Changes for page 06 Operation
Last modified by Iris on 2025/07/23 15:49
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -2878,3 +2878,924 @@ 2878 2878 ((( 2879 2879 ✎**Note:** It is advised to configure function codes for DO terminals in sequence to avoid errors. Please use the shielded overload protection fault detection function with caution, otherwise it will cause burn out the motor. 2880 2880 ))) 2881 + 2882 + 2883 + 2884 +6.8 Homing Model (HM) 2885 + 2886 +The homing mode is used to find the mechanical origin and locate the positional relationship between the mechanical origin and the mechanical zero. 2887 + 2888 +Mechanical homing: A mechanically fixed position may correspond to a certain defined homing switch, or may correspond to the motor Z signal. 2889 + 2890 +Mechanical zero point: Mechanically absolute 0 position. 2891 + 2892 +After the homing, the stop position of the motor is the mechanical homing. By setting P10-08, the relationship between the mechanical homing and the mechanical zero can be set: 2893 + 2894 +Mechanical homing = Mechanical zero +P10-08 (homing offset) 2895 + 2896 +When P10-08=0, the mechanical homing coincides with the mechanical zero. 2897 + 2898 + 2899 +6.8.1 Control block diagram 2900 + 2901 +[[image:file:///C:\Users\Administrator\AppData\Local\Temp\ksohtml22584\wps1.png]]Figure 6-53 Homing mode control block diagram 2902 + 2903 + 2904 + 2905 + 2906 +6.8. 2 Homing mode related function codes 2907 + 2908 +|Function code|Name|((( 2909 +Setting 2910 + 2911 +method 2912 +)))|((( 2913 +Effective 2914 + 2915 +time 2916 +)))|Default|Range|Definition|Unit 2917 +|P01-39.|Homing start mode|((( 2918 +Stop 2919 + 2920 +settings 2921 +)))|((( 2922 +Immediately 2923 + 2924 +effective 2925 +)))|0|0 to 2|((( 2926 +0: Close 2927 + 2928 +1: The servo is powered ON and started after the first ON 2929 + 2930 +2: DI enable 2931 +)))|- 2932 + 2933 + 2934 +|Function code|Name|((( 2935 +Setting 2936 + 2937 +method 2938 +)))|((( 2939 +Effective 2940 + 2941 +time 2942 +)))|Default|Range|Definition|Unit 2943 +|P01-40|Homing mode|((( 2944 +Stop 2945 + 2946 +settings 2947 +)))|((( 2948 +Immediately 2949 + 2950 +effective 2951 +)))|0|0 to 35|((( 2952 +0 ~~ 35 Homing mode; 2953 + 2954 +✎Note: VD2 currently does not support 15, 16, 31, 32 modes 2955 +)))|- 2956 + 2957 +|Function code|Name|((( 2958 +Setting 2959 + 2960 +method 2961 +)))|((( 2962 +Effective 2963 + 2964 +time 2965 +)))|Default|Range|Definition|Unit 2966 +|P01-41|High-speed search deceleration point signal velocity|((( 2967 +Running 2968 + 2969 +settings 2970 +)))|((( 2971 +Immediately 2972 + 2973 +effective 2974 +)))|300|1 to 3000|High-speed search deceleration point signal velocity in homing mode|rpm 2975 + 2976 +|Function code|Name|((( 2977 +Setting 2978 + 2979 +method 2980 +)))|((( 2981 +Effective 2982 + 2983 +time 2984 +)))|Default|Range|Definition|Unit 2985 +|P01-42〇|Low speed search homing signal speed|((( 2986 +Running 2987 + 2988 +settings 2989 +)))|((( 2990 +Immediately 2991 + 2992 +effective 2993 +)))|60|1 to 300|Low-speed search origin signal velocity in homing mode|rpm 2994 + 2995 +|Function code|Name|((( 2996 +Setting 2997 + 2998 +method 2999 +)))|((( 3000 +Effective 3001 + 3002 +time 3003 +)))|Default|Range|Definition|Unit 3004 +|P01-43〇|Homing acceleration and deceleration|((( 3005 +Running 3006 + 3007 +settings 3008 +)))|((( 3009 +Immediately 3010 + 3011 +effective 3012 +)))|50|1to1000|((( 3013 +Acceleration and deceleration in homing mode 3014 + 3015 +Time for speed acceleration from 0 to 1000rpm 3016 +)))|ms 3017 + 3018 +|Function code|Name|((( 3019 +Setting 3020 + 3021 +method 3022 +)))|((( 3023 +Effective 3024 + 3025 +time 3026 +)))|Default|Range|Definition|Unit 3027 +|P01-44〇|Homing timeout limited time|((( 3028 +Running 3029 + 3030 +settings 3031 +)))|((( 3032 +Immediately 3033 + 3034 +effective 3035 +)))|65535|100 to 65535|Homing timeout limited time|ms 3036 + 3037 +|Function code|Name|((( 3038 +Setting 3039 + 3040 +method 3041 +)))|((( 3042 +Effective 3043 + 3044 +time 3045 +)))|Default|Range|Definition|Unit 3046 +|P10-08〇|Multi-turn absolute encoder homing offset compensation|((( 3047 +Running 3048 + 3049 +settings 3050 +)))|((( 3051 +Immediately 3052 + 3053 +effective 3054 +)))|0|((( 3055 +-2147483647~~ 3056 + 3057 +2147483646 3058 +)))|((( 3059 +P10-08 multi-turn absolute encoder homing offset compensation is used in conjunction with U0-56 multi-turn absolute encoder current position. 3060 + 3061 +When P10-6 is set to 1, the value of U0-56 is updated to P10-8. 3062 +)))|- 3063 + 3064 + 3065 + 3066 + 3067 + 3068 + 3069 + 3070 +6.8.2 Introduction to homing method 3071 + 3072 +In the following figure, "H" represents P01-41 (high-speed search deceleration point signal speed), and "L" represents P01-42 (low-speed search homing signal speed). 3073 + 3074 + 3075 +(1) P01-40 =1 3076 + 3077 +Mechanical homing: Motor Z signal 3078 + 3079 +Deceleration point: Reverse limit switch (NOT) 3080 + 3081 +① The deceleration point signal is invalid when starting homing 3082 + 3083 +[[image:file:///C:\Users\Administrator\AppData\Local\Temp\ksohtml22584\wps2.png]] 3084 + 3085 +When it starts to homing, NOT=0, it starts to homing at a high speed in the reverse direction. After encountering the rising edge of NOT, it decelerates and reverses the direction, runs at a low speed in the forward direction, and stops at the first Z signal after encountering the falling edge of NOT. 3086 + 3087 + 3088 +② The deceleration point signal is valid when starting homing 3089 + 3090 +[[image:file:///C:\Users\Administrator\AppData\Local\Temp\ksohtml22584\wps3.png]] 3091 + 3092 +When starting to homing, NOT=1, it starts to homing at a direct forward low speed, and stops at the first Z signal after encountering the falling edge of NOT. 3093 + 3094 + 3095 + 3096 + 3097 + 3098 + 3099 +(2) P01-40=2 3100 + 3101 +Mechanical homing: Motor Z signal 3102 + 3103 +Deceleration point: Positive Limit Switch (POT) 3104 + 3105 +① The deceleration point signal is invalid when starting homing 3106 + 3107 +[[image:file:///C:\Users\Administrator\AppData\Local\Temp\ksohtml22584\wps4.png]] 3108 + 3109 +When it starts to homing, POT = 0, and it starts to homing at a forward high speed. After encountering the rising edge of POT, it decelerates and reverses, runs at a reverse low speed, and stops at the first Z signal after encountering the falling edge of POT. 3110 + 3111 + 3112 +② The deceleration point signal is valid when starting homing 3113 + 3114 +[[image:file:///C:\Users\Administrator\AppData\Local\Temp\ksohtml22584\wps5.png]] 3115 + 3116 +POT=1 when start homing, run at low speed directly in the reverse direction, and stops at the first Z signal after the falling edge of POT. 3117 + 3118 + 3119 + 3120 + 3121 + 3122 + 3123 + 3124 + 3125 + 3126 + 3127 + 3128 + 3129 + 3130 +(3) P01-40=3 3131 + 3132 +Mechanical homing: Motor Z signal 3133 + 3134 +Deceleration point: Home switch (HW) 3135 + 3136 +① The deceleration point signal is invalid when starting homing 3137 + 3138 +[[image:file:///C:\Users\Administrator\AppData\Local\Temp\ksohtml22584\wps6.png]] 3139 + 3140 +When it starts to homing, HW=0. It starts to homing at a forward high speed. After encountering the rising edge of HW, it decelerates and reverses the direction. It runs at a reverse low speed. After encountering the falling edge of HW, it continues to run, and then stops when encountering the first Z signal. 3141 + 3142 + 3143 +② The deceleration point signal is valid when starting homing 3144 + 3145 +[[image:file:///C:\Users\Administrator\AppData\Local\Temp\ksohtml22584\wps7.png]] 3146 + 3147 +When starting homing, HW=1, start homing at low speed in reverse directly, and stop at the first Z signal after encountering the falling edge of HW; 3148 + 3149 + 3150 + 3151 + 3152 + 3153 + 3154 + 3155 + 3156 + 3157 + 3158 + 3159 + 3160 + 3161 +(4) P01-40=4 3162 + 3163 +Mechanical homing: Motor Z signal 3164 + 3165 +Deceleration point: Home switch (HW) 3166 + 3167 +① The deceleration point signal is invalid when starting homing 3168 + 3169 +[[image:file:///C:\Users\Administrator\AppData\Local\Temp\ksohtml22584\wps8.png]] 3170 + 3171 +HW=0 when starting to homing, directly start to homing at low speed, and stop at the first Z signal after encountering the rising edge of HW; 3172 + 3173 + 3174 +② The deceleration point signal is valid when starting homing 3175 + 3176 +[[image:file:///C:\Users\Administrator\AppData\Local\Temp\ksohtml22584\wps9.jpg]] 3177 + 3178 + 3179 +When starting to homing, HW = 1, start to homing at a high speed in the reverse direction. After encountering the falling edge of HW, decelerate and reverse, run at a low speed in the forward direction, and stop at the first Z signal after encountering the rising edge of HW. 3180 + 3181 + 3182 + 3183 + 3184 + 3185 +(5) P01-40=5 3186 + 3187 +Mechanical homing: Motor Z signal 3188 + 3189 +Deceleration point: Home switch (HW) 3190 + 3191 +① The deceleration point signal is invalid when starting homing 3192 + 3193 +[[image:file:///C:\Users\Administrator\AppData\Local\Temp\ksohtml22584\wps10.png]] 3194 + 3195 +When it starts to homing, HW = 0, and it starts to homing at a reverse high speed. After encountering the rising edge of HW, it decelerates and reverses the direction, runs at a forward low speed, and stops at the first Z signal after encountering the falling edge of HW. 3196 + 3197 + 3198 +② The deceleration point signal is valid when starting homing 3199 + 3200 +[[image:file:///C:\Users\Administrator\AppData\Local\Temp\ksohtml22584\wps11.png]] 3201 + 3202 +When starting homing, HW=1, it will start homing directly at low speed, and the first Z signal after encountering the falling edge of HW will stop; 3203 + 3204 + 3205 + 3206 + 3207 + 3208 +(6) P01-40=6 3209 + 3210 +Mechanical homing: Motor Z signal 3211 + 3212 +Deceleration point: Home switch (HW) 3213 + 3214 +① The deceleration point signal is invalid when starting homing 3215 + 3216 +[[image:file:///C:\Users\Administrator\AppData\Local\Temp\ksohtml22584\wps12.png]] 3217 + 3218 +When starting to homing, HW=0, directly reverse low speed starts to homing, and the first Z signal stops after encountering the rising edge of HW; 3219 + 3220 + 3221 +② The deceleration point signal is valid when starting homing 3222 + 3223 +[[image:file:///C:\Users\Administrator\AppData\Local\Temp\ksohtml22584\wps13.png]] 3224 + 3225 +When starting to homing, HW = 1, start to homing at a forward high speed, after encountering the falling edge of HW, decelerate and reverse, run at a reverse low speed, and stop at the first Z signal after encountering the rising edge of HW. 3226 + 3227 + 3228 + 3229 + 3230 + 3231 +(7) P01-40=7 3232 + 3233 +Mechanical homing: Motor Z signal 3234 + 3235 +Deceleration point: Home switch (HW) 3236 + 3237 +① The deceleration point signal is invalid when starting homing, the forward limit switch is not encountered 3238 + 3239 +[[image:file:///C:\Users\Administrator\AppData\Local\Temp\ksohtml22584\wps14.png]] 3240 + 3241 +When it starts to homing, HW = 0, and it starts to homing at a forward high speed. If the limit switch is not encountered, after encountering the rising edge of HW, it decelerates and reverses the direction, and runs at a reverse low speed. The first Z signal after encountering the falling edge of HW stops. 3242 + 3243 + 3244 +When homing, the deceleration point signal is invalid and the forward limit switch is encountered 3245 + 3246 +[[image:file:///C:\Users\Administrator\AppData\Local\Temp\ksohtml22584\wps15.jpg]] 3247 + 3248 +When it starts to homing, HW = 0, and it starts to homing at a forward high speed. If it encounters a limit switch, it will automatically reverse and run at a reverse high speed. After encountering the rising edge of HW, it will slow down and continue to run at a reverse low speed. The first Z signal after the falling edge of HW will stop. 3249 + 3250 + 3251 +③ The deceleration point signal is valid when starting homing 3252 + 3253 +[[image:file:///C:\Users\Administrator\AppData\Local\Temp\ksohtml22584\wps16.png]] 3254 + 3255 +When starting homing, HW=1, then directly reverse the low speed to start homing, and stop the first Z signal after encountering the falling edge of HW; 3256 + 3257 + 3258 +(8) P01-40=8 3259 + 3260 +Mechanical homing: Motor Z signal 3261 + 3262 +Deceleration point: Home switch (HW) 3263 + 3264 +① The deceleration point signal is invalid when starting homing, the forward limit switch is not encountered 3265 + 3266 +[[image:file:///C:\Users\Administrator\AppData\Local\Temp\ksohtml22584\wps17.png]] 3267 + 3268 +When it starts to homing, HM-0 starts to homing at a forward high speed. If it does not encounter the limit switch, after encountering the rising edge of HW, slow down and reverse, and run at a reverse low speed. After encountering the falling edge of HW, reverse, run at a forward low speed, and stop at the first Z signal after encountering the rising edge of HW. 3269 + 3270 + 3271 +① The deceleration point signal is invalid when starting homing, the forward limit switch is encountered 3272 + 3273 +[[image:file:///C:\Users\Administrator\AppData\Local\Temp\ksohtml22584\wps18.png]] 3274 + 3275 +When it starts to homing, HW = 0, and it starts to homing at forward high speed. If it encounters a limit switch, it will automatically reverse and run at reverse high speed; After encountering the rising edge of HW, slow down and run at a reverse low speed; After encountering the falling edge of HW, reverse the direction, run at a forward low speed, and stop the first Z signal after encountering the rising edge of HW. 3276 + 3277 + 3278 +③ The deceleration point signal is valid when starting homing 3279 + 3280 +[[image:file:///C:\Users\Administrator\AppData\Local\Temp\ksohtml22584\wps19.png]] 3281 + 3282 +When starting to homing, HM-1 will directly reverse and start to return to zero at low speed. After encountering the falling edge of HW, it will reverse and run at forward low speed. The first Z signal after encountering the rising edge of HW will stop. 3283 + 3284 + 3285 + 3286 +(9) P01-40=9 3287 + 3288 +Mechanical homing: Motor Z signal 3289 + 3290 +Deceleration point: Home switch (HW) 3291 + 3292 +① The deceleration point signal is invalid when starting homing, the forward limit switch is not encountered 3293 + 3294 +[[image:file:///C:\Users\Administrator\AppData\Local\Temp\ksohtml22584\wps20.png]] 3295 + 3296 +When it starts to homing, HW=0, and it starts to homing at a forward high speed. If the limit switch is not encountered, after encountering the rising edge of HW, it decelerates and runs at a forward low speed; After encountering the falling edge of HW, reverse, run at a low speed in the reverse direction, and stop at the first Z signal after encountering the rising edge of HW. 3297 + 3298 + 3299 +① The deceleration point signal is invalid when starting homing, the forward limit switch is encountered 3300 + 3301 +[[image:file:///C:\Users\Administrator\AppData\Local\Temp\ksohtml22584\wps21.png]] 3302 + 3303 +When it starts to homing, HW = 0, and it starts to homing at a forward high speed. If it encounters a limit switch, it will automatically reverse and run at a reverse high speed. After encountering a rising edge of HW, it will slow down and reverse to resume forward operation. Running at a forward low speed, after encountering a falling edge of HW, it will reverse. During reverse low speed operation, the first Z signal after encountering a rising edge of HW will stop. 3304 + 3305 +③ The deceleration point signal is valid when starting homing 3306 + 3307 +[[image:file:///C:\Users\Administrator\AppData\Local\Temp\ksohtml22584\wps22.png]] 3308 + 3309 +When starting homing, HW=1 starts homing directly at forward low speed. After encountering the falling edge of HW, the first Z signal after encountering the rising edge of HW stops in reverse and reverse low speed operation; 3310 + 3311 + 3312 +(10) P01-40=10 3313 + 3314 +Mechanical homing: Motor Z signal 3315 + 3316 +Deceleration point: Home switch (HW) 3317 + 3318 +① The deceleration point signal is invalid when starting homing, the forward limit switch is not encountered 3319 + 3320 +[[image:file:///C:\Users\Administrator\AppData\Local\Temp\ksohtml22584\wps23.png]] 3321 + 3322 +When it starts to homing, HW = 0, and it starts to homing at a forward high speed. If the limit switch is not encountered, after encountering the rising edge of HW, slow down and run at a forward low speed. After encountering the falling edge of HW, continue to run at a forward low speed, and then the first Z signal encountered stops. 3323 + 3324 +When homing, the deceleration point signal is invalid and the forward limit switch is encountered 3325 + 3326 +[[image:file:///C:\Users\Administrator\AppData\Local\Temp\ksohtml22584\wps24.jpg]] 3327 + 3328 +When it starts to homing, HW = 0, and it starts to homing at a forward high speed. If it encounters a limit switch, it will automatically reverse and run at a reverse high speed. After encountering the rising edge of HW, it will slow down and reverse to resume forward operation. The first Z signal after the low speed encounters the falling edge of HW will stop. 3329 + 3330 + 3331 +③ The deceleration point signal is valid when starting homing 3332 + 3333 +[[image:file:///C:\Users\Administrator\AppData\Local\Temp\ksohtml22584\wps25.png]] 3334 + 3335 +When starting homing, HW=1, it will start homing directly at low speed, and the first Z signal after encountering the falling edge of HW will stop; 3336 + 3337 + 3338 +(11) P01-40=11 3339 + 3340 +Mechanical homing: Motor Z signal 3341 + 3342 +Deceleration point: Home switch (HW) 3343 + 3344 +① The deceleration point signal is invalid when starting homing, the reverse limit switch is not encountered 3345 + 3346 +[[image:file:///C:\Users\Administrator\AppData\Local\Temp\ksohtml22584\wps26.png]] 3347 + 3348 +When it starts to homing, HW=0, and it starts to homing at a reverse high speed. If the limit switch is not encountered, after encountering the rising edge of HW, it decelerates and reverses the direction, runs at a forward low speed, and stops at the first Z signal after encountering the falling edge of HW. 3349 + 3350 + 3351 +① The deceleration point signal is invalid when starting homing, the reverse limit switch is encountered 3352 + 3353 +[[image:file:///C:\Users\Administrator\AppData\Local\Temp\ksohtml22584\wps27.png]] 3354 + 3355 +When it starts to homing, HW=0, and it starts to homing at a reverse high speed. If it encounters a limit switch, it will automatically reverse and run at a forward high speed. After encountering a rising edge of HW, slow down and continue to run at a forward low speed. When encountering a falling edge of HW, the first Z signal after the edge stops. 3356 + 3357 +③ The deceleration point signal is valid when starting homing 3358 + 3359 +[[image:file:///C:\Users\Administrator\AppData\Local\Temp\ksohtml22584\wps28.png]] 3360 + 3361 +When starting homing, HW=1, it will start homing directly at low speed, and the first Z signal after encountering the falling edge of HW will stop; 3362 + 3363 + 3364 +(12) P01-40=12 3365 + 3366 +Mechanical homing: Motor Z signal 3367 + 3368 +Deceleration point: Home switch (HW) 3369 + 3370 +① The deceleration point signal is invalid when starting homing, the reverse limit switch is not encountered 3371 + 3372 +[[image:file:///C:\Users\Administrator\AppData\Local\Temp\ksohtml22584\wps29.png]] 3373 + 3374 +When it starts to homing, HW = 0, it starts to homing at a reverse high speed, and does not encounter a limit switch. After encountering the rising edge of HW, it decelerates and reverses, and runs at a forward low speed. After encountering the falling edge of HW, it reverses and runs at a reverse low speed, and stops at the first Z signal after encountering the rising edge of HW. 3375 + 3376 + 3377 + 3378 +① The deceleration point signal is invalid when starting homing, the reverse limit switch is encountered 3379 + 3380 +[[image:file:///C:\Users\Administrator\AppData\Local\Temp\ksohtml22584\wps30.png]] 3381 + 3382 +When it starts to homing, HW=0, it starts to homing at a reverse high speed, encounters a limit switch, automatically reverses, runs at a forward high speed, encounters a rising edge of HW, decelerates, runs at a forward low speed, encounters a falling edge of HW, reverses, runs at a reverse low speed, and stops at the first Z signal after encountering a rising edge of HW. 3383 + 3384 + 3385 +③ The deceleration point signal is valid when starting homing 3386 + 3387 +[[image:file:///C:\Users\Administrator\AppData\Local\Temp\ksohtml22584\wps31.png]] 3388 + 3389 +When starting to homing, HW = 1, it will directly start to homing at a forward low speed. After encountering the falling edge of HW, it will reverse and run at a reverse low speed. The first Z signal after encountering the rising edge of HW will stop. 3390 + 3391 +(13) P01-40=13 3392 + 3393 +Mechanical homing: Motor Z signal 3394 + 3395 +Deceleration point: Home switch (HW) 3396 + 3397 +① The deceleration point signal is invalid when starting homing, the reverse limit switch is not encountered 3398 + 3399 +[[image:file:///C:\Users\Administrator\AppData\Local\Temp\ksohtml22584\wps32.png]] 3400 + 3401 +When it starts to homing, HW=0, and it starts to homing at a reverse high speed. If it does not encounter the limit switch, after encountering the rising edge of HW, slow down and run at a reverse low speed. After encountering the falling edge of HW, reverse and run at a forward low speed, and stop at the first Z signal after encountering the rising edge of HW. 3402 + 3403 + 3404 +① The deceleration point signal is invalid when starting homing, the reverse limit switch is encountered 3405 + 3406 +[[image:file:///C:\Users\Administrator\AppData\Local\Temp\ksohtml22584\wps33.png]] 3407 + 3408 +When it starts to homing, HW=0, it starts to homing at reverse high speed, encounters the limit switch, automatically reverses, runs at forward high speed, after encountering the rising edge of HW, decelerates and runs in reverse low speed, and encounters the falling edge of HW when running at reverse low speed, the first Z signal after encountering the rising edge of HW stops. 3409 + 3410 +③ The deceleration point signal is valid when starting homing 3411 + 3412 +[[image:file:///C:\Users\Administrator\AppData\Local\Temp\ksohtml22584\wps34.png]] 3413 + 3414 +When starting homing, HW=1 starts homing directly at reverse low speed. After encountering the falling edge of HW, the first Z signal after encountering the rising edge of HW stops in reverse and forward low speed operation; 3415 + 3416 + 3417 +(14) P01-40=14 3418 + 3419 +Mechanical homing: Motor Z signal 3420 + 3421 +Deceleration point: Home switch (HW) 3422 + 3423 +① The deceleration point signal is invalid when starting homing, the reverse limit switch is not encountered 3424 + 3425 +[[image:file:///C:\Users\Administrator\AppData\Local\Temp\ksohtml22584\wps35.png]] 3426 + 3427 +When it starts to homing, HW=0, it starts to homing at reverse high speed, and does not encounter the limit switch. After encountering the rising edge of HW, it decelerates and runs at reverse low speed. After encountering the falling edge of HW, it continues to run at reverse low speed, and then the first Z signal encountered stops. 3428 + 3429 + 3430 +① The deceleration point signal is invalid when starting homing, the reverse limit switch is encountered 3431 + 3432 +[[image:file:///C:\Users\Administrator\AppData\Local\Temp\ksohtml22584\wps36.png]] 3433 + 3434 +When it starts to homing, HW = 0, it starts to homing at a reverse high speed, encounters a limit switch, automatically reverses, runs at a forward high speed, encounters a rising edge of HW, decelerates and runs in a reverse direction, and stops the first Z signal after encountering a falling edge of HW at a reverse low speed. 3435 + 3436 + 3437 +③ The deceleration point signal is valid when starting homing 3438 + 3439 +[[image:file:///C:\Users\Administrator\AppData\Local\Temp\ksohtml22584\wps37.png]] 3440 + 3441 +When starting homing, HW=1, then directly reverse the low speed to start homing, and stop the first Z signal after encountering the falling edge of HW; 3442 + 3443 + 3444 +(15) P01-40=17 3445 + 3446 +Mechanical homing: Negative overrun switch (NOT) 3447 + 3448 +Deceleration point: Negative overrun switch (NOT) 3449 + 3450 +① The deceleration point signal is invalid when starting homing 3451 + 3452 +[[image:file:///C:\Users\Administrator\AppData\Local\Temp\ksohtml22584\wps38.png]] 3453 + 3454 +When it starts to homing, NOT = 0, it starts to homing at a high speed in the reverse direction. After encountering the rising edge of NOT, it decelerates and reverses the direction, runs at a low speed in the forward direction, and stops after encountering the falling edge of NOT. 3455 + 3456 + 3457 +② The deceleration point signal is valid when starting homing 3458 + 3459 +[[image:file:///C:\Users\Administrator\AppData\Local\Temp\ksohtml22584\wps39.png]] 3460 + 3461 +When starting homing, NOT=1, start homing directly at low speed, and stop after encountering the falling edge of NOT. 3462 + 3463 + 3464 +(16) P01-40=18 3465 + 3466 +Mechanical homing: Positive overrun switch (POT) 3467 + 3468 +Deceleration point: Positive overrun switch (POT) 3469 + 3470 +① The deceleration point signal is invalid when starting homing 3471 + 3472 +[[image:file:///C:\Users\Administrator\AppData\Local\Temp\ksohtml22584\wps40.png]] 3473 + 3474 +When it starts to return to zero, POT=0, it starts to homing at a forward high speed, after encountering the rising edge of POT, it decelerates and reverses, runs at a reverse low speed, and stops after encountering the falling edge of POT. 3475 + 3476 + 3477 +② The deceleration point signal is valid when starting homing 3478 + 3479 +[[image:file:///C:\Users\Administrator\AppData\Local\Temp\ksohtml22584\wps41.png]] 3480 + 3481 +When starting homing, POT=1, start homing at low speed in reverse directly, and stop when encountering POT falling edge; 3482 + 3483 + 3484 + 3485 +(17) P01-40=19 3486 + 3487 +Mechanical homing: Home switch (HW) 3488 + 3489 +Deceleration point: Home switch (HW) 3490 + 3491 +① The deceleration point signal is invalid when starting homing 3492 + 3493 +[[image:file:///C:\Users\Administrator\AppData\Local\Temp\ksohtml22584\wps42.png]] 3494 + 3495 +When it starts to homing, HW=0, and it starts to homing at a forward high speed. After encountering the rising edge of HW, it decelerates and reverses the direction, runs at a reverse low speed, and stops when encountering the falling edge of HW. 3496 + 3497 + 3498 +② The deceleration point signal is valid when starting homing 3499 + 3500 +[[image:file:///C:\Users\Administrator\AppData\Local\Temp\ksohtml22584\wps43.png]] 3501 + 3502 +When starting homing, HW=1, start homing at low speed in reverse directly, and stop when encountering HW falling edge; 3503 + 3504 + 3505 +(18) P01-40=20 3506 + 3507 +Mechanical homing: Home switch (HW) 3508 + 3509 +Deceleration point: Home switch (HW) 3510 + 3511 +① The deceleration point signal is invalid when starting homing 3512 + 3513 +[[image:file:///C:\Users\Administrator\AppData\Local\Temp\ksohtml22584\wps44.png]] 3514 + 3515 +When starting to homing, HW=0, directly start to homing at low speed, and stop after encountering the rising edge of HW; 3516 + 3517 + 3518 +② The deceleration point signal is valid when starting homing 3519 + 3520 +[[image:file:///C:\Users\Administrator\AppData\Local\Temp\ksohtml22584\wps45.png]] 3521 + 3522 +When starting to homing, HW = 1, start to homing at a high speed in the reverse direction. After encountering the falling edge of HW, slow down and reverse the direction, run at a low speed in the forward direction, and stop when encountering the rising edge of HW. 3523 + 3524 + 3525 +(19) P01-40=21 3526 + 3527 +Mechanical homing: Home switch (HW) 3528 + 3529 +Deceleration point: Home switch (HW) 3530 + 3531 +① The deceleration point signal is invalid when starting homing 3532 + 3533 +[[image:file:///C:\Users\Administrator\AppData\Local\Temp\ksohtml22584\wps46.png]] 3534 + 3535 +When it starts to homing, HW=0, it starts to homing at a reverse high speed. After encountering the rising edge of HW, it decelerates and reverses the direction, runs at a forward low speed, and stops when encountering the falling edge of HW. 3536 + 3537 + 3538 +② The deceleration point signal is valid when starting homing 3539 + 3540 +[[image:file:///C:\Users\Administrator\AppData\Local\Temp\ksohtml22584\wps47.png]] 3541 + 3542 +When starting back to zero, HW=1, it will start homing directly at low speed, and stop after encountering the falling edge of HW; 3543 + 3544 + 3545 +(20) P01-40=22 3546 + 3547 +Mechanical homing: Home switch (HW) 3548 + 3549 +Deceleration point: Home switch (HW) 3550 + 3551 +① The deceleration point signal is invalid when starting homing 3552 + 3553 +[[image:file:///C:\Users\Administrator\AppData\Local\Temp\ksohtml22584\wps48.png]] 3554 + 3555 +When starting to homing, HW=0, directly reverse low speed starts to homing, and stops when encountering HW rising edge; 3556 + 3557 + 3558 +Deceleration point signal is valid when homing start 3559 + 3560 +[[image:file:///C:\Users\Administrator\AppData\Local\Temp\ksohtml22584\wps49.jpg]] 3561 + 3562 +When starting to homing, HW=1, start to homing at a forward high speed, after encountering the falling edge of HW, slow down and reverse, run at a reverse low speed, and stop when encountering the rising edge of HW. 3563 + 3564 + 3565 +(21) P01-40=23 3566 + 3567 +Mechanical homing: Home switch (HW) 3568 + 3569 +Deceleration point: Home switch (HW) 3570 + 3571 +① The deceleration point signal is invalid when starting homing, the forward limit switch is not encountered 3572 + 3573 +[[image:file:///C:\Users\Administrator\AppData\Local\Temp\ksohtml22584\wps50.png]] 3574 + 3575 +When it starts to homing, HW = 0, it starts to homing at a forward high speed, and does not encounter a limit switch. After encountering the rising edge of HW, it decelerates and reverses, runs at a reverse low speed, and stops when encountering the falling edge of HW. 3576 + 3577 + 3578 +① The deceleration point signal is invalid when starting homing, the forward limit switch is encountered 3579 + 3580 +[[image:file:///C:\Users\Administrator\AppData\Local\Temp\ksohtml22584\wps51.png]] 3581 + 3582 +When you start homing, HW = 0, start homing at a forward high speed. When encountering the limit switch, it will automatically reverse and run at a reverse high speed. After encountering the rising edge of HW, slow down, continue to run at reverse low speed, and stop when encountering the HW falling edge. 3583 + 3584 + 3585 + 3586 +③ The deceleration point signal is valid when starting homing 3587 + 3588 +[[image:file:///C:\Users\Administrator\AppData\Local\Temp\ksohtml22584\wps52.png]] 3589 + 3590 +When it starts to homing, HW=1, it starts to homing at a reverse low speed, and stops when it encounters the falling edge of HW. 3591 + 3592 + 3593 +(22) P01-40=24 3594 + 3595 +Mechanical homing: Home switch (HW) 3596 + 3597 +Deceleration point: Home switch (HW) 3598 + 3599 +① The deceleration point signal is invalid when starting homing, the forward limit switch is not encountered 3600 + 3601 +[[image:file:///C:\Users\Administrator\AppData\Local\Temp\ksohtml22584\wps53.png]] 3602 + 3603 +When it starts to homing, HW = 0, it starts to homing at a forward high speed, and does not encounter a limit switch. After encountering the rising edge of HW, it decelerates and reverses, and runs at a reverse low speed. After encountering the falling edge of HW, it reverses and runs at a forward low speed, and stops when encountering the rising edge of HW. 3604 + 3605 + 3606 +① The deceleration point signal is invalid when starting homing, the forward limit switch is encountered 3607 + 3608 +[[image:file:///C:\Users\Administrator\AppData\Local\Temp\ksohtml22584\wps54.png]] 3609 + 3610 +When it starts to homing, HW = 0, it starts to homing at forward high speed, encounters the limit switch, automatically reverses, runs at reverse high speed, encounters the rising edge of HW, decelerates and runs at reverse low speed, encounters the falling edge of HW, reverses, runs at forward low speed, and stops when encountering the rising edge of HW. 3611 + 3612 + 3613 +③ The deceleration point signal is valid when starting homing 3614 + 3615 +[[image:file:///C:\Users\Administrator\AppData\Local\Temp\ksohtml22584\wps55.png]] 3616 + 3617 +When starting with homing, HW = 1, it will directly reverse the low speed and start to homing. After encountering the falling edge of HW, it will reverse the direction and run at a forward low speed, and stop when encountering the rising edge of HW. 3618 + 3619 + 3620 +(23) P01-40=25 3621 + 3622 +Mechanical homing: Home switch (HW) 3623 + 3624 +Deceleration point: Home switch (HW) 3625 + 3626 +① The deceleration point signal is invalid when starting homing, the forward limit switch is not encountered 3627 + 3628 +[[image:file:///C:\Users\Administrator\AppData\Local\Temp\ksohtml22584\wps56.png]] 3629 + 3630 +When it starts to homing, HW=0, it starts to homing at a forward high speed, and does not encounter a limit switch. After encountering the rising edge of HW, it decelerates and runs at a forward low speed. After encountering the falling edge of HW, it reverses and runs at a reverse low speed, and stops when encountering the rising edge of HW. 3631 + 3632 + 3633 +① The deceleration point signal is invalid when starting homing, the forward limit switch is encountered 3634 + 3635 +[[image:file:///C:\Users\Administrator\AppData\Local\Temp\ksohtml22584\wps57.png]] 3636 + 3637 +When it starts to homing, HW=0, it starts to homing at forward high speed, encounters the limit switch, automatically reverses, and runs at reverse high speed. After encountering the rising edge of HW, decelerate and reverse to resume forward operation. After encountering the falling edge of HW at forward low speed, reverse. When running at reverse low speed, stop when encountering the rising edge of HW. 3638 + 3639 + 3640 +③ The deceleration point signal is valid when starting homing 3641 + 3642 +[[image:file:///C:\Users\Administrator\AppData\Local\Temp\ksohtml22584\wps58.png]] 3643 + 3644 +When starting homing, when HW=1, it starts to homing directly at low speed in the forward direction. After encountering the falling edge of HW, it stops at the rising edge of HW in the reverse low speed operation 3645 + 3646 + 3647 +(24) P01-40=26 3648 + 3649 +Mechanical homing: Home switch (HW) 3650 + 3651 +Deceleration point: Home switch (HW) 3652 + 3653 +① The deceleration point signal is invalid when starting homing, the forward limit switch is not encountered 3654 + 3655 +[[image:file:///C:\Users\Administrator\AppData\Local\Temp\ksohtml22584\wps59.png]] 3656 + 3657 +When it starts to homing, HW=0, it starts to homing at a forward high speed, and does not encounter a limit switch. After encountering the rising edge of HW, it decelerates, runs at a forward low speed, and stops when encountering the falling edge of HW. 3658 + 3659 + 3660 +① The deceleration point signal is invalid when starting homing, the forward limit switch is encountered 3661 + 3662 +[[image:file:///C:\Users\Administrator\AppData\Local\Temp\ksohtml22584\wps60.png]] 3663 + 3664 +When it starts to homing, HW=0, it starts to homing at forward high speed, encounters the limit switch, automatically reverses, and runs at reverse high speed. After encountering the rising edge of HW, decelerates and reverses to resume forward operation, and stops when encountering the falling edge of HW at forward low speed. 3665 + 3666 + 3667 +③ The deceleration point signal is valid when starting homing 3668 + 3669 +[[image:file:///C:\Users\Administrator\AppData\Local\Temp\ksohtml22584\wps61.png]] 3670 + 3671 +When starting homing, HW=1, it will start homing directly at low speed, and stop when encountering HW falling edge; 3672 + 3673 + 3674 +(25) P01-40=27 3675 + 3676 +Mechanical homing: Home switch (HW) 3677 + 3678 +Deceleration point: Home switch (HW) 3679 + 3680 +① The deceleration point signal is invalid when starting homing, the reverse limit switch is not encountered 3681 + 3682 +[[image:file:///C:\Users\Administrator\AppData\Local\Temp\ksohtml22584\wps62.png]] 3683 + 3684 +When it starts to homing, HW=0, it starts to homing at a reverse high speed, and does not encounter a limit switch. After encountering the rising edge of HW, it decelerates and reverses the direction, runs at a forward low speed, and stops when encountering the falling edge of HW. 3685 + 3686 + 3687 +① The deceleration point signal is invalid when starting homing, the reverse limit switch is encountered 3688 + 3689 +[[image:file:///C:\Users\Administrator\AppData\Local\Temp\ksohtml22584\wps63.png]] 3690 + 3691 +When it starts to homing, HW=0, it starts to homing at a reverse high speed. When it encounters a limit switch, it automatically reverses and runs at a forward high speed. When it encounters a rising edge of HW, it decelerates and continues to run at a forward low speed. When it encounters a falling edge of HW, it stops. 3692 + 3693 + 3694 +③ The deceleration point signal is valid when starting homing 3695 + 3696 +[[image:file:///C:\Users\Administrator\AppData\Local\Temp\ksohtml22584\wps64.png]] 3697 + 3698 +When starting homing, HW=1, it will start homing directly at low speed, and stop when encountering HW falling edge; 3699 + 3700 + 3701 +(26) P01-40=28 3702 + 3703 +Mechanical homing: Home switch (HW) 3704 + 3705 +Deceleration point: Home switch (HW) 3706 + 3707 +① The deceleration point signal is invalid when starting homing, the reverse limit switch is not encountered 3708 + 3709 +[[image:file:///C:\Users\Administrator\AppData\Local\Temp\ksohtml22584\wps65.png]] 3710 + 3711 +When it starts to homing, HW=0, it starts to homing at a reverse high speed, and does not encounter a limit switch. After encountering the rising edge of HW, it decelerates and reverses, and runs at a forward low speed. After encountering the falling edge of HW, it reverses and runs at a reverse low speed, and stops when encountering the rising edge of HW. 3712 + 3713 + 3714 +① The deceleration point signal is invalid when starting homing, the reverse limit switch is encountered 3715 + 3716 +[[image:file:///C:\Users\Administrator\AppData\Local\Temp\ksohtml22584\wps66.png]] 3717 + 3718 +When it starts to homing, HW=0, it starts to homing at a reverse high speed. When encountering a limit switch, it automatically reverses and runs at a forward high speed. When encountering a rising edge of HW, it decelerates and runs at a forward low speed. When encountering a falling edge of HW, it reverses and runs at a reverse low speed. When encountering a rising edge of HW, it stops. 3719 + 3720 + 3721 +③ The deceleration point signal is valid when starting homing 3722 + 3723 +[[image:file:///C:\Users\Administrator\AppData\Local\Temp\ksohtml22584\wps67.png]] 3724 + 3725 +When starting with homing, HW = 1, it will directly start to homing at a forward low speed. After encountering the falling edge of HW, it will reverse and run at a reverse low speed. When encountering the rising edge of HW, it will stop. 3726 + 3727 + 3728 +(27) P01-40=29 3729 + 3730 +Mechanical homing: Home switch (HW) 3731 + 3732 +Deceleration point: Home switch (HW) 3733 + 3734 +① The deceleration point signal is invalid when starting homing, the reverse limit switch is not encountered 3735 + 3736 +[[image:file:///C:\Users\Administrator\AppData\Local\Temp\ksohtml22584\wps68.png]] 3737 + 3738 +When it starts to homing, HW = 0, it starts to homing at a reverse high speed, and does not encounter a limit switch. After encountering the rising edge of HW, it decelerates and runs at a reverse low speed. After encountering the falling edge of HW, it reverses and runs at a forward low speed, and stops when encountering the rising edge of HW. 3739 + 3740 + 3741 +① The deceleration point signal is invalid when starting homing, the reverse limit switch is encountered 3742 + 3743 +[[image:file:///C:\Users\Administrator\AppData\Local\Temp\ksohtml22584\wps69.png]] 3744 + 3745 +When it starts to homing, HW=0, it starts to homing at a reverse high speed. When it encounters a limit switch, it automatically reverses and runs at a forward high speed. After encountering a rising edge of HW, it decelerates and runs in a reverse low speed. After encountering a falling edge of HW, it reverses. When running at a forward low speed, it stops when it encounters a rising edge of HW. 3746 + 3747 +③ The deceleration point signal is valid when starting homing 3748 + 3749 +[[image:file:///C:\Users\Administrator\AppData\Local\Temp\ksohtml22584\wps70.png]] 3750 + 3751 +When starting homing, when HW=1, it starts to homing directly at low speed in reverse direction. After encountering the falling edge of HW, it stops when running at low speed in reverse direction and forward direction and encountering the rising edge of HW 3752 + 3753 + 3754 +(28) P01-40=30 3755 + 3756 +Mechanical homing: Home switch (HW) 3757 + 3758 +Deceleration point: Home switch (HW) 3759 + 3760 +① The deceleration point signal is invalid when starting homing, the reverse limit switch is not encountered 3761 + 3762 +[[image:file:///C:\Users\Administrator\AppData\Local\Temp\ksohtml22584\wps71.png]] 3763 + 3764 +When it starts to homing, HW=0, it starts to homing at reverse high speed, and does not encounter the limit switch. After encountering the rising edge of HW, it decelerates, runs at reverse low speed, and stops when encountering the falling edge of HW. 3765 + 3766 + 3767 +① The deceleration point signal is invalid when starting homing, the reverse limit switch is encountered 3768 + 3769 +[[image:file:///C:\Users\Administrator\AppData\Local\Temp\ksohtml22584\wps72.png]] 3770 + 3771 +When it starts to homing, HW=0, it starts to homing at a reverse high speed. When it encounters a limit switch, it automatically reverses and runs at a forward high speed. When it encounters a rising edge of HW, it decelerates and runs in a reverse low speed. When it encounters a falling edge of HW, it stops. 3772 + 3773 + 3774 +③ The deceleration point signal is valid when starting homing 3775 + 3776 +[[image:file:///C:\Users\Administrator\AppData\Local\Temp\ksohtml22584\wps73.png]] 3777 + 3778 +When starting homing, HW=1, start homing at low speed in reverse directly, and stop when encountering HW falling edge; 3779 + 3780 + 3781 +(29) P01-40=33 and P01-40=34 3782 + 3783 +Mechanical homing: Z signal. 3784 + 3785 +Deceleration point: None 3786 + 3787 +Homing mode 33: Reverse low speed operation, stop the first Z signal encountered 3788 + 3789 +Homing mode 34: running at low speed in forward direction, stopping the first Z signal encountered 3790 + 3791 +[[image:file:///C:\Users\Administrator\AppData\Local\Temp\ksohtml22584\wps74.png]] 3792 + 3793 + 3794 +(30) P01-40=35 3795 + 3796 +Homing mode 35, taking the current position as the mechanical homing, after triggering the homing (P01-39: 0x00→0x01/0x00 → 0x02); 3797 + 3798 +After the homing is completed, according to the set value of P10-08 (homing bias compensation), P10-06 (encoder multi-turn reset operation) is executed. 3799 + 3800 + 3801 +