Changes for page 06 Operation
Last modified by Iris on 2025/08/08 14:40
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -1477,7 +1477,7 @@ 1477 1477 |135|P-NEAR (positioning approach)| |146|COM_VDO1(Communication VDO2 output) 1478 1478 |136|V-COIN (consistent speed)| |147|COM_VDO1(communication VDO3 output) 1479 1479 |137|V-NEAR (speed approach)| |148|COM_VDO1(communication VDO4 output) 1480 -|138|T-COIN (torque arrival)| | 1480 +|138|T-COIN (torque arrival)| |149|HOME_ATTAIN (Homing arrived) 1481 1481 1482 1482 When P06-32 is set to a value other than the above table, it is considered to not use DO port function. 1483 1483 ... ... @@ -1492,6 +1492,8 @@ 1492 1492 ② Only in the VD2-0xxSA1H model, the default function code for the DO_1 channel function selection is 130ALM (fault signal)! In the VD2-0xxSA1H model, the function code for the DO_2, DO_3, and DO_4 channels are 143 OZ (Z/A/B pulse output), and these 3 channels correspond to the Z-axis, A-axis, and B-axis of the pulse output respectively! 1493 1493 1494 1494 ③ The function selection code of DO_2, DO_3 and DO_4 channels in the VD2L-0xxSA1P model are 143 OZ (Z pulse output), and these 3 channels correspond to Z axis, pulse axis, and direction axis of the pulse output respectively! 1495 + 1496 +④VD2L does not support function code 149. 1495 1495 ))) 1496 1496 1497 1497 = **Speed control mode** = ... ... @@ -1518,8 +1518,9 @@ 1518 1518 )))|(% style="width:125px" %)((( 1519 1519 Effective immediately 1520 1520 )))|(% style="width:85px" %)0|(% style="width:75px" %)0 to 1|(% style="width:310px" %)((( 1521 -* 0: internal speed instruction 1522 -* 1: AI_1 analog input (not supported by VD2F) 1523 +0: internal speed instruction 1524 + 1525 +1: AI_1 analog input (not supported by **VD2F and VD2L**) 1523 1523 )))|- 1524 1524 1525 1525 Table 6-26 Speed instruction source parameter ... ... @@ -1550,15 +1550,17 @@ 1550 1550 Effective 1551 1551 1552 1552 immediately 1553 -)))|(% colspan="2" %)0|(% colspan="2" %)- 5000 to5000|(% colspan="2" %)(((1556 +)))|(% colspan="2" %)0|(% colspan="2" %)-6000 to 6000|(% colspan="2" %)((( 1554 1554 Internal speed instruction 0 1555 1555 1556 1556 When DI input port: 1557 1557 1558 -* 15-INSPD3: 0 1559 -* 14-INSPD2: 0 1560 -* 13-INSPD1: 0, 1561 +15-INSPD3: 0 1561 1561 1563 +14-INSPD2: 0 1564 + 1565 +13-INSPD1: 0, 1566 + 1562 1562 select this speed instruction to be effective. 1563 1563 )))|(% colspan="2" %)rpm 1564 1564 |=(% colspan="1" %)P01-23|(% colspan="2" %)((( ... ... @@ -1573,15 +1573,17 @@ 1573 1573 Effective 1574 1574 1575 1575 immediately 1576 -)))|(% colspan="2" %)0|(% colspan="2" %)- 5000 to5000|(% colspan="2" %)(((1581 +)))|(% colspan="2" %)0|(% colspan="2" %)-6000 to 6000|(% colspan="2" %)((( 1577 1577 Internal speed instruction 1 1578 1578 1579 1579 When DI input port: 1580 1580 1581 -* 15-INSPD3: 0 1582 -* 14-INSPD2: 0 1583 -* 13-INSPD1: 1, 1586 +15-INSPD3: 0 1584 1584 1588 +14-INSPD2: 0 1589 + 1590 +13-INSPD1: 1, 1591 + 1585 1585 Select this speed instruction to be effective. 1586 1586 )))|(% colspan="2" %)rpm 1587 1587 |=(% colspan="1" %)P01-24|(% colspan="2" %)((( ... ... @@ -1596,15 +1596,17 @@ 1596 1596 Effective 1597 1597 1598 1598 immediately 1599 -)))|(% colspan="2" %)0|(% colspan="2" %)- 5000 to5000|(% colspan="2" %)(((1606 +)))|(% colspan="2" %)0|(% colspan="2" %)-6000 to 6000|(% colspan="2" %)((( 1600 1600 Internal speed instruction 2 1601 1601 1602 1602 When DI input port: 1603 1603 1604 -* 15-INSPD3: 0 1605 -* 14-INSPD2: 1 1606 -* 13-INSPD1: 0, 1611 +15-INSPD3: 0 1607 1607 1613 +14-INSPD2: 1 1614 + 1615 +13-INSPD1: 0, 1616 + 1608 1608 Select this speed instruction to be effective. 1609 1609 )))|(% colspan="2" %)rpm 1610 1610 |=(% colspan="1" %)P01-25|(% colspan="2" %)((( ... ... @@ -1619,15 +1619,17 @@ 1619 1619 Effective 1620 1620 1621 1621 immediately 1622 -)))|(% colspan="2" %)0|(% colspan="2" %)- 5000 to5000|(% colspan="2" %)(((1631 +)))|(% colspan="2" %)0|(% colspan="2" %)-6000 to 6000|(% colspan="2" %)((( 1623 1623 Internal speed instruction 3 1624 1624 1625 1625 When DI input port: 1626 1626 1627 -* 15-INSPD3: 0 1628 -* 14-INSPD2: 1 1629 -* 13-INSPD1: 1, 1636 +15-INSPD3: 0 1630 1630 1638 +14-INSPD2: 1 1639 + 1640 +13-INSPD1: 1, 1641 + 1631 1631 Select this speed instruction to be effective. 1632 1632 )))|(% colspan="2" %)rpm 1633 1633 |=P01-26|(% colspan="2" %)((( ... ... @@ -1642,15 +1642,17 @@ 1642 1642 Effective 1643 1643 1644 1644 immediately 1645 -)))|(% colspan="2" %)0|(% colspan="2" %)- 5000 to5000|(% colspan="2" %)(((1656 +)))|(% colspan="2" %)0|(% colspan="2" %)-6000 to 6000|(% colspan="2" %)((( 1646 1646 Internal speed instruction 4 1647 1647 1648 1648 When DI input port: 1649 1649 1650 -* 15-INSPD3: 1 1651 -* 14-INSPD2: 0 1652 -* 13-INSPD1: 0, 1661 +15-INSPD3: 1 1653 1653 1663 +14-INSPD2: 0 1664 + 1665 +13-INSPD1: 0, 1666 + 1654 1654 Select this speed instruction to be effective. 1655 1655 )))|(% colspan="1" %)rpm 1656 1656 |=P01-27|(% colspan="2" %)((( ... ... @@ -1665,15 +1665,17 @@ 1665 1665 Effective 1666 1666 1667 1667 immediately 1668 -)))|(% colspan="2" %)0|(% colspan="2" %)- 5000 to5000|(% colspan="2" %)(((1681 +)))|(% colspan="2" %)0|(% colspan="2" %)-6000 to 6000|(% colspan="2" %)((( 1669 1669 Internal speed instruction 5 1670 1670 1671 1671 When DI input port: 1672 1672 1673 -* 15-INSPD3: 1 1674 -* 14-INSPD2: 0 1675 -* 13-INSPD1: 1, 1686 +15-INSPD3: 1 1676 1676 1688 +14-INSPD2: 0 1689 + 1690 +13-INSPD1: 1, 1691 + 1677 1677 Select this speed instruction to be effective. 1678 1678 )))|(% colspan="1" %)rpm 1679 1679 |=P01-28|(% colspan="2" %)((( ... ... @@ -1688,15 +1688,17 @@ 1688 1688 Effective 1689 1689 1690 1690 immediately 1691 -)))|(% colspan="2" %)0|(% colspan="2" %)- 5000 to5000|(% colspan="2" %)(((1706 +)))|(% colspan="2" %)0|(% colspan="2" %)-6000 to 6000|(% colspan="2" %)((( 1692 1692 Internal speed instruction 6 1693 1693 1694 1694 When DI input port: 1695 1695 1696 -* 15-INSPD3: 1 1697 -* 14-INSPD2: 1 1698 -* 13-INSPD1: 0, 1711 +15-INSPD3: 1 1699 1699 1713 +14-INSPD2: 1 1714 + 1715 +13-INSPD1: 0, 1716 + 1700 1700 Select this speed instruction to be effective. 1701 1701 )))|(% colspan="1" %)rpm 1702 1702 |=P01-29|(% colspan="2" %)((( ... ... @@ -1711,15 +1711,17 @@ 1711 1711 Effective 1712 1712 1713 1713 immediately 1714 -)))|(% colspan="2" %)0|(% colspan="2" %)- 5000 to5000|(% colspan="2" %)(((1731 +)))|(% colspan="2" %)0|(% colspan="2" %)-6000 to 6000|(% colspan="2" %)((( 1715 1715 Internal speed instruction 7 1716 1716 1717 1717 When DI input port: 1718 1718 1719 -* 15-INSPD3: 1 1720 -* 14-INSPD2: 1 1721 -* 13-INSPD1: 1, 1736 +15-INSPD3: 1 1722 1722 1738 +14-INSPD2: 1 1739 + 1740 +13-INSPD1: 1, 1741 + 1723 1723 Select this speed instruction to be effective. 1724 1724 )))|(% colspan="1" %)rpm 1725 1725 ... ... @@ -1735,12 +1735,13 @@ 1735 1735 The multi-speed segment number is a 3-bit binary number, and the DI terminal logic is level valid. When the input level is valid, the segment selection bit value is 1, otherwise it is 0. The corresponding relationship between INSPD1 to 3 and segment numbers is shown as below. 1736 1736 1737 1737 1738 -|=**INSPD3**|=**INSPD2**|=**INSPD1**|=**Running segment number**|=**Internal speed instruction number** 1739 -|0|0|0|1|0 1740 -|0|0|1|2|1 1741 -|0|1|0|3|2 1742 -|(% colspan="5" %)...... 1743 -|1|1|1|8|7 1757 +(% style="margin-left:auto; margin-right:auto" %) 1758 +|=(% style="text-align: center; vertical-align: middle;" %)**INSPD3**|=(% style="text-align: center; vertical-align: middle;" %)**INSPD2**|=(% style="text-align: center; vertical-align: middle;" %)**INSPD1**|=(% style="text-align: center; vertical-align: middle;" %)**Running segment number**|=(% style="text-align: center; vertical-align: middle;" %)**Internal speed instruction number** 1759 +|(% style="text-align:center; vertical-align:middle" %)0|(% style="text-align:center; vertical-align:middle" %)0|(% style="text-align:center; vertical-align:middle" %)0|(% style="text-align:center; vertical-align:middle" %)1|(% style="text-align:center; vertical-align:middle" %)0 1760 +|(% style="text-align:center; vertical-align:middle" %)0|(% style="text-align:center; vertical-align:middle" %)0|(% style="text-align:center; vertical-align:middle" %)1|(% style="text-align:center; vertical-align:middle" %)2|(% style="text-align:center; vertical-align:middle" %)1 1761 +|(% style="text-align:center; vertical-align:middle" %)0|(% style="text-align:center; vertical-align:middle" %)1|(% style="text-align:center; vertical-align:middle" %)0|(% style="text-align:center; vertical-align:middle" %)3|(% style="text-align:center; vertical-align:middle" %)2 1762 +|(% colspan="5" style="text-align:center; vertical-align:middle" %)...... 1763 +|(% style="text-align:center; vertical-align:middle" %)1|(% style="text-align:center; vertical-align:middle" %)1|(% style="text-align:center; vertical-align:middle" %)1|(% style="text-align:center; vertical-align:middle" %)8|(% style="text-align:center; vertical-align:middle" %)7 1744 1744 1745 1745 Table 6-29 Correspondence between INSPD bits and segment numbers 1746 1746 ... ... @@ -1781,16 +1781,22 @@ 1781 1781 ))) 1782 1782 1783 1783 |=(% scope="row" %)**Function code**|=**Name**|=**Setting method**|=**Effective time**|=**Default value**|=**Range**|=**Definition**|=**Unit** 1784 -|=P05-01☆|AI_1 input bias|Operation setting|Effective immediately|0|-5000 to 5000|Set AI_1 channel analog bias value|mV 1785 -|=P05-02☆|AI_1 input filter time constant|Operation setting|Effective immediately|200|0 to 60000|AI_1 channel input first-order low-pass filtering time constant|0.01ms 1786 -|=P05-03☆|AI_1 dead zone|Operation setting|Effective immediately|20|0 to 1000|Set AI_1 channel quantity dead zone value|mV 1787 -|=P05-04☆|AI_1 zero drift|Operation setting|Effective immediately|0|-500 to 500|Automatic calibration of zero drift inside the drive|mV 1804 +|=P05-01((( 1805 +★ 1806 +)))|AI_1 input bias|Operation setting|Effective immediately|0|-5000 to 5000|Set AI_1 channel analog bias value|mV 1807 +|=P05-02((( 1808 +★ 1809 +)))|AI_1 input filter time constant|Operation setting|Effective immediately|200|0 to 60000|AI_1 channel input first-order low-pass filtering time constant|0.01ms 1810 +|=P05-03((( 1811 +★ 1812 +)))|AI_1 dead zone|Operation setting|Effective immediately|20|0 to 1000|Set AI_1 channel quantity dead zone value|mV 1813 +|=P05-04((( 1814 +★ 1815 +)))|AI_1 zero drift|Operation setting|Effective immediately|0|-500 to 500|Automatic calibration of zero drift inside the drive|mV 1788 1788 1789 -Table 6-30 AI_1 parameters 1790 - 1791 1791 (% class="box infomessage" %) 1792 1792 ((( 1793 -✎**Note: **“ ☆” means VD2F servo drive does not support the function code .1819 +✎**Note: **“★” means VD2F and VD2L servo drive does not support the function code . 1794 1794 ))) 1795 1795 1796 1796 == Acceleration and deceleration time setting == ... ... @@ -1884,10 +1884,13 @@ 1884 1884 )))|0|0 to 3|((( 1885 1885 Set the zero-speed clamp function. In speed mode: 1886 1886 1887 -* 0: Force the speed to 0; 1888 -* 1: Force the speed to 0, and keep the position locked when the actual speed is less than P01-22 1889 -* 2: When speed instruction is less than P01-22, force the speed to 0 and keep the position locked 1890 -* 3: Invalid, ignore zero-speed clamp input 1913 +0: Force the speed to 0; 1914 + 1915 +1: Force the speed to 0, and keep the position locked when the actual speed is less than P01-22 1916 + 1917 +2: When speed instruction is less than P01-22, force the speed to 0 and keep the position locked 1918 + 1919 +3: Invalid, ignore zero-speed clamp input 1891 1891 )))|- 1892 1892 |=P01-22|((( 1893 1893 Zero-speed clamp speed threshold ... ... @@ -1895,7 +1895,7 @@ 1895 1895 Operation setting 1896 1896 )))|((( 1897 1897 Effective immediately 1898 -)))|20|0 to 1000|Set the speed threshold of zero-speed clamp function|rpm1927 +)))|20|0 to 6000|Set the speed threshold of zero-speed clamp function|rpm 1899 1899 1900 1900 Table 6-33 Zero-speed clamp related parameters 1901 1901 ... ... @@ -1940,7 +1940,7 @@ 1940 1940 1941 1941 |=(% scope="row" %)**DO function code**|=(% style="width: 247px;" %)**Function name**|=(% style="width: 695px;" %)**Function** 1942 1942 |=132|(% style="width:247px" %)((( 1943 -T -COIN rotation detection1972 +TGON rotation detection 1944 1944 )))|(% style="width:695px" %)((( 1945 1945 Valid: when the absolute value of motor speed after filtering is greater than or equal to the set value of function code P05-16 1946 1946 ... ... @@ -2008,7 +2008,7 @@ 2008 2008 2009 2009 |=(% scope="row" %)**DO Function code**|=(% style="width: 262px;" %)**Function name**|=(% style="width: 684px;" %)**Function** 2010 2010 |=136|(% style="width:262px" %)((( 2011 - U-COIN consistent speed2040 +V-COIN consistent speed 2012 2012 )))|(% style="width:684px" %)The output signal indicates that the absolute deviation of the actual speed of servo motor and the speed instruction meets the P05-17 set value 2013 2013 2014 2014 Table 6-39 DO speed consistent function code ... ... @@ -2192,8 +2192,9 @@ 2192 2192 )))|((( 2193 2193 Effective immediately 2194 2194 )))|0|0 to 1|((( 2195 -* 0: internal value 2196 -* 1: AI_1 analog input (not supported by VD2F and VD2L) 2224 +0: internal value 2225 + 2226 +1: AI_1 analog input (not supported by VD2F and VD2L) 2197 2197 )))|- 2198 2198 2199 2199 * Torque limit source is internal torque instruction (P01-14=0) ... ... @@ -2270,7 +2270,7 @@ 2270 2270 Operation setting 2271 2271 )))|((( 2272 2272 Effective immediately 2273 -)))|3000|0 to 5000|(((2303 +)))|3000|0 to 6000|((( 2274 2274 Forward torque 2275 2275 2276 2276 limit in torque mode ... ... @@ -2283,7 +2283,7 @@ 2283 2283 Operation setting 2284 2284 )))|((( 2285 2285 Effective immediately 2286 -)))|3000|0 to 5000|(((2316 +)))|3000|0 to 6000|((( 2287 2287 Reverse torque 2288 2288 2289 2289 limit in torque mode ... ... @@ -2368,13 +2368,18 @@ 2368 2368 )))|((( 2369 2369 Shutdown setting 2370 2370 )))|1|(% style="width:90px" %)1 to 6|(% style="width:273px" %)((( 2371 -* 1: Position control 2372 -* 2: Speed control 2373 -* 3: Torque control 2374 -* 4: Position/speed mixed control 2375 -* 5: Position/torque mixed control 2376 -* 6: Speed/torque mixed control 2401 +1: Position control 2377 2377 2403 +2: Speed control 2404 + 2405 +3: Torque control 2406 + 2407 +4: Position/speed mixed control 2408 + 2409 +5: Position/torque mixed control 2410 + 2411 +6: Speed/torque mixed control 2412 + 2378 2378 **VD2L drive P0-01 setting range: 1-3, not support mixed mode** 2379 2379 )))|- 2380 2380 ... ... @@ -2516,8 +2516,9 @@ 2516 2516 **time** 2517 2517 )))|=**Default value**|=**Range**|=**Definition**|=**Unit** 2518 2518 |=P00-30|Shield multi-turn absolute encoder battery fault|Operation setting|Power on again|0|0 to 1|((( 2519 -* 0:Detect multi-turn absolute encoder battery under voltage, and battery low voltage fault 2520 -* 1: (Not recommended) Shield multi-turn absolute motor battery failure alarm. Multi-turn absolute application may cause mechanical fault, only multi-turn absolute encoder motors is used as single-turn absolute 2554 +0:Detect multi-turn absolute encoder battery under voltage, and battery low voltage fault 2555 + 2556 +1: (Not recommended) Shield multi-turn absolute motor battery failure alarm. Multi-turn absolute application may cause mechanical fault, only multi-turn absolute encoder motors is used as single-turn absolute 2521 2521 )))|- 2522 2522 2523 2523 This function is permitted when a multi-turn absolute encoder motor is used as a single-turn absolute and when it is confirmed that no mechanical failure will occur. ... ... @@ -2662,8 +2662,9 @@ 2662 2662 2663 2663 VDI_1 input level: 2664 2664 2665 -* 0: low level 2666 -* 1: high level 2701 +0: Low level 2702 + 2703 +1: High level 2667 2667 )))|- 2668 2668 |=P13-2|Virtual VDI_2 input value|Operation setting|Effective immediately|0|0 to 1|((( 2669 2669 When P06-07 is set to 1, DI_2 channel logic is control by this function code. ... ... @@ -2670,8 +2670,9 @@ 2670 2670 2671 2671 VDI_2 input level: 2672 2672 2673 -* 0: low level 2674 -* 1: high level 2710 +0: Low level 2711 + 2712 +1: High level 2675 2675 )))|- 2676 2676 |=P13-3|Virtual VDI_3 input value|Operation setting|Effective immediately|0|0 to 1|((( 2677 2677 When P06-10 is set to 1, DI_3 channel logic is control by this function code. ... ... @@ -2678,8 +2678,9 @@ 2678 2678 2679 2679 VDI_3 input level: 2680 2680 2681 -* 0: low level 2682 -* 1: high level 2719 +0: Low level 2720 + 2721 +1: High level 2683 2683 )))|- 2684 2684 |=P13-4|Virtual VDI_4 input value|Operation setting|Effective immediately|0|0 to 1|((( 2685 2685 When P06-13 is set to 1, DI_4 channel logic is control by this function code. ... ... @@ -2686,40 +2686,53 @@ 2686 2686 2687 2687 VDI_4 input level: 2688 2688 2689 -* 0: low level 2690 -* 1: high level 2728 +0: Low level 2729 + 2730 +1: High level 2691 2691 )))|- 2692 -|=P13-05☆|Virtual VDI_5 input value|Operation setting|Effective immediately|0|0 to 1|((( 2732 +|=P13-05((( 2733 +★ 2734 +)))|Virtual VDI_5 input value|Operation setting|Effective immediately|0|0 to 1|((( 2693 2693 When P06-16 is set to 1, DI_5 channel logic is control by this function code. 2694 2694 2695 2695 VDI_5 input level: 2696 2696 2697 -* 0: low level 2698 -* 1: high level 2739 +0: Low level 2740 + 2741 +1: High level 2699 2699 )))|- 2700 -|=P13-06☆|Virtual VDI_6 input value|Operation setting|Effective immediately|0|0 to 1|((( 2743 +|=P13-06((( 2744 +★ 2745 +)))|Virtual VDI_6 input value|Operation setting|Effective immediately|0|0 to 1|((( 2701 2701 When P06-19 is set to 1, DI_6 channel logic is control by this function code. 2702 2702 2703 2703 VDI_6 input level: 2704 2704 2705 -* 0: low level 2706 -* 1: high level 2750 +0: Low level 2751 + 2752 +1: High level 2707 2707 )))|- 2708 -|=P13-07☆|Virtual VDI_7 input value|Operation setting|Effective immediately|0|0 to 1|((( 2754 +|=P13-07((( 2755 +★ 2756 +)))|Virtual VDI_7 input value|Operation setting|Effective immediately|0|0 to 1|((( 2709 2709 When P06-22 is set to 1, DI_7 channel logic is control by this function code. 2710 2710 2711 2711 VDI_7 input level: 2712 2712 2713 -* 0: low level 2714 -* 1: high level 2761 +0: Low level 2762 + 2763 +1: High level 2715 2715 )))|- 2716 -|=P13-08☆|Virtual VDI_8 input value|Operation setting|Effective immediately|0|0 to 1|((( 2765 +|=P13-08((( 2766 +★ 2767 +)))|Virtual VDI_8 input value|Operation setting|Effective immediately|0|0 to 1|((( 2717 2717 When P06-25 is set to 1, DI_8 channel logic is control by this function code. 2718 2718 2719 2719 VDI_8 input level: 2720 2720 2721 -* 0: low level 2722 -* 1: high level 2772 +0: Low level 2773 + 2774 +1: High level 2723 2723 )))|- 2724 2724 2725 2725 Table 6-57 Virtual VDI parameters ... ... @@ -2726,7 +2726,7 @@ 2726 2726 2727 2727 (% class="box infomessage" %) 2728 2728 ((( 2729 -✎**Note: **“ ☆” means VD2F servo drive does not support the function code .2781 +✎**Note: **“★” means VD2F and VD2L servo drive does not support the function code . 2730 2730 ))) 2731 2731 2732 2732 == Port filtering time == ... ... @@ -2760,26 +2760,30 @@ 2760 2760 |=P13-11|Communication VDO_1 output value|Operation setting|Effective immediately|0|0 to 1|((( 2761 2761 VDO_1 output level: 2762 2762 2763 -* 0: low level 2764 -* 1: high level 2815 +0: Low level 2816 + 2817 +1: High level 2765 2765 )))|- 2766 2766 |=P13-12|Communication VDO_2 output value|Operation setting|Effective immediately|0|0 to 1|((( 2767 2767 VDO_2 output level: 2768 2768 2769 -* 0: low level 2770 -* 1: high level 2822 +0: Low level 2823 + 2824 +1: High level 2771 2771 )))|- 2772 2772 |=P13-13|Communication VDO_3 output value|Operation setting|Effective immediately|0|0 to 1|((( 2773 2773 VDO_3 output level: 2774 2774 2775 -* 0: low level 2776 -* 1: high level 2829 +0: Low level 2830 + 2831 +1: High level 2777 2777 )))|- 2778 2778 |=P13-14|Communication VDO_4 output value|Operation setting|Effective immediately|0|0 to 1|((( 2779 2779 VDO_4 output level: 2780 2780 2781 -* 0: low level 2782 -* 1: high level 2836 +0: Low level 2837 + 2838 +1: High level 2783 2783 )))|- 2784 2784 2785 2785 Table 6-59 Communication control DO function parameters ... ... @@ -2822,3 +2822,916 @@ 2822 2822 ((( 2823 2823 ✎**Note:** It is advised to configure function codes for DO terminals in sequence to avoid errors. Please use the shielded overload protection fault detection function with caution, otherwise it will cause burn out the motor. 2824 2824 ))) 2881 + 2882 + 2883 +== Homing mode == 2884 + 2885 +The homing mode is used to find the mechanical origin and locate the positional relationship between the mechanical origin and the mechanical zero. 2886 + 2887 +Mechanical homing: A mechanically fixed position may correspond to a certain defined homing switch, or may correspond to the motor Z signal. 2888 + 2889 +Mechanical zero point: Mechanically absolute 0 position. 2890 + 2891 +After the homing, the stop position of the motor is the mechanical homing. By setting P10-08, the relationship between the mechanical homing and the mechanical zero can be set: 2892 + 2893 +Mechanical homing = Mechanical zero +P10-08 (homing offset) 2894 + 2895 +When P10-08=0, the mechanical homing coincides with the mechanical zero. 2896 + 2897 + 2898 +=== Control block diagram === 2899 + 2900 +[[image:file:///C:\Users\Administrator\AppData\Local\Temp\ksohtml22584\wps1.png]]Figure 6-53 Homing mode control block diagram 2901 + 2902 + 2903 + 2904 +=== Homing mode related function codes === 2905 + 2906 +|Function code|Name|((( 2907 +Setting 2908 + 2909 +method 2910 +)))|((( 2911 +Effective 2912 + 2913 +time 2914 +)))|Default|Range|Definition|Unit 2915 +|P01-39.|Homing start mode|((( 2916 +Stop 2917 + 2918 +settings 2919 +)))|((( 2920 +Immediately 2921 + 2922 +effective 2923 +)))|0|0 to 2|((( 2924 +0: Close 2925 + 2926 +1: The servo is powered ON and started after the first ON 2927 + 2928 +2: DI enable 2929 +)))|- 2930 + 2931 + 2932 +|Function code|Name|((( 2933 +Setting 2934 + 2935 +method 2936 +)))|((( 2937 +Effective 2938 + 2939 +time 2940 +)))|Default|Range|Definition|Unit 2941 +|P01-40|Homing mode|((( 2942 +Stop 2943 + 2944 +settings 2945 +)))|((( 2946 +Immediately 2947 + 2948 +effective 2949 +)))|0|0 to 35|((( 2950 +0 ~~ 35 Homing mode; 2951 + 2952 +✎Note: VD2 currently does not support 15, 16, 31, 32 modes 2953 +)))|- 2954 + 2955 +|Function code|Name|((( 2956 +Setting 2957 + 2958 +method 2959 +)))|((( 2960 +Effective 2961 + 2962 +time 2963 +)))|Default|Range|Definition|Unit 2964 +|P01-41|High-speed search deceleration point signal velocity|((( 2965 +Running 2966 + 2967 +settings 2968 +)))|((( 2969 +Immediately 2970 + 2971 +effective 2972 +)))|300|1 to 3000|High-speed search deceleration point signal velocity in homing mode|rpm 2973 + 2974 +|Function code|Name|((( 2975 +Setting 2976 + 2977 +method 2978 +)))|((( 2979 +Effective 2980 + 2981 +time 2982 +)))|Default|Range|Definition|Unit 2983 +|P01-42〇|Low speed search homing signal speed|((( 2984 +Running 2985 + 2986 +settings 2987 +)))|((( 2988 +Immediately 2989 + 2990 +effective 2991 +)))|60|1 to 300|Low-speed search origin signal velocity in homing mode|rpm 2992 + 2993 +|Function code|Name|((( 2994 +Setting 2995 + 2996 +method 2997 +)))|((( 2998 +Effective 2999 + 3000 +time 3001 +)))|Default|Range|Definition|Unit 3002 +|P01-43〇|Homing acceleration and deceleration|((( 3003 +Running 3004 + 3005 +settings 3006 +)))|((( 3007 +Immediately 3008 + 3009 +effective 3010 +)))|50|1to1000|((( 3011 +Acceleration and deceleration in homing mode 3012 + 3013 +Time for speed acceleration from 0 to 1000rpm 3014 +)))|ms 3015 + 3016 +|Function code|Name|((( 3017 +Setting 3018 + 3019 +method 3020 +)))|((( 3021 +Effective 3022 + 3023 +time 3024 +)))|Default|Range|Definition|Unit 3025 +|P01-44〇|Homing timeout limited time|((( 3026 +Running 3027 + 3028 +settings 3029 +)))|((( 3030 +Immediately 3031 + 3032 +effective 3033 +)))|65535|100 to 65535|Homing timeout limited time|ms 3034 + 3035 +|Function code|Name|((( 3036 +Setting 3037 + 3038 +method 3039 +)))|((( 3040 +Effective 3041 + 3042 +time 3043 +)))|Default|Range|Definition|Unit 3044 +|P10-08〇|Multi-turn absolute encoder homing offset compensation|((( 3045 +Running 3046 + 3047 +settings 3048 +)))|((( 3049 +Immediately 3050 + 3051 +effective 3052 +)))|0|((( 3053 +-2147483647~~ 3054 + 3055 +2147483646 3056 +)))|((( 3057 +P10-08 multi-turn absolute encoder homing offset compensation is used in conjunction with U0-56 multi-turn absolute encoder current position. 3058 + 3059 +When P10-6 is set to 1, the value of U0-56 is updated to P10-8. 3060 +)))|- 3061 + 3062 +== Introduction to homing mode == 3063 + 3064 +In the following figure, "H" represents P01-41 (high-speed search deceleration point signal speed), and "L" represents P01-42 (low-speed search homing signal speed). 3065 + 3066 + 3067 +(1) P01-40 =1 3068 + 3069 +Mechanical homing: Motor Z signal 3070 + 3071 +Deceleration point: Reverse limit switch (NOT) 3072 + 3073 +① The deceleration point signal is invalid when starting homing 3074 + 3075 +[[image:file:///C:\Users\Administrator\AppData\Local\Temp\ksohtml22584\wps2.png]] 3076 + 3077 +When it starts to homing, NOT=0, it starts to homing at a high speed in the reverse direction. After encountering the rising edge of NOT, it decelerates and reverses the direction, runs at a low speed in the forward direction, and stops at the first Z signal after encountering the falling edge of NOT. 3078 + 3079 + 3080 +② The deceleration point signal is valid when starting homing 3081 + 3082 +[[image:file:///C:\Users\Administrator\AppData\Local\Temp\ksohtml22584\wps3.png]] 3083 + 3084 +When starting to homing, NOT=1, it starts to homing at a direct forward low speed, and stops at the first Z signal after encountering the falling edge of NOT. 3085 + 3086 + 3087 + 3088 + 3089 + 3090 + 3091 +(2) P01-40=2 3092 + 3093 +Mechanical homing: Motor Z signal 3094 + 3095 +Deceleration point: Positive Limit Switch (POT) 3096 + 3097 +① The deceleration point signal is invalid when starting homing 3098 + 3099 +[[image:file:///C:\Users\Administrator\AppData\Local\Temp\ksohtml22584\wps4.png]] 3100 + 3101 +When it starts to homing, POT = 0, and it starts to homing at a forward high speed. After encountering the rising edge of POT, it decelerates and reverses, runs at a reverse low speed, and stops at the first Z signal after encountering the falling edge of POT. 3102 + 3103 + 3104 +② The deceleration point signal is valid when starting homing 3105 + 3106 +[[image:file:///C:\Users\Administrator\AppData\Local\Temp\ksohtml22584\wps5.png]] 3107 + 3108 +POT=1 when start homing, run at low speed directly in the reverse direction, and stops at the first Z signal after the falling edge of POT. 3109 + 3110 + 3111 + 3112 + 3113 + 3114 + 3115 + 3116 + 3117 + 3118 + 3119 + 3120 + 3121 + 3122 +(3) P01-40=3 3123 + 3124 +Mechanical homing: Motor Z signal 3125 + 3126 +Deceleration point: Home switch (HW) 3127 + 3128 +① The deceleration point signal is invalid when starting homing 3129 + 3130 +[[image:file:///C:\Users\Administrator\AppData\Local\Temp\ksohtml22584\wps6.png]] 3131 + 3132 +When it starts to homing, HW=0. It starts to homing at a forward high speed. After encountering the rising edge of HW, it decelerates and reverses the direction. It runs at a reverse low speed. After encountering the falling edge of HW, it continues to run, and then stops when encountering the first Z signal. 3133 + 3134 + 3135 +② The deceleration point signal is valid when starting homing 3136 + 3137 +[[image:file:///C:\Users\Administrator\AppData\Local\Temp\ksohtml22584\wps7.png]] 3138 + 3139 +When starting homing, HW=1, start homing at low speed in reverse directly, and stop at the first Z signal after encountering the falling edge of HW; 3140 + 3141 + 3142 + 3143 + 3144 + 3145 + 3146 + 3147 + 3148 + 3149 + 3150 + 3151 + 3152 + 3153 +(4) P01-40=4 3154 + 3155 +Mechanical homing: Motor Z signal 3156 + 3157 +Deceleration point: Home switch (HW) 3158 + 3159 +① The deceleration point signal is invalid when starting homing 3160 + 3161 +[[image:file:///C:\Users\Administrator\AppData\Local\Temp\ksohtml22584\wps8.png]] 3162 + 3163 +HW=0 when starting to homing, directly start to homing at low speed, and stop at the first Z signal after encountering the rising edge of HW; 3164 + 3165 + 3166 +② The deceleration point signal is valid when starting homing 3167 + 3168 +[[image:file:///C:\Users\Administrator\AppData\Local\Temp\ksohtml22584\wps9.jpg]] 3169 + 3170 + 3171 +When starting to homing, HW = 1, start to homing at a high speed in the reverse direction. After encountering the falling edge of HW, decelerate and reverse, run at a low speed in the forward direction, and stop at the first Z signal after encountering the rising edge of HW. 3172 + 3173 + 3174 + 3175 + 3176 + 3177 +(5) P01-40=5 3178 + 3179 +Mechanical homing: Motor Z signal 3180 + 3181 +Deceleration point: Home switch (HW) 3182 + 3183 +① The deceleration point signal is invalid when starting homing 3184 + 3185 +[[image:file:///C:\Users\Administrator\AppData\Local\Temp\ksohtml22584\wps10.png]] 3186 + 3187 +When it starts to homing, HW = 0, and it starts to homing at a reverse high speed. After encountering the rising edge of HW, it decelerates and reverses the direction, runs at a forward low speed, and stops at the first Z signal after encountering the falling edge of HW. 3188 + 3189 + 3190 +② The deceleration point signal is valid when starting homing 3191 + 3192 +[[image:file:///C:\Users\Administrator\AppData\Local\Temp\ksohtml22584\wps11.png]] 3193 + 3194 +When starting homing, HW=1, it will start homing directly at low speed, and the first Z signal after encountering the falling edge of HW will stop; 3195 + 3196 + 3197 + 3198 + 3199 + 3200 +(6) P01-40=6 3201 + 3202 +Mechanical homing: Motor Z signal 3203 + 3204 +Deceleration point: Home switch (HW) 3205 + 3206 +① The deceleration point signal is invalid when starting homing 3207 + 3208 +[[image:file:///C:\Users\Administrator\AppData\Local\Temp\ksohtml22584\wps12.png]] 3209 + 3210 +When starting to homing, HW=0, directly reverse low speed starts to homing, and the first Z signal stops after encountering the rising edge of HW; 3211 + 3212 + 3213 +② The deceleration point signal is valid when starting homing 3214 + 3215 +[[image:file:///C:\Users\Administrator\AppData\Local\Temp\ksohtml22584\wps13.png]] 3216 + 3217 +When starting to homing, HW = 1, start to homing at a forward high speed, after encountering the falling edge of HW, decelerate and reverse, run at a reverse low speed, and stop at the first Z signal after encountering the rising edge of HW. 3218 + 3219 + 3220 + 3221 + 3222 + 3223 +(7) P01-40=7 3224 + 3225 +Mechanical homing: Motor Z signal 3226 + 3227 +Deceleration point: Home switch (HW) 3228 + 3229 +① The deceleration point signal is invalid when starting homing, the forward limit switch is not encountered 3230 + 3231 +[[image:file:///C:\Users\Administrator\AppData\Local\Temp\ksohtml22584\wps14.png]] 3232 + 3233 +When it starts to homing, HW = 0, and it starts to homing at a forward high speed. If the limit switch is not encountered, after encountering the rising edge of HW, it decelerates and reverses the direction, and runs at a reverse low speed. The first Z signal after encountering the falling edge of HW stops. 3234 + 3235 + 3236 +When homing, the deceleration point signal is invalid and the forward limit switch is encountered 3237 + 3238 +[[image:file:///C:\Users\Administrator\AppData\Local\Temp\ksohtml22584\wps15.jpg]] 3239 + 3240 +When it starts to homing, HW = 0, and it starts to homing at a forward high speed. If it encounters a limit switch, it will automatically reverse and run at a reverse high speed. After encountering the rising edge of HW, it will slow down and continue to run at a reverse low speed. The first Z signal after the falling edge of HW will stop. 3241 + 3242 + 3243 +③ The deceleration point signal is valid when starting homing 3244 + 3245 +[[image:file:///C:\Users\Administrator\AppData\Local\Temp\ksohtml22584\wps16.png]] 3246 + 3247 +When starting homing, HW=1, then directly reverse the low speed to start homing, and stop the first Z signal after encountering the falling edge of HW; 3248 + 3249 + 3250 +(8) P01-40=8 3251 + 3252 +Mechanical homing: Motor Z signal 3253 + 3254 +Deceleration point: Home switch (HW) 3255 + 3256 +① The deceleration point signal is invalid when starting homing, the forward limit switch is not encountered 3257 + 3258 +[[image:file:///C:\Users\Administrator\AppData\Local\Temp\ksohtml22584\wps17.png]] 3259 + 3260 +When it starts to homing, HM-0 starts to homing at a forward high speed. If it does not encounter the limit switch, after encountering the rising edge of HW, slow down and reverse, and run at a reverse low speed. After encountering the falling edge of HW, reverse, run at a forward low speed, and stop at the first Z signal after encountering the rising edge of HW. 3261 + 3262 + 3263 +① The deceleration point signal is invalid when starting homing, the forward limit switch is encountered 3264 + 3265 +[[image:file:///C:\Users\Administrator\AppData\Local\Temp\ksohtml22584\wps18.png]] 3266 + 3267 +When it starts to homing, HW = 0, and it starts to homing at forward high speed. If it encounters a limit switch, it will automatically reverse and run at reverse high speed; After encountering the rising edge of HW, slow down and run at a reverse low speed; After encountering the falling edge of HW, reverse the direction, run at a forward low speed, and stop the first Z signal after encountering the rising edge of HW. 3268 + 3269 + 3270 +③ The deceleration point signal is valid when starting homing 3271 + 3272 +[[image:file:///C:\Users\Administrator\AppData\Local\Temp\ksohtml22584\wps19.png]] 3273 + 3274 +When starting to homing, HM-1 will directly reverse and start to return to zero at low speed. After encountering the falling edge of HW, it will reverse and run at forward low speed. The first Z signal after encountering the rising edge of HW will stop. 3275 + 3276 + 3277 + 3278 +(9) P01-40=9 3279 + 3280 +Mechanical homing: Motor Z signal 3281 + 3282 +Deceleration point: Home switch (HW) 3283 + 3284 +① The deceleration point signal is invalid when starting homing, the forward limit switch is not encountered 3285 + 3286 +[[image:file:///C:\Users\Administrator\AppData\Local\Temp\ksohtml22584\wps20.png]] 3287 + 3288 +When it starts to homing, HW=0, and it starts to homing at a forward high speed. If the limit switch is not encountered, after encountering the rising edge of HW, it decelerates and runs at a forward low speed; After encountering the falling edge of HW, reverse, run at a low speed in the reverse direction, and stop at the first Z signal after encountering the rising edge of HW. 3289 + 3290 + 3291 +① The deceleration point signal is invalid when starting homing, the forward limit switch is encountered 3292 + 3293 +[[image:file:///C:\Users\Administrator\AppData\Local\Temp\ksohtml22584\wps21.png]] 3294 + 3295 +When it starts to homing, HW = 0, and it starts to homing at a forward high speed. If it encounters a limit switch, it will automatically reverse and run at a reverse high speed. After encountering a rising edge of HW, it will slow down and reverse to resume forward operation. Running at a forward low speed, after encountering a falling edge of HW, it will reverse. During reverse low speed operation, the first Z signal after encountering a rising edge of HW will stop. 3296 + 3297 +③ The deceleration point signal is valid when starting homing 3298 + 3299 +[[image:file:///C:\Users\Administrator\AppData\Local\Temp\ksohtml22584\wps22.png]] 3300 + 3301 +When starting homing, HW=1 starts homing directly at forward low speed. After encountering the falling edge of HW, the first Z signal after encountering the rising edge of HW stops in reverse and reverse low speed operation; 3302 + 3303 + 3304 +(10) P01-40=10 3305 + 3306 +Mechanical homing: Motor Z signal 3307 + 3308 +Deceleration point: Home switch (HW) 3309 + 3310 +① The deceleration point signal is invalid when starting homing, the forward limit switch is not encountered 3311 + 3312 +[[image:file:///C:\Users\Administrator\AppData\Local\Temp\ksohtml22584\wps23.png]] 3313 + 3314 +When it starts to homing, HW = 0, and it starts to homing at a forward high speed. If the limit switch is not encountered, after encountering the rising edge of HW, slow down and run at a forward low speed. After encountering the falling edge of HW, continue to run at a forward low speed, and then the first Z signal encountered stops. 3315 + 3316 +When homing, the deceleration point signal is invalid and the forward limit switch is encountered 3317 + 3318 +[[image:file:///C:\Users\Administrator\AppData\Local\Temp\ksohtml22584\wps24.jpg]] 3319 + 3320 +When it starts to homing, HW = 0, and it starts to homing at a forward high speed. If it encounters a limit switch, it will automatically reverse and run at a reverse high speed. After encountering the rising edge of HW, it will slow down and reverse to resume forward operation. The first Z signal after the low speed encounters the falling edge of HW will stop. 3321 + 3322 + 3323 +③ The deceleration point signal is valid when starting homing 3324 + 3325 +[[image:file:///C:\Users\Administrator\AppData\Local\Temp\ksohtml22584\wps25.png]] 3326 + 3327 +When starting homing, HW=1, it will start homing directly at low speed, and the first Z signal after encountering the falling edge of HW will stop; 3328 + 3329 + 3330 +(11) P01-40=11 3331 + 3332 +Mechanical homing: Motor Z signal 3333 + 3334 +Deceleration point: Home switch (HW) 3335 + 3336 +① The deceleration point signal is invalid when starting homing, the reverse limit switch is not encountered 3337 + 3338 +[[image:file:///C:\Users\Administrator\AppData\Local\Temp\ksohtml22584\wps26.png]] 3339 + 3340 +When it starts to homing, HW=0, and it starts to homing at a reverse high speed. If the limit switch is not encountered, after encountering the rising edge of HW, it decelerates and reverses the direction, runs at a forward low speed, and stops at the first Z signal after encountering the falling edge of HW. 3341 + 3342 + 3343 +① The deceleration point signal is invalid when starting homing, the reverse limit switch is encountered 3344 + 3345 +[[image:file:///C:\Users\Administrator\AppData\Local\Temp\ksohtml22584\wps27.png]] 3346 + 3347 +When it starts to homing, HW=0, and it starts to homing at a reverse high speed. If it encounters a limit switch, it will automatically reverse and run at a forward high speed. After encountering a rising edge of HW, slow down and continue to run at a forward low speed. When encountering a falling edge of HW, the first Z signal after the edge stops. 3348 + 3349 +③ The deceleration point signal is valid when starting homing 3350 + 3351 +[[image:file:///C:\Users\Administrator\AppData\Local\Temp\ksohtml22584\wps28.png]] 3352 + 3353 +When starting homing, HW=1, it will start homing directly at low speed, and the first Z signal after encountering the falling edge of HW will stop; 3354 + 3355 + 3356 +(12) P01-40=12 3357 + 3358 +Mechanical homing: Motor Z signal 3359 + 3360 +Deceleration point: Home switch (HW) 3361 + 3362 +① The deceleration point signal is invalid when starting homing, the reverse limit switch is not encountered 3363 + 3364 +[[image:file:///C:\Users\Administrator\AppData\Local\Temp\ksohtml22584\wps29.png]] 3365 + 3366 +When it starts to homing, HW = 0, it starts to homing at a reverse high speed, and does not encounter a limit switch. After encountering the rising edge of HW, it decelerates and reverses, and runs at a forward low speed. After encountering the falling edge of HW, it reverses and runs at a reverse low speed, and stops at the first Z signal after encountering the rising edge of HW. 3367 + 3368 + 3369 + 3370 +① The deceleration point signal is invalid when starting homing, the reverse limit switch is encountered 3371 + 3372 +[[image:file:///C:\Users\Administrator\AppData\Local\Temp\ksohtml22584\wps30.png]] 3373 + 3374 +When it starts to homing, HW=0, it starts to homing at a reverse high speed, encounters a limit switch, automatically reverses, runs at a forward high speed, encounters a rising edge of HW, decelerates, runs at a forward low speed, encounters a falling edge of HW, reverses, runs at a reverse low speed, and stops at the first Z signal after encountering a rising edge of HW. 3375 + 3376 + 3377 +③ The deceleration point signal is valid when starting homing 3378 + 3379 +[[image:file:///C:\Users\Administrator\AppData\Local\Temp\ksohtml22584\wps31.png]] 3380 + 3381 +When starting to homing, HW = 1, it will directly start to homing at a forward low speed. After encountering the falling edge of HW, it will reverse and run at a reverse low speed. The first Z signal after encountering the rising edge of HW will stop. 3382 + 3383 +(13) P01-40=13 3384 + 3385 +Mechanical homing: Motor Z signal 3386 + 3387 +Deceleration point: Home switch (HW) 3388 + 3389 +① The deceleration point signal is invalid when starting homing, the reverse limit switch is not encountered 3390 + 3391 +[[image:file:///C:\Users\Administrator\AppData\Local\Temp\ksohtml22584\wps32.png]] 3392 + 3393 +When it starts to homing, HW=0, and it starts to homing at a reverse high speed. If it does not encounter the limit switch, after encountering the rising edge of HW, slow down and run at a reverse low speed. After encountering the falling edge of HW, reverse and run at a forward low speed, and stop at the first Z signal after encountering the rising edge of HW. 3394 + 3395 + 3396 +① The deceleration point signal is invalid when starting homing, the reverse limit switch is encountered 3397 + 3398 +[[image:file:///C:\Users\Administrator\AppData\Local\Temp\ksohtml22584\wps33.png]] 3399 + 3400 +When it starts to homing, HW=0, it starts to homing at reverse high speed, encounters the limit switch, automatically reverses, runs at forward high speed, after encountering the rising edge of HW, decelerates and runs in reverse low speed, and encounters the falling edge of HW when running at reverse low speed, the first Z signal after encountering the rising edge of HW stops. 3401 + 3402 +③ The deceleration point signal is valid when starting homing 3403 + 3404 +[[image:file:///C:\Users\Administrator\AppData\Local\Temp\ksohtml22584\wps34.png]] 3405 + 3406 +When starting homing, HW=1 starts homing directly at reverse low speed. After encountering the falling edge of HW, the first Z signal after encountering the rising edge of HW stops in reverse and forward low speed operation; 3407 + 3408 + 3409 +(14) P01-40=14 3410 + 3411 +Mechanical homing: Motor Z signal 3412 + 3413 +Deceleration point: Home switch (HW) 3414 + 3415 +① The deceleration point signal is invalid when starting homing, the reverse limit switch is not encountered 3416 + 3417 +[[image:file:///C:\Users\Administrator\AppData\Local\Temp\ksohtml22584\wps35.png]] 3418 + 3419 +When it starts to homing, HW=0, it starts to homing at reverse high speed, and does not encounter the limit switch. After encountering the rising edge of HW, it decelerates and runs at reverse low speed. After encountering the falling edge of HW, it continues to run at reverse low speed, and then the first Z signal encountered stops. 3420 + 3421 + 3422 +① The deceleration point signal is invalid when starting homing, the reverse limit switch is encountered 3423 + 3424 +[[image:file:///C:\Users\Administrator\AppData\Local\Temp\ksohtml22584\wps36.png]] 3425 + 3426 +When it starts to homing, HW = 0, it starts to homing at a reverse high speed, encounters a limit switch, automatically reverses, runs at a forward high speed, encounters a rising edge of HW, decelerates and runs in a reverse direction, and stops the first Z signal after encountering a falling edge of HW at a reverse low speed. 3427 + 3428 + 3429 +③ The deceleration point signal is valid when starting homing 3430 + 3431 +[[image:file:///C:\Users\Administrator\AppData\Local\Temp\ksohtml22584\wps37.png]] 3432 + 3433 +When starting homing, HW=1, then directly reverse the low speed to start homing, and stop the first Z signal after encountering the falling edge of HW; 3434 + 3435 + 3436 +(15) P01-40=17 3437 + 3438 +Mechanical homing: Negative overrun switch (NOT) 3439 + 3440 +Deceleration point: Negative overrun switch (NOT) 3441 + 3442 +① The deceleration point signal is invalid when starting homing 3443 + 3444 +[[image:file:///C:\Users\Administrator\AppData\Local\Temp\ksohtml22584\wps38.png]] 3445 + 3446 +When it starts to homing, NOT = 0, it starts to homing at a high speed in the reverse direction. After encountering the rising edge of NOT, it decelerates and reverses the direction, runs at a low speed in the forward direction, and stops after encountering the falling edge of NOT. 3447 + 3448 + 3449 +② The deceleration point signal is valid when starting homing 3450 + 3451 +[[image:file:///C:\Users\Administrator\AppData\Local\Temp\ksohtml22584\wps39.png]] 3452 + 3453 +When starting homing, NOT=1, start homing directly at low speed, and stop after encountering the falling edge of NOT. 3454 + 3455 + 3456 +(16) P01-40=18 3457 + 3458 +Mechanical homing: Positive overrun switch (POT) 3459 + 3460 +Deceleration point: Positive overrun switch (POT) 3461 + 3462 +① The deceleration point signal is invalid when starting homing 3463 + 3464 +[[image:file:///C:\Users\Administrator\AppData\Local\Temp\ksohtml22584\wps40.png]] 3465 + 3466 +When it starts to return to zero, POT=0, it starts to homing at a forward high speed, after encountering the rising edge of POT, it decelerates and reverses, runs at a reverse low speed, and stops after encountering the falling edge of POT. 3467 + 3468 + 3469 +② The deceleration point signal is valid when starting homing 3470 + 3471 +[[image:file:///C:\Users\Administrator\AppData\Local\Temp\ksohtml22584\wps41.png]] 3472 + 3473 +When starting homing, POT=1, start homing at low speed in reverse directly, and stop when encountering POT falling edge; 3474 + 3475 + 3476 + 3477 +(17) P01-40=19 3478 + 3479 +Mechanical homing: Home switch (HW) 3480 + 3481 +Deceleration point: Home switch (HW) 3482 + 3483 +① The deceleration point signal is invalid when starting homing 3484 + 3485 +[[image:file:///C:\Users\Administrator\AppData\Local\Temp\ksohtml22584\wps42.png]] 3486 + 3487 +When it starts to homing, HW=0, and it starts to homing at a forward high speed. After encountering the rising edge of HW, it decelerates and reverses the direction, runs at a reverse low speed, and stops when encountering the falling edge of HW. 3488 + 3489 + 3490 +② The deceleration point signal is valid when starting homing 3491 + 3492 +[[image:file:///C:\Users\Administrator\AppData\Local\Temp\ksohtml22584\wps43.png]] 3493 + 3494 +When starting homing, HW=1, start homing at low speed in reverse directly, and stop when encountering HW falling edge; 3495 + 3496 + 3497 +(18) P01-40=20 3498 + 3499 +Mechanical homing: Home switch (HW) 3500 + 3501 +Deceleration point: Home switch (HW) 3502 + 3503 +① The deceleration point signal is invalid when starting homing 3504 + 3505 +[[image:file:///C:\Users\Administrator\AppData\Local\Temp\ksohtml22584\wps44.png]] 3506 + 3507 +When starting to homing, HW=0, directly start to homing at low speed, and stop after encountering the rising edge of HW; 3508 + 3509 + 3510 +② The deceleration point signal is valid when starting homing 3511 + 3512 +[[image:file:///C:\Users\Administrator\AppData\Local\Temp\ksohtml22584\wps45.png]] 3513 + 3514 +When starting to homing, HW = 1, start to homing at a high speed in the reverse direction. After encountering the falling edge of HW, slow down and reverse the direction, run at a low speed in the forward direction, and stop when encountering the rising edge of HW. 3515 + 3516 + 3517 +(19) P01-40=21 3518 + 3519 +Mechanical homing: Home switch (HW) 3520 + 3521 +Deceleration point: Home switch (HW) 3522 + 3523 +① The deceleration point signal is invalid when starting homing 3524 + 3525 +[[image:file:///C:\Users\Administrator\AppData\Local\Temp\ksohtml22584\wps46.png]] 3526 + 3527 +When it starts to homing, HW=0, it starts to homing at a reverse high speed. After encountering the rising edge of HW, it decelerates and reverses the direction, runs at a forward low speed, and stops when encountering the falling edge of HW. 3528 + 3529 + 3530 +② The deceleration point signal is valid when starting homing 3531 + 3532 +[[image:file:///C:\Users\Administrator\AppData\Local\Temp\ksohtml22584\wps47.png]] 3533 + 3534 +When starting back to zero, HW=1, it will start homing directly at low speed, and stop after encountering the falling edge of HW; 3535 + 3536 + 3537 +(20) P01-40=22 3538 + 3539 +Mechanical homing: Home switch (HW) 3540 + 3541 +Deceleration point: Home switch (HW) 3542 + 3543 +① The deceleration point signal is invalid when starting homing 3544 + 3545 +[[image:file:///C:\Users\Administrator\AppData\Local\Temp\ksohtml22584\wps48.png]] 3546 + 3547 +When starting to homing, HW=0, directly reverse low speed starts to homing, and stops when encountering HW rising edge; 3548 + 3549 + 3550 +Deceleration point signal is valid when homing start 3551 + 3552 +[[image:file:///C:\Users\Administrator\AppData\Local\Temp\ksohtml22584\wps49.jpg]] 3553 + 3554 +When starting to homing, HW=1, start to homing at a forward high speed, after encountering the falling edge of HW, slow down and reverse, run at a reverse low speed, and stop when encountering the rising edge of HW. 3555 + 3556 + 3557 +(21) P01-40=23 3558 + 3559 +Mechanical homing: Home switch (HW) 3560 + 3561 +Deceleration point: Home switch (HW) 3562 + 3563 +① The deceleration point signal is invalid when starting homing, the forward limit switch is not encountered 3564 + 3565 +[[image:file:///C:\Users\Administrator\AppData\Local\Temp\ksohtml22584\wps50.png]] 3566 + 3567 +When it starts to homing, HW = 0, it starts to homing at a forward high speed, and does not encounter a limit switch. After encountering the rising edge of HW, it decelerates and reverses, runs at a reverse low speed, and stops when encountering the falling edge of HW. 3568 + 3569 + 3570 +① The deceleration point signal is invalid when starting homing, the forward limit switch is encountered 3571 + 3572 +[[image:file:///C:\Users\Administrator\AppData\Local\Temp\ksohtml22584\wps51.png]] 3573 + 3574 +When you start homing, HW = 0, start homing at a forward high speed. When encountering the limit switch, it will automatically reverse and run at a reverse high speed. After encountering the rising edge of HW, slow down, continue to run at reverse low speed, and stop when encountering the HW falling edge. 3575 + 3576 + 3577 + 3578 +③ The deceleration point signal is valid when starting homing 3579 + 3580 +[[image:file:///C:\Users\Administrator\AppData\Local\Temp\ksohtml22584\wps52.png]] 3581 + 3582 +When it starts to homing, HW=1, it starts to homing at a reverse low speed, and stops when it encounters the falling edge of HW. 3583 + 3584 + 3585 +(22) P01-40=24 3586 + 3587 +Mechanical homing: Home switch (HW) 3588 + 3589 +Deceleration point: Home switch (HW) 3590 + 3591 +① The deceleration point signal is invalid when starting homing, the forward limit switch is not encountered 3592 + 3593 +[[image:file:///C:\Users\Administrator\AppData\Local\Temp\ksohtml22584\wps53.png]] 3594 + 3595 +When it starts to homing, HW = 0, it starts to homing at a forward high speed, and does not encounter a limit switch. After encountering the rising edge of HW, it decelerates and reverses, and runs at a reverse low speed. After encountering the falling edge of HW, it reverses and runs at a forward low speed, and stops when encountering the rising edge of HW. 3596 + 3597 + 3598 +① The deceleration point signal is invalid when starting homing, the forward limit switch is encountered 3599 + 3600 +[[image:file:///C:\Users\Administrator\AppData\Local\Temp\ksohtml22584\wps54.png]] 3601 + 3602 +When it starts to homing, HW = 0, it starts to homing at forward high speed, encounters the limit switch, automatically reverses, runs at reverse high speed, encounters the rising edge of HW, decelerates and runs at reverse low speed, encounters the falling edge of HW, reverses, runs at forward low speed, and stops when encountering the rising edge of HW. 3603 + 3604 + 3605 +③ The deceleration point signal is valid when starting homing 3606 + 3607 +[[image:file:///C:\Users\Administrator\AppData\Local\Temp\ksohtml22584\wps55.png]] 3608 + 3609 +When starting with homing, HW = 1, it will directly reverse the low speed and start to homing. After encountering the falling edge of HW, it will reverse the direction and run at a forward low speed, and stop when encountering the rising edge of HW. 3610 + 3611 + 3612 +(23) P01-40=25 3613 + 3614 +Mechanical homing: Home switch (HW) 3615 + 3616 +Deceleration point: Home switch (HW) 3617 + 3618 +① The deceleration point signal is invalid when starting homing, the forward limit switch is not encountered 3619 + 3620 +[[image:file:///C:\Users\Administrator\AppData\Local\Temp\ksohtml22584\wps56.png]] 3621 + 3622 +When it starts to homing, HW=0, it starts to homing at a forward high speed, and does not encounter a limit switch. After encountering the rising edge of HW, it decelerates and runs at a forward low speed. After encountering the falling edge of HW, it reverses and runs at a reverse low speed, and stops when encountering the rising edge of HW. 3623 + 3624 + 3625 +① The deceleration point signal is invalid when starting homing, the forward limit switch is encountered 3626 + 3627 +[[image:file:///C:\Users\Administrator\AppData\Local\Temp\ksohtml22584\wps57.png]] 3628 + 3629 +When it starts to homing, HW=0, it starts to homing at forward high speed, encounters the limit switch, automatically reverses, and runs at reverse high speed. After encountering the rising edge of HW, decelerate and reverse to resume forward operation. After encountering the falling edge of HW at forward low speed, reverse. When running at reverse low speed, stop when encountering the rising edge of HW. 3630 + 3631 + 3632 +③ The deceleration point signal is valid when starting homing 3633 + 3634 +[[image:file:///C:\Users\Administrator\AppData\Local\Temp\ksohtml22584\wps58.png]] 3635 + 3636 +When starting homing, when HW=1, it starts to homing directly at low speed in the forward direction. After encountering the falling edge of HW, it stops at the rising edge of HW in the reverse low speed operation 3637 + 3638 + 3639 +(24) P01-40=26 3640 + 3641 +Mechanical homing: Home switch (HW) 3642 + 3643 +Deceleration point: Home switch (HW) 3644 + 3645 +① The deceleration point signal is invalid when starting homing, the forward limit switch is not encountered 3646 + 3647 +[[image:file:///C:\Users\Administrator\AppData\Local\Temp\ksohtml22584\wps59.png]] 3648 + 3649 +When it starts to homing, HW=0, it starts to homing at a forward high speed, and does not encounter a limit switch. After encountering the rising edge of HW, it decelerates, runs at a forward low speed, and stops when encountering the falling edge of HW. 3650 + 3651 + 3652 +① The deceleration point signal is invalid when starting homing, the forward limit switch is encountered 3653 + 3654 +[[image:file:///C:\Users\Administrator\AppData\Local\Temp\ksohtml22584\wps60.png]] 3655 + 3656 +When it starts to homing, HW=0, it starts to homing at forward high speed, encounters the limit switch, automatically reverses, and runs at reverse high speed. After encountering the rising edge of HW, decelerates and reverses to resume forward operation, and stops when encountering the falling edge of HW at forward low speed. 3657 + 3658 + 3659 +③ The deceleration point signal is valid when starting homing 3660 + 3661 +[[image:file:///C:\Users\Administrator\AppData\Local\Temp\ksohtml22584\wps61.png]] 3662 + 3663 +When starting homing, HW=1, it will start homing directly at low speed, and stop when encountering HW falling edge; 3664 + 3665 + 3666 +(25) P01-40=27 3667 + 3668 +Mechanical homing: Home switch (HW) 3669 + 3670 +Deceleration point: Home switch (HW) 3671 + 3672 +① The deceleration point signal is invalid when starting homing, the reverse limit switch is not encountered 3673 + 3674 +[[image:file:///C:\Users\Administrator\AppData\Local\Temp\ksohtml22584\wps62.png]] 3675 + 3676 +When it starts to homing, HW=0, it starts to homing at a reverse high speed, and does not encounter a limit switch. After encountering the rising edge of HW, it decelerates and reverses the direction, runs at a forward low speed, and stops when encountering the falling edge of HW. 3677 + 3678 + 3679 +① The deceleration point signal is invalid when starting homing, the reverse limit switch is encountered 3680 + 3681 +[[image:file:///C:\Users\Administrator\AppData\Local\Temp\ksohtml22584\wps63.png]] 3682 + 3683 +When it starts to homing, HW=0, it starts to homing at a reverse high speed. When it encounters a limit switch, it automatically reverses and runs at a forward high speed. When it encounters a rising edge of HW, it decelerates and continues to run at a forward low speed. When it encounters a falling edge of HW, it stops. 3684 + 3685 + 3686 +③ The deceleration point signal is valid when starting homing 3687 + 3688 +[[image:file:///C:\Users\Administrator\AppData\Local\Temp\ksohtml22584\wps64.png]] 3689 + 3690 +When starting homing, HW=1, it will start homing directly at low speed, and stop when encountering HW falling edge; 3691 + 3692 + 3693 +(26) P01-40=28 3694 + 3695 +Mechanical homing: Home switch (HW) 3696 + 3697 +Deceleration point: Home switch (HW) 3698 + 3699 +① The deceleration point signal is invalid when starting homing, the reverse limit switch is not encountered 3700 + 3701 +[[image:file:///C:\Users\Administrator\AppData\Local\Temp\ksohtml22584\wps65.png]] 3702 + 3703 +When it starts to homing, HW=0, it starts to homing at a reverse high speed, and does not encounter a limit switch. After encountering the rising edge of HW, it decelerates and reverses, and runs at a forward low speed. After encountering the falling edge of HW, it reverses and runs at a reverse low speed, and stops when encountering the rising edge of HW. 3704 + 3705 + 3706 +① The deceleration point signal is invalid when starting homing, the reverse limit switch is encountered 3707 + 3708 +[[image:file:///C:\Users\Administrator\AppData\Local\Temp\ksohtml22584\wps66.png]] 3709 + 3710 +When it starts to homing, HW=0, it starts to homing at a reverse high speed. When encountering a limit switch, it automatically reverses and runs at a forward high speed. When encountering a rising edge of HW, it decelerates and runs at a forward low speed. When encountering a falling edge of HW, it reverses and runs at a reverse low speed. When encountering a rising edge of HW, it stops. 3711 + 3712 + 3713 +③ The deceleration point signal is valid when starting homing 3714 + 3715 +[[image:file:///C:\Users\Administrator\AppData\Local\Temp\ksohtml22584\wps67.png]] 3716 + 3717 +When starting with homing, HW = 1, it will directly start to homing at a forward low speed. After encountering the falling edge of HW, it will reverse and run at a reverse low speed. When encountering the rising edge of HW, it will stop. 3718 + 3719 + 3720 +(27) P01-40=29 3721 + 3722 +Mechanical homing: Home switch (HW) 3723 + 3724 +Deceleration point: Home switch (HW) 3725 + 3726 +① The deceleration point signal is invalid when starting homing, the reverse limit switch is not encountered 3727 + 3728 +[[image:file:///C:\Users\Administrator\AppData\Local\Temp\ksohtml22584\wps68.png]] 3729 + 3730 +When it starts to homing, HW = 0, it starts to homing at a reverse high speed, and does not encounter a limit switch. After encountering the rising edge of HW, it decelerates and runs at a reverse low speed. After encountering the falling edge of HW, it reverses and runs at a forward low speed, and stops when encountering the rising edge of HW. 3731 + 3732 + 3733 +① The deceleration point signal is invalid when starting homing, the reverse limit switch is encountered 3734 + 3735 +[[image:file:///C:\Users\Administrator\AppData\Local\Temp\ksohtml22584\wps69.png]] 3736 + 3737 +When it starts to homing, HW=0, it starts to homing at a reverse high speed. When it encounters a limit switch, it automatically reverses and runs at a forward high speed. After encountering a rising edge of HW, it decelerates and runs in a reverse low speed. After encountering a falling edge of HW, it reverses. When running at a forward low speed, it stops when it encounters a rising edge of HW. 3738 + 3739 +③ The deceleration point signal is valid when starting homing 3740 + 3741 +[[image:file:///C:\Users\Administrator\AppData\Local\Temp\ksohtml22584\wps70.png]] 3742 + 3743 +When starting homing, when HW=1, it starts to homing directly at low speed in reverse direction. After encountering the falling edge of HW, it stops when running at low speed in reverse direction and forward direction and encountering the rising edge of HW 3744 + 3745 + 3746 +(28) P01-40=30 3747 + 3748 +Mechanical homing: Home switch (HW) 3749 + 3750 +Deceleration point: Home switch (HW) 3751 + 3752 +① The deceleration point signal is invalid when starting homing, the reverse limit switch is not encountered 3753 + 3754 +[[image:file:///C:\Users\Administrator\AppData\Local\Temp\ksohtml22584\wps71.png]] 3755 + 3756 +When it starts to homing, HW=0, it starts to homing at reverse high speed, and does not encounter the limit switch. After encountering the rising edge of HW, it decelerates, runs at reverse low speed, and stops when encountering the falling edge of HW. 3757 + 3758 + 3759 +① The deceleration point signal is invalid when starting homing, the reverse limit switch is encountered 3760 + 3761 +[[image:file:///C:\Users\Administrator\AppData\Local\Temp\ksohtml22584\wps72.png]] 3762 + 3763 +When it starts to homing, HW=0, it starts to homing at a reverse high speed. When it encounters a limit switch, it automatically reverses and runs at a forward high speed. When it encounters a rising edge of HW, it decelerates and runs in a reverse low speed. When it encounters a falling edge of HW, it stops. 3764 + 3765 + 3766 +③ The deceleration point signal is valid when starting homing 3767 + 3768 +[[image:file:///C:\Users\Administrator\AppData\Local\Temp\ksohtml22584\wps73.png]] 3769 + 3770 +When starting homing, HW=1, start homing at low speed in reverse directly, and stop when encountering HW falling edge; 3771 + 3772 + 3773 +(29) P01-40=33 and P01-40=34 3774 + 3775 +Mechanical homing: Z signal. 3776 + 3777 +Deceleration point: None 3778 + 3779 +Homing mode 33: Reverse low speed operation, stop the first Z signal encountered 3780 + 3781 +Homing mode 34: running at low speed in forward direction, stopping the first Z signal encountered 3782 + 3783 +[[image:file:///C:\Users\Administrator\AppData\Local\Temp\ksohtml22584\wps74.png]] 3784 + 3785 + 3786 +(30) P01-40=35 3787 + 3788 +Homing mode 35, taking the current position as the mechanical homing, after triggering the homing (P01-39: 0x00→0x01/0x00 → 0x02); 3789 + 3790 +After the homing is completed, according to the set value of P10-08 (homing bias compensation), P10-06 (encoder multi-turn reset operation) is executed. 3791 + 3792 + 3793 +