2878 2878  (((
2879 2879  ✎**Note:** It is advised to configure function codes for DO terminals in sequence to avoid errors. Please use the shielded overload protection fault detection function with caution, otherwise it will cause burn out the motor.
2880 2880  )))
2881 +
2882 +
2883 +
2884 +6.8 Homing Model (HM)
2885 +
2886 +The homing mode is used to find the mechanical origin and locate the positional relationship between the mechanical origin and the mechanical zero.
2887 +
2888 +Mechanical homing: A mechanically fixed position may correspond to a certain defined homing switch, or may correspond to the motor Z signal.
2889 +
2890 +Mechanical zero point: Mechanically absolute 0 position.
2891 +
2892 +After the homing, the stop position of the motor is the mechanical homing. By setting P10-08, the relationship between the mechanical homing and the mechanical zero can be set:
2893 +
2894 +Mechanical homing = Mechanical zero +P10-08 (homing offset)
2895 +
2896 +When P10-08=0, the mechanical homing coincides with the mechanical zero.
2897 +
2898 +
2899 +6.8.1 Control block diagram
2900 +
2901 +[[image:file:///C:\Users\Administrator\AppData\Local\Temp\ksohtml22584\wps1.png]]Figure 6-53 Homing mode control block diagram
2902 +
2903 +
2904 +
2905 +
2906 +6.8. 2 Homing mode related function codes
2907 +
2908 +|Function code|Name|(((
2909 +Setting
2910 +
2911 +method
2912 +)))|(((
2913 +Effective
2914 +
2915 +time
2916 +)))|Default|Range|Definition|Unit
2917 +|P01-39.|Homing start mode|(((
2918 +Stop
2919 +
2920 +settings
2921 +)))|(((
2922 +Immediately
2923 +
2924 +effective
2925 +)))|0|0 to 2|(((
2926 +0: Close
2927 +
2928 +1: The servo is powered ON and started after the first ON
2929 +
2930 +2: DI enable
2931 +)))|-
2932 +
2933 +
2934 +|Function code|Name|(((
2935 +Setting
2936 +
2937 +method
2938 +)))|(((
2939 +Effective
2940 +
2941 +time
2942 +)))|Default|Range|Definition|Unit
2943 +|P01-40|Homing mode|(((
2944 +Stop
2945 +
2946 +settings
2947 +)))|(((
2948 +Immediately
2949 +
2950 +effective
2951 +)))|0|0 to 35|(((
2952 +0 ~~ 35 Homing mode;
2953 +
2954 +✎Note: VD2 currently does not support 15, 16, 31, 32 modes
2955 +)))|-
2956 +
2957 +|Function code|Name|(((
2958 +Setting
2959 +
2960 +method
2961 +)))|(((
2962 +Effective
2963 +
2964 +time
2965 +)))|Default|Range|Definition|Unit
2966 +|P01-41|High-speed search deceleration point signal velocity|(((
2967 +Running
2968 +
2969 +settings
2970 +)))|(((
2971 +Immediately
2972 +
2973 +effective
2974 +)))|300|1 to 3000|High-speed search deceleration point signal velocity in homing mode|rpm
2975 +
2976 +|Function code|Name|(((
2977 +Setting
2978 +
2979 +method
2980 +)))|(((
2981 +Effective
2982 +
2983 +time
2984 +)))|Default|Range|Definition|Unit
2985 +|P01-42〇|Low speed search homing signal speed|(((
2986 +Running
2987 +
2988 +settings
2989 +)))|(((
2990 +Immediately
2991 +
2992 +effective
2993 +)))|60|1 to 300|Low-speed search origin signal velocity in homing mode|rpm
2994 +
2995 +|Function code|Name|(((
2996 +Setting
2997 +
2998 +method
2999 +)))|(((
3000 +Effective
3001 +
3002 +time
3003 +)))|Default|Range|Definition|Unit
3004 +|P01-43〇|Homing acceleration and deceleration|(((
3005 +Running
3006 +
3007 +settings
3008 +)))|(((
3009 +Immediately
3010 +
3011 +effective
3012 +)))|50|1to1000|(((
3013 +Acceleration and deceleration in homing mode
3014 +
3015 +Time for speed acceleration from 0 to 1000rpm
3016 +)))|ms
3017 +
3018 +|Function code|Name|(((
3019 +Setting
3020 +
3021 +method
3022 +)))|(((
3023 +Effective
3024 +
3025 +time
3026 +)))|Default|Range|Definition|Unit
3027 +|P01-44〇|Homing timeout limited time|(((
3028 +Running
3029 +
3030 +settings
3031 +)))|(((
3032 +Immediately
3033 +
3034 +effective
3035 +)))|65535|100 to 65535|Homing timeout limited time|ms
3036 +
3037 +|Function code|Name|(((
3038 +Setting
3039 +
3040 +method
3041 +)))|(((
3042 +Effective
3043 +
3044 +time
3045 +)))|Default|Range|Definition|Unit
3046 +|P10-08〇|Multi-turn absolute encoder homing offset compensation|(((
3047 +Running
3048 +
3049 +settings
3050 +)))|(((
3051 +Immediately
3052 +
3053 +effective
3054 +)))|0|(((
3055 +-2147483647~~
3056 +
3057 +2147483646
3058 +)))|(((
3059 +P10-08 multi-turn absolute encoder homing offset compensation is used in conjunction with U0-56 multi-turn absolute encoder current position.
3060 +
3061 +When P10-6 is set to 1, the value of U0-56 is updated to P10-8.
3062 +)))|-
3063 +
3064 +
3065 +
3066 +
3067 +
3068 +
3069 +
3070 +6.8.2 Introduction to homing method
3071 +
3072 +In the following figure, "H" represents P01-41 (high-speed search deceleration point signal speed), and "L" represents P01-42 (low-speed search homing signal speed).
3073 +
3074 +
3075 +(1) P01-40 =1
3076 +
3077 +Mechanical homing: Motor Z signal
3078 +
3079 +Deceleration point: Reverse limit switch (NOT)
3080 +
3081 +① The deceleration point signal is invalid when starting homing
3082 +
3083 +[[image:file:///C:\Users\Administrator\AppData\Local\Temp\ksohtml22584\wps2.png]]
3084 +
3085 +When it starts to homing, NOT=0, it starts to homing at a high speed in the reverse direction. After encountering the rising edge of NOT, it decelerates and reverses the direction, runs at a low speed in the forward direction, and stops at the first Z signal after encountering the falling edge of NOT.
3086 +
3087 +
3088 +② The deceleration point signal is valid when starting homing
3089 +
3090 +[[image:file:///C:\Users\Administrator\AppData\Local\Temp\ksohtml22584\wps3.png]]
3091 +
3092 +When starting to homing, NOT=1, it starts to homing at a direct forward low speed, and stops at the first Z signal after encountering the falling edge of NOT.
3093 +
3094 +
3095 +
3096 +
3097 +
3098 +
3099 +(2) P01-40=2
3100 +
3101 +Mechanical homing: Motor Z signal
3102 +
3103 +Deceleration point: Positive Limit Switch (POT)
3104 +
3105 +① The deceleration point signal is invalid when starting homing
3106 +
3107 +[[image:file:///C:\Users\Administrator\AppData\Local\Temp\ksohtml22584\wps4.png]]
3108 +
3109 +When it starts to homing, POT = 0, and it starts to homing at a forward high speed. After encountering the rising edge of POT, it decelerates and reverses, runs at a reverse low speed, and stops at the first Z signal after encountering the falling edge of POT.
3110 +
3111 +
3112 +② The deceleration point signal is valid when starting homing
3113 +
3114 +[[image:file:///C:\Users\Administrator\AppData\Local\Temp\ksohtml22584\wps5.png]]
3115 +
3116 +POT=1 when start homing, run at low speed directly in the reverse direction, and stops at the first Z signal after the falling edge of POT.
3117 +
3118 +
3119 +
3120 +
3121 +
3122 +
3123 +
3124 +
3125 +
3126 +
3127 +
3128 +
3129 +
3130 +(3) P01-40=3
3131 +
3132 +Mechanical homing: Motor Z signal
3133 +
3134 +Deceleration point: Home switch (HW)
3135 +
3136 +① The deceleration point signal is invalid when starting homing
3137 +
3138 +[[image:file:///C:\Users\Administrator\AppData\Local\Temp\ksohtml22584\wps6.png]]
3139 +
3140 +When it starts to homing, HW=0. It starts to homing at a forward high speed. After encountering the rising edge of HW, it decelerates and reverses the direction. It runs at a reverse low speed. After encountering the falling edge of HW, it continues to run, and then stops when encountering the first Z signal.
3141 +
3142 +
3143 +② The deceleration point signal is valid when starting homing
3144 +
3145 +[[image:file:///C:\Users\Administrator\AppData\Local\Temp\ksohtml22584\wps7.png]]
3146 +
3147 +When starting homing, HW=1, start homing at low speed in reverse directly, and stop at the first Z signal after encountering the falling edge of HW;
3148 +
3149 +
3150 +
3151 +
3152 +
3153 +
3154 +
3155 +
3156 +
3157 +
3158 +
3159 +
3160 +
3161 +(4) P01-40=4
3162 +
3163 +Mechanical homing: Motor Z signal
3164 +
3165 +Deceleration point: Home switch (HW)
3166 +
3167 +① The deceleration point signal is invalid when starting homing
3168 +
3169 +[[image:file:///C:\Users\Administrator\AppData\Local\Temp\ksohtml22584\wps8.png]]
3170 +
3171 +HW=0 when starting to homing, directly start to homing at low speed, and stop at the first Z signal after encountering the rising edge of HW;
3172 +
3173 +
3174 +② The deceleration point signal is valid when starting homing
3175 +
3176 +[[image:file:///C:\Users\Administrator\AppData\Local\Temp\ksohtml22584\wps9.jpg]]
3177 +
3178 +
3179 +When starting to homing, HW = 1, start to homing at a high speed in the reverse direction. After encountering the falling edge of HW, decelerate and reverse, run at a low speed in the forward direction, and stop at the first Z signal after encountering the rising edge of HW.
3180 +
3181 +
3182 +
3183 +
3184 +
3185 +(5) P01-40=5
3186 +
3187 +Mechanical homing: Motor Z signal
3188 +
3189 +Deceleration point: Home switch (HW)
3190 +
3191 +① The deceleration point signal is invalid when starting homing
3192 +
3193 +[[image:file:///C:\Users\Administrator\AppData\Local\Temp\ksohtml22584\wps10.png]]
3194 +
3195 +When it starts to homing, HW = 0, and it starts to homing at a reverse high speed. After encountering the rising edge of HW, it decelerates and reverses the direction, runs at a forward low speed, and stops at the first Z signal after encountering the falling edge of HW.
3196 +
3197 +
3198 +② The deceleration point signal is valid when starting homing
3199 +
3200 +[[image:file:///C:\Users\Administrator\AppData\Local\Temp\ksohtml22584\wps11.png]]
3201 +
3202 +When starting homing, HW=1, it will start homing directly at low speed, and the first Z signal after encountering the falling edge of HW will stop;
3203 +
3204 +
3205 +
3206 +
3207 +
3208 +(6) P01-40=6
3209 +
3210 +Mechanical homing: Motor Z signal
3211 +
3212 +Deceleration point: Home switch (HW)
3213 +
3214 +① The deceleration point signal is invalid when starting homing
3215 +
3216 +[[image:file:///C:\Users\Administrator\AppData\Local\Temp\ksohtml22584\wps12.png]]
3217 +
3218 +When starting to homing, HW=0, directly reverse low speed starts to homing, and the first Z signal stops after encountering the rising edge of HW;
3219 +
3220 +
3221 +② The deceleration point signal is valid when starting homing
3222 +
3223 +[[image:file:///C:\Users\Administrator\AppData\Local\Temp\ksohtml22584\wps13.png]]
3224 +
3225 +When starting to homing, HW = 1, start to homing at a forward high speed, after encountering the falling edge of HW, decelerate and reverse, run at a reverse low speed, and stop at the first Z signal after encountering the rising edge of HW.
3226 +
3227 +
3228 +
3229 +
3230 +
3231 +(7) P01-40=7
3232 +
3233 +Mechanical homing: Motor Z signal
3234 +
3235 +Deceleration point: Home switch (HW)
3236 +
3237 +① The deceleration point signal is invalid when starting homing, the forward limit switch is not encountered
3238 +
3239 +[[image:file:///C:\Users\Administrator\AppData\Local\Temp\ksohtml22584\wps14.png]]
3240 +
3241 +When it starts to homing, HW = 0, and it starts to homing at a forward high speed. If the limit switch is not encountered, after encountering the rising edge of HW, it decelerates and reverses the direction, and runs at a reverse low speed. The first Z signal after encountering the falling edge of HW stops.
3242 +
3243 +
3244 +When homing, the deceleration point signal is invalid and the forward limit switch is encountered
3245 +
3246 +[[image:file:///C:\Users\Administrator\AppData\Local\Temp\ksohtml22584\wps15.jpg]]
3247 +
3248 +When it starts to homing, HW = 0, and it starts to homing at a forward high speed. If it encounters a limit switch, it will automatically reverse and run at a reverse high speed. After encountering the rising edge of HW, it will slow down and continue to run at a reverse low speed. The first Z signal after the falling edge of HW will stop.
3249 +
3250 +
3251 +③ The deceleration point signal is valid when starting homing
3252 +
3253 +[[image:file:///C:\Users\Administrator\AppData\Local\Temp\ksohtml22584\wps16.png]]
3254 +
3255 +When starting homing, HW=1, then directly reverse the low speed to start homing, and stop the first Z signal after encountering the falling edge of HW;
3256 +
3257 +
3258 +(8) P01-40=8
3259 +
3260 +Mechanical homing: Motor Z signal
3261 +
3262 +Deceleration point: Home switch (HW)
3263 +
3264 +① The deceleration point signal is invalid when starting homing, the forward limit switch is not encountered
3265 +
3266 +[[image:file:///C:\Users\Administrator\AppData\Local\Temp\ksohtml22584\wps17.png]]
3267 +
3268 +When it starts to homing, HM-0 starts to homing at a forward high speed. If it does not encounter the limit switch, after encountering the rising edge of HW, slow down and reverse, and run at a reverse low speed. After encountering the falling edge of HW, reverse, run at a forward low speed, and stop at the first Z signal after encountering the rising edge of HW.
3269 +
3270 +
3271 +① The deceleration point signal is invalid when starting homing, the forward limit switch is encountered
3272 +
3273 +[[image:file:///C:\Users\Administrator\AppData\Local\Temp\ksohtml22584\wps18.png]]
3274 +
3275 +When it starts to homing, HW = 0, and it starts to homing at forward high speed. If it encounters a limit switch, it will automatically reverse and run at reverse high speed; After encountering the rising edge of HW, slow down and run at a reverse low speed; After encountering the falling edge of HW, reverse the direction, run at a forward low speed, and stop the first Z signal after encountering the rising edge of HW.
3276 +
3277 +
3278 +③ The deceleration point signal is valid when starting homing
3279 +
3280 +[[image:file:///C:\Users\Administrator\AppData\Local\Temp\ksohtml22584\wps19.png]]
3281 +
3282 +When starting to homing, HM-1 will directly reverse and start to return to zero at low speed. After encountering the falling edge of HW, it will reverse and run at forward low speed. The first Z signal after encountering the rising edge of HW will stop.
3283 +
3284 +
3285 +
3286 +(9) P01-40=9
3287 +
3288 +Mechanical homing: Motor Z signal
3289 +
3290 +Deceleration point: Home switch (HW)
3291 +
3292 +① The deceleration point signal is invalid when starting homing, the forward limit switch is not encountered
3293 +
3294 +[[image:file:///C:\Users\Administrator\AppData\Local\Temp\ksohtml22584\wps20.png]]
3295 +
3296 +When it starts to homing, HW=0, and it starts to homing at a forward high speed. If the limit switch is not encountered, after encountering the rising edge of HW, it decelerates and runs at a forward low speed; After encountering the falling edge of HW, reverse, run at a low speed in the reverse direction, and stop at the first Z signal after encountering the rising edge of HW.
3297 +
3298 +
3299 +① The deceleration point signal is invalid when starting homing, the forward limit switch is encountered
3300 +
3301 +[[image:file:///C:\Users\Administrator\AppData\Local\Temp\ksohtml22584\wps21.png]]
3302 +
3303 +When it starts to homing, HW = 0, and it starts to homing at a forward high speed. If it encounters a limit switch, it will automatically reverse and run at a reverse high speed. After encountering a rising edge of HW, it will slow down and reverse to resume forward operation. Running at a forward low speed, after encountering a falling edge of HW, it will reverse. During reverse low speed operation, the first Z signal after encountering a rising edge of HW will stop.
3304 +
3305 +③ The deceleration point signal is valid when starting homing
3306 +
3307 +[[image:file:///C:\Users\Administrator\AppData\Local\Temp\ksohtml22584\wps22.png]]
3308 +
3309 +When starting homing, HW=1 starts homing directly at forward low speed. After encountering the falling edge of HW, the first Z signal after encountering the rising edge of HW stops in reverse and reverse low speed operation;
3310 +
3311 +
3312 +(10) P01-40=10
3313 +
3314 +Mechanical homing: Motor Z signal
3315 +
3316 +Deceleration point: Home switch (HW)
3317 +
3318 +① The deceleration point signal is invalid when starting homing, the forward limit switch is not encountered
3319 +
3320 +[[image:file:///C:\Users\Administrator\AppData\Local\Temp\ksohtml22584\wps23.png]]
3321 +
3322 +When it starts to homing, HW = 0, and it starts to homing at a forward high speed. If the limit switch is not encountered, after encountering the rising edge of HW, slow down and run at a forward low speed. After encountering the falling edge of HW, continue to run at a forward low speed, and then the first Z signal encountered stops.
3323 +
3324 +When homing, the deceleration point signal is invalid and the forward limit switch is encountered
3325 +
3326 +[[image:file:///C:\Users\Administrator\AppData\Local\Temp\ksohtml22584\wps24.jpg]]
3327 +
3328 +When it starts to homing, HW = 0, and it starts to homing at a forward high speed. If it encounters a limit switch, it will automatically reverse and run at a reverse high speed. After encountering the rising edge of HW, it will slow down and reverse to resume forward operation. The first Z signal after the low speed encounters the falling edge of HW will stop.
3329 +
3330 +
3331 +③ The deceleration point signal is valid when starting homing
3332 +
3333 +[[image:file:///C:\Users\Administrator\AppData\Local\Temp\ksohtml22584\wps25.png]]
3334 +
3335 +When starting homing, HW=1, it will start homing directly at low speed, and the first Z signal after encountering the falling edge of HW will stop;
3336 +
3337 +
3338 +(11) P01-40=11
3339 +
3340 +Mechanical homing: Motor Z signal
3341 +
3342 +Deceleration point: Home switch (HW)
3343 +
3344 +① The deceleration point signal is invalid when starting homing, the reverse limit switch is not encountered
3345 +
3346 +[[image:file:///C:\Users\Administrator\AppData\Local\Temp\ksohtml22584\wps26.png]]
3347 +
3348 +When it starts to homing, HW=0, and it starts to homing at a reverse high speed. If the limit switch is not encountered, after encountering the rising edge of HW, it decelerates and reverses the direction, runs at a forward low speed, and stops at the first Z signal after encountering the falling edge of HW.
3349 +
3350 +
3351 +① The deceleration point signal is invalid when starting homing, the reverse limit switch is encountered
3352 +
3353 +[[image:file:///C:\Users\Administrator\AppData\Local\Temp\ksohtml22584\wps27.png]]
3354 +
3355 +When it starts to homing, HW=0, and it starts to homing at a reverse high speed. If it encounters a limit switch, it will automatically reverse and run at a forward high speed. After encountering a rising edge of HW, slow down and continue to run at a forward low speed. When encountering a falling edge of HW, the first Z signal after the edge stops.
3356 +
3357 +③ The deceleration point signal is valid when starting homing
3358 +
3359 +[[image:file:///C:\Users\Administrator\AppData\Local\Temp\ksohtml22584\wps28.png]]
3360 +
3361 +When starting homing, HW=1, it will start homing directly at low speed, and the first Z signal after encountering the falling edge of HW will stop;
3362 +
3363 +
3364 +(12) P01-40=12
3365 +
3366 +Mechanical homing: Motor Z signal
3367 +
3368 +Deceleration point: Home switch (HW)
3369 +
3370 +① The deceleration point signal is invalid when starting homing, the reverse limit switch is not encountered
3371 +
3372 +[[image:file:///C:\Users\Administrator\AppData\Local\Temp\ksohtml22584\wps29.png]]
3373 +
3374 +When it starts to homing, HW = 0, it starts to homing at a reverse high speed, and does not encounter a limit switch. After encountering the rising edge of HW, it decelerates and reverses, and runs at a forward low speed. After encountering the falling edge of HW, it reverses and runs at a reverse low speed, and stops at the first Z signal after encountering the rising edge of HW.
3375 +
3376 +
3377 +
3378 +① The deceleration point signal is invalid when starting homing, the reverse limit switch is encountered
3379 +
3380 +[[image:file:///C:\Users\Administrator\AppData\Local\Temp\ksohtml22584\wps30.png]]
3381 +
3382 +When it starts to homing, HW=0, it starts to homing at a reverse high speed, encounters a limit switch, automatically reverses, runs at a forward high speed, encounters a rising edge of HW, decelerates, runs at a forward low speed, encounters a falling edge of HW, reverses, runs at a reverse low speed, and stops at the first Z signal after encountering a rising edge of HW.
3383 +
3384 +
3385 +③ The deceleration point signal is valid when starting homing
3386 +
3387 +[[image:file:///C:\Users\Administrator\AppData\Local\Temp\ksohtml22584\wps31.png]]
3388 +
3389 +When starting to homing, HW = 1, it will directly start to homing at a forward low speed. After encountering the falling edge of HW, it will reverse and run at a reverse low speed. The first Z signal after encountering the rising edge of HW will stop.
3390 +
3391 +(13) P01-40=13
3392 +
3393 +Mechanical homing: Motor Z signal
3394 +
3395 +Deceleration point: Home switch (HW)
3396 +
3397 +① The deceleration point signal is invalid when starting homing, the reverse limit switch is not encountered
3398 +
3399 +[[image:file:///C:\Users\Administrator\AppData\Local\Temp\ksohtml22584\wps32.png]]
3400 +
3401 +When it starts to homing, HW=0, and it starts to homing at a reverse high speed. If it does not encounter the limit switch, after encountering the rising edge of HW, slow down and run at a reverse low speed. After encountering the falling edge of HW, reverse and run at a forward low speed, and stop at the first Z signal after encountering the rising edge of HW.
3402 +
3403 +
3404 +① The deceleration point signal is invalid when starting homing, the reverse limit switch is encountered
3405 +
3406 +[[image:file:///C:\Users\Administrator\AppData\Local\Temp\ksohtml22584\wps33.png]]
3407 +
3408 +When it starts to homing, HW=0, it starts to homing at reverse high speed, encounters the limit switch, automatically reverses, runs at forward high speed, after encountering the rising edge of HW, decelerates and runs in reverse low speed, and encounters the falling edge of HW when running at reverse low speed, the first Z signal after encountering the rising edge of HW stops.
3409 +
3410 +③ The deceleration point signal is valid when starting homing
3411 +
3412 +[[image:file:///C:\Users\Administrator\AppData\Local\Temp\ksohtml22584\wps34.png]]
3413 +
3414 +When starting homing, HW=1 starts homing directly at reverse low speed. After encountering the falling edge of HW, the first Z signal after encountering the rising edge of HW stops in reverse and forward low speed operation;
3415 +
3416 +
3417 +(14) P01-40=14
3418 +
3419 +Mechanical homing: Motor Z signal
3420 +
3421 +Deceleration point: Home switch (HW)
3422 +
3423 +① The deceleration point signal is invalid when starting homing, the reverse limit switch is not encountered
3424 +
3425 +[[image:file:///C:\Users\Administrator\AppData\Local\Temp\ksohtml22584\wps35.png]]
3426 +
3427 +When it starts to homing, HW=0, it starts to homing at reverse high speed, and does not encounter the limit switch. After encountering the rising edge of HW, it decelerates and runs at reverse low speed. After encountering the falling edge of HW, it continues to run at reverse low speed, and then the first Z signal encountered stops.
3428 +
3429 +
3430 +① The deceleration point signal is invalid when starting homing, the reverse limit switch is encountered
3431 +
3432 +[[image:file:///C:\Users\Administrator\AppData\Local\Temp\ksohtml22584\wps36.png]]
3433 +
3434 +When it starts to homing, HW = 0, it starts to homing at a reverse high speed, encounters a limit switch, automatically reverses, runs at a forward high speed, encounters a rising edge of HW, decelerates and runs in a reverse direction, and stops the first Z signal after encountering a falling edge of HW at a reverse low speed.
3435 +
3436 +
3437 +③ The deceleration point signal is valid when starting homing
3438 +
3439 +[[image:file:///C:\Users\Administrator\AppData\Local\Temp\ksohtml22584\wps37.png]]
3440 +
3441 +When starting homing, HW=1, then directly reverse the low speed to start homing, and stop the first Z signal after encountering the falling edge of HW;
3442 +
3443 +
3444 +(15) P01-40=17
3445 +
3446 +Mechanical homing: Negative overrun switch (NOT)
3447 +
3448 +Deceleration point: Negative overrun switch (NOT)
3449 +
3450 +① The deceleration point signal is invalid when starting homing
3451 +
3452 +[[image:file:///C:\Users\Administrator\AppData\Local\Temp\ksohtml22584\wps38.png]]
3453 +
3454 +When it starts to homing, NOT = 0, it starts to homing at a high speed in the reverse direction. After encountering the rising edge of NOT, it decelerates and reverses the direction, runs at a low speed in the forward direction, and stops after encountering the falling edge of NOT.
3455 +
3456 +
3457 +② The deceleration point signal is valid when starting homing
3458 +
3459 +[[image:file:///C:\Users\Administrator\AppData\Local\Temp\ksohtml22584\wps39.png]]
3460 +
3461 +When starting homing, NOT=1, start homing directly at low speed, and stop after encountering the falling edge of NOT.
3462 +
3463 +
3464 +(16) P01-40=18
3465 +
3466 +Mechanical homing: Positive overrun switch (POT)
3467 +
3468 +Deceleration point: Positive overrun switch (POT)
3469 +
3470 +① The deceleration point signal is invalid when starting homing
3471 +
3472 +[[image:file:///C:\Users\Administrator\AppData\Local\Temp\ksohtml22584\wps40.png]]
3473 +
3474 +When it starts to return to zero, POT=0, it starts to homing at a forward high speed, after encountering the rising edge of POT, it decelerates and reverses, runs at a reverse low speed, and stops after encountering the falling edge of POT.
3475 +
3476 +
3477 +② The deceleration point signal is valid when starting homing
3478 +
3479 +[[image:file:///C:\Users\Administrator\AppData\Local\Temp\ksohtml22584\wps41.png]]
3480 +
3481 +When starting homing, POT=1, start homing at low speed in reverse directly, and stop when encountering POT falling edge;
3482 +
3483 +
3484 +
3485 +(17) P01-40=19
3486 +
3487 +Mechanical homing: Home switch (HW)
3488 +
3489 +Deceleration point: Home switch (HW)
3490 +
3491 +① The deceleration point signal is invalid when starting homing
3492 +
3493 +[[image:file:///C:\Users\Administrator\AppData\Local\Temp\ksohtml22584\wps42.png]]
3494 +
3495 +When it starts to homing, HW=0, and it starts to homing at a forward high speed. After encountering the rising edge of HW, it decelerates and reverses the direction, runs at a reverse low speed, and stops when encountering the falling edge of HW.
3496 +
3497 +
3498 +② The deceleration point signal is valid when starting homing
3499 +
3500 +[[image:file:///C:\Users\Administrator\AppData\Local\Temp\ksohtml22584\wps43.png]]
3501 +
3502 +When starting homing, HW=1, start homing at low speed in reverse directly, and stop when encountering HW falling edge;
3503 +
3504 +
3505 +(18) P01-40=20
3506 +
3507 +Mechanical homing: Home switch (HW)
3508 +
3509 +Deceleration point: Home switch (HW)
3510 +
3511 +① The deceleration point signal is invalid when starting homing
3512 +
3513 +[[image:file:///C:\Users\Administrator\AppData\Local\Temp\ksohtml22584\wps44.png]]
3514 +
3515 +When starting to homing, HW=0, directly start to homing at low speed, and stop after encountering the rising edge of HW;
3516 +
3517 +
3518 +② The deceleration point signal is valid when starting homing
3519 +
3520 +[[image:file:///C:\Users\Administrator\AppData\Local\Temp\ksohtml22584\wps45.png]]
3521 +
3522 +When starting to homing, HW = 1, start to homing at a high speed in the reverse direction. After encountering the falling edge of HW, slow down and reverse the direction, run at a low speed in the forward direction, and stop when encountering the rising edge of HW.
3523 +
3524 +
3525 +(19) P01-40=21
3526 +
3527 +Mechanical homing: Home switch (HW)
3528 +
3529 +Deceleration point: Home switch (HW)
3530 +
3531 +① The deceleration point signal is invalid when starting homing
3532 +
3533 +[[image:file:///C:\Users\Administrator\AppData\Local\Temp\ksohtml22584\wps46.png]]
3534 +
3535 +When it starts to homing, HW=0, it starts to homing at a reverse high speed. After encountering the rising edge of HW, it decelerates and reverses the direction, runs at a forward low speed, and stops when encountering the falling edge of HW.
3536 +
3537 +
3538 +② The deceleration point signal is valid when starting homing
3539 +
3540 +[[image:file:///C:\Users\Administrator\AppData\Local\Temp\ksohtml22584\wps47.png]]
3541 +
3542 +When starting back to zero, HW=1, it will start homing directly at low speed, and stop after encountering the falling edge of HW;
3543 +
3544 +
3545 +(20) P01-40=22
3546 +
3547 +Mechanical homing: Home switch (HW)
3548 +
3549 +Deceleration point: Home switch (HW)
3550 +
3551 +① The deceleration point signal is invalid when starting homing
3552 +
3553 +[[image:file:///C:\Users\Administrator\AppData\Local\Temp\ksohtml22584\wps48.png]]
3554 +
3555 +When starting to homing, HW=0, directly reverse low speed starts to homing, and stops when encountering HW rising edge;
3556 +
3557 +
3558 +Deceleration point signal is valid when homing start
3559 +
3560 +[[image:file:///C:\Users\Administrator\AppData\Local\Temp\ksohtml22584\wps49.jpg]]
3561 +
3562 +When starting to homing, HW=1, start to homing at a forward high speed, after encountering the falling edge of HW, slow down and reverse, run at a reverse low speed, and stop when encountering the rising edge of HW.
3563 +
3564 +
3565 +(21) P01-40=23
3566 +
3567 +Mechanical homing: Home switch (HW)
3568 +
3569 +Deceleration point: Home switch (HW)
3570 +
3571 +① The deceleration point signal is invalid when starting homing, the forward limit switch is not encountered
3572 +
3573 +[[image:file:///C:\Users\Administrator\AppData\Local\Temp\ksohtml22584\wps50.png]]
3574 +
3575 +When it starts to homing, HW = 0, it starts to homing at a forward high speed, and does not encounter a limit switch. After encountering the rising edge of HW, it decelerates and reverses, runs at a reverse low speed, and stops when encountering the falling edge of HW.
3576 +
3577 +
3578 +① The deceleration point signal is invalid when starting homing, the forward limit switch is encountered
3579 +
3580 +[[image:file:///C:\Users\Administrator\AppData\Local\Temp\ksohtml22584\wps51.png]]
3581 +
3582 +When you start homing, HW = 0, start homing at a forward high speed. When encountering the limit switch, it will automatically reverse and run at a reverse high speed. After encountering the rising edge of HW, slow down, continue to run at reverse low speed, and stop when encountering the HW falling edge.
3583 +
3584 +
3585 +
3586 +③ The deceleration point signal is valid when starting homing
3587 +
3588 +[[image:file:///C:\Users\Administrator\AppData\Local\Temp\ksohtml22584\wps52.png]]
3589 +
3590 +When it starts to homing, HW=1, it starts to homing at a reverse low speed, and stops when it encounters the falling edge of HW.
3591 +
3592 +
3593 +(22) P01-40=24
3594 +
3595 +Mechanical homing: Home switch (HW)
3596 +
3597 +Deceleration point: Home switch (HW)
3598 +
3599 +① The deceleration point signal is invalid when starting homing, the forward limit switch is not encountered
3600 +
3601 +[[image:file:///C:\Users\Administrator\AppData\Local\Temp\ksohtml22584\wps53.png]]
3602 +
3603 +When it starts to homing, HW = 0, it starts to homing at a forward high speed, and does not encounter a limit switch. After encountering the rising edge of HW, it decelerates and reverses, and runs at a reverse low speed. After encountering the falling edge of HW, it reverses and runs at a forward low speed, and stops when encountering the rising edge of HW.
3604 +
3605 +
3606 +① The deceleration point signal is invalid when starting homing, the forward limit switch is encountered
3607 +
3608 +[[image:file:///C:\Users\Administrator\AppData\Local\Temp\ksohtml22584\wps54.png]]
3609 +
3610 +When it starts to homing, HW = 0, it starts to homing at forward high speed, encounters the limit switch, automatically reverses, runs at reverse high speed, encounters the rising edge of HW, decelerates and runs at reverse low speed, encounters the falling edge of HW, reverses, runs at forward low speed, and stops when encountering the rising edge of HW.
3611 +
3612 +
3613 +③ The deceleration point signal is valid when starting homing
3614 +
3615 +[[image:file:///C:\Users\Administrator\AppData\Local\Temp\ksohtml22584\wps55.png]]
3616 +
3617 +When starting with homing, HW = 1, it will directly reverse the low speed and start to homing. After encountering the falling edge of HW, it will reverse the direction and run at a forward low speed, and stop when encountering the rising edge of HW.
3618 +
3619 +
3620 +(23) P01-40=25
3621 +
3622 +Mechanical homing: Home switch (HW)
3623 +
3624 +Deceleration point: Home switch (HW)
3625 +
3626 +① The deceleration point signal is invalid when starting homing, the forward limit switch is not encountered
3627 +
3628 +[[image:file:///C:\Users\Administrator\AppData\Local\Temp\ksohtml22584\wps56.png]]
3629 +
3630 +When it starts to homing, HW=0, it starts to homing at a forward high speed, and does not encounter a limit switch. After encountering the rising edge of HW, it decelerates and runs at a forward low speed. After encountering the falling edge of HW, it reverses and runs at a reverse low speed, and stops when encountering the rising edge of HW.
3631 +
3632 +
3633 +① The deceleration point signal is invalid when starting homing, the forward limit switch is encountered
3634 +
3635 +[[image:file:///C:\Users\Administrator\AppData\Local\Temp\ksohtml22584\wps57.png]]
3636 +
3637 +When it starts to homing, HW=0, it starts to homing at forward high speed, encounters the limit switch, automatically reverses, and runs at reverse high speed. After encountering the rising edge of HW, decelerate and reverse to resume forward operation. After encountering the falling edge of HW at forward low speed, reverse. When running at reverse low speed, stop when encountering the rising edge of HW.
3638 +
3639 +
3640 +③ The deceleration point signal is valid when starting homing
3641 +
3642 +[[image:file:///C:\Users\Administrator\AppData\Local\Temp\ksohtml22584\wps58.png]]
3643 +
3644 +When starting homing, when HW=1, it starts to homing directly at low speed in the forward direction. After encountering the falling edge of HW, it stops at the rising edge of HW in the reverse low speed operation
3645 +
3646 +
3647 +(24) P01-40=26
3648 +
3649 +Mechanical homing: Home switch (HW)
3650 +
3651 +Deceleration point: Home switch (HW)
3652 +
3653 +① The deceleration point signal is invalid when starting homing, the forward limit switch is not encountered
3654 +
3655 +[[image:file:///C:\Users\Administrator\AppData\Local\Temp\ksohtml22584\wps59.png]]
3656 +
3657 +When it starts to homing, HW=0, it starts to homing at a forward high speed, and does not encounter a limit switch. After encountering the rising edge of HW, it decelerates, runs at a forward low speed, and stops when encountering the falling edge of HW.
3658 +
3659 +
3660 +① The deceleration point signal is invalid when starting homing, the forward limit switch is encountered
3661 +
3662 +[[image:file:///C:\Users\Administrator\AppData\Local\Temp\ksohtml22584\wps60.png]]
3663 +
3664 +When it starts to homing, HW=0, it starts to homing at forward high speed, encounters the limit switch, automatically reverses, and runs at reverse high speed. After encountering the rising edge of HW, decelerates and reverses to resume forward operation, and stops when encountering the falling edge of HW at forward low speed.
3665 +
3666 +
3667 +③ The deceleration point signal is valid when starting homing
3668 +
3669 +[[image:file:///C:\Users\Administrator\AppData\Local\Temp\ksohtml22584\wps61.png]]
3670 +
3671 +When starting homing, HW=1, it will start homing directly at low speed, and stop when encountering HW falling edge;
3672 +
3673 +
3674 +(25) P01-40=27
3675 +
3676 +Mechanical homing: Home switch (HW)
3677 +
3678 +Deceleration point: Home switch (HW)
3679 +
3680 +① The deceleration point signal is invalid when starting homing, the reverse limit switch is not encountered
3681 +
3682 +[[image:file:///C:\Users\Administrator\AppData\Local\Temp\ksohtml22584\wps62.png]]
3683 +
3684 +When it starts to homing, HW=0, it starts to homing at a reverse high speed, and does not encounter a limit switch. After encountering the rising edge of HW, it decelerates and reverses the direction, runs at a forward low speed, and stops when encountering the falling edge of HW.
3685 +
3686 +
3687 +① The deceleration point signal is invalid when starting homing, the reverse limit switch is encountered
3688 +
3689 +[[image:file:///C:\Users\Administrator\AppData\Local\Temp\ksohtml22584\wps63.png]]
3690 +
3691 +When it starts to homing, HW=0, it starts to homing at a reverse high speed. When it encounters a limit switch, it automatically reverses and runs at a forward high speed. When it encounters a rising edge of HW, it decelerates and continues to run at a forward low speed. When it encounters a falling edge of HW, it stops.
3692 +
3693 +
3694 +③ The deceleration point signal is valid when starting homing
3695 +
3696 +[[image:file:///C:\Users\Administrator\AppData\Local\Temp\ksohtml22584\wps64.png]]
3697 +
3698 +When starting homing, HW=1, it will start homing directly at low speed, and stop when encountering HW falling edge;
3699 +
3700 +
3701 +(26) P01-40=28
3702 +
3703 +Mechanical homing: Home switch (HW)
3704 +
3705 +Deceleration point: Home switch (HW)
3706 +
3707 +① The deceleration point signal is invalid when starting homing, the reverse limit switch is not encountered
3708 +
3709 +[[image:file:///C:\Users\Administrator\AppData\Local\Temp\ksohtml22584\wps65.png]]
3710 +
3711 +When it starts to homing, HW=0, it starts to homing at a reverse high speed, and does not encounter a limit switch. After encountering the rising edge of HW, it decelerates and reverses, and runs at a forward low speed. After encountering the falling edge of HW, it reverses and runs at a reverse low speed, and stops when encountering the rising edge of HW.
3712 +
3713 +
3714 +① The deceleration point signal is invalid when starting homing, the reverse limit switch is encountered
3715 +
3716 +[[image:file:///C:\Users\Administrator\AppData\Local\Temp\ksohtml22584\wps66.png]]
3717 +
3718 +When it starts to homing, HW=0, it starts to homing at a reverse high speed. When encountering a limit switch, it automatically reverses and runs at a forward high speed. When encountering a rising edge of HW, it decelerates and runs at a forward low speed. When encountering a falling edge of HW, it reverses and runs at a reverse low speed. When encountering a rising edge of HW, it stops.
3719 +
3720 +
3721 +③ The deceleration point signal is valid when starting homing
3722 +
3723 +[[image:file:///C:\Users\Administrator\AppData\Local\Temp\ksohtml22584\wps67.png]]
3724 +
3725 +When starting with homing, HW = 1, it will directly start to homing at a forward low speed. After encountering the falling edge of HW, it will reverse and run at a reverse low speed. When encountering the rising edge of HW, it will stop.
3726 +
3727 +
3728 +(27) P01-40=29
3729 +
3730 +Mechanical homing: Home switch (HW)
3731 +
3732 +Deceleration point: Home switch (HW)
3733 +
3734 +① The deceleration point signal is invalid when starting homing, the reverse limit switch is not encountered
3735 +
3736 +[[image:file:///C:\Users\Administrator\AppData\Local\Temp\ksohtml22584\wps68.png]]
3737 +
3738 +When it starts to homing, HW = 0, it starts to homing at a reverse high speed, and does not encounter a limit switch. After encountering the rising edge of HW, it decelerates and runs at a reverse low speed. After encountering the falling edge of HW, it reverses and runs at a forward low speed, and stops when encountering the rising edge of HW.
3739 +
3740 +
3741 +① The deceleration point signal is invalid when starting homing, the reverse limit switch is encountered
3742 +
3743 +[[image:file:///C:\Users\Administrator\AppData\Local\Temp\ksohtml22584\wps69.png]]
3744 +
3745 +When it starts to homing, HW=0, it starts to homing at a reverse high speed. When it encounters a limit switch, it automatically reverses and runs at a forward high speed. After encountering a rising edge of HW, it decelerates and runs in a reverse low speed. After encountering a falling edge of HW, it reverses. When running at a forward low speed, it stops when it encounters a rising edge of HW.
3746 +
3747 +③ The deceleration point signal is valid when starting homing
3748 +
3749 +[[image:file:///C:\Users\Administrator\AppData\Local\Temp\ksohtml22584\wps70.png]]
3750 +
3751 +When starting homing, when HW=1, it starts to homing directly at low speed in reverse direction. After encountering the falling edge of HW, it stops when running at low speed in reverse direction and forward direction and encountering the rising edge of HW
3752 +
3753 +
3754 +(28) P01-40=30
3755 +
3756 +Mechanical homing: Home switch (HW)
3757 +
3758 +Deceleration point: Home switch (HW)
3759 +
3760 +① The deceleration point signal is invalid when starting homing, the reverse limit switch is not encountered
3761 +
3762 +[[image:file:///C:\Users\Administrator\AppData\Local\Temp\ksohtml22584\wps71.png]]
3763 +
3764 +When it starts to homing, HW=0, it starts to homing at reverse high speed, and does not encounter the limit switch. After encountering the rising edge of HW, it decelerates, runs at reverse low speed, and stops when encountering the falling edge of HW.
3765 +
3766 +
3767 +① The deceleration point signal is invalid when starting homing, the reverse limit switch is encountered
3768 +
3769 +[[image:file:///C:\Users\Administrator\AppData\Local\Temp\ksohtml22584\wps72.png]]
3770 +
3771 +When it starts to homing, HW=0, it starts to homing at a reverse high speed. When it encounters a limit switch, it automatically reverses and runs at a forward high speed. When it encounters a rising edge of HW, it decelerates and runs in a reverse low speed. When it encounters a falling edge of HW, it stops.
3772 +
3773 +
3774 +③ The deceleration point signal is valid when starting homing
3775 +
3776 +[[image:file:///C:\Users\Administrator\AppData\Local\Temp\ksohtml22584\wps73.png]]
3777 +
3778 +When starting homing, HW=1, start homing at low speed in reverse directly, and stop when encountering HW falling edge;
3779 +
3780 +
3781 +(29) P01-40=33 and P01-40=34
3782 +
3783 +Mechanical homing: Z signal.
3784 +
3785 +Deceleration point: None
3786 +
3787 +Homing mode 33: Reverse low speed operation, stop the first Z signal encountered
3788 +
3789 +Homing mode 34: running at low speed in forward direction, stopping the first Z signal encountered
3790 +
3791 +[[image:file:///C:\Users\Administrator\AppData\Local\Temp\ksohtml22584\wps74.png]]
3792 +
3793 +
3794 +(30) P01-40=35
3795 +
3796 +Homing mode 35, taking the current position as the mechanical homing, after triggering the homing (P01-39: 0x00→0x01/0x00 → 0x02);
3797 +
3798 +After the homing is completed, according to the set value of P10-08 (homing bias compensation), P10-06 (encoder multi-turn reset operation) is executed.
3799 +
3800 +
3801 +