %)The output signal indicates that the absolute deviation of the actual speed of servo motor and the speed instruction meets the P05-17 set value
2013 2013  
2014 2014  Table 6-39 DO speed consistent function code
... ... @@ -2192,8 +2192,9 @@
2192 2192  )))|(((
2193 2193  Effective immediately
2194 2194  )))|0|0 to 1|(((
2195 -* 0: internal value
2196 -* 1: AI_1 analog input (not supported by VD2F and VD2L)
2224 +0: internal value
2225 +
2226 +1: AI_1 analog input (not supported by VD2F and VD2L)
2197 2197  )))|-
2198 2198  
2199 2199  * Torque limit source is internal torque instruction (P01-14=0)
... ... @@ -2270,7 +2270,7 @@
2270 2270  Operation setting
2271 2271  )))|(((
2272 2272  Effective immediately
2273 -)))|3000|0 to 5000|(((
2303 +)))|3000|0 to 6000|(((
2274 2274  Forward torque
2275 2275  
2276 2276  limit in torque mode
... ... @@ -2283,7 +2283,7 @@
2283 2283  Operation setting
2284 2284  )))|(((
2285 2285  Effective immediately
2286 -)))|3000|0 to 5000|(((
2316 +)))|3000|0 to 6000|(((
2287 2287  Reverse torque
2288 2288  
2289 2289  limit in torque mode
... ... @@ -2368,13 +2368,18 @@
2368 2368  )))|(((
2369 2369  Shutdown setting
2370 2370  )))|1|(% style="width:90px" %)1 to 6|(% style="width:273px" %)(((
2371 -* 1: Position control
2372 -* 2: Speed control
2373 -* 3: Torque control
2374 -* 4: Position/speed mixed control
2375 -* 5: Position/torque mixed control
2376 -* 6: Speed/torque mixed control
2401 +1: Position control
2377 2377  
2403 +2: Speed control
2404 +
2405 +3: Torque control
2406 +
2407 +4: Position/speed mixed control
2408 +
2409 +5: Position/torque mixed control
2410 +
2411 +6: Speed/torque mixed control
2412 +
2378 2378  **VD2L drive P0-01 setting range: 1-3, not support mixed mode**
2379 2379  )))|-
2380 2380  
... ... @@ -2516,8 +2516,9 @@
2516 2516  **time**
2517 2517  )))|=**Default value**|=**Range**|=**Definition**|=**Unit**
2518 2518  |=P00-30|Shield multi-turn absolute encoder battery fault|Operation setting|Power on again|0|0 to 1|(((
2519 -* 0:Detect multi-turn absolute encoder battery under voltage, and battery low voltage fault
2520 -* 1: (Not recommended) Shield multi-turn absolute motor battery failure alarm. Multi-turn absolute application may cause mechanical fault, only multi-turn absolute encoder motors is used as single-turn absolute
2554 +0:Detect multi-turn absolute encoder battery under voltage, and battery low voltage fault
2555 +
2556 +1: (Not recommended) Shield multi-turn absolute motor battery failure alarm. Multi-turn absolute application may cause mechanical fault, only multi-turn absolute encoder motors is used as single-turn absolute
2521 2521  )))|-
2522 2522  
2523 2523  This function is permitted when a multi-turn absolute encoder motor is used as a single-turn absolute and when it is confirmed that no mechanical failure will occur.
... ... @@ -2662,8 +2662,9 @@
2662 2662  
2663 2663  VDI_1 input level:
2664 2664  
2665 -* 0: low level
2666 -* 1: high level
2701 +0: Low level
2702 +
2703 +1: High level
2667 2667  )))|-
2668 2668  |=P13-2|Virtual VDI_2 input value|Operation setting|Effective immediately|0|0 to 1|(((
2669 2669  When P06-07 is set to 1, DI_2 channel logic is control by this function code.
... ... @@ -2670,8 +2670,9 @@
2670 2670  
2671 2671  VDI_2 input level:
2672 2672  
2673 -* 0: low level
2674 -* 1: high level
2710 +0: Low level
2711 +
2712 +1: High level
2675 2675  )))|-
2676 2676  |=P13-3|Virtual VDI_3 input value|Operation setting|Effective immediately|0|0 to 1|(((
2677 2677  When P06-10 is set to 1, DI_3 channel logic is control by this function code.
... ... @@ -2678,8 +2678,9 @@
2678 2678  
2679 2679  VDI_3 input level:
2680 2680  
2681 -* 0: low level
2682 -* 1: high level
2719 +0: Low level
2720 +
2721 +1: High level
2683 2683  )))|-
2684 2684  |=P13-4|Virtual VDI_4 input value|Operation setting|Effective immediately|0|0 to 1|(((
2685 2685  When P06-13 is set to 1, DI_4 channel logic is control by this function code.
... ... @@ -2686,40 +2686,53 @@
2686 2686  
2687 2687  VDI_4 input level:
2688 2688  
2689 -* 0: low level
2690 -* 1: high level
2728 +0: Low level
2729 +
2730 +1: High level
2691 2691  )))|-
2692 -|=P13-05☆|Virtual VDI_5 input value|Operation setting|Effective immediately|0|0 to 1|(((
2732 +|=P13-05(((
2733 +★
2734 +)))|Virtual VDI_5 input value|Operation setting|Effective immediately|0|0 to 1|(((
2693 2693  When P06-16 is set to 1, DI_5 channel logic is control by this function code.
2694 2694  
2695 2695  VDI_5 input level:
2696 2696  
2697 -* 0: low level
2698 -* 1: high level
2739 +0: Low level
2740 +
2741 +1: High level
2699 2699  )))|-
2700 -|=P13-06☆|Virtual VDI_6 input value|Operation setting|Effective immediately|0|0 to 1|(((
2743 +|=P13-06(((
2744 +★
2745 +)))|Virtual VDI_6 input value|Operation setting|Effective immediately|0|0 to 1|(((
2701 2701  When P06-19 is set to 1, DI_6 channel logic is control by this function code.
2702 2702  
2703 2703  VDI_6 input level:
2704 2704  
2705 -* 0: low level
2706 -* 1: high level
2750 +0: Low level
2751 +
2752 +1: High level
2707 2707  )))|-
2708 -|=P13-07☆|Virtual VDI_7 input value|Operation setting|Effective immediately|0|0 to 1|(((
2754 +|=P13-07(((
2755 +★
2756 +)))|Virtual VDI_7 input value|Operation setting|Effective immediately|0|0 to 1|(((
2709 2709  When P06-22 is set to 1, DI_7 channel logic is control by this function code.
2710 2710  
2711 2711  VDI_7 input level:
2712 2712  
2713 -* 0: low level
2714 -* 1: high level
2761 +0: Low level
2762 +
2763 +1: High level
2715 2715  )))|-
2716 -|=P13-08☆|Virtual VDI_8 input value|Operation setting|Effective immediately|0|0 to 1|(((
2765 +|=P13-08(((
2766 +★
2767 +)))|Virtual VDI_8 input value|Operation setting|Effective immediately|0|0 to 1|(((
2717 2717  When P06-25 is set to 1, DI_8 channel logic is control by this function code.
2718 2718  
2719 2719  VDI_8 input level:
2720 2720  
2721 -* 0: low level
2722 -* 1: high level
2772 +0: Low level
2773 +
2774 +1: High level
2723 2723  )))|-
2724 2724  
2725 2725  Table 6-57 Virtual VDI parameters
... ... @@ -2726,7 +2726,7 @@
2726 2726  
2727 2727  (% class="box infomessage" %)
2728 2728  (((
2729 -✎**Note: **“” means VD2F servo drive does not support the function code .
2781 +✎**Note: **“” means VD2F and VD2L servo drive does not support the function code .
2730 2730  )))
2731 2731  
2732 2732  == Port filtering time ==
... ... @@ -2760,26 +2760,30 @@
2760 2760  |=P13-11|Communication VDO_1 output value|Operation setting|Effective immediately|0|0 to 1|(((
2761 2761  VDO_1 output level:
2762 2762  
2763 -* 0: low level
2764 -* 1: high level
2815 +0: Low level
2816 +
2817 +1: High level
2765 2765  )))|-
2766 2766  |=P13-12|Communication VDO_2 output value|Operation setting|Effective immediately|0|0 to 1|(((
2767 2767  VDO_2 output level:
2768 2768  
2769 -* 0: low level
2770 -* 1: high level
2822 +0: Low level
2823 +
2824 +1: High level
2771 2771  )))|-
2772 2772  |=P13-13|Communication VDO_3 output value|Operation setting|Effective immediately|0|0 to 1|(((
2773 2773  VDO_3 output level:
2774 2774  
2775 -* 0: low level
2776 -* 1: high level
2829 +0: Low level
2830 +
2831 +1: High level
2777 2777  )))|-
2778 2778  |=P13-14|Communication VDO_4 output value|Operation setting|Effective immediately|0|0 to 1|(((
2779 2779  VDO_4 output level:
2780 2780  
2781 -* 0: low level
2782 -* 1: high level
2836 +0: Low level
2837 +
2838 +1: High level
2783 2783  )))|-
2784 2784  
2785 2785  Table 6-59 Communication control DO function parameters
... ... @@ -2822,3 +2822,916 @@
2822 2822  (((
2823 2823  ✎**Note:** It is advised to configure function codes for DO terminals in sequence to avoid errors. Please use the shielded overload protection fault detection function with caution, otherwise it will cause burn out the motor.
2824 2824  )))
2881 +
2882 +
2883 +== Homing mode ==
2884 +
2885 +The homing mode is used to find the mechanical origin and locate the positional relationship between the mechanical origin and the mechanical zero.
2886 +
2887 +Mechanical homing: A mechanically fixed position may correspond to a certain defined homing switch, or may correspond to the motor Z signal.
2888 +
2889 +Mechanical zero point: Mechanically absolute 0 position.
2890 +
2891 +After the homing, the stop position of the motor is the mechanical homing. By setting P10-08, the relationship between the mechanical homing and the mechanical zero can be set:
2892 +
2893 +Mechanical homing = Mechanical zero +P10-08 (homing offset)
2894 +
2895 +When P10-08=0, the mechanical homing coincides with the mechanical zero.
2896 +
2897 +
2898 +=== Control block diagram ===
2899 +
2900 +[[image:file:///C:\Users\Administrator\AppData\Local\Temp\ksohtml22584\wps1.png]]Figure 6-53 Homing mode control block diagram
2901 +
2902 +
2903 +
2904 +=== Homing mode related function codes ===
2905 +
2906 +|Function code|Name|(((
2907 +Setting
2908 +
2909 +method
2910 +)))|(((
2911 +Effective
2912 +
2913 +time
2914 +)))|Default|Range|Definition|Unit
2915 +|P01-39.|Homing start mode|(((
2916 +Stop
2917 +
2918 +settings
2919 +)))|(((
2920 +Immediately
2921 +
2922 +effective
2923 +)))|0|0 to 2|(((
2924 +0: Close
2925 +
2926 +1: The servo is powered ON and started after the first ON
2927 +
2928 +2: DI enable
2929 +)))|-
2930 +
2931 +
2932 +|Function code|Name|(((
2933 +Setting
2934 +
2935 +method
2936 +)))|(((
2937 +Effective
2938 +
2939 +time
2940 +)))|Default|Range|Definition|Unit
2941 +|P01-40|Homing mode|(((
2942 +Stop
2943 +
2944 +settings
2945 +)))|(((
2946 +Immediately
2947 +
2948 +effective
2949 +)))|0|0 to 35|(((
2950 +0 ~~ 35 Homing mode;
2951 +
2952 +✎Note: VD2 currently does not support 15, 16, 31, 32 modes
2953 +)))|-
2954 +
2955 +|Function code|Name|(((
2956 +Setting
2957 +
2958 +method
2959 +)))|(((
2960 +Effective
2961 +
2962 +time
2963 +)))|Default|Range|Definition|Unit
2964 +|P01-41|High-speed search deceleration point signal velocity|(((
2965 +Running
2966 +
2967 +settings
2968 +)))|(((
2969 +Immediately
2970 +
2971 +effective
2972 +)))|300|1 to 3000|High-speed search deceleration point signal velocity in homing mode|rpm
2973 +
2974 +|Function code|Name|(((
2975 +Setting
2976 +
2977 +method
2978 +)))|(((
2979 +Effective
2980 +
2981 +time
2982 +)))|Default|Range|Definition|Unit
2983 +|P01-42〇|Low speed search homing signal speed|(((
2984 +Running
2985 +
2986 +settings
2987 +)))|(((
2988 +Immediately
2989 +
2990 +effective
2991 +)))|60|1 to 300|Low-speed search origin signal velocity in homing mode|rpm
2992 +
2993 +|Function code|Name|(((
2994 +Setting
2995 +
2996 +method
2997 +)))|(((
2998 +Effective
2999 +
3000 +time
3001 +)))|Default|Range|Definition|Unit
3002 +|P01-43〇|Homing acceleration and deceleration|(((
3003 +Running
3004 +
3005 +settings
3006 +)))|(((
3007 +Immediately
3008 +
3009 +effective
3010 +)))|50|1to1000|(((
3011 +Acceleration and deceleration in homing mode
3012 +
3013 +Time for speed acceleration from 0 to 1000rpm
3014 +)))|ms
3015 +
3016 +|Function code|Name|(((
3017 +Setting
3018 +
3019 +method
3020 +)))|(((
3021 +Effective
3022 +
3023 +time
3024 +)))|Default|Range|Definition|Unit
3025 +|P01-44〇|Homing timeout limited time|(((
3026 +Running
3027 +
3028 +settings
3029 +)))|(((
3030 +Immediately
3031 +
3032 +effective
3033 +)))|65535|100 to 65535|Homing timeout limited time|ms
3034 +
3035 +|Function code|Name|(((
3036 +Setting
3037 +
3038 +method
3039 +)))|(((
3040 +Effective
3041 +
3042 +time
3043 +)))|Default|Range|Definition|Unit
3044 +|P10-08〇|Multi-turn absolute encoder homing offset compensation|(((
3045 +Running
3046 +
3047 +settings
3048 +)))|(((
3049 +Immediately
3050 +
3051 +effective
3052 +)))|0|(((
3053 +-2147483647~~
3054 +
3055 +2147483646
3056 +)))|(((
3057 +P10-08 multi-turn absolute encoder homing offset compensation is used in conjunction with U0-56 multi-turn absolute encoder current position.
3058 +
3059 +When P10-6 is set to 1, the value of U0-56 is updated to P10-8.
3060 +)))|-
3061 +
3062 +== Introduction to homing mode ==
3063 +
3064 +In the following figure, "H" represents P01-41 (high-speed search deceleration point signal speed), and "L" represents P01-42 (low-speed search homing signal speed).
3065 +
3066 +
3067 +(1) P01-40 =1
3068 +
3069 +Mechanical homing: Motor Z signal
3070 +
3071 +Deceleration point: Reverse limit switch (NOT)
3072 +
3073 +① The deceleration point signal is invalid when starting homing
3074 +
3075 +[[image:file:///C:\Users\Administrator\AppData\Local\Temp\ksohtml22584\wps2.png]]
3076 +
3077 +When it starts to homing, NOT=0, it starts to homing at a high speed in the reverse direction. After encountering the rising edge of NOT, it decelerates and reverses the direction, runs at a low speed in the forward direction, and stops at the first Z signal after encountering the falling edge of NOT.
3078 +
3079 +
3080 +② The deceleration point signal is valid when starting homing
3081 +
3082 +[[image:file:///C:\Users\Administrator\AppData\Local\Temp\ksohtml22584\wps3.png]]
3083 +
3084 +When starting to homing, NOT=1, it starts to homing at a direct forward low speed, and stops at the first Z signal after encountering the falling edge of NOT.
3085 +
3086 +
3087 +
3088 +
3089 +
3090 +
3091 +(2) P01-40=2
3092 +
3093 +Mechanical homing: Motor Z signal
3094 +
3095 +Deceleration point: Positive Limit Switch (POT)
3096 +
3097 +① The deceleration point signal is invalid when starting homing
3098 +
3099 +[[image:file:///C:\Users\Administrator\AppData\Local\Temp\ksohtml22584\wps4.png]]
3100 +
3101 +When it starts to homing, POT = 0, and it starts to homing at a forward high speed. After encountering the rising edge of POT, it decelerates and reverses, runs at a reverse low speed, and stops at the first Z signal after encountering the falling edge of POT.
3102 +
3103 +
3104 +② The deceleration point signal is valid when starting homing
3105 +
3106 +[[image:file:///C:\Users\Administrator\AppData\Local\Temp\ksohtml22584\wps5.png]]
3107 +
3108 +POT=1 when start homing, run at low speed directly in the reverse direction, and stops at the first Z signal after the falling edge of POT.
3109 +
3110 +
3111 +
3112 +
3113 +
3114 +
3115 +
3116 +
3117 +
3118 +
3119 +
3120 +
3121 +
3122 +(3) P01-40=3
3123 +
3124 +Mechanical homing: Motor Z signal
3125 +
3126 +Deceleration point: Home switch (HW)
3127 +
3128 +① The deceleration point signal is invalid when starting homing
3129 +
3130 +[[image:file:///C:\Users\Administrator\AppData\Local\Temp\ksohtml22584\wps6.png]]
3131 +
3132 +When it starts to homing, HW=0. It starts to homing at a forward high speed. After encountering the rising edge of HW, it decelerates and reverses the direction. It runs at a reverse low speed. After encountering the falling edge of HW, it continues to run, and then stops when encountering the first Z signal.
3133 +
3134 +
3135 +② The deceleration point signal is valid when starting homing
3136 +
3137 +[[image:file:///C:\Users\Administrator\AppData\Local\Temp\ksohtml22584\wps7.png]]
3138 +
3139 +When starting homing, HW=1, start homing at low speed in reverse directly, and stop at the first Z signal after encountering the falling edge of HW;
3140 +
3141 +
3142 +
3143 +
3144 +
3145 +
3146 +
3147 +
3148 +
3149 +
3150 +
3151 +
3152 +
3153 +(4) P01-40=4
3154 +
3155 +Mechanical homing: Motor Z signal
3156 +
3157 +Deceleration point: Home switch (HW)
3158 +
3159 +① The deceleration point signal is invalid when starting homing
3160 +
3161 +[[image:file:///C:\Users\Administrator\AppData\Local\Temp\ksohtml22584\wps8.png]]
3162 +
3163 +HW=0 when starting to homing, directly start to homing at low speed, and stop at the first Z signal after encountering the rising edge of HW;
3164 +
3165 +
3166 +② The deceleration point signal is valid when starting homing
3167 +
3168 +[[image:file:///C:\Users\Administrator\AppData\Local\Temp\ksohtml22584\wps9.jpg]]
3169 +
3170 +
3171 +When starting to homing, HW = 1, start to homing at a high speed in the reverse direction. After encountering the falling edge of HW, decelerate and reverse, run at a low speed in the forward direction, and stop at the first Z signal after encountering the rising edge of HW.
3172 +
3173 +
3174 +
3175 +
3176 +
3177 +(5) P01-40=5
3178 +
3179 +Mechanical homing: Motor Z signal
3180 +
3181 +Deceleration point: Home switch (HW)
3182 +
3183 +① The deceleration point signal is invalid when starting homing
3184 +
3185 +[[image:file:///C:\Users\Administrator\AppData\Local\Temp\ksohtml22584\wps10.png]]
3186 +
3187 +When it starts to homing, HW = 0, and it starts to homing at a reverse high speed. After encountering the rising edge of HW, it decelerates and reverses the direction, runs at a forward low speed, and stops at the first Z signal after encountering the falling edge of HW.
3188 +
3189 +
3190 +② The deceleration point signal is valid when starting homing
3191 +
3192 +[[image:file:///C:\Users\Administrator\AppData\Local\Temp\ksohtml22584\wps11.png]]
3193 +
3194 +When starting homing, HW=1, it will start homing directly at low speed, and the first Z signal after encountering the falling edge of HW will stop;
3195 +
3196 +
3197 +
3198 +
3199 +
3200 +(6) P01-40=6
3201 +
3202 +Mechanical homing: Motor Z signal
3203 +
3204 +Deceleration point: Home switch (HW)
3205 +
3206 +① The deceleration point signal is invalid when starting homing
3207 +
3208 +[[image:file:///C:\Users\Administrator\AppData\Local\Temp\ksohtml22584\wps12.png]]
3209 +
3210 +When starting to homing, HW=0, directly reverse low speed starts to homing, and the first Z signal stops after encountering the rising edge of HW;
3211 +
3212 +
3213 +② The deceleration point signal is valid when starting homing
3214 +
3215 +[[image:file:///C:\Users\Administrator\AppData\Local\Temp\ksohtml22584\wps13.png]]
3216 +
3217 +When starting to homing, HW = 1, start to homing at a forward high speed, after encountering the falling edge of HW, decelerate and reverse, run at a reverse low speed, and stop at the first Z signal after encountering the rising edge of HW.
3218 +
3219 +
3220 +
3221 +
3222 +
3223 +(7) P01-40=7
3224 +
3225 +Mechanical homing: Motor Z signal
3226 +
3227 +Deceleration point: Home switch (HW)
3228 +
3229 +① The deceleration point signal is invalid when starting homing, the forward limit switch is not encountered
3230 +
3231 +[[image:file:///C:\Users\Administrator\AppData\Local\Temp\ksohtml22584\wps14.png]]
3232 +
3233 +When it starts to homing, HW = 0, and it starts to homing at a forward high speed. If the limit switch is not encountered, after encountering the rising edge of HW, it decelerates and reverses the direction, and runs at a reverse low speed. The first Z signal after encountering the falling edge of HW stops.
3234 +
3235 +
3236 +When homing, the deceleration point signal is invalid and the forward limit switch is encountered
3237 +
3238 +[[image:file:///C:\Users\Administrator\AppData\Local\Temp\ksohtml22584\wps15.jpg]]
3239 +
3240 +When it starts to homing, HW = 0, and it starts to homing at a forward high speed. If it encounters a limit switch, it will automatically reverse and run at a reverse high speed. After encountering the rising edge of HW, it will slow down and continue to run at a reverse low speed. The first Z signal after the falling edge of HW will stop.
3241 +
3242 +
3243 +③ The deceleration point signal is valid when starting homing
3244 +
3245 +[[image:file:///C:\Users\Administrator\AppData\Local\Temp\ksohtml22584\wps16.png]]
3246 +
3247 +When starting homing, HW=1, then directly reverse the low speed to start homing, and stop the first Z signal after encountering the falling edge of HW;
3248 +
3249 +
3250 +(8) P01-40=8
3251 +
3252 +Mechanical homing: Motor Z signal
3253 +
3254 +Deceleration point: Home switch (HW)
3255 +
3256 +① The deceleration point signal is invalid when starting homing, the forward limit switch is not encountered
3257 +
3258 +[[image:file:///C:\Users\Administrator\AppData\Local\Temp\ksohtml22584\wps17.png]]
3259 +
3260 +When it starts to homing, HM-0 starts to homing at a forward high speed. If it does not encounter the limit switch, after encountering the rising edge of HW, slow down and reverse, and run at a reverse low speed. After encountering the falling edge of HW, reverse, run at a forward low speed, and stop at the first Z signal after encountering the rising edge of HW.
3261 +
3262 +
3263 +① The deceleration point signal is invalid when starting homing, the forward limit switch is encountered
3264 +
3265 +[[image:file:///C:\Users\Administrator\AppData\Local\Temp\ksohtml22584\wps18.png]]
3266 +
3267 +When it starts to homing, HW = 0, and it starts to homing at forward high speed. If it encounters a limit switch, it will automatically reverse and run at reverse high speed; After encountering the rising edge of HW, slow down and run at a reverse low speed; After encountering the falling edge of HW, reverse the direction, run at a forward low speed, and stop the first Z signal after encountering the rising edge of HW.
3268 +
3269 +
3270 +③ The deceleration point signal is valid when starting homing
3271 +
3272 +[[image:file:///C:\Users\Administrator\AppData\Local\Temp\ksohtml22584\wps19.png]]
3273 +
3274 +When starting to homing, HM-1 will directly reverse and start to return to zero at low speed. After encountering the falling edge of HW, it will reverse and run at forward low speed. The first Z signal after encountering the rising edge of HW will stop.
3275 +
3276 +
3277 +
3278 +(9) P01-40=9
3279 +
3280 +Mechanical homing: Motor Z signal
3281 +
3282 +Deceleration point: Home switch (HW)
3283 +
3284 +① The deceleration point signal is invalid when starting homing, the forward limit switch is not encountered
3285 +
3286 +[[image:file:///C:\Users\Administrator\AppData\Local\Temp\ksohtml22584\wps20.png]]
3287 +
3288 +When it starts to homing, HW=0, and it starts to homing at a forward high speed. If the limit switch is not encountered, after encountering the rising edge of HW, it decelerates and runs at a forward low speed; After encountering the falling edge of HW, reverse, run at a low speed in the reverse direction, and stop at the first Z signal after encountering the rising edge of HW.
3289 +
3290 +
3291 +① The deceleration point signal is invalid when starting homing, the forward limit switch is encountered
3292 +
3293 +[[image:file:///C:\Users\Administrator\AppData\Local\Temp\ksohtml22584\wps21.png]]
3294 +
3295 +When it starts to homing, HW = 0, and it starts to homing at a forward high speed. If it encounters a limit switch, it will automatically reverse and run at a reverse high speed. After encountering a rising edge of HW, it will slow down and reverse to resume forward operation. Running at a forward low speed, after encountering a falling edge of HW, it will reverse. During reverse low speed operation, the first Z signal after encountering a rising edge of HW will stop.
3296 +
3297 +③ The deceleration point signal is valid when starting homing
3298 +
3299 +[[image:file:///C:\Users\Administrator\AppData\Local\Temp\ksohtml22584\wps22.png]]
3300 +
3301 +When starting homing, HW=1 starts homing directly at forward low speed. After encountering the falling edge of HW, the first Z signal after encountering the rising edge of HW stops in reverse and reverse low speed operation;
3302 +
3303 +
3304 +(10) P01-40=10
3305 +
3306 +Mechanical homing: Motor Z signal
3307 +
3308 +Deceleration point: Home switch (HW)
3309 +
3310 +① The deceleration point signal is invalid when starting homing, the forward limit switch is not encountered
3311 +
3312 +[[image:file:///C:\Users\Administrator\AppData\Local\Temp\ksohtml22584\wps23.png]]
3313 +
3314 +When it starts to homing, HW = 0, and it starts to homing at a forward high speed. If the limit switch is not encountered, after encountering the rising edge of HW, slow down and run at a forward low speed. After encountering the falling edge of HW, continue to run at a forward low speed, and then the first Z signal encountered stops.
3315 +
3316 +When homing, the deceleration point signal is invalid and the forward limit switch is encountered
3317 +
3318 +[[image:file:///C:\Users\Administrator\AppData\Local\Temp\ksohtml22584\wps24.jpg]]
3319 +
3320 +When it starts to homing, HW = 0, and it starts to homing at a forward high speed. If it encounters a limit switch, it will automatically reverse and run at a reverse high speed. After encountering the rising edge of HW, it will slow down and reverse to resume forward operation. The first Z signal after the low speed encounters the falling edge of HW will stop.
3321 +
3322 +
3323 +③ The deceleration point signal is valid when starting homing
3324 +
3325 +[[image:file:///C:\Users\Administrator\AppData\Local\Temp\ksohtml22584\wps25.png]]
3326 +
3327 +When starting homing, HW=1, it will start homing directly at low speed, and the first Z signal after encountering the falling edge of HW will stop;
3328 +
3329 +
3330 +(11) P01-40=11
3331 +
3332 +Mechanical homing: Motor Z signal
3333 +
3334 +Deceleration point: Home switch (HW)
3335 +
3336 +① The deceleration point signal is invalid when starting homing, the reverse limit switch is not encountered
3337 +
3338 +[[image:file:///C:\Users\Administrator\AppData\Local\Temp\ksohtml22584\wps26.png]]
3339 +
3340 +When it starts to homing, HW=0, and it starts to homing at a reverse high speed. If the limit switch is not encountered, after encountering the rising edge of HW, it decelerates and reverses the direction, runs at a forward low speed, and stops at the first Z signal after encountering the falling edge of HW.
3341 +
3342 +
3343 +① The deceleration point signal is invalid when starting homing, the reverse limit switch is encountered
3344 +
3345 +[[image:file:///C:\Users\Administrator\AppData\Local\Temp\ksohtml22584\wps27.png]]
3346 +
3347 +When it starts to homing, HW=0, and it starts to homing at a reverse high speed. If it encounters a limit switch, it will automatically reverse and run at a forward high speed. After encountering a rising edge of HW, slow down and continue to run at a forward low speed. When encountering a falling edge of HW, the first Z signal after the edge stops.
3348 +
3349 +③ The deceleration point signal is valid when starting homing
3350 +
3351 +[[image:file:///C:\Users\Administrator\AppData\Local\Temp\ksohtml22584\wps28.png]]
3352 +
3353 +When starting homing, HW=1, it will start homing directly at low speed, and the first Z signal after encountering the falling edge of HW will stop;
3354 +
3355 +
3356 +(12) P01-40=12
3357 +
3358 +Mechanical homing: Motor Z signal
3359 +
3360 +Deceleration point: Home switch (HW)
3361 +
3362 +① The deceleration point signal is invalid when starting homing, the reverse limit switch is not encountered
3363 +
3364 +[[image:file:///C:\Users\Administrator\AppData\Local\Temp\ksohtml22584\wps29.png]]
3365 +
3366 +When it starts to homing, HW = 0, it starts to homing at a reverse high speed, and does not encounter a limit switch. After encountering the rising edge of HW, it decelerates and reverses, and runs at a forward low speed. After encountering the falling edge of HW, it reverses and runs at a reverse low speed, and stops at the first Z signal after encountering the rising edge of HW.
3367 +
3368 +
3369 +
3370 +① The deceleration point signal is invalid when starting homing, the reverse limit switch is encountered
3371 +
3372 +[[image:file:///C:\Users\Administrator\AppData\Local\Temp\ksohtml22584\wps30.png]]
3373 +
3374 +When it starts to homing, HW=0, it starts to homing at a reverse high speed, encounters a limit switch, automatically reverses, runs at a forward high speed, encounters a rising edge of HW, decelerates, runs at a forward low speed, encounters a falling edge of HW, reverses, runs at a reverse low speed, and stops at the first Z signal after encountering a rising edge of HW.
3375 +
3376 +
3377 +③ The deceleration point signal is valid when starting homing
3378 +
3379 +[[image:file:///C:\Users\Administrator\AppData\Local\Temp\ksohtml22584\wps31.png]]
3380 +
3381 +When starting to homing, HW = 1, it will directly start to homing at a forward low speed. After encountering the falling edge of HW, it will reverse and run at a reverse low speed. The first Z signal after encountering the rising edge of HW will stop.
3382 +
3383 +(13) P01-40=13
3384 +
3385 +Mechanical homing: Motor Z signal
3386 +
3387 +Deceleration point: Home switch (HW)
3388 +
3389 +① The deceleration point signal is invalid when starting homing, the reverse limit switch is not encountered
3390 +
3391 +[[image:file:///C:\Users\Administrator\AppData\Local\Temp\ksohtml22584\wps32.png]]
3392 +
3393 +When it starts to homing, HW=0, and it starts to homing at a reverse high speed. If it does not encounter the limit switch, after encountering the rising edge of HW, slow down and run at a reverse low speed. After encountering the falling edge of HW, reverse and run at a forward low speed, and stop at the first Z signal after encountering the rising edge of HW.
3394 +
3395 +
3396 +① The deceleration point signal is invalid when starting homing, the reverse limit switch is encountered
3397 +
3398 +[[image:file:///C:\Users\Administrator\AppData\Local\Temp\ksohtml22584\wps33.png]]
3399 +
3400 +When it starts to homing, HW=0, it starts to homing at reverse high speed, encounters the limit switch, automatically reverses, runs at forward high speed, after encountering the rising edge of HW, decelerates and runs in reverse low speed, and encounters the falling edge of HW when running at reverse low speed, the first Z signal after encountering the rising edge of HW stops.
3401 +
3402 +③ The deceleration point signal is valid when starting homing
3403 +
3404 +[[image:file:///C:\Users\Administrator\AppData\Local\Temp\ksohtml22584\wps34.png]]
3405 +
3406 +When starting homing, HW=1 starts homing directly at reverse low speed. After encountering the falling edge of HW, the first Z signal after encountering the rising edge of HW stops in reverse and forward low speed operation;
3407 +
3408 +
3409 +(14) P01-40=14
3410 +
3411 +Mechanical homing: Motor Z signal
3412 +
3413 +Deceleration point: Home switch (HW)
3414 +
3415 +① The deceleration point signal is invalid when starting homing, the reverse limit switch is not encountered
3416 +
3417 +[[image:file:///C:\Users\Administrator\AppData\Local\Temp\ksohtml22584\wps35.png]]
3418 +
3419 +When it starts to homing, HW=0, it starts to homing at reverse high speed, and does not encounter the limit switch. After encountering the rising edge of HW, it decelerates and runs at reverse low speed. After encountering the falling edge of HW, it continues to run at reverse low speed, and then the first Z signal encountered stops.
3420 +
3421 +
3422 +① The deceleration point signal is invalid when starting homing, the reverse limit switch is encountered
3423 +
3424 +[[image:file:///C:\Users\Administrator\AppData\Local\Temp\ksohtml22584\wps36.png]]
3425 +
3426 +When it starts to homing, HW = 0, it starts to homing at a reverse high speed, encounters a limit switch, automatically reverses, runs at a forward high speed, encounters a rising edge of HW, decelerates and runs in a reverse direction, and stops the first Z signal after encountering a falling edge of HW at a reverse low speed.
3427 +
3428 +
3429 +③ The deceleration point signal is valid when starting homing
3430 +
3431 +[[image:file:///C:\Users\Administrator\AppData\Local\Temp\ksohtml22584\wps37.png]]
3432 +
3433 +When starting homing, HW=1, then directly reverse the low speed to start homing, and stop the first Z signal after encountering the falling edge of HW;
3434 +
3435 +
3436 +(15) P01-40=17
3437 +
3438 +Mechanical homing: Negative overrun switch (NOT)
3439 +
3440 +Deceleration point: Negative overrun switch (NOT)
3441 +
3442 +① The deceleration point signal is invalid when starting homing
3443 +
3444 +[[image:file:///C:\Users\Administrator\AppData\Local\Temp\ksohtml22584\wps38.png]]
3445 +
3446 +When it starts to homing, NOT = 0, it starts to homing at a high speed in the reverse direction. After encountering the rising edge of NOT, it decelerates and reverses the direction, runs at a low speed in the forward direction, and stops after encountering the falling edge of NOT.
3447 +
3448 +
3449 +② The deceleration point signal is valid when starting homing
3450 +
3451 +[[image:file:///C:\Users\Administrator\AppData\Local\Temp\ksohtml22584\wps39.png]]
3452 +
3453 +When starting homing, NOT=1, start homing directly at low speed, and stop after encountering the falling edge of NOT.
3454 +
3455 +
3456 +(16) P01-40=18
3457 +
3458 +Mechanical homing: Positive overrun switch (POT)
3459 +
3460 +Deceleration point: Positive overrun switch (POT)
3461 +
3462 +① The deceleration point signal is invalid when starting homing
3463 +
3464 +[[image:file:///C:\Users\Administrator\AppData\Local\Temp\ksohtml22584\wps40.png]]
3465 +
3466 +When it starts to return to zero, POT=0, it starts to homing at a forward high speed, after encountering the rising edge of POT, it decelerates and reverses, runs at a reverse low speed, and stops after encountering the falling edge of POT.
3467 +
3468 +
3469 +② The deceleration point signal is valid when starting homing
3470 +
3471 +[[image:file:///C:\Users\Administrator\AppData\Local\Temp\ksohtml22584\wps41.png]]
3472 +
3473 +When starting homing, POT=1, start homing at low speed in reverse directly, and stop when encountering POT falling edge;
3474 +
3475 +
3476 +
3477 +(17) P01-40=19
3478 +
3479 +Mechanical homing: Home switch (HW)
3480 +
3481 +Deceleration point: Home switch (HW)
3482 +
3483 +① The deceleration point signal is invalid when starting homing
3484 +
3485 +[[image:file:///C:\Users\Administrator\AppData\Local\Temp\ksohtml22584\wps42.png]]
3486 +
3487 +When it starts to homing, HW=0, and it starts to homing at a forward high speed. After encountering the rising edge of HW, it decelerates and reverses the direction, runs at a reverse low speed, and stops when encountering the falling edge of HW.
3488 +
3489 +
3490 +② The deceleration point signal is valid when starting homing
3491 +
3492 +[[image:file:///C:\Users\Administrator\AppData\Local\Temp\ksohtml22584\wps43.png]]
3493 +
3494 +When starting homing, HW=1, start homing at low speed in reverse directly, and stop when encountering HW falling edge;
3495 +
3496 +
3497 +(18) P01-40=20
3498 +
3499 +Mechanical homing: Home switch (HW)
3500 +
3501 +Deceleration point: Home switch (HW)
3502 +
3503 +① The deceleration point signal is invalid when starting homing
3504 +
3505 +[[image:file:///C:\Users\Administrator\AppData\Local\Temp\ksohtml22584\wps44.png]]
3506 +
3507 +When starting to homing, HW=0, directly start to homing at low speed, and stop after encountering the rising edge of HW;
3508 +
3509 +
3510 +② The deceleration point signal is valid when starting homing
3511 +
3512 +[[image:file:///C:\Users\Administrator\AppData\Local\Temp\ksohtml22584\wps45.png]]
3513 +
3514 +When starting to homing, HW = 1, start to homing at a high speed in the reverse direction. After encountering the falling edge of HW, slow down and reverse the direction, run at a low speed in the forward direction, and stop when encountering the rising edge of HW.
3515 +
3516 +
3517 +(19) P01-40=21
3518 +
3519 +Mechanical homing: Home switch (HW)
3520 +
3521 +Deceleration point: Home switch (HW)
3522 +
3523 +① The deceleration point signal is invalid when starting homing
3524 +
3525 +[[image:file:///C:\Users\Administrator\AppData\Local\Temp\ksohtml22584\wps46.png]]
3526 +
3527 +When it starts to homing, HW=0, it starts to homing at a reverse high speed. After encountering the rising edge of HW, it decelerates and reverses the direction, runs at a forward low speed, and stops when encountering the falling edge of HW.
3528 +
3529 +
3530 +② The deceleration point signal is valid when starting homing
3531 +
3532 +[[image:file:///C:\Users\Administrator\AppData\Local\Temp\ksohtml22584\wps47.png]]
3533 +
3534 +When starting back to zero, HW=1, it will start homing directly at low speed, and stop after encountering the falling edge of HW;
3535 +
3536 +
3537 +(20) P01-40=22
3538 +
3539 +Mechanical homing: Home switch (HW)
3540 +
3541 +Deceleration point: Home switch (HW)
3542 +
3543 +① The deceleration point signal is invalid when starting homing
3544 +
3545 +[[image:file:///C:\Users\Administrator\AppData\Local\Temp\ksohtml22584\wps48.png]]
3546 +
3547 +When starting to homing, HW=0, directly reverse low speed starts to homing, and stops when encountering HW rising edge;
3548 +
3549 +
3550 +Deceleration point signal is valid when homing start
3551 +
3552 +[[image:file:///C:\Users\Administrator\AppData\Local\Temp\ksohtml22584\wps49.jpg]]
3553 +
3554 +When starting to homing, HW=1, start to homing at a forward high speed, after encountering the falling edge of HW, slow down and reverse, run at a reverse low speed, and stop when encountering the rising edge of HW.
3555 +
3556 +
3557 +(21) P01-40=23
3558 +
3559 +Mechanical homing: Home switch (HW)
3560 +
3561 +Deceleration point: Home switch (HW)
3562 +
3563 +① The deceleration point signal is invalid when starting homing, the forward limit switch is not encountered
3564 +
3565 +[[image:file:///C:\Users\Administrator\AppData\Local\Temp\ksohtml22584\wps50.png]]
3566 +
3567 +When it starts to homing, HW = 0, it starts to homing at a forward high speed, and does not encounter a limit switch. After encountering the rising edge of HW, it decelerates and reverses, runs at a reverse low speed, and stops when encountering the falling edge of HW.
3568 +
3569 +
3570 +① The deceleration point signal is invalid when starting homing, the forward limit switch is encountered
3571 +
3572 +[[image:file:///C:\Users\Administrator\AppData\Local\Temp\ksohtml22584\wps51.png]]
3573 +
3574 +When you start homing, HW = 0, start homing at a forward high speed. When encountering the limit switch, it will automatically reverse and run at a reverse high speed. After encountering the rising edge of HW, slow down, continue to run at reverse low speed, and stop when encountering the HW falling edge.
3575 +
3576 +
3577 +
3578 +③ The deceleration point signal is valid when starting homing
3579 +
3580 +[[image:file:///C:\Users\Administrator\AppData\Local\Temp\ksohtml22584\wps52.png]]
3581 +
3582 +When it starts to homing, HW=1, it starts to homing at a reverse low speed, and stops when it encounters the falling edge of HW.
3583 +
3584 +
3585 +(22) P01-40=24
3586 +
3587 +Mechanical homing: Home switch (HW)
3588 +
3589 +Deceleration point: Home switch (HW)
3590 +
3591 +① The deceleration point signal is invalid when starting homing, the forward limit switch is not encountered
3592 +
3593 +[[image:file:///C:\Users\Administrator\AppData\Local\Temp\ksohtml22584\wps53.png]]
3594 +
3595 +When it starts to homing, HW = 0, it starts to homing at a forward high speed, and does not encounter a limit switch. After encountering the rising edge of HW, it decelerates and reverses, and runs at a reverse low speed. After encountering the falling edge of HW, it reverses and runs at a forward low speed, and stops when encountering the rising edge of HW.
3596 +
3597 +
3598 +① The deceleration point signal is invalid when starting homing, the forward limit switch is encountered
3599 +
3600 +[[image:file:///C:\Users\Administrator\AppData\Local\Temp\ksohtml22584\wps54.png]]
3601 +
3602 +When it starts to homing, HW = 0, it starts to homing at forward high speed, encounters the limit switch, automatically reverses, runs at reverse high speed, encounters the rising edge of HW, decelerates and runs at reverse low speed, encounters the falling edge of HW, reverses, runs at forward low speed, and stops when encountering the rising edge of HW.
3603 +
3604 +
3605 +③ The deceleration point signal is valid when starting homing
3606 +
3607 +[[image:file:///C:\Users\Administrator\AppData\Local\Temp\ksohtml22584\wps55.png]]
3608 +
3609 +When starting with homing, HW = 1, it will directly reverse the low speed and start to homing. After encountering the falling edge of HW, it will reverse the direction and run at a forward low speed, and stop when encountering the rising edge of HW.
3610 +
3611 +
3612 +(23) P01-40=25
3613 +
3614 +Mechanical homing: Home switch (HW)
3615 +
3616 +Deceleration point: Home switch (HW)
3617 +
3618 +① The deceleration point signal is invalid when starting homing, the forward limit switch is not encountered
3619 +
3620 +[[image:file:///C:\Users\Administrator\AppData\Local\Temp\ksohtml22584\wps56.png]]
3621 +
3622 +When it starts to homing, HW=0, it starts to homing at a forward high speed, and does not encounter a limit switch. After encountering the rising edge of HW, it decelerates and runs at a forward low speed. After encountering the falling edge of HW, it reverses and runs at a reverse low speed, and stops when encountering the rising edge of HW.
3623 +
3624 +
3625 +① The deceleration point signal is invalid when starting homing, the forward limit switch is encountered
3626 +
3627 +[[image:file:///C:\Users\Administrator\AppData\Local\Temp\ksohtml22584\wps57.png]]
3628 +
3629 +When it starts to homing, HW=0, it starts to homing at forward high speed, encounters the limit switch, automatically reverses, and runs at reverse high speed. After encountering the rising edge of HW, decelerate and reverse to resume forward operation. After encountering the falling edge of HW at forward low speed, reverse. When running at reverse low speed, stop when encountering the rising edge of HW.
3630 +
3631 +
3632 +③ The deceleration point signal is valid when starting homing
3633 +
3634 +[[image:file:///C:\Users\Administrator\AppData\Local\Temp\ksohtml22584\wps58.png]]
3635 +
3636 +When starting homing, when HW=1, it starts to homing directly at low speed in the forward direction. After encountering the falling edge of HW, it stops at the rising edge of HW in the reverse low speed operation
3637 +
3638 +
3639 +(24) P01-40=26
3640 +
3641 +Mechanical homing: Home switch (HW)
3642 +
3643 +Deceleration point: Home switch (HW)
3644 +
3645 +① The deceleration point signal is invalid when starting homing, the forward limit switch is not encountered
3646 +
3647 +[[image:file:///C:\Users\Administrator\AppData\Local\Temp\ksohtml22584\wps59.png]]
3648 +
3649 +When it starts to homing, HW=0, it starts to homing at a forward high speed, and does not encounter a limit switch. After encountering the rising edge of HW, it decelerates, runs at a forward low speed, and stops when encountering the falling edge of HW.
3650 +
3651 +
3652 +① The deceleration point signal is invalid when starting homing, the forward limit switch is encountered
3653 +
3654 +[[image:file:///C:\Users\Administrator\AppData\Local\Temp\ksohtml22584\wps60.png]]
3655 +
3656 +When it starts to homing, HW=0, it starts to homing at forward high speed, encounters the limit switch, automatically reverses, and runs at reverse high speed. After encountering the rising edge of HW, decelerates and reverses to resume forward operation, and stops when encountering the falling edge of HW at forward low speed.
3657 +
3658 +
3659 +③ The deceleration point signal is valid when starting homing
3660 +
3661 +[[image:file:///C:\Users\Administrator\AppData\Local\Temp\ksohtml22584\wps61.png]]
3662 +
3663 +When starting homing, HW=1, it will start homing directly at low speed, and stop when encountering HW falling edge;
3664 +
3665 +
3666 +(25) P01-40=27
3667 +
3668 +Mechanical homing: Home switch (HW)
3669 +
3670 +Deceleration point: Home switch (HW)
3671 +
3672 +① The deceleration point signal is invalid when starting homing, the reverse limit switch is not encountered
3673 +
3674 +[[image:file:///C:\Users\Administrator\AppData\Local\Temp\ksohtml22584\wps62.png]]
3675 +
3676 +When it starts to homing, HW=0, it starts to homing at a reverse high speed, and does not encounter a limit switch. After encountering the rising edge of HW, it decelerates and reverses the direction, runs at a forward low speed, and stops when encountering the falling edge of HW.
3677 +
3678 +
3679 +① The deceleration point signal is invalid when starting homing, the reverse limit switch is encountered
3680 +
3681 +[[image:file:///C:\Users\Administrator\AppData\Local\Temp\ksohtml22584\wps63.png]]
3682 +
3683 +When it starts to homing, HW=0, it starts to homing at a reverse high speed. When it encounters a limit switch, it automatically reverses and runs at a forward high speed. When it encounters a rising edge of HW, it decelerates and continues to run at a forward low speed. When it encounters a falling edge of HW, it stops.
3684 +
3685 +
3686 +③ The deceleration point signal is valid when starting homing
3687 +
3688 +[[image:file:///C:\Users\Administrator\AppData\Local\Temp\ksohtml22584\wps64.png]]
3689 +
3690 +When starting homing, HW=1, it will start homing directly at low speed, and stop when encountering HW falling edge;
3691 +
3692 +
3693 +(26) P01-40=28
3694 +
3695 +Mechanical homing: Home switch (HW)
3696 +
3697 +Deceleration point: Home switch (HW)
3698 +
3699 +① The deceleration point signal is invalid when starting homing, the reverse limit switch is not encountered
3700 +
3701 +[[image:file:///C:\Users\Administrator\AppData\Local\Temp\ksohtml22584\wps65.png]]
3702 +
3703 +When it starts to homing, HW=0, it starts to homing at a reverse high speed, and does not encounter a limit switch. After encountering the rising edge of HW, it decelerates and reverses, and runs at a forward low speed. After encountering the falling edge of HW, it reverses and runs at a reverse low speed, and stops when encountering the rising edge of HW.
3704 +
3705 +
3706 +① The deceleration point signal is invalid when starting homing, the reverse limit switch is encountered
3707 +
3708 +[[image:file:///C:\Users\Administrator\AppData\Local\Temp\ksohtml22584\wps66.png]]
3709 +
3710 +When it starts to homing, HW=0, it starts to homing at a reverse high speed. When encountering a limit switch, it automatically reverses and runs at a forward high speed. When encountering a rising edge of HW, it decelerates and runs at a forward low speed. When encountering a falling edge of HW, it reverses and runs at a reverse low speed. When encountering a rising edge of HW, it stops.
3711 +
3712 +
3713 +③ The deceleration point signal is valid when starting homing
3714 +
3715 +[[image:file:///C:\Users\Administrator\AppData\Local\Temp\ksohtml22584\wps67.png]]
3716 +
3717 +When starting with homing, HW = 1, it will directly start to homing at a forward low speed. After encountering the falling edge of HW, it will reverse and run at a reverse low speed. When encountering the rising edge of HW, it will stop.
3718 +
3719 +
3720 +(27) P01-40=29
3721 +
3722 +Mechanical homing: Home switch (HW)
3723 +
3724 +Deceleration point: Home switch (HW)
3725 +
3726 +① The deceleration point signal is invalid when starting homing, the reverse limit switch is not encountered
3727 +
3728 +[[image:file:///C:\Users\Administrator\AppData\Local\Temp\ksohtml22584\wps68.png]]
3729 +
3730 +When it starts to homing, HW = 0, it starts to homing at a reverse high speed, and does not encounter a limit switch. After encountering the rising edge of HW, it decelerates and runs at a reverse low speed. After encountering the falling edge of HW, it reverses and runs at a forward low speed, and stops when encountering the rising edge of HW.
3731 +
3732 +
3733 +① The deceleration point signal is invalid when starting homing, the reverse limit switch is encountered
3734 +
3735 +[[image:file:///C:\Users\Administrator\AppData\Local\Temp\ksohtml22584\wps69.png]]
3736 +
3737 +When it starts to homing, HW=0, it starts to homing at a reverse high speed. When it encounters a limit switch, it automatically reverses and runs at a forward high speed. After encountering a rising edge of HW, it decelerates and runs in a reverse low speed. After encountering a falling edge of HW, it reverses. When running at a forward low speed, it stops when it encounters a rising edge of HW.
3738 +
3739 +③ The deceleration point signal is valid when starting homing
3740 +
3741 +[[image:file:///C:\Users\Administrator\AppData\Local\Temp\ksohtml22584\wps70.png]]
3742 +
3743 +When starting homing, when HW=1, it starts to homing directly at low speed in reverse direction. After encountering the falling edge of HW, it stops when running at low speed in reverse direction and forward direction and encountering the rising edge of HW
3744 +
3745 +
3746 +(28) P01-40=30
3747 +
3748 +Mechanical homing: Home switch (HW)
3749 +
3750 +Deceleration point: Home switch (HW)
3751 +
3752 +① The deceleration point signal is invalid when starting homing, the reverse limit switch is not encountered
3753 +
3754 +[[image:file:///C:\Users\Administrator\AppData\Local\Temp\ksohtml22584\wps71.png]]
3755 +
3756 +When it starts to homing, HW=0, it starts to homing at reverse high speed, and does not encounter the limit switch. After encountering the rising edge of HW, it decelerates, runs at reverse low speed, and stops when encountering the falling edge of HW.
3757 +
3758 +
3759 +① The deceleration point signal is invalid when starting homing, the reverse limit switch is encountered
3760 +
3761 +[[image:file:///C:\Users\Administrator\AppData\Local\Temp\ksohtml22584\wps72.png]]
3762 +
3763 +When it starts to homing, HW=0, it starts to homing at a reverse high speed. When it encounters a limit switch, it automatically reverses and runs at a forward high speed. When it encounters a rising edge of HW, it decelerates and runs in a reverse low speed. When it encounters a falling edge of HW, it stops.
3764 +
3765 +
3766 +③ The deceleration point signal is valid when starting homing
3767 +
3768 +[[image:file:///C:\Users\Administrator\AppData\Local\Temp\ksohtml22584\wps73.png]]
3769 +
3770 +When starting homing, HW=1, start homing at low speed in reverse directly, and stop when encountering HW falling edge;
3771 +
3772 +
3773 +(29) P01-40=33 and P01-40=34
3774 +
3775 +Mechanical homing: Z signal.
3776 +
3777 +Deceleration point: None
3778 +
3779 +Homing mode 33: Reverse low speed operation, stop the first Z signal encountered
3780 +
3781 +Homing mode 34: running at low speed in forward direction, stopping the first Z signal encountered
3782 +
3783 +[[image:file:///C:\Users\Administrator\AppData\Local\Temp\ksohtml22584\wps74.png]]
3784 +
3785 +
3786 +(30) P01-40=35
3787 +
3788 +Homing mode 35, taking the current position as the mechanical homing, after triggering the homing (P01-39: 0x00→0x01/0x00 → 0x02);
3789 +
3790 +After the homing is completed, according to the set value of P10-08 (homing bias compensation), P10-06 (encoder multi-turn reset operation) is executed.
3791 +
3792 +
3793 +