Changes for page 06 Operation
Last modified by Iris on 2025/07/23 15:49
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -2221,8 +2221,9 @@ 2221 2221 )))|((( 2222 2222 Effective immediately 2223 2223 )))|0|0 to 1|((( 2224 -* 0: internal value 2225 -* 1: AI_1 analog input (not supported by VD2F and VD2L) 2224 +0: internal value 2225 + 2226 +1: AI_1 analog input (not supported by VD2F and VD2L) 2226 2226 )))|- 2227 2227 2228 2228 * Torque limit source is internal torque instruction (P01-14=0) ... ... @@ -2299,7 +2299,7 @@ 2299 2299 Operation setting 2300 2300 )))|((( 2301 2301 Effective immediately 2302 -)))|3000|0 to 5000|(((2303 +)))|3000|0 to 6000|((( 2303 2303 Forward torque 2304 2304 2305 2305 limit in torque mode ... ... @@ -2312,7 +2312,7 @@ 2312 2312 Operation setting 2313 2313 )))|((( 2314 2314 Effective immediately 2315 -)))|3000|0 to 5000|(((2316 +)))|3000|0 to 6000|((( 2316 2316 Reverse torque 2317 2317 2318 2318 limit in torque mode