... ... @@ -2300,7 +2300,7 @@
2300 2300  Operation setting
2301 2301  )))|(((
2302 2302  Effective immediately
2303 -)))|3000|0 to 5000|(((
2303 +)))|3000|0 to 6000|(((
2304 2304  Forward torque
2305 2305  
2306 2306  limit in torque mode
... ... @@ -2313,7 +2313,7 @@
2313 2313  Operation setting
2314 2314  )))|(((
2315 2315  Effective immediately
2316 -)))|3000|0 to 5000|(((
2316 +)))|3000|0 to 6000|(((
2317 2317  Reverse torque
2318 2318  
2319 2319  limit in torque mode
... ... @@ -2398,13 +2398,18 @@
2398 2398  )))|(((
2399 2399  Shutdown setting
2400 2400  )))|1|(% style="width:90px" %)1 to 6|(% style="width:273px" %)(((
2401 -* 1: Position control
2402 -* 2: Speed control
2403 -* 3: Torque control
2404 -* 4: Position/speed mixed control
2405 -* 5: Position/torque mixed control
2406 -* 6: Speed/torque mixed control
2401 +1: Position control
2407 2407  
2403 +2: Speed control
2404 +
2405 +3: Torque control
2406 +
2407 +4: Position/speed mixed control
2408 +
2409 +5: Position/torque mixed control
2410 +
2411 +6: Speed/torque mixed control
2412 +
2408 2408  **VD2L drive P0-01 setting range: 1-3, not support mixed mode**
2409 2409  )))|-
2410 2410  
... ... @@ -2546,8 +2546,9 @@
2546 2546  **time**
2547 2547  )))|=**Default value**|=**Range**|=**Definition**|=**Unit**
2548 2548  |=P00-30|Shield multi-turn absolute encoder battery fault|Operation setting|Power on again|0|0 to 1|(((
2549 -* 0:Detect multi-turn absolute encoder battery under voltage, and battery low voltage fault
2550 -* 1: (Not recommended) Shield multi-turn absolute motor battery failure alarm. Multi-turn absolute application may cause mechanical fault, only multi-turn absolute encoder motors is used as single-turn absolute
2554 +0:Detect multi-turn absolute encoder battery under voltage, and battery low voltage fault
2555 +
2556 +1: (Not recommended) Shield multi-turn absolute motor battery failure alarm. Multi-turn absolute application may cause mechanical fault, only multi-turn absolute encoder motors is used as single-turn absolute
2551 2551  )))|-
2552 2552  
2553 2553  This function is permitted when a multi-turn absolute encoder motor is used as a single-turn absolute and when it is confirmed that no mechanical failure will occur.
... ... @@ -2692,8 +2692,9 @@
2692 2692  
2693 2693  VDI_1 input level:
2694 2694  
2695 -* 0: low level
2696 -* 1: high level
2701 +0: Low level
2702 +
2703 +1: High level
2697 2697  )))|-
2698 2698  |=P13-2|Virtual VDI_2 input value|Operation setting|Effective immediately|0|0 to 1|(((
2699 2699  When P06-07 is set to 1, DI_2 channel logic is control by this function code.
... ... @@ -2700,8 +2700,9 @@
2700 2700  
2701 2701  VDI_2 input level:
2702 2702  
2703 -* 0: low level
2704 -* 1: high level
2710 +0: Low level
2711 +
2712 +1: High level
2705 2705  )))|-
2706 2706  |=P13-3|Virtual VDI_3 input value|Operation setting|Effective immediately|0|0 to 1|(((
2707 2707  When P06-10 is set to 1, DI_3 channel logic is control by this function code.
... ... @@ -2708,8 +2708,9 @@
2708 2708  
2709 2709  VDI_3 input level:
2710 2710  
2711 -* 0: low level
2712 -* 1: high level
2719 +0: Low level
2720 +
2721 +1: High level
2713 2713  )))|-
2714 2714  |=P13-4|Virtual VDI_4 input value|Operation setting|Effective immediately|0|0 to 1|(((
2715 2715  When P06-13 is set to 1, DI_4 channel logic is control by this function code.
... ... @@ -2716,40 +2716,53 @@
2716 2716  
2717 2717  VDI_4 input level:
2718 2718  
2719 -* 0: low level
2720 -* 1: high level
2728 +0: Low level
2729 +
2730 +1: High level
2721 2721  )))|-
2722 -|=P13-05☆|Virtual VDI_5 input value|Operation setting|Effective immediately|0|0 to 1|(((
2732 +|=P13-05(((
2733 +★
2734 +)))|Virtual VDI_5 input value|Operation setting|Effective immediately|0|0 to 1|(((
2723 2723  When P06-16 is set to 1, DI_5 channel logic is control by this function code.
2724 2724  
2725 2725  VDI_5 input level:
2726 2726  
2727 -* 0: low level
2728 -* 1: high level
2739 +0: Low level
2740 +
2741 +1: High level
2729 2729  )))|-
2730 -|=P13-06☆|Virtual VDI_6 input value|Operation setting|Effective immediately|0|0 to 1|(((
2743 +|=P13-06(((
2744 +★
2745 +)))|Virtual VDI_6 input value|Operation setting|Effective immediately|0|0 to 1|(((
2731 2731  When P06-19 is set to 1, DI_6 channel logic is control by this function code.
2732 2732  
2733 2733  VDI_6 input level:
2734 2734  
2735 -* 0: low level
2736 -* 1: high level
2750 +0: Low level
2751 +
2752 +1: High level
2737 2737  )))|-
2738 -|=P13-07☆|Virtual VDI_7 input value|Operation setting|Effective immediately|0|0 to 1|(((
2754 +|=P13-07(((
2755 +★
2756 +)))|Virtual VDI_7 input value|Operation setting|Effective immediately|0|0 to 1|(((
2739 2739  When P06-22 is set to 1, DI_7 channel logic is control by this function code.
2740 2740  
2741 2741  VDI_7 input level:
2742 2742  
2743 -* 0: low level
2744 -* 1: high level
2761 +0: Low level
2762 +
2763 +1: High level
2745 2745  )))|-
2746 -|=P13-08☆|Virtual VDI_8 input value|Operation setting|Effective immediately|0|0 to 1|(((
2765 +|=P13-08(((
2766 +★
2767 +)))|Virtual VDI_8 input value|Operation setting|Effective immediately|0|0 to 1|(((
2747 2747  When P06-25 is set to 1, DI_8 channel logic is control by this function code.
2748 2748  
2749 2749  VDI_8 input level:
2750 2750  
2751 -* 0: low level
2752 -* 1: high level
2772 +0: Low level
2773 +
2774 +1: High level
2753 2753  )))|-
2754 2754  
2755 2755  Table 6-57 Virtual VDI parameters
... ... @@ -2756,7 +2756,7 @@
2756 2756  
2757 2757  (% class="box infomessage" %)
2758 2758  (((
2759 -✎**Note: **“” means VD2F servo drive does not support the function code .
2781 +✎**Note: **“” means VD2F and VD2L servo drive does not support the function code .
2760 2760  )))
2761 2761  
2762 2762  == Port filtering time ==
... ... @@ -2790,26 +2790,30 @@
2790 2790  |=P13-11|Communication VDO_1 output value|Operation setting|Effective immediately|0|0 to 1|(((
2791 2791  VDO_1 output level:
2792 2792  
2793 -* 0: low level
2794 -* 1: high level
2815 +0: Low level
2816 +
2817 +1: High level
2795 2795  )))|-
2796 2796  |=P13-12|Communication VDO_2 output value|Operation setting|Effective immediately|0|0 to 1|(((
2797 2797  VDO_2 output level:
2798 2798  
2799 -* 0: low level
2800 -* 1: high level
2822 +0: Low level
2823 +
2824 +1: High level
2801 2801  )))|-
2802 2802  |=P13-13|Communication VDO_3 output value|Operation setting|Effective immediately|0|0 to 1|(((
2803 2803  VDO_3 output level:
2804 2804  
2805 -* 0: low level
2806 -* 1: high level
2829 +0: Low level
2830 +
2831 +1: High level
2807 2807  )))|-
2808 2808  |=P13-14|Communication VDO_4 output value|Operation setting|Effective immediately|0|0 to 1|(((
2809 2809  VDO_4 output level:
2810 2810  
2811 -* 0: low level
2812 -* 1: high level
2836 +0: Low level
2837 +
2838 +1: High level
2813 2813  )))|-
2814 2814  
2815 2815  Table 6-59 Communication control DO function parameters