... ... @@ -1969,7 +1969,7 @@
1969 1969  
1970 1970  |=(% scope="row" %)**DO function code**|=(% style="width: 247px;" %)**Function name**|=(% style="width: 695px;" %)**Function**
1971 1971  |=132|(% style="width:247px" %)(((
1972 -T-COIN rotation detection
1972 +TGON rotation detection
1973 1973  )))|(% style="width:695px" %)(((
1974 1974  Valid: when the absolute value of motor speed after filtering is greater than or equal to the set value of function code P05-16
1975 1975  
... ... @@ -2037,7 +2037,7 @@
2037 2037  
2038 2038  |=(% scope="row" %)**DO Function code**|=(% style="width: 262px;" %)**Function name**|=(% style="width: 684px;" %)**Function**
2039 2039  |=136|(% style="width:262px" %)(((
2040 -U-COIN consistent speed
2040 +V-COIN consistent speed
2041 2041  )))|(% style="width:684px" %)The output signal indicates that the absolute deviation of the actual speed of servo motor and the speed instruction meets the P05-17 set value
2042 2042  
2043 2043  Table 6-39 DO speed consistent function code
... ... @@ -2221,8 +2221,9 @@
2221 2221  )))|(((
2222 2222  Effective immediately
2223 2223  )))|0|0 to 1|(((
2224 -* 0: internal value
2225 -* 1: AI_1 analog input (not supported by VD2F and VD2L)
2224 +0: internal value
2225 +
2226 +1: AI_1 analog input (not supported by VD2F and VD2L)
2226 2226  )))|-
2227 2227  
2228 2228  * Torque limit source is internal torque instruction (P01-14=0)
... ... @@ -2299,7 +2299,7 @@
2299 2299  Operation setting
2300 2300  )))|(((
2301 2301  Effective immediately
2302 -)))|3000|0 to 5000|(((
2303 +)))|3000|0 to 6000|(((
2303 2303  Forward torque
2304 2304  
2305 2305  limit in torque mode
... ... @@ -2312,7 +2312,7 @@
2312 2312  Operation setting
2313 2313  )))|(((
2314 2314  Effective immediately
2315 -)))|3000|0 to 5000|(((
2316 +)))|3000|0 to 6000|(((
2316 2316  Reverse torque
2317 2317  
2318 2318  limit in torque mode
... ... @@ -2397,13 +2397,18 @@
2397 2397  )))|(((
2398 2398  Shutdown setting
2399 2399  )))|1|(% style="width:90px" %)1 to 6|(% style="width:273px" %)(((
2400 -* 1: Position control
2401 -* 2: Speed control
2402 -* 3: Torque control
2403 -* 4: Position/speed mixed control
2404 -* 5: Position/torque mixed control
2405 -* 6: Speed/torque mixed control
2401 +1: Position control
2406 2406  
2403 +2: Speed control
2404 +
2405 +3: Torque control
2406 +
2407 +4: Position/speed mixed control
2408 +
2409 +5: Position/torque mixed control
2410 +
2411 +6: Speed/torque mixed control
2412 +
2407 2407  **VD2L drive P0-01 setting range: 1-3, not support mixed mode**
2408 2408  )))|-
2409 2409  
... ... @@ -2545,8 +2545,9 @@
2545 2545  **time**
2546 2546  )))|=**Default value**|=**Range**|=**Definition**|=**Unit**
2547 2547  |=P00-30|Shield multi-turn absolute encoder battery fault|Operation setting|Power on again|0|0 to 1|(((
2548 -* 0:Detect multi-turn absolute encoder battery under voltage, and battery low voltage fault
2549 -* 1: (Not recommended) Shield multi-turn absolute motor battery failure alarm. Multi-turn absolute application may cause mechanical fault, only multi-turn absolute encoder motors is used as single-turn absolute
2554 +0:Detect multi-turn absolute encoder battery under voltage, and battery low voltage fault
2555 +
2556 +1: (Not recommended) Shield multi-turn absolute motor battery failure alarm. Multi-turn absolute application may cause mechanical fault, only multi-turn absolute encoder motors is used as single-turn absolute
2550 2550  )))|-
2551 2551  
2552 2552  This function is permitted when a multi-turn absolute encoder motor is used as a single-turn absolute and when it is confirmed that no mechanical failure will occur.