Changes for page 06 Operation

Last modified by Iris on 2025/08/08 14:40

From version 90.1
edited by Mora Zhou
on 2025/04/29 10:05
Change comment: There is no comment for this version
To version 99.1
edited by Mora Zhou
on 2025/04/29 11:01
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -1910,10 +1910,13 @@
1910 1910  )))|0|0 to 3|(((
1911 1911  Set the zero-speed clamp function. In speed mode:
1912 1912  
1913 -* 0: Force the speed to 0;
1914 -* 1: Force the speed to 0, and keep the position locked when the actual speed is less than P01-22
1915 -* 2: When speed instruction is less than P01-22, force the speed to 0 and keep the position locked
1916 -* 3: Invalid, ignore zero-speed clamp input
1913 +0: Force the speed to 0;
1914 +
1915 +1: Force the speed to 0, and keep the position locked when the actual speed is less than P01-22
1916 +
1917 +2: When speed instruction is less than P01-22, force the speed to 0 and keep the position locked
1918 +
1919 +3: Invalid, ignore zero-speed clamp input
1917 1917  )))|-
1918 1918  |=P01-22|(((
1919 1919  Zero-speed clamp speed threshold
... ... @@ -1921,7 +1921,7 @@
1921 1921  Operation setting
1922 1922  )))|(((
1923 1923  Effective immediately
1924 -)))|20|0 to 1000|Set the speed threshold of zero-speed clamp function|rpm
1927 +)))|20|0 to 6000|Set the speed threshold of zero-speed clamp function|rpm
1925 1925  
1926 1926  Table 6-33 Zero-speed clamp related parameters
1927 1927  
... ... @@ -1966,7 +1966,7 @@
1966 1966  
1967 1967  |=(% scope="row" %)**DO function code**|=(% style="width: 247px;" %)**Function name**|=(% style="width: 695px;" %)**Function**
1968 1968  |=132|(% style="width:247px" %)(((
1969 -T-COIN rotation detection
1972 +TGON rotation detection
1970 1970  )))|(% style="width:695px" %)(((
1971 1971  Valid: when the absolute value of motor speed after filtering is greater than or equal to the set value of function code P05-16
1972 1972  
... ... @@ -2034,7 +2034,7 @@
2034 2034  
2035 2035  |=(% scope="row" %)**DO Function code**|=(% style="width: 262px;" %)**Function name**|=(% style="width: 684px;" %)**Function**
2036 2036  |=136|(% style="width:262px" %)(((
2037 -U-COIN consistent speed
2040 +V-COIN consistent speed
2038 2038  )))|(% style="width:684px" %)The output signal indicates that the absolute deviation of the actual speed of servo motor and the speed instruction meets the P05-17 set value
2039 2039  
2040 2040  Table 6-39 DO speed consistent function code
... ... @@ -2218,8 +2218,9 @@
2218 2218  )))|(((
2219 2219  Effective immediately
2220 2220  )))|0|0 to 1|(((
2221 -* 0: internal value
2222 -* 1: AI_1 analog input (not supported by VD2F and VD2L)
2224 +0: internal value
2225 +
2226 +1: AI_1 analog input (not supported by VD2F and VD2L)
2223 2223  )))|-
2224 2224  
2225 2225  * Torque limit source is internal torque instruction (P01-14=0)
... ... @@ -2296,7 +2296,7 @@
2296 2296  Operation setting
2297 2297  )))|(((
2298 2298  Effective immediately
2299 -)))|3000|0 to 5000|(((
2303 +)))|3000|0 to 6000|(((
2300 2300  Forward torque
2301 2301  
2302 2302  limit in torque mode
... ... @@ -2309,7 +2309,7 @@
2309 2309  Operation setting
2310 2310  )))|(((
2311 2311  Effective immediately
2312 -)))|3000|0 to 5000|(((
2316 +)))|3000|0 to 6000|(((
2313 2313  Reverse torque
2314 2314  
2315 2315  limit in torque mode
... ... @@ -2394,13 +2394,18 @@
2394 2394  )))|(((
2395 2395  Shutdown setting
2396 2396  )))|1|(% style="width:90px" %)1 to 6|(% style="width:273px" %)(((
2397 -* 1: Position control
2398 -* 2: Speed control
2399 -* 3: Torque control
2400 -* 4: Position/speed mixed control
2401 -* 5: Position/torque mixed control
2402 -* 6: Speed/torque mixed control
2401 +1: Position control
2403 2403  
2403 +2: Speed control
2404 +
2405 +3: Torque control
2406 +
2407 +4: Position/speed mixed control
2408 +
2409 +5: Position/torque mixed control
2410 +
2411 +6: Speed/torque mixed control
2412 +
2404 2404  **VD2L drive P0-01 setting range: 1-3, not support mixed mode**
2405 2405  )))|-
2406 2406  
... ... @@ -2542,8 +2542,9 @@
2542 2542  **time**
2543 2543  )))|=**Default value**|=**Range**|=**Definition**|=**Unit**
2544 2544  |=P00-30|Shield multi-turn absolute encoder battery fault|Operation setting|Power on again|0|0 to 1|(((
2545 -* 0:Detect multi-turn absolute encoder battery under voltage, and battery low voltage fault
2546 -* 1: (Not recommended) Shield multi-turn absolute motor battery failure alarm. Multi-turn absolute application may cause mechanical fault, only multi-turn absolute encoder motors is used as single-turn absolute
2554 +0:Detect multi-turn absolute encoder battery under voltage, and battery low voltage fault
2555 +
2556 +1: (Not recommended) Shield multi-turn absolute motor battery failure alarm. Multi-turn absolute application may cause mechanical fault, only multi-turn absolute encoder motors is used as single-turn absolute
2547 2547  )))|-
2548 2548  
2549 2549  This function is permitted when a multi-turn absolute encoder motor is used as a single-turn absolute and when it is confirmed that no mechanical failure will occur.
... ... @@ -2688,8 +2688,9 @@
2688 2688  
2689 2689  VDI_1 input level:
2690 2690  
2691 -* 0: low level
2692 -* 1: high level
2701 +0: Low level
2702 +
2703 +1: High level
2693 2693  )))|-
2694 2694  |=P13-2|Virtual VDI_2 input value|Operation setting|Effective immediately|0|0 to 1|(((
2695 2695  When P06-07 is set to 1, DI_2 channel logic is control by this function code.
... ... @@ -2696,8 +2696,9 @@
2696 2696  
2697 2697  VDI_2 input level:
2698 2698  
2699 -* 0: low level
2700 -* 1: high level
2710 +0: Low level
2711 +
2712 +1: High level
2701 2701  )))|-
2702 2702  |=P13-3|Virtual VDI_3 input value|Operation setting|Effective immediately|0|0 to 1|(((
2703 2703  When P06-10 is set to 1, DI_3 channel logic is control by this function code.
... ... @@ -2704,8 +2704,9 @@
2704 2704  
2705 2705  VDI_3 input level:
2706 2706  
2707 -* 0: low level
2708 -* 1: high level
2719 +0: Low level
2720 +
2721 +1: High level
2709 2709  )))|-
2710 2710  |=P13-4|Virtual VDI_4 input value|Operation setting|Effective immediately|0|0 to 1|(((
2711 2711  When P06-13 is set to 1, DI_4 channel logic is control by this function code.
... ... @@ -2712,40 +2712,53 @@
2712 2712  
2713 2713  VDI_4 input level:
2714 2714  
2715 -* 0: low level
2716 -* 1: high level
2728 +0: Low level
2729 +
2730 +1: High level
2717 2717  )))|-
2718 -|=P13-05☆|Virtual VDI_5 input value|Operation setting|Effective immediately|0|0 to 1|(((
2732 +|=P13-05(((
2733 +★
2734 +)))|Virtual VDI_5 input value|Operation setting|Effective immediately|0|0 to 1|(((
2719 2719  When P06-16 is set to 1, DI_5 channel logic is control by this function code.
2720 2720  
2721 2721  VDI_5 input level:
2722 2722  
2723 -* 0: low level
2724 -* 1: high level
2739 +0: Low level
2740 +
2741 +1: High level
2725 2725  )))|-
2726 -|=P13-06☆|Virtual VDI_6 input value|Operation setting|Effective immediately|0|0 to 1|(((
2743 +|=P13-06(((
2744 +★
2745 +)))|Virtual VDI_6 input value|Operation setting|Effective immediately|0|0 to 1|(((
2727 2727  When P06-19 is set to 1, DI_6 channel logic is control by this function code.
2728 2728  
2729 2729  VDI_6 input level:
2730 2730  
2731 -* 0: low level
2732 -* 1: high level
2750 +0: Low level
2751 +
2752 +1: High level
2733 2733  )))|-
2734 -|=P13-07☆|Virtual VDI_7 input value|Operation setting|Effective immediately|0|0 to 1|(((
2754 +|=P13-07(((
2755 +★
2756 +)))|Virtual VDI_7 input value|Operation setting|Effective immediately|0|0 to 1|(((
2735 2735  When P06-22 is set to 1, DI_7 channel logic is control by this function code.
2736 2736  
2737 2737  VDI_7 input level:
2738 2738  
2739 -* 0: low level
2740 -* 1: high level
2761 +0: Low level
2762 +
2763 +1: High level
2741 2741  )))|-
2742 -|=P13-08☆|Virtual VDI_8 input value|Operation setting|Effective immediately|0|0 to 1|(((
2765 +|=P13-08(((
2766 +★
2767 +)))|Virtual VDI_8 input value|Operation setting|Effective immediately|0|0 to 1|(((
2743 2743  When P06-25 is set to 1, DI_8 channel logic is control by this function code.
2744 2744  
2745 2745  VDI_8 input level:
2746 2746  
2747 -* 0: low level
2748 -* 1: high level
2772 +0: Low level
2773 +
2774 +1: High level
2749 2749  )))|-
2750 2750  
2751 2751  Table 6-57 Virtual VDI parameters
... ... @@ -2752,7 +2752,7 @@
2752 2752  
2753 2753  (% class="box infomessage" %)
2754 2754  (((
2755 -✎**Note: **“” means VD2F servo drive does not support the function code .
2781 +✎**Note: **“” means VD2F and VD2L servo drive does not support the function code .
2756 2756  )))
2757 2757  
2758 2758  == Port filtering time ==
... ... @@ -2786,26 +2786,30 @@
2786 2786  |=P13-11|Communication VDO_1 output value|Operation setting|Effective immediately|0|0 to 1|(((
2787 2787  VDO_1 output level:
2788 2788  
2789 -* 0: low level
2790 -* 1: high level
2815 +0: Low level
2816 +
2817 +1: High level
2791 2791  )))|-
2792 2792  |=P13-12|Communication VDO_2 output value|Operation setting|Effective immediately|0|0 to 1|(((
2793 2793  VDO_2 output level:
2794 2794  
2795 -* 0: low level
2796 -* 1: high level
2822 +0: Low level
2823 +
2824 +1: High level
2797 2797  )))|-
2798 2798  |=P13-13|Communication VDO_3 output value|Operation setting|Effective immediately|0|0 to 1|(((
2799 2799  VDO_3 output level:
2800 2800  
2801 -* 0: low level
2802 -* 1: high level
2829 +0: Low level
2830 +
2831 +1: High level
2803 2803  )))|-
2804 2804  |=P13-14|Communication VDO_4 output value|Operation setting|Effective immediately|0|0 to 1|(((
2805 2805  VDO_4 output level:
2806 2806  
2807 -* 0: low level
2808 -* 1: high level
2836 +0: Low level
2837 +
2838 +1: High level
2809 2809  )))|-
2810 2810  
2811 2811  Table 6-59 Communication control DO function parameters
... ... @@ -2848,3 +2848,916 @@
2848 2848  (((
2849 2849  ✎**Note:** It is advised to configure function codes for DO terminals in sequence to avoid errors. Please use the shielded overload protection fault detection function with caution, otherwise it will cause burn out the motor.
2850 2850  )))
2881 +
2882 +
2883 +== Homing mode ==
2884 +
2885 +The homing mode is used to find the mechanical origin and locate the positional relationship between the mechanical origin and the mechanical zero.
2886 +
2887 +Mechanical homing: A mechanically fixed position may correspond to a certain defined homing switch, or may correspond to the motor Z signal.
2888 +
2889 +Mechanical zero point: Mechanically absolute 0 position.
2890 +
2891 +After the homing, the stop position of the motor is the mechanical homing. By setting P10-08, the relationship between the mechanical homing and the mechanical zero can be set:
2892 +
2893 +Mechanical homing = Mechanical zero +P10-08 (homing offset)
2894 +
2895 +When P10-08=0, the mechanical homing coincides with the mechanical zero.
2896 +
2897 +
2898 +=== Control block diagram ===
2899 +
2900 +[[image:file:///C:\Users\Administrator\AppData\Local\Temp\ksohtml22584\wps1.png]]Figure 6-53 Homing mode control block diagram
2901 +
2902 +
2903 +
2904 +=== Homing mode related function codes ===
2905 +
2906 +|Function code|Name|(((
2907 +Setting
2908 +
2909 +method
2910 +)))|(((
2911 +Effective
2912 +
2913 +time
2914 +)))|Default|Range|Definition|Unit
2915 +|P01-39.|Homing start mode|(((
2916 +Stop
2917 +
2918 +settings
2919 +)))|(((
2920 +Immediately
2921 +
2922 +effective
2923 +)))|0|0 to 2|(((
2924 +0: Close
2925 +
2926 +1: The servo is powered ON and started after the first ON
2927 +
2928 +2: DI enable
2929 +)))|-
2930 +
2931 +
2932 +|Function code|Name|(((
2933 +Setting
2934 +
2935 +method
2936 +)))|(((
2937 +Effective
2938 +
2939 +time
2940 +)))|Default|Range|Definition|Unit
2941 +|P01-40|Homing mode|(((
2942 +Stop
2943 +
2944 +settings
2945 +)))|(((
2946 +Immediately
2947 +
2948 +effective
2949 +)))|0|0 to 35|(((
2950 +0 ~~ 35 Homing mode;
2951 +
2952 +✎Note: VD2 currently does not support 15, 16, 31, 32 modes
2953 +)))|-
2954 +
2955 +|Function code|Name|(((
2956 +Setting
2957 +
2958 +method
2959 +)))|(((
2960 +Effective
2961 +
2962 +time
2963 +)))|Default|Range|Definition|Unit
2964 +|P01-41|High-speed search deceleration point signal velocity|(((
2965 +Running
2966 +
2967 +settings
2968 +)))|(((
2969 +Immediately
2970 +
2971 +effective
2972 +)))|300|1 to 3000|High-speed search deceleration point signal velocity in homing mode|rpm
2973 +
2974 +|Function code|Name|(((
2975 +Setting
2976 +
2977 +method
2978 +)))|(((
2979 +Effective
2980 +
2981 +time
2982 +)))|Default|Range|Definition|Unit
2983 +|P01-42〇|Low speed search homing signal speed|(((
2984 +Running
2985 +
2986 +settings
2987 +)))|(((
2988 +Immediately
2989 +
2990 +effective
2991 +)))|60|1 to 300|Low-speed search origin signal velocity in homing mode|rpm
2992 +
2993 +|Function code|Name|(((
2994 +Setting
2995 +
2996 +method
2997 +)))|(((
2998 +Effective
2999 +
3000 +time
3001 +)))|Default|Range|Definition|Unit
3002 +|P01-43〇|Homing acceleration and deceleration|(((
3003 +Running
3004 +
3005 +settings
3006 +)))|(((
3007 +Immediately
3008 +
3009 +effective
3010 +)))|50|1to1000|(((
3011 +Acceleration and deceleration in homing mode
3012 +
3013 +Time for speed acceleration from 0 to 1000rpm
3014 +)))|ms
3015 +
3016 +|Function code|Name|(((
3017 +Setting
3018 +
3019 +method
3020 +)))|(((
3021 +Effective
3022 +
3023 +time
3024 +)))|Default|Range|Definition|Unit
3025 +|P01-44〇|Homing timeout limited time|(((
3026 +Running
3027 +
3028 +settings
3029 +)))|(((
3030 +Immediately
3031 +
3032 +effective
3033 +)))|65535|100 to 65535|Homing timeout limited time|ms
3034 +
3035 +|Function code|Name|(((
3036 +Setting
3037 +
3038 +method
3039 +)))|(((
3040 +Effective
3041 +
3042 +time
3043 +)))|Default|Range|Definition|Unit
3044 +|P10-08〇|Multi-turn absolute encoder homing offset compensation|(((
3045 +Running
3046 +
3047 +settings
3048 +)))|(((
3049 +Immediately
3050 +
3051 +effective
3052 +)))|0|(((
3053 +-2147483647~~
3054 +
3055 +2147483646
3056 +)))|(((
3057 +P10-08 multi-turn absolute encoder homing offset compensation is used in conjunction with U0-56 multi-turn absolute encoder current position.
3058 +
3059 +When P10-6 is set to 1, the value of U0-56 is updated to P10-8.
3060 +)))|-
3061 +
3062 +== Introduction to homing mode ==
3063 +
3064 +In the following figure, "H" represents P01-41 (high-speed search deceleration point signal speed), and "L" represents P01-42 (low-speed search homing signal speed).
3065 +
3066 +
3067 +(1) P01-40 =1
3068 +
3069 +Mechanical homing: Motor Z signal
3070 +
3071 +Deceleration point: Reverse limit switch (NOT)
3072 +
3073 +① The deceleration point signal is invalid when starting homing
3074 +
3075 +[[image:file:///C:\Users\Administrator\AppData\Local\Temp\ksohtml22584\wps2.png]]
3076 +
3077 +When it starts to homing, NOT=0, it starts to homing at a high speed in the reverse direction. After encountering the rising edge of NOT, it decelerates and reverses the direction, runs at a low speed in the forward direction, and stops at the first Z signal after encountering the falling edge of NOT.
3078 +
3079 +
3080 +② The deceleration point signal is valid when starting homing
3081 +
3082 +[[image:file:///C:\Users\Administrator\AppData\Local\Temp\ksohtml22584\wps3.png]]
3083 +
3084 +When starting to homing, NOT=1, it starts to homing at a direct forward low speed, and stops at the first Z signal after encountering the falling edge of NOT.
3085 +
3086 +
3087 +
3088 +
3089 +
3090 +
3091 +(2) P01-40=2
3092 +
3093 +Mechanical homing: Motor Z signal
3094 +
3095 +Deceleration point: Positive Limit Switch (POT)
3096 +
3097 +① The deceleration point signal is invalid when starting homing
3098 +
3099 +[[image:file:///C:\Users\Administrator\AppData\Local\Temp\ksohtml22584\wps4.png]]
3100 +
3101 +When it starts to homing, POT = 0, and it starts to homing at a forward high speed. After encountering the rising edge of POT, it decelerates and reverses, runs at a reverse low speed, and stops at the first Z signal after encountering the falling edge of POT.
3102 +
3103 +
3104 +② The deceleration point signal is valid when starting homing
3105 +
3106 +[[image:file:///C:\Users\Administrator\AppData\Local\Temp\ksohtml22584\wps5.png]]
3107 +
3108 +POT=1 when start homing, run at low speed directly in the reverse direction, and stops at the first Z signal after the falling edge of POT.
3109 +
3110 +
3111 +
3112 +
3113 +
3114 +
3115 +
3116 +
3117 +
3118 +
3119 +
3120 +
3121 +
3122 +(3) P01-40=3
3123 +
3124 +Mechanical homing: Motor Z signal
3125 +
3126 +Deceleration point: Home switch (HW)
3127 +
3128 +① The deceleration point signal is invalid when starting homing
3129 +
3130 +[[image:file:///C:\Users\Administrator\AppData\Local\Temp\ksohtml22584\wps6.png]]
3131 +
3132 +When it starts to homing, HW=0. It starts to homing at a forward high speed. After encountering the rising edge of HW, it decelerates and reverses the direction. It runs at a reverse low speed. After encountering the falling edge of HW, it continues to run, and then stops when encountering the first Z signal.
3133 +
3134 +
3135 +② The deceleration point signal is valid when starting homing
3136 +
3137 +[[image:file:///C:\Users\Administrator\AppData\Local\Temp\ksohtml22584\wps7.png]]
3138 +
3139 +When starting homing, HW=1, start homing at low speed in reverse directly, and stop at the first Z signal after encountering the falling edge of HW;
3140 +
3141 +
3142 +
3143 +
3144 +
3145 +
3146 +
3147 +
3148 +
3149 +
3150 +
3151 +
3152 +
3153 +(4) P01-40=4
3154 +
3155 +Mechanical homing: Motor Z signal
3156 +
3157 +Deceleration point: Home switch (HW)
3158 +
3159 +① The deceleration point signal is invalid when starting homing
3160 +
3161 +[[image:file:///C:\Users\Administrator\AppData\Local\Temp\ksohtml22584\wps8.png]]
3162 +
3163 +HW=0 when starting to homing, directly start to homing at low speed, and stop at the first Z signal after encountering the rising edge of HW;
3164 +
3165 +
3166 +② The deceleration point signal is valid when starting homing
3167 +
3168 +[[image:file:///C:\Users\Administrator\AppData\Local\Temp\ksohtml22584\wps9.jpg]]
3169 +
3170 +
3171 +When starting to homing, HW = 1, start to homing at a high speed in the reverse direction. After encountering the falling edge of HW, decelerate and reverse, run at a low speed in the forward direction, and stop at the first Z signal after encountering the rising edge of HW.
3172 +
3173 +
3174 +
3175 +
3176 +
3177 +(5) P01-40=5
3178 +
3179 +Mechanical homing: Motor Z signal
3180 +
3181 +Deceleration point: Home switch (HW)
3182 +
3183 +① The deceleration point signal is invalid when starting homing
3184 +
3185 +[[image:file:///C:\Users\Administrator\AppData\Local\Temp\ksohtml22584\wps10.png]]
3186 +
3187 +When it starts to homing, HW = 0, and it starts to homing at a reverse high speed. After encountering the rising edge of HW, it decelerates and reverses the direction, runs at a forward low speed, and stops at the first Z signal after encountering the falling edge of HW.
3188 +
3189 +
3190 +② The deceleration point signal is valid when starting homing
3191 +
3192 +[[image:file:///C:\Users\Administrator\AppData\Local\Temp\ksohtml22584\wps11.png]]
3193 +
3194 +When starting homing, HW=1, it will start homing directly at low speed, and the first Z signal after encountering the falling edge of HW will stop;
3195 +
3196 +
3197 +
3198 +
3199 +
3200 +(6) P01-40=6
3201 +
3202 +Mechanical homing: Motor Z signal
3203 +
3204 +Deceleration point: Home switch (HW)
3205 +
3206 +① The deceleration point signal is invalid when starting homing
3207 +
3208 +[[image:file:///C:\Users\Administrator\AppData\Local\Temp\ksohtml22584\wps12.png]]
3209 +
3210 +When starting to homing, HW=0, directly reverse low speed starts to homing, and the first Z signal stops after encountering the rising edge of HW;
3211 +
3212 +
3213 +② The deceleration point signal is valid when starting homing
3214 +
3215 +[[image:file:///C:\Users\Administrator\AppData\Local\Temp\ksohtml22584\wps13.png]]
3216 +
3217 +When starting to homing, HW = 1, start to homing at a forward high speed, after encountering the falling edge of HW, decelerate and reverse, run at a reverse low speed, and stop at the first Z signal after encountering the rising edge of HW.
3218 +
3219 +
3220 +
3221 +
3222 +
3223 +(7) P01-40=7
3224 +
3225 +Mechanical homing: Motor Z signal
3226 +
3227 +Deceleration point: Home switch (HW)
3228 +
3229 +① The deceleration point signal is invalid when starting homing, the forward limit switch is not encountered
3230 +
3231 +[[image:file:///C:\Users\Administrator\AppData\Local\Temp\ksohtml22584\wps14.png]]
3232 +
3233 +When it starts to homing, HW = 0, and it starts to homing at a forward high speed. If the limit switch is not encountered, after encountering the rising edge of HW, it decelerates and reverses the direction, and runs at a reverse low speed. The first Z signal after encountering the falling edge of HW stops.
3234 +
3235 +
3236 +When homing, the deceleration point signal is invalid and the forward limit switch is encountered
3237 +
3238 +[[image:file:///C:\Users\Administrator\AppData\Local\Temp\ksohtml22584\wps15.jpg]]
3239 +
3240 +When it starts to homing, HW = 0, and it starts to homing at a forward high speed. If it encounters a limit switch, it will automatically reverse and run at a reverse high speed. After encountering the rising edge of HW, it will slow down and continue to run at a reverse low speed. The first Z signal after the falling edge of HW will stop.
3241 +
3242 +
3243 +③ The deceleration point signal is valid when starting homing
3244 +
3245 +[[image:file:///C:\Users\Administrator\AppData\Local\Temp\ksohtml22584\wps16.png]]
3246 +
3247 +When starting homing, HW=1, then directly reverse the low speed to start homing, and stop the first Z signal after encountering the falling edge of HW;
3248 +
3249 +
3250 +(8) P01-40=8
3251 +
3252 +Mechanical homing: Motor Z signal
3253 +
3254 +Deceleration point: Home switch (HW)
3255 +
3256 +① The deceleration point signal is invalid when starting homing, the forward limit switch is not encountered
3257 +
3258 +[[image:file:///C:\Users\Administrator\AppData\Local\Temp\ksohtml22584\wps17.png]]
3259 +
3260 +When it starts to homing, HM-0 starts to homing at a forward high speed. If it does not encounter the limit switch, after encountering the rising edge of HW, slow down and reverse, and run at a reverse low speed. After encountering the falling edge of HW, reverse, run at a forward low speed, and stop at the first Z signal after encountering the rising edge of HW.
3261 +
3262 +
3263 +① The deceleration point signal is invalid when starting homing, the forward limit switch is encountered
3264 +
3265 +[[image:file:///C:\Users\Administrator\AppData\Local\Temp\ksohtml22584\wps18.png]]
3266 +
3267 +When it starts to homing, HW = 0, and it starts to homing at forward high speed. If it encounters a limit switch, it will automatically reverse and run at reverse high speed; After encountering the rising edge of HW, slow down and run at a reverse low speed; After encountering the falling edge of HW, reverse the direction, run at a forward low speed, and stop the first Z signal after encountering the rising edge of HW.
3268 +
3269 +
3270 +③ The deceleration point signal is valid when starting homing
3271 +
3272 +[[image:file:///C:\Users\Administrator\AppData\Local\Temp\ksohtml22584\wps19.png]]
3273 +
3274 +When starting to homing, HM-1 will directly reverse and start to return to zero at low speed. After encountering the falling edge of HW, it will reverse and run at forward low speed. The first Z signal after encountering the rising edge of HW will stop.
3275 +
3276 +
3277 +
3278 +(9) P01-40=9
3279 +
3280 +Mechanical homing: Motor Z signal
3281 +
3282 +Deceleration point: Home switch (HW)
3283 +
3284 +① The deceleration point signal is invalid when starting homing, the forward limit switch is not encountered
3285 +
3286 +[[image:file:///C:\Users\Administrator\AppData\Local\Temp\ksohtml22584\wps20.png]]
3287 +
3288 +When it starts to homing, HW=0, and it starts to homing at a forward high speed. If the limit switch is not encountered, after encountering the rising edge of HW, it decelerates and runs at a forward low speed; After encountering the falling edge of HW, reverse, run at a low speed in the reverse direction, and stop at the first Z signal after encountering the rising edge of HW.
3289 +
3290 +
3291 +① The deceleration point signal is invalid when starting homing, the forward limit switch is encountered
3292 +
3293 +[[image:file:///C:\Users\Administrator\AppData\Local\Temp\ksohtml22584\wps21.png]]
3294 +
3295 +When it starts to homing, HW = 0, and it starts to homing at a forward high speed. If it encounters a limit switch, it will automatically reverse and run at a reverse high speed. After encountering a rising edge of HW, it will slow down and reverse to resume forward operation. Running at a forward low speed, after encountering a falling edge of HW, it will reverse. During reverse low speed operation, the first Z signal after encountering a rising edge of HW will stop.
3296 +
3297 +③ The deceleration point signal is valid when starting homing
3298 +
3299 +[[image:file:///C:\Users\Administrator\AppData\Local\Temp\ksohtml22584\wps22.png]]
3300 +
3301 +When starting homing, HW=1 starts homing directly at forward low speed. After encountering the falling edge of HW, the first Z signal after encountering the rising edge of HW stops in reverse and reverse low speed operation;
3302 +
3303 +
3304 +(10) P01-40=10
3305 +
3306 +Mechanical homing: Motor Z signal
3307 +
3308 +Deceleration point: Home switch (HW)
3309 +
3310 +① The deceleration point signal is invalid when starting homing, the forward limit switch is not encountered
3311 +
3312 +[[image:file:///C:\Users\Administrator\AppData\Local\Temp\ksohtml22584\wps23.png]]
3313 +
3314 +When it starts to homing, HW = 0, and it starts to homing at a forward high speed. If the limit switch is not encountered, after encountering the rising edge of HW, slow down and run at a forward low speed. After encountering the falling edge of HW, continue to run at a forward low speed, and then the first Z signal encountered stops.
3315 +
3316 +When homing, the deceleration point signal is invalid and the forward limit switch is encountered
3317 +
3318 +[[image:file:///C:\Users\Administrator\AppData\Local\Temp\ksohtml22584\wps24.jpg]]
3319 +
3320 +When it starts to homing, HW = 0, and it starts to homing at a forward high speed. If it encounters a limit switch, it will automatically reverse and run at a reverse high speed. After encountering the rising edge of HW, it will slow down and reverse to resume forward operation. The first Z signal after the low speed encounters the falling edge of HW will stop.
3321 +
3322 +
3323 +③ The deceleration point signal is valid when starting homing
3324 +
3325 +[[image:file:///C:\Users\Administrator\AppData\Local\Temp\ksohtml22584\wps25.png]]
3326 +
3327 +When starting homing, HW=1, it will start homing directly at low speed, and the first Z signal after encountering the falling edge of HW will stop;
3328 +
3329 +
3330 +(11) P01-40=11
3331 +
3332 +Mechanical homing: Motor Z signal
3333 +
3334 +Deceleration point: Home switch (HW)
3335 +
3336 +① The deceleration point signal is invalid when starting homing, the reverse limit switch is not encountered
3337 +
3338 +[[image:file:///C:\Users\Administrator\AppData\Local\Temp\ksohtml22584\wps26.png]]
3339 +
3340 +When it starts to homing, HW=0, and it starts to homing at a reverse high speed. If the limit switch is not encountered, after encountering the rising edge of HW, it decelerates and reverses the direction, runs at a forward low speed, and stops at the first Z signal after encountering the falling edge of HW.
3341 +
3342 +
3343 +① The deceleration point signal is invalid when starting homing, the reverse limit switch is encountered
3344 +
3345 +[[image:file:///C:\Users\Administrator\AppData\Local\Temp\ksohtml22584\wps27.png]]
3346 +
3347 +When it starts to homing, HW=0, and it starts to homing at a reverse high speed. If it encounters a limit switch, it will automatically reverse and run at a forward high speed. After encountering a rising edge of HW, slow down and continue to run at a forward low speed. When encountering a falling edge of HW, the first Z signal after the edge stops.
3348 +
3349 +③ The deceleration point signal is valid when starting homing
3350 +
3351 +[[image:file:///C:\Users\Administrator\AppData\Local\Temp\ksohtml22584\wps28.png]]
3352 +
3353 +When starting homing, HW=1, it will start homing directly at low speed, and the first Z signal after encountering the falling edge of HW will stop;
3354 +
3355 +
3356 +(12) P01-40=12
3357 +
3358 +Mechanical homing: Motor Z signal
3359 +
3360 +Deceleration point: Home switch (HW)
3361 +
3362 +① The deceleration point signal is invalid when starting homing, the reverse limit switch is not encountered
3363 +
3364 +[[image:file:///C:\Users\Administrator\AppData\Local\Temp\ksohtml22584\wps29.png]]
3365 +
3366 +When it starts to homing, HW = 0, it starts to homing at a reverse high speed, and does not encounter a limit switch. After encountering the rising edge of HW, it decelerates and reverses, and runs at a forward low speed. After encountering the falling edge of HW, it reverses and runs at a reverse low speed, and stops at the first Z signal after encountering the rising edge of HW.
3367 +
3368 +
3369 +
3370 +① The deceleration point signal is invalid when starting homing, the reverse limit switch is encountered
3371 +
3372 +[[image:file:///C:\Users\Administrator\AppData\Local\Temp\ksohtml22584\wps30.png]]
3373 +
3374 +When it starts to homing, HW=0, it starts to homing at a reverse high speed, encounters a limit switch, automatically reverses, runs at a forward high speed, encounters a rising edge of HW, decelerates, runs at a forward low speed, encounters a falling edge of HW, reverses, runs at a reverse low speed, and stops at the first Z signal after encountering a rising edge of HW.
3375 +
3376 +
3377 +③ The deceleration point signal is valid when starting homing
3378 +
3379 +[[image:file:///C:\Users\Administrator\AppData\Local\Temp\ksohtml22584\wps31.png]]
3380 +
3381 +When starting to homing, HW = 1, it will directly start to homing at a forward low speed. After encountering the falling edge of HW, it will reverse and run at a reverse low speed. The first Z signal after encountering the rising edge of HW will stop.
3382 +
3383 +(13) P01-40=13
3384 +
3385 +Mechanical homing: Motor Z signal
3386 +
3387 +Deceleration point: Home switch (HW)
3388 +
3389 +① The deceleration point signal is invalid when starting homing, the reverse limit switch is not encountered
3390 +
3391 +[[image:file:///C:\Users\Administrator\AppData\Local\Temp\ksohtml22584\wps32.png]]
3392 +
3393 +When it starts to homing, HW=0, and it starts to homing at a reverse high speed. If it does not encounter the limit switch, after encountering the rising edge of HW, slow down and run at a reverse low speed. After encountering the falling edge of HW, reverse and run at a forward low speed, and stop at the first Z signal after encountering the rising edge of HW.
3394 +
3395 +
3396 +① The deceleration point signal is invalid when starting homing, the reverse limit switch is encountered
3397 +
3398 +[[image:file:///C:\Users\Administrator\AppData\Local\Temp\ksohtml22584\wps33.png]]
3399 +
3400 +When it starts to homing, HW=0, it starts to homing at reverse high speed, encounters the limit switch, automatically reverses, runs at forward high speed, after encountering the rising edge of HW, decelerates and runs in reverse low speed, and encounters the falling edge of HW when running at reverse low speed, the first Z signal after encountering the rising edge of HW stops.
3401 +
3402 +③ The deceleration point signal is valid when starting homing
3403 +
3404 +[[image:file:///C:\Users\Administrator\AppData\Local\Temp\ksohtml22584\wps34.png]]
3405 +
3406 +When starting homing, HW=1 starts homing directly at reverse low speed. After encountering the falling edge of HW, the first Z signal after encountering the rising edge of HW stops in reverse and forward low speed operation;
3407 +
3408 +
3409 +(14) P01-40=14
3410 +
3411 +Mechanical homing: Motor Z signal
3412 +
3413 +Deceleration point: Home switch (HW)
3414 +
3415 +① The deceleration point signal is invalid when starting homing, the reverse limit switch is not encountered
3416 +
3417 +[[image:file:///C:\Users\Administrator\AppData\Local\Temp\ksohtml22584\wps35.png]]
3418 +
3419 +When it starts to homing, HW=0, it starts to homing at reverse high speed, and does not encounter the limit switch. After encountering the rising edge of HW, it decelerates and runs at reverse low speed. After encountering the falling edge of HW, it continues to run at reverse low speed, and then the first Z signal encountered stops.
3420 +
3421 +
3422 +① The deceleration point signal is invalid when starting homing, the reverse limit switch is encountered
3423 +
3424 +[[image:file:///C:\Users\Administrator\AppData\Local\Temp\ksohtml22584\wps36.png]]
3425 +
3426 +When it starts to homing, HW = 0, it starts to homing at a reverse high speed, encounters a limit switch, automatically reverses, runs at a forward high speed, encounters a rising edge of HW, decelerates and runs in a reverse direction, and stops the first Z signal after encountering a falling edge of HW at a reverse low speed.
3427 +
3428 +
3429 +③ The deceleration point signal is valid when starting homing
3430 +
3431 +[[image:file:///C:\Users\Administrator\AppData\Local\Temp\ksohtml22584\wps37.png]]
3432 +
3433 +When starting homing, HW=1, then directly reverse the low speed to start homing, and stop the first Z signal after encountering the falling edge of HW;
3434 +
3435 +
3436 +(15) P01-40=17
3437 +
3438 +Mechanical homing: Negative overrun switch (NOT)
3439 +
3440 +Deceleration point: Negative overrun switch (NOT)
3441 +
3442 +① The deceleration point signal is invalid when starting homing
3443 +
3444 +[[image:file:///C:\Users\Administrator\AppData\Local\Temp\ksohtml22584\wps38.png]]
3445 +
3446 +When it starts to homing, NOT = 0, it starts to homing at a high speed in the reverse direction. After encountering the rising edge of NOT, it decelerates and reverses the direction, runs at a low speed in the forward direction, and stops after encountering the falling edge of NOT.
3447 +
3448 +
3449 +② The deceleration point signal is valid when starting homing
3450 +
3451 +[[image:file:///C:\Users\Administrator\AppData\Local\Temp\ksohtml22584\wps39.png]]
3452 +
3453 +When starting homing, NOT=1, start homing directly at low speed, and stop after encountering the falling edge of NOT.
3454 +
3455 +
3456 +(16) P01-40=18
3457 +
3458 +Mechanical homing: Positive overrun switch (POT)
3459 +
3460 +Deceleration point: Positive overrun switch (POT)
3461 +
3462 +① The deceleration point signal is invalid when starting homing
3463 +
3464 +[[image:file:///C:\Users\Administrator\AppData\Local\Temp\ksohtml22584\wps40.png]]
3465 +
3466 +When it starts to return to zero, POT=0, it starts to homing at a forward high speed, after encountering the rising edge of POT, it decelerates and reverses, runs at a reverse low speed, and stops after encountering the falling edge of POT.
3467 +
3468 +
3469 +② The deceleration point signal is valid when starting homing
3470 +
3471 +[[image:file:///C:\Users\Administrator\AppData\Local\Temp\ksohtml22584\wps41.png]]
3472 +
3473 +When starting homing, POT=1, start homing at low speed in reverse directly, and stop when encountering POT falling edge;
3474 +
3475 +
3476 +
3477 +(17) P01-40=19
3478 +
3479 +Mechanical homing: Home switch (HW)
3480 +
3481 +Deceleration point: Home switch (HW)
3482 +
3483 +① The deceleration point signal is invalid when starting homing
3484 +
3485 +[[image:file:///C:\Users\Administrator\AppData\Local\Temp\ksohtml22584\wps42.png]]
3486 +
3487 +When it starts to homing, HW=0, and it starts to homing at a forward high speed. After encountering the rising edge of HW, it decelerates and reverses the direction, runs at a reverse low speed, and stops when encountering the falling edge of HW.
3488 +
3489 +
3490 +② The deceleration point signal is valid when starting homing
3491 +
3492 +[[image:file:///C:\Users\Administrator\AppData\Local\Temp\ksohtml22584\wps43.png]]
3493 +
3494 +When starting homing, HW=1, start homing at low speed in reverse directly, and stop when encountering HW falling edge;
3495 +
3496 +
3497 +(18) P01-40=20
3498 +
3499 +Mechanical homing: Home switch (HW)
3500 +
3501 +Deceleration point: Home switch (HW)
3502 +
3503 +① The deceleration point signal is invalid when starting homing
3504 +
3505 +[[image:file:///C:\Users\Administrator\AppData\Local\Temp\ksohtml22584\wps44.png]]
3506 +
3507 +When starting to homing, HW=0, directly start to homing at low speed, and stop after encountering the rising edge of HW;
3508 +
3509 +
3510 +② The deceleration point signal is valid when starting homing
3511 +
3512 +[[image:file:///C:\Users\Administrator\AppData\Local\Temp\ksohtml22584\wps45.png]]
3513 +
3514 +When starting to homing, HW = 1, start to homing at a high speed in the reverse direction. After encountering the falling edge of HW, slow down and reverse the direction, run at a low speed in the forward direction, and stop when encountering the rising edge of HW.
3515 +
3516 +
3517 +(19) P01-40=21
3518 +
3519 +Mechanical homing: Home switch (HW)
3520 +
3521 +Deceleration point: Home switch (HW)
3522 +
3523 +① The deceleration point signal is invalid when starting homing
3524 +
3525 +[[image:file:///C:\Users\Administrator\AppData\Local\Temp\ksohtml22584\wps46.png]]
3526 +
3527 +When it starts to homing, HW=0, it starts to homing at a reverse high speed. After encountering the rising edge of HW, it decelerates and reverses the direction, runs at a forward low speed, and stops when encountering the falling edge of HW.
3528 +
3529 +
3530 +② The deceleration point signal is valid when starting homing
3531 +
3532 +[[image:file:///C:\Users\Administrator\AppData\Local\Temp\ksohtml22584\wps47.png]]
3533 +
3534 +When starting back to zero, HW=1, it will start homing directly at low speed, and stop after encountering the falling edge of HW;
3535 +
3536 +
3537 +(20) P01-40=22
3538 +
3539 +Mechanical homing: Home switch (HW)
3540 +
3541 +Deceleration point: Home switch (HW)
3542 +
3543 +① The deceleration point signal is invalid when starting homing
3544 +
3545 +[[image:file:///C:\Users\Administrator\AppData\Local\Temp\ksohtml22584\wps48.png]]
3546 +
3547 +When starting to homing, HW=0, directly reverse low speed starts to homing, and stops when encountering HW rising edge;
3548 +
3549 +
3550 +Deceleration point signal is valid when homing start
3551 +
3552 +[[image:file:///C:\Users\Administrator\AppData\Local\Temp\ksohtml22584\wps49.jpg]]
3553 +
3554 +When starting to homing, HW=1, start to homing at a forward high speed, after encountering the falling edge of HW, slow down and reverse, run at a reverse low speed, and stop when encountering the rising edge of HW.
3555 +
3556 +
3557 +(21) P01-40=23
3558 +
3559 +Mechanical homing: Home switch (HW)
3560 +
3561 +Deceleration point: Home switch (HW)
3562 +
3563 +① The deceleration point signal is invalid when starting homing, the forward limit switch is not encountered
3564 +
3565 +[[image:file:///C:\Users\Administrator\AppData\Local\Temp\ksohtml22584\wps50.png]]
3566 +
3567 +When it starts to homing, HW = 0, it starts to homing at a forward high speed, and does not encounter a limit switch. After encountering the rising edge of HW, it decelerates and reverses, runs at a reverse low speed, and stops when encountering the falling edge of HW.
3568 +
3569 +
3570 +① The deceleration point signal is invalid when starting homing, the forward limit switch is encountered
3571 +
3572 +[[image:file:///C:\Users\Administrator\AppData\Local\Temp\ksohtml22584\wps51.png]]
3573 +
3574 +When you start homing, HW = 0, start homing at a forward high speed. When encountering the limit switch, it will automatically reverse and run at a reverse high speed. After encountering the rising edge of HW, slow down, continue to run at reverse low speed, and stop when encountering the HW falling edge.
3575 +
3576 +
3577 +
3578 +③ The deceleration point signal is valid when starting homing
3579 +
3580 +[[image:file:///C:\Users\Administrator\AppData\Local\Temp\ksohtml22584\wps52.png]]
3581 +
3582 +When it starts to homing, HW=1, it starts to homing at a reverse low speed, and stops when it encounters the falling edge of HW.
3583 +
3584 +
3585 +(22) P01-40=24
3586 +
3587 +Mechanical homing: Home switch (HW)
3588 +
3589 +Deceleration point: Home switch (HW)
3590 +
3591 +① The deceleration point signal is invalid when starting homing, the forward limit switch is not encountered
3592 +
3593 +[[image:file:///C:\Users\Administrator\AppData\Local\Temp\ksohtml22584\wps53.png]]
3594 +
3595 +When it starts to homing, HW = 0, it starts to homing at a forward high speed, and does not encounter a limit switch. After encountering the rising edge of HW, it decelerates and reverses, and runs at a reverse low speed. After encountering the falling edge of HW, it reverses and runs at a forward low speed, and stops when encountering the rising edge of HW.
3596 +
3597 +
3598 +① The deceleration point signal is invalid when starting homing, the forward limit switch is encountered
3599 +
3600 +[[image:file:///C:\Users\Administrator\AppData\Local\Temp\ksohtml22584\wps54.png]]
3601 +
3602 +When it starts to homing, HW = 0, it starts to homing at forward high speed, encounters the limit switch, automatically reverses, runs at reverse high speed, encounters the rising edge of HW, decelerates and runs at reverse low speed, encounters the falling edge of HW, reverses, runs at forward low speed, and stops when encountering the rising edge of HW.
3603 +
3604 +
3605 +③ The deceleration point signal is valid when starting homing
3606 +
3607 +[[image:file:///C:\Users\Administrator\AppData\Local\Temp\ksohtml22584\wps55.png]]
3608 +
3609 +When starting with homing, HW = 1, it will directly reverse the low speed and start to homing. After encountering the falling edge of HW, it will reverse the direction and run at a forward low speed, and stop when encountering the rising edge of HW.
3610 +
3611 +
3612 +(23) P01-40=25
3613 +
3614 +Mechanical homing: Home switch (HW)
3615 +
3616 +Deceleration point: Home switch (HW)
3617 +
3618 +① The deceleration point signal is invalid when starting homing, the forward limit switch is not encountered
3619 +
3620 +[[image:file:///C:\Users\Administrator\AppData\Local\Temp\ksohtml22584\wps56.png]]
3621 +
3622 +When it starts to homing, HW=0, it starts to homing at a forward high speed, and does not encounter a limit switch. After encountering the rising edge of HW, it decelerates and runs at a forward low speed. After encountering the falling edge of HW, it reverses and runs at a reverse low speed, and stops when encountering the rising edge of HW.
3623 +
3624 +
3625 +① The deceleration point signal is invalid when starting homing, the forward limit switch is encountered
3626 +
3627 +[[image:file:///C:\Users\Administrator\AppData\Local\Temp\ksohtml22584\wps57.png]]
3628 +
3629 +When it starts to homing, HW=0, it starts to homing at forward high speed, encounters the limit switch, automatically reverses, and runs at reverse high speed. After encountering the rising edge of HW, decelerate and reverse to resume forward operation. After encountering the falling edge of HW at forward low speed, reverse. When running at reverse low speed, stop when encountering the rising edge of HW.
3630 +
3631 +
3632 +③ The deceleration point signal is valid when starting homing
3633 +
3634 +[[image:file:///C:\Users\Administrator\AppData\Local\Temp\ksohtml22584\wps58.png]]
3635 +
3636 +When starting homing, when HW=1, it starts to homing directly at low speed in the forward direction. After encountering the falling edge of HW, it stops at the rising edge of HW in the reverse low speed operation
3637 +
3638 +
3639 +(24) P01-40=26
3640 +
3641 +Mechanical homing: Home switch (HW)
3642 +
3643 +Deceleration point: Home switch (HW)
3644 +
3645 +① The deceleration point signal is invalid when starting homing, the forward limit switch is not encountered
3646 +
3647 +[[image:file:///C:\Users\Administrator\AppData\Local\Temp\ksohtml22584\wps59.png]]
3648 +
3649 +When it starts to homing, HW=0, it starts to homing at a forward high speed, and does not encounter a limit switch. After encountering the rising edge of HW, it decelerates, runs at a forward low speed, and stops when encountering the falling edge of HW.
3650 +
3651 +
3652 +① The deceleration point signal is invalid when starting homing, the forward limit switch is encountered
3653 +
3654 +[[image:file:///C:\Users\Administrator\AppData\Local\Temp\ksohtml22584\wps60.png]]
3655 +
3656 +When it starts to homing, HW=0, it starts to homing at forward high speed, encounters the limit switch, automatically reverses, and runs at reverse high speed. After encountering the rising edge of HW, decelerates and reverses to resume forward operation, and stops when encountering the falling edge of HW at forward low speed.
3657 +
3658 +
3659 +③ The deceleration point signal is valid when starting homing
3660 +
3661 +[[image:file:///C:\Users\Administrator\AppData\Local\Temp\ksohtml22584\wps61.png]]
3662 +
3663 +When starting homing, HW=1, it will start homing directly at low speed, and stop when encountering HW falling edge;
3664 +
3665 +
3666 +(25) P01-40=27
3667 +
3668 +Mechanical homing: Home switch (HW)
3669 +
3670 +Deceleration point: Home switch (HW)
3671 +
3672 +① The deceleration point signal is invalid when starting homing, the reverse limit switch is not encountered
3673 +
3674 +[[image:file:///C:\Users\Administrator\AppData\Local\Temp\ksohtml22584\wps62.png]]
3675 +
3676 +When it starts to homing, HW=0, it starts to homing at a reverse high speed, and does not encounter a limit switch. After encountering the rising edge of HW, it decelerates and reverses the direction, runs at a forward low speed, and stops when encountering the falling edge of HW.
3677 +
3678 +
3679 +① The deceleration point signal is invalid when starting homing, the reverse limit switch is encountered
3680 +
3681 +[[image:file:///C:\Users\Administrator\AppData\Local\Temp\ksohtml22584\wps63.png]]
3682 +
3683 +When it starts to homing, HW=0, it starts to homing at a reverse high speed. When it encounters a limit switch, it automatically reverses and runs at a forward high speed. When it encounters a rising edge of HW, it decelerates and continues to run at a forward low speed. When it encounters a falling edge of HW, it stops.
3684 +
3685 +
3686 +③ The deceleration point signal is valid when starting homing
3687 +
3688 +[[image:file:///C:\Users\Administrator\AppData\Local\Temp\ksohtml22584\wps64.png]]
3689 +
3690 +When starting homing, HW=1, it will start homing directly at low speed, and stop when encountering HW falling edge;
3691 +
3692 +
3693 +(26) P01-40=28
3694 +
3695 +Mechanical homing: Home switch (HW)
3696 +
3697 +Deceleration point: Home switch (HW)
3698 +
3699 +① The deceleration point signal is invalid when starting homing, the reverse limit switch is not encountered
3700 +
3701 +[[image:file:///C:\Users\Administrator\AppData\Local\Temp\ksohtml22584\wps65.png]]
3702 +
3703 +When it starts to homing, HW=0, it starts to homing at a reverse high speed, and does not encounter a limit switch. After encountering the rising edge of HW, it decelerates and reverses, and runs at a forward low speed. After encountering the falling edge of HW, it reverses and runs at a reverse low speed, and stops when encountering the rising edge of HW.
3704 +
3705 +
3706 +① The deceleration point signal is invalid when starting homing, the reverse limit switch is encountered
3707 +
3708 +[[image:file:///C:\Users\Administrator\AppData\Local\Temp\ksohtml22584\wps66.png]]
3709 +
3710 +When it starts to homing, HW=0, it starts to homing at a reverse high speed. When encountering a limit switch, it automatically reverses and runs at a forward high speed. When encountering a rising edge of HW, it decelerates and runs at a forward low speed. When encountering a falling edge of HW, it reverses and runs at a reverse low speed. When encountering a rising edge of HW, it stops.
3711 +
3712 +
3713 +③ The deceleration point signal is valid when starting homing
3714 +
3715 +[[image:file:///C:\Users\Administrator\AppData\Local\Temp\ksohtml22584\wps67.png]]
3716 +
3717 +When starting with homing, HW = 1, it will directly start to homing at a forward low speed. After encountering the falling edge of HW, it will reverse and run at a reverse low speed. When encountering the rising edge of HW, it will stop.
3718 +
3719 +
3720 +(27) P01-40=29
3721 +
3722 +Mechanical homing: Home switch (HW)
3723 +
3724 +Deceleration point: Home switch (HW)
3725 +
3726 +① The deceleration point signal is invalid when starting homing, the reverse limit switch is not encountered
3727 +
3728 +[[image:file:///C:\Users\Administrator\AppData\Local\Temp\ksohtml22584\wps68.png]]
3729 +
3730 +When it starts to homing, HW = 0, it starts to homing at a reverse high speed, and does not encounter a limit switch. After encountering the rising edge of HW, it decelerates and runs at a reverse low speed. After encountering the falling edge of HW, it reverses and runs at a forward low speed, and stops when encountering the rising edge of HW.
3731 +
3732 +
3733 +① The deceleration point signal is invalid when starting homing, the reverse limit switch is encountered
3734 +
3735 +[[image:file:///C:\Users\Administrator\AppData\Local\Temp\ksohtml22584\wps69.png]]
3736 +
3737 +When it starts to homing, HW=0, it starts to homing at a reverse high speed. When it encounters a limit switch, it automatically reverses and runs at a forward high speed. After encountering a rising edge of HW, it decelerates and runs in a reverse low speed. After encountering a falling edge of HW, it reverses. When running at a forward low speed, it stops when it encounters a rising edge of HW.
3738 +
3739 +③ The deceleration point signal is valid when starting homing
3740 +
3741 +[[image:file:///C:\Users\Administrator\AppData\Local\Temp\ksohtml22584\wps70.png]]
3742 +
3743 +When starting homing, when HW=1, it starts to homing directly at low speed in reverse direction. After encountering the falling edge of HW, it stops when running at low speed in reverse direction and forward direction and encountering the rising edge of HW
3744 +
3745 +
3746 +(28) P01-40=30
3747 +
3748 +Mechanical homing: Home switch (HW)
3749 +
3750 +Deceleration point: Home switch (HW)
3751 +
3752 +① The deceleration point signal is invalid when starting homing, the reverse limit switch is not encountered
3753 +
3754 +[[image:file:///C:\Users\Administrator\AppData\Local\Temp\ksohtml22584\wps71.png]]
3755 +
3756 +When it starts to homing, HW=0, it starts to homing at reverse high speed, and does not encounter the limit switch. After encountering the rising edge of HW, it decelerates, runs at reverse low speed, and stops when encountering the falling edge of HW.
3757 +
3758 +
3759 +① The deceleration point signal is invalid when starting homing, the reverse limit switch is encountered
3760 +
3761 +[[image:file:///C:\Users\Administrator\AppData\Local\Temp\ksohtml22584\wps72.png]]
3762 +
3763 +When it starts to homing, HW=0, it starts to homing at a reverse high speed. When it encounters a limit switch, it automatically reverses and runs at a forward high speed. When it encounters a rising edge of HW, it decelerates and runs in a reverse low speed. When it encounters a falling edge of HW, it stops.
3764 +
3765 +
3766 +③ The deceleration point signal is valid when starting homing
3767 +
3768 +[[image:file:///C:\Users\Administrator\AppData\Local\Temp\ksohtml22584\wps73.png]]
3769 +
3770 +When starting homing, HW=1, start homing at low speed in reverse directly, and stop when encountering HW falling edge;
3771 +
3772 +
3773 +(29) P01-40=33 and P01-40=34
3774 +
3775 +Mechanical homing: Z signal.
3776 +
3777 +Deceleration point: None
3778 +
3779 +Homing mode 33: Reverse low speed operation, stop the first Z signal encountered
3780 +
3781 +Homing mode 34: running at low speed in forward direction, stopping the first Z signal encountered
3782 +
3783 +[[image:file:///C:\Users\Administrator\AppData\Local\Temp\ksohtml22584\wps74.png]]
3784 +
3785 +
3786 +(30) P01-40=35
3787 +
3788 +Homing mode 35, taking the current position as the mechanical homing, after triggering the homing (P01-39: 0x00→0x01/0x00 → 0x02);
3789 +
3790 +After the homing is completed, according to the set value of P10-08 (homing bias compensation), P10-06 (encoder multi-turn reset operation) is executed.
3791 +
3792 +
3793 +