Changes for page 06 Operation
Last modified by Iris on 2025/07/23 15:49
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -2878,3 +2878,916 @@ 2878 2878 ((( 2879 2879 ✎**Note:** It is advised to configure function codes for DO terminals in sequence to avoid errors. Please use the shielded overload protection fault detection function with caution, otherwise it will cause burn out the motor. 2880 2880 ))) 2881 + 2882 + 2883 +== Homing mode == 2884 + 2885 +The homing mode is used to find the mechanical origin and locate the positional relationship between the mechanical origin and the mechanical zero. 2886 + 2887 +Mechanical homing: A mechanically fixed position may correspond to a certain defined homing switch, or may correspond to the motor Z signal. 2888 + 2889 +Mechanical zero point: Mechanically absolute 0 position. 2890 + 2891 +After the homing, the stop position of the motor is the mechanical homing. By setting P10-08, the relationship between the mechanical homing and the mechanical zero can be set: 2892 + 2893 +Mechanical homing = Mechanical zero +P10-08 (homing offset) 2894 + 2895 +When P10-08=0, the mechanical homing coincides with the mechanical zero. 2896 + 2897 + 2898 +=== Control block diagram === 2899 + 2900 +[[image:file:///C:\Users\Administrator\AppData\Local\Temp\ksohtml22584\wps1.png]]Figure 6-53 Homing mode control block diagram 2901 + 2902 + 2903 + 2904 +=== Homing mode related function codes === 2905 + 2906 +|Function code|Name|((( 2907 +Setting 2908 + 2909 +method 2910 +)))|((( 2911 +Effective 2912 + 2913 +time 2914 +)))|Default|Range|Definition|Unit 2915 +|P01-39.|Homing start mode|((( 2916 +Stop 2917 + 2918 +settings 2919 +)))|((( 2920 +Immediately 2921 + 2922 +effective 2923 +)))|0|0 to 2|((( 2924 +0: Close 2925 + 2926 +1: The servo is powered ON and started after the first ON 2927 + 2928 +2: DI enable 2929 +)))|- 2930 + 2931 + 2932 +|Function code|Name|((( 2933 +Setting 2934 + 2935 +method 2936 +)))|((( 2937 +Effective 2938 + 2939 +time 2940 +)))|Default|Range|Definition|Unit 2941 +|P01-40|Homing mode|((( 2942 +Stop 2943 + 2944 +settings 2945 +)))|((( 2946 +Immediately 2947 + 2948 +effective 2949 +)))|0|0 to 35|((( 2950 +0 ~~ 35 Homing mode; 2951 + 2952 +✎Note: VD2 currently does not support 15, 16, 31, 32 modes 2953 +)))|- 2954 + 2955 +|Function code|Name|((( 2956 +Setting 2957 + 2958 +method 2959 +)))|((( 2960 +Effective 2961 + 2962 +time 2963 +)))|Default|Range|Definition|Unit 2964 +|P01-41|High-speed search deceleration point signal velocity|((( 2965 +Running 2966 + 2967 +settings 2968 +)))|((( 2969 +Immediately 2970 + 2971 +effective 2972 +)))|300|1 to 3000|High-speed search deceleration point signal velocity in homing mode|rpm 2973 + 2974 +|Function code|Name|((( 2975 +Setting 2976 + 2977 +method 2978 +)))|((( 2979 +Effective 2980 + 2981 +time 2982 +)))|Default|Range|Definition|Unit 2983 +|P01-42〇|Low speed search homing signal speed|((( 2984 +Running 2985 + 2986 +settings 2987 +)))|((( 2988 +Immediately 2989 + 2990 +effective 2991 +)))|60|1 to 300|Low-speed search origin signal velocity in homing mode|rpm 2992 + 2993 +|Function code|Name|((( 2994 +Setting 2995 + 2996 +method 2997 +)))|((( 2998 +Effective 2999 + 3000 +time 3001 +)))|Default|Range|Definition|Unit 3002 +|P01-43〇|Homing acceleration and deceleration|((( 3003 +Running 3004 + 3005 +settings 3006 +)))|((( 3007 +Immediately 3008 + 3009 +effective 3010 +)))|50|1to1000|((( 3011 +Acceleration and deceleration in homing mode 3012 + 3013 +Time for speed acceleration from 0 to 1000rpm 3014 +)))|ms 3015 + 3016 +|Function code|Name|((( 3017 +Setting 3018 + 3019 +method 3020 +)))|((( 3021 +Effective 3022 + 3023 +time 3024 +)))|Default|Range|Definition|Unit 3025 +|P01-44〇|Homing timeout limited time|((( 3026 +Running 3027 + 3028 +settings 3029 +)))|((( 3030 +Immediately 3031 + 3032 +effective 3033 +)))|65535|100 to 65535|Homing timeout limited time|ms 3034 + 3035 +|Function code|Name|((( 3036 +Setting 3037 + 3038 +method 3039 +)))|((( 3040 +Effective 3041 + 3042 +time 3043 +)))|Default|Range|Definition|Unit 3044 +|P10-08〇|Multi-turn absolute encoder homing offset compensation|((( 3045 +Running 3046 + 3047 +settings 3048 +)))|((( 3049 +Immediately 3050 + 3051 +effective 3052 +)))|0|((( 3053 +-2147483647~~ 3054 + 3055 +2147483646 3056 +)))|((( 3057 +P10-08 multi-turn absolute encoder homing offset compensation is used in conjunction with U0-56 multi-turn absolute encoder current position. 3058 + 3059 +When P10-6 is set to 1, the value of U0-56 is updated to P10-8. 3060 +)))|- 3061 + 3062 +== Introduction to homing mode == 3063 + 3064 +In the following figure, "H" represents P01-41 (high-speed search deceleration point signal speed), and "L" represents P01-42 (low-speed search homing signal speed). 3065 + 3066 + 3067 +(1) P01-40 =1 3068 + 3069 +Mechanical homing: Motor Z signal 3070 + 3071 +Deceleration point: Reverse limit switch (NOT) 3072 + 3073 +① The deceleration point signal is invalid when starting homing 3074 + 3075 +[[image:file:///C:\Users\Administrator\AppData\Local\Temp\ksohtml22584\wps2.png]] 3076 + 3077 +When it starts to homing, NOT=0, it starts to homing at a high speed in the reverse direction. After encountering the rising edge of NOT, it decelerates and reverses the direction, runs at a low speed in the forward direction, and stops at the first Z signal after encountering the falling edge of NOT. 3078 + 3079 + 3080 +② The deceleration point signal is valid when starting homing 3081 + 3082 +[[image:file:///C:\Users\Administrator\AppData\Local\Temp\ksohtml22584\wps3.png]] 3083 + 3084 +When starting to homing, NOT=1, it starts to homing at a direct forward low speed, and stops at the first Z signal after encountering the falling edge of NOT. 3085 + 3086 + 3087 + 3088 + 3089 + 3090 + 3091 +(2) P01-40=2 3092 + 3093 +Mechanical homing: Motor Z signal 3094 + 3095 +Deceleration point: Positive Limit Switch (POT) 3096 + 3097 +① The deceleration point signal is invalid when starting homing 3098 + 3099 +[[image:file:///C:\Users\Administrator\AppData\Local\Temp\ksohtml22584\wps4.png]] 3100 + 3101 +When it starts to homing, POT = 0, and it starts to homing at a forward high speed. After encountering the rising edge of POT, it decelerates and reverses, runs at a reverse low speed, and stops at the first Z signal after encountering the falling edge of POT. 3102 + 3103 + 3104 +② The deceleration point signal is valid when starting homing 3105 + 3106 +[[image:file:///C:\Users\Administrator\AppData\Local\Temp\ksohtml22584\wps5.png]] 3107 + 3108 +POT=1 when start homing, run at low speed directly in the reverse direction, and stops at the first Z signal after the falling edge of POT. 3109 + 3110 + 3111 + 3112 + 3113 + 3114 + 3115 + 3116 + 3117 + 3118 + 3119 + 3120 + 3121 + 3122 +(3) P01-40=3 3123 + 3124 +Mechanical homing: Motor Z signal 3125 + 3126 +Deceleration point: Home switch (HW) 3127 + 3128 +① The deceleration point signal is invalid when starting homing 3129 + 3130 +[[image:file:///C:\Users\Administrator\AppData\Local\Temp\ksohtml22584\wps6.png]] 3131 + 3132 +When it starts to homing, HW=0. It starts to homing at a forward high speed. After encountering the rising edge of HW, it decelerates and reverses the direction. It runs at a reverse low speed. After encountering the falling edge of HW, it continues to run, and then stops when encountering the first Z signal. 3133 + 3134 + 3135 +② The deceleration point signal is valid when starting homing 3136 + 3137 +[[image:file:///C:\Users\Administrator\AppData\Local\Temp\ksohtml22584\wps7.png]] 3138 + 3139 +When starting homing, HW=1, start homing at low speed in reverse directly, and stop at the first Z signal after encountering the falling edge of HW; 3140 + 3141 + 3142 + 3143 + 3144 + 3145 + 3146 + 3147 + 3148 + 3149 + 3150 + 3151 + 3152 + 3153 +(4) P01-40=4 3154 + 3155 +Mechanical homing: Motor Z signal 3156 + 3157 +Deceleration point: Home switch (HW) 3158 + 3159 +① The deceleration point signal is invalid when starting homing 3160 + 3161 +[[image:file:///C:\Users\Administrator\AppData\Local\Temp\ksohtml22584\wps8.png]] 3162 + 3163 +HW=0 when starting to homing, directly start to homing at low speed, and stop at the first Z signal after encountering the rising edge of HW; 3164 + 3165 + 3166 +② The deceleration point signal is valid when starting homing 3167 + 3168 +[[image:file:///C:\Users\Administrator\AppData\Local\Temp\ksohtml22584\wps9.jpg]] 3169 + 3170 + 3171 +When starting to homing, HW = 1, start to homing at a high speed in the reverse direction. After encountering the falling edge of HW, decelerate and reverse, run at a low speed in the forward direction, and stop at the first Z signal after encountering the rising edge of HW. 3172 + 3173 + 3174 + 3175 + 3176 + 3177 +(5) P01-40=5 3178 + 3179 +Mechanical homing: Motor Z signal 3180 + 3181 +Deceleration point: Home switch (HW) 3182 + 3183 +① The deceleration point signal is invalid when starting homing 3184 + 3185 +[[image:file:///C:\Users\Administrator\AppData\Local\Temp\ksohtml22584\wps10.png]] 3186 + 3187 +When it starts to homing, HW = 0, and it starts to homing at a reverse high speed. After encountering the rising edge of HW, it decelerates and reverses the direction, runs at a forward low speed, and stops at the first Z signal after encountering the falling edge of HW. 3188 + 3189 + 3190 +② The deceleration point signal is valid when starting homing 3191 + 3192 +[[image:file:///C:\Users\Administrator\AppData\Local\Temp\ksohtml22584\wps11.png]] 3193 + 3194 +When starting homing, HW=1, it will start homing directly at low speed, and the first Z signal after encountering the falling edge of HW will stop; 3195 + 3196 + 3197 + 3198 + 3199 + 3200 +(6) P01-40=6 3201 + 3202 +Mechanical homing: Motor Z signal 3203 + 3204 +Deceleration point: Home switch (HW) 3205 + 3206 +① The deceleration point signal is invalid when starting homing 3207 + 3208 +[[image:file:///C:\Users\Administrator\AppData\Local\Temp\ksohtml22584\wps12.png]] 3209 + 3210 +When starting to homing, HW=0, directly reverse low speed starts to homing, and the first Z signal stops after encountering the rising edge of HW; 3211 + 3212 + 3213 +② The deceleration point signal is valid when starting homing 3214 + 3215 +[[image:file:///C:\Users\Administrator\AppData\Local\Temp\ksohtml22584\wps13.png]] 3216 + 3217 +When starting to homing, HW = 1, start to homing at a forward high speed, after encountering the falling edge of HW, decelerate and reverse, run at a reverse low speed, and stop at the first Z signal after encountering the rising edge of HW. 3218 + 3219 + 3220 + 3221 + 3222 + 3223 +(7) P01-40=7 3224 + 3225 +Mechanical homing: Motor Z signal 3226 + 3227 +Deceleration point: Home switch (HW) 3228 + 3229 +① The deceleration point signal is invalid when starting homing, the forward limit switch is not encountered 3230 + 3231 +[[image:file:///C:\Users\Administrator\AppData\Local\Temp\ksohtml22584\wps14.png]] 3232 + 3233 +When it starts to homing, HW = 0, and it starts to homing at a forward high speed. If the limit switch is not encountered, after encountering the rising edge of HW, it decelerates and reverses the direction, and runs at a reverse low speed. The first Z signal after encountering the falling edge of HW stops. 3234 + 3235 + 3236 +When homing, the deceleration point signal is invalid and the forward limit switch is encountered 3237 + 3238 +[[image:file:///C:\Users\Administrator\AppData\Local\Temp\ksohtml22584\wps15.jpg]] 3239 + 3240 +When it starts to homing, HW = 0, and it starts to homing at a forward high speed. If it encounters a limit switch, it will automatically reverse and run at a reverse high speed. After encountering the rising edge of HW, it will slow down and continue to run at a reverse low speed. The first Z signal after the falling edge of HW will stop. 3241 + 3242 + 3243 +③ The deceleration point signal is valid when starting homing 3244 + 3245 +[[image:file:///C:\Users\Administrator\AppData\Local\Temp\ksohtml22584\wps16.png]] 3246 + 3247 +When starting homing, HW=1, then directly reverse the low speed to start homing, and stop the first Z signal after encountering the falling edge of HW; 3248 + 3249 + 3250 +(8) P01-40=8 3251 + 3252 +Mechanical homing: Motor Z signal 3253 + 3254 +Deceleration point: Home switch (HW) 3255 + 3256 +① The deceleration point signal is invalid when starting homing, the forward limit switch is not encountered 3257 + 3258 +[[image:file:///C:\Users\Administrator\AppData\Local\Temp\ksohtml22584\wps17.png]] 3259 + 3260 +When it starts to homing, HM-0 starts to homing at a forward high speed. If it does not encounter the limit switch, after encountering the rising edge of HW, slow down and reverse, and run at a reverse low speed. After encountering the falling edge of HW, reverse, run at a forward low speed, and stop at the first Z signal after encountering the rising edge of HW. 3261 + 3262 + 3263 +① The deceleration point signal is invalid when starting homing, the forward limit switch is encountered 3264 + 3265 +[[image:file:///C:\Users\Administrator\AppData\Local\Temp\ksohtml22584\wps18.png]] 3266 + 3267 +When it starts to homing, HW = 0, and it starts to homing at forward high speed. If it encounters a limit switch, it will automatically reverse and run at reverse high speed; After encountering the rising edge of HW, slow down and run at a reverse low speed; After encountering the falling edge of HW, reverse the direction, run at a forward low speed, and stop the first Z signal after encountering the rising edge of HW. 3268 + 3269 + 3270 +③ The deceleration point signal is valid when starting homing 3271 + 3272 +[[image:file:///C:\Users\Administrator\AppData\Local\Temp\ksohtml22584\wps19.png]] 3273 + 3274 +When starting to homing, HM-1 will directly reverse and start to return to zero at low speed. After encountering the falling edge of HW, it will reverse and run at forward low speed. The first Z signal after encountering the rising edge of HW will stop. 3275 + 3276 + 3277 + 3278 +(9) P01-40=9 3279 + 3280 +Mechanical homing: Motor Z signal 3281 + 3282 +Deceleration point: Home switch (HW) 3283 + 3284 +① The deceleration point signal is invalid when starting homing, the forward limit switch is not encountered 3285 + 3286 +[[image:file:///C:\Users\Administrator\AppData\Local\Temp\ksohtml22584\wps20.png]] 3287 + 3288 +When it starts to homing, HW=0, and it starts to homing at a forward high speed. If the limit switch is not encountered, after encountering the rising edge of HW, it decelerates and runs at a forward low speed; After encountering the falling edge of HW, reverse, run at a low speed in the reverse direction, and stop at the first Z signal after encountering the rising edge of HW. 3289 + 3290 + 3291 +① The deceleration point signal is invalid when starting homing, the forward limit switch is encountered 3292 + 3293 +[[image:file:///C:\Users\Administrator\AppData\Local\Temp\ksohtml22584\wps21.png]] 3294 + 3295 +When it starts to homing, HW = 0, and it starts to homing at a forward high speed. If it encounters a limit switch, it will automatically reverse and run at a reverse high speed. After encountering a rising edge of HW, it will slow down and reverse to resume forward operation. Running at a forward low speed, after encountering a falling edge of HW, it will reverse. During reverse low speed operation, the first Z signal after encountering a rising edge of HW will stop. 3296 + 3297 +③ The deceleration point signal is valid when starting homing 3298 + 3299 +[[image:file:///C:\Users\Administrator\AppData\Local\Temp\ksohtml22584\wps22.png]] 3300 + 3301 +When starting homing, HW=1 starts homing directly at forward low speed. After encountering the falling edge of HW, the first Z signal after encountering the rising edge of HW stops in reverse and reverse low speed operation; 3302 + 3303 + 3304 +(10) P01-40=10 3305 + 3306 +Mechanical homing: Motor Z signal 3307 + 3308 +Deceleration point: Home switch (HW) 3309 + 3310 +① The deceleration point signal is invalid when starting homing, the forward limit switch is not encountered 3311 + 3312 +[[image:file:///C:\Users\Administrator\AppData\Local\Temp\ksohtml22584\wps23.png]] 3313 + 3314 +When it starts to homing, HW = 0, and it starts to homing at a forward high speed. If the limit switch is not encountered, after encountering the rising edge of HW, slow down and run at a forward low speed. After encountering the falling edge of HW, continue to run at a forward low speed, and then the first Z signal encountered stops. 3315 + 3316 +When homing, the deceleration point signal is invalid and the forward limit switch is encountered 3317 + 3318 +[[image:file:///C:\Users\Administrator\AppData\Local\Temp\ksohtml22584\wps24.jpg]] 3319 + 3320 +When it starts to homing, HW = 0, and it starts to homing at a forward high speed. If it encounters a limit switch, it will automatically reverse and run at a reverse high speed. After encountering the rising edge of HW, it will slow down and reverse to resume forward operation. The first Z signal after the low speed encounters the falling edge of HW will stop. 3321 + 3322 + 3323 +③ The deceleration point signal is valid when starting homing 3324 + 3325 +[[image:file:///C:\Users\Administrator\AppData\Local\Temp\ksohtml22584\wps25.png]] 3326 + 3327 +When starting homing, HW=1, it will start homing directly at low speed, and the first Z signal after encountering the falling edge of HW will stop; 3328 + 3329 + 3330 +(11) P01-40=11 3331 + 3332 +Mechanical homing: Motor Z signal 3333 + 3334 +Deceleration point: Home switch (HW) 3335 + 3336 +① The deceleration point signal is invalid when starting homing, the reverse limit switch is not encountered 3337 + 3338 +[[image:file:///C:\Users\Administrator\AppData\Local\Temp\ksohtml22584\wps26.png]] 3339 + 3340 +When it starts to homing, HW=0, and it starts to homing at a reverse high speed. If the limit switch is not encountered, after encountering the rising edge of HW, it decelerates and reverses the direction, runs at a forward low speed, and stops at the first Z signal after encountering the falling edge of HW. 3341 + 3342 + 3343 +① The deceleration point signal is invalid when starting homing, the reverse limit switch is encountered 3344 + 3345 +[[image:file:///C:\Users\Administrator\AppData\Local\Temp\ksohtml22584\wps27.png]] 3346 + 3347 +When it starts to homing, HW=0, and it starts to homing at a reverse high speed. If it encounters a limit switch, it will automatically reverse and run at a forward high speed. After encountering a rising edge of HW, slow down and continue to run at a forward low speed. When encountering a falling edge of HW, the first Z signal after the edge stops. 3348 + 3349 +③ The deceleration point signal is valid when starting homing 3350 + 3351 +[[image:file:///C:\Users\Administrator\AppData\Local\Temp\ksohtml22584\wps28.png]] 3352 + 3353 +When starting homing, HW=1, it will start homing directly at low speed, and the first Z signal after encountering the falling edge of HW will stop; 3354 + 3355 + 3356 +(12) P01-40=12 3357 + 3358 +Mechanical homing: Motor Z signal 3359 + 3360 +Deceleration point: Home switch (HW) 3361 + 3362 +① The deceleration point signal is invalid when starting homing, the reverse limit switch is not encountered 3363 + 3364 +[[image:file:///C:\Users\Administrator\AppData\Local\Temp\ksohtml22584\wps29.png]] 3365 + 3366 +When it starts to homing, HW = 0, it starts to homing at a reverse high speed, and does not encounter a limit switch. After encountering the rising edge of HW, it decelerates and reverses, and runs at a forward low speed. After encountering the falling edge of HW, it reverses and runs at a reverse low speed, and stops at the first Z signal after encountering the rising edge of HW. 3367 + 3368 + 3369 + 3370 +① The deceleration point signal is invalid when starting homing, the reverse limit switch is encountered 3371 + 3372 +[[image:file:///C:\Users\Administrator\AppData\Local\Temp\ksohtml22584\wps30.png]] 3373 + 3374 +When it starts to homing, HW=0, it starts to homing at a reverse high speed, encounters a limit switch, automatically reverses, runs at a forward high speed, encounters a rising edge of HW, decelerates, runs at a forward low speed, encounters a falling edge of HW, reverses, runs at a reverse low speed, and stops at the first Z signal after encountering a rising edge of HW. 3375 + 3376 + 3377 +③ The deceleration point signal is valid when starting homing 3378 + 3379 +[[image:file:///C:\Users\Administrator\AppData\Local\Temp\ksohtml22584\wps31.png]] 3380 + 3381 +When starting to homing, HW = 1, it will directly start to homing at a forward low speed. After encountering the falling edge of HW, it will reverse and run at a reverse low speed. The first Z signal after encountering the rising edge of HW will stop. 3382 + 3383 +(13) P01-40=13 3384 + 3385 +Mechanical homing: Motor Z signal 3386 + 3387 +Deceleration point: Home switch (HW) 3388 + 3389 +① The deceleration point signal is invalid when starting homing, the reverse limit switch is not encountered 3390 + 3391 +[[image:file:///C:\Users\Administrator\AppData\Local\Temp\ksohtml22584\wps32.png]] 3392 + 3393 +When it starts to homing, HW=0, and it starts to homing at a reverse high speed. If it does not encounter the limit switch, after encountering the rising edge of HW, slow down and run at a reverse low speed. After encountering the falling edge of HW, reverse and run at a forward low speed, and stop at the first Z signal after encountering the rising edge of HW. 3394 + 3395 + 3396 +① The deceleration point signal is invalid when starting homing, the reverse limit switch is encountered 3397 + 3398 +[[image:file:///C:\Users\Administrator\AppData\Local\Temp\ksohtml22584\wps33.png]] 3399 + 3400 +When it starts to homing, HW=0, it starts to homing at reverse high speed, encounters the limit switch, automatically reverses, runs at forward high speed, after encountering the rising edge of HW, decelerates and runs in reverse low speed, and encounters the falling edge of HW when running at reverse low speed, the first Z signal after encountering the rising edge of HW stops. 3401 + 3402 +③ The deceleration point signal is valid when starting homing 3403 + 3404 +[[image:file:///C:\Users\Administrator\AppData\Local\Temp\ksohtml22584\wps34.png]] 3405 + 3406 +When starting homing, HW=1 starts homing directly at reverse low speed. After encountering the falling edge of HW, the first Z signal after encountering the rising edge of HW stops in reverse and forward low speed operation; 3407 + 3408 + 3409 +(14) P01-40=14 3410 + 3411 +Mechanical homing: Motor Z signal 3412 + 3413 +Deceleration point: Home switch (HW) 3414 + 3415 +① The deceleration point signal is invalid when starting homing, the reverse limit switch is not encountered 3416 + 3417 +[[image:file:///C:\Users\Administrator\AppData\Local\Temp\ksohtml22584\wps35.png]] 3418 + 3419 +When it starts to homing, HW=0, it starts to homing at reverse high speed, and does not encounter the limit switch. After encountering the rising edge of HW, it decelerates and runs at reverse low speed. After encountering the falling edge of HW, it continues to run at reverse low speed, and then the first Z signal encountered stops. 3420 + 3421 + 3422 +① The deceleration point signal is invalid when starting homing, the reverse limit switch is encountered 3423 + 3424 +[[image:file:///C:\Users\Administrator\AppData\Local\Temp\ksohtml22584\wps36.png]] 3425 + 3426 +When it starts to homing, HW = 0, it starts to homing at a reverse high speed, encounters a limit switch, automatically reverses, runs at a forward high speed, encounters a rising edge of HW, decelerates and runs in a reverse direction, and stops the first Z signal after encountering a falling edge of HW at a reverse low speed. 3427 + 3428 + 3429 +③ The deceleration point signal is valid when starting homing 3430 + 3431 +[[image:file:///C:\Users\Administrator\AppData\Local\Temp\ksohtml22584\wps37.png]] 3432 + 3433 +When starting homing, HW=1, then directly reverse the low speed to start homing, and stop the first Z signal after encountering the falling edge of HW; 3434 + 3435 + 3436 +(15) P01-40=17 3437 + 3438 +Mechanical homing: Negative overrun switch (NOT) 3439 + 3440 +Deceleration point: Negative overrun switch (NOT) 3441 + 3442 +① The deceleration point signal is invalid when starting homing 3443 + 3444 +[[image:file:///C:\Users\Administrator\AppData\Local\Temp\ksohtml22584\wps38.png]] 3445 + 3446 +When it starts to homing, NOT = 0, it starts to homing at a high speed in the reverse direction. After encountering the rising edge of NOT, it decelerates and reverses the direction, runs at a low speed in the forward direction, and stops after encountering the falling edge of NOT. 3447 + 3448 + 3449 +② The deceleration point signal is valid when starting homing 3450 + 3451 +[[image:file:///C:\Users\Administrator\AppData\Local\Temp\ksohtml22584\wps39.png]] 3452 + 3453 +When starting homing, NOT=1, start homing directly at low speed, and stop after encountering the falling edge of NOT. 3454 + 3455 + 3456 +(16) P01-40=18 3457 + 3458 +Mechanical homing: Positive overrun switch (POT) 3459 + 3460 +Deceleration point: Positive overrun switch (POT) 3461 + 3462 +① The deceleration point signal is invalid when starting homing 3463 + 3464 +[[image:file:///C:\Users\Administrator\AppData\Local\Temp\ksohtml22584\wps40.png]] 3465 + 3466 +When it starts to return to zero, POT=0, it starts to homing at a forward high speed, after encountering the rising edge of POT, it decelerates and reverses, runs at a reverse low speed, and stops after encountering the falling edge of POT. 3467 + 3468 + 3469 +② The deceleration point signal is valid when starting homing 3470 + 3471 +[[image:file:///C:\Users\Administrator\AppData\Local\Temp\ksohtml22584\wps41.png]] 3472 + 3473 +When starting homing, POT=1, start homing at low speed in reverse directly, and stop when encountering POT falling edge; 3474 + 3475 + 3476 + 3477 +(17) P01-40=19 3478 + 3479 +Mechanical homing: Home switch (HW) 3480 + 3481 +Deceleration point: Home switch (HW) 3482 + 3483 +① The deceleration point signal is invalid when starting homing 3484 + 3485 +[[image:file:///C:\Users\Administrator\AppData\Local\Temp\ksohtml22584\wps42.png]] 3486 + 3487 +When it starts to homing, HW=0, and it starts to homing at a forward high speed. After encountering the rising edge of HW, it decelerates and reverses the direction, runs at a reverse low speed, and stops when encountering the falling edge of HW. 3488 + 3489 + 3490 +② The deceleration point signal is valid when starting homing 3491 + 3492 +[[image:file:///C:\Users\Administrator\AppData\Local\Temp\ksohtml22584\wps43.png]] 3493 + 3494 +When starting homing, HW=1, start homing at low speed in reverse directly, and stop when encountering HW falling edge; 3495 + 3496 + 3497 +(18) P01-40=20 3498 + 3499 +Mechanical homing: Home switch (HW) 3500 + 3501 +Deceleration point: Home switch (HW) 3502 + 3503 +① The deceleration point signal is invalid when starting homing 3504 + 3505 +[[image:file:///C:\Users\Administrator\AppData\Local\Temp\ksohtml22584\wps44.png]] 3506 + 3507 +When starting to homing, HW=0, directly start to homing at low speed, and stop after encountering the rising edge of HW; 3508 + 3509 + 3510 +② The deceleration point signal is valid when starting homing 3511 + 3512 +[[image:file:///C:\Users\Administrator\AppData\Local\Temp\ksohtml22584\wps45.png]] 3513 + 3514 +When starting to homing, HW = 1, start to homing at a high speed in the reverse direction. After encountering the falling edge of HW, slow down and reverse the direction, run at a low speed in the forward direction, and stop when encountering the rising edge of HW. 3515 + 3516 + 3517 +(19) P01-40=21 3518 + 3519 +Mechanical homing: Home switch (HW) 3520 + 3521 +Deceleration point: Home switch (HW) 3522 + 3523 +① The deceleration point signal is invalid when starting homing 3524 + 3525 +[[image:file:///C:\Users\Administrator\AppData\Local\Temp\ksohtml22584\wps46.png]] 3526 + 3527 +When it starts to homing, HW=0, it starts to homing at a reverse high speed. After encountering the rising edge of HW, it decelerates and reverses the direction, runs at a forward low speed, and stops when encountering the falling edge of HW. 3528 + 3529 + 3530 +② The deceleration point signal is valid when starting homing 3531 + 3532 +[[image:file:///C:\Users\Administrator\AppData\Local\Temp\ksohtml22584\wps47.png]] 3533 + 3534 +When starting back to zero, HW=1, it will start homing directly at low speed, and stop after encountering the falling edge of HW; 3535 + 3536 + 3537 +(20) P01-40=22 3538 + 3539 +Mechanical homing: Home switch (HW) 3540 + 3541 +Deceleration point: Home switch (HW) 3542 + 3543 +① The deceleration point signal is invalid when starting homing 3544 + 3545 +[[image:file:///C:\Users\Administrator\AppData\Local\Temp\ksohtml22584\wps48.png]] 3546 + 3547 +When starting to homing, HW=0, directly reverse low speed starts to homing, and stops when encountering HW rising edge; 3548 + 3549 + 3550 +Deceleration point signal is valid when homing start 3551 + 3552 +[[image:file:///C:\Users\Administrator\AppData\Local\Temp\ksohtml22584\wps49.jpg]] 3553 + 3554 +When starting to homing, HW=1, start to homing at a forward high speed, after encountering the falling edge of HW, slow down and reverse, run at a reverse low speed, and stop when encountering the rising edge of HW. 3555 + 3556 + 3557 +(21) P01-40=23 3558 + 3559 +Mechanical homing: Home switch (HW) 3560 + 3561 +Deceleration point: Home switch (HW) 3562 + 3563 +① The deceleration point signal is invalid when starting homing, the forward limit switch is not encountered 3564 + 3565 +[[image:file:///C:\Users\Administrator\AppData\Local\Temp\ksohtml22584\wps50.png]] 3566 + 3567 +When it starts to homing, HW = 0, it starts to homing at a forward high speed, and does not encounter a limit switch. After encountering the rising edge of HW, it decelerates and reverses, runs at a reverse low speed, and stops when encountering the falling edge of HW. 3568 + 3569 + 3570 +① The deceleration point signal is invalid when starting homing, the forward limit switch is encountered 3571 + 3572 +[[image:file:///C:\Users\Administrator\AppData\Local\Temp\ksohtml22584\wps51.png]] 3573 + 3574 +When you start homing, HW = 0, start homing at a forward high speed. When encountering the limit switch, it will automatically reverse and run at a reverse high speed. After encountering the rising edge of HW, slow down, continue to run at reverse low speed, and stop when encountering the HW falling edge. 3575 + 3576 + 3577 + 3578 +③ The deceleration point signal is valid when starting homing 3579 + 3580 +[[image:file:///C:\Users\Administrator\AppData\Local\Temp\ksohtml22584\wps52.png]] 3581 + 3582 +When it starts to homing, HW=1, it starts to homing at a reverse low speed, and stops when it encounters the falling edge of HW. 3583 + 3584 + 3585 +(22) P01-40=24 3586 + 3587 +Mechanical homing: Home switch (HW) 3588 + 3589 +Deceleration point: Home switch (HW) 3590 + 3591 +① The deceleration point signal is invalid when starting homing, the forward limit switch is not encountered 3592 + 3593 +[[image:file:///C:\Users\Administrator\AppData\Local\Temp\ksohtml22584\wps53.png]] 3594 + 3595 +When it starts to homing, HW = 0, it starts to homing at a forward high speed, and does not encounter a limit switch. After encountering the rising edge of HW, it decelerates and reverses, and runs at a reverse low speed. After encountering the falling edge of HW, it reverses and runs at a forward low speed, and stops when encountering the rising edge of HW. 3596 + 3597 + 3598 +① The deceleration point signal is invalid when starting homing, the forward limit switch is encountered 3599 + 3600 +[[image:file:///C:\Users\Administrator\AppData\Local\Temp\ksohtml22584\wps54.png]] 3601 + 3602 +When it starts to homing, HW = 0, it starts to homing at forward high speed, encounters the limit switch, automatically reverses, runs at reverse high speed, encounters the rising edge of HW, decelerates and runs at reverse low speed, encounters the falling edge of HW, reverses, runs at forward low speed, and stops when encountering the rising edge of HW. 3603 + 3604 + 3605 +③ The deceleration point signal is valid when starting homing 3606 + 3607 +[[image:file:///C:\Users\Administrator\AppData\Local\Temp\ksohtml22584\wps55.png]] 3608 + 3609 +When starting with homing, HW = 1, it will directly reverse the low speed and start to homing. After encountering the falling edge of HW, it will reverse the direction and run at a forward low speed, and stop when encountering the rising edge of HW. 3610 + 3611 + 3612 +(23) P01-40=25 3613 + 3614 +Mechanical homing: Home switch (HW) 3615 + 3616 +Deceleration point: Home switch (HW) 3617 + 3618 +① The deceleration point signal is invalid when starting homing, the forward limit switch is not encountered 3619 + 3620 +[[image:file:///C:\Users\Administrator\AppData\Local\Temp\ksohtml22584\wps56.png]] 3621 + 3622 +When it starts to homing, HW=0, it starts to homing at a forward high speed, and does not encounter a limit switch. After encountering the rising edge of HW, it decelerates and runs at a forward low speed. After encountering the falling edge of HW, it reverses and runs at a reverse low speed, and stops when encountering the rising edge of HW. 3623 + 3624 + 3625 +① The deceleration point signal is invalid when starting homing, the forward limit switch is encountered 3626 + 3627 +[[image:file:///C:\Users\Administrator\AppData\Local\Temp\ksohtml22584\wps57.png]] 3628 + 3629 +When it starts to homing, HW=0, it starts to homing at forward high speed, encounters the limit switch, automatically reverses, and runs at reverse high speed. After encountering the rising edge of HW, decelerate and reverse to resume forward operation. After encountering the falling edge of HW at forward low speed, reverse. When running at reverse low speed, stop when encountering the rising edge of HW. 3630 + 3631 + 3632 +③ The deceleration point signal is valid when starting homing 3633 + 3634 +[[image:file:///C:\Users\Administrator\AppData\Local\Temp\ksohtml22584\wps58.png]] 3635 + 3636 +When starting homing, when HW=1, it starts to homing directly at low speed in the forward direction. After encountering the falling edge of HW, it stops at the rising edge of HW in the reverse low speed operation 3637 + 3638 + 3639 +(24) P01-40=26 3640 + 3641 +Mechanical homing: Home switch (HW) 3642 + 3643 +Deceleration point: Home switch (HW) 3644 + 3645 +① The deceleration point signal is invalid when starting homing, the forward limit switch is not encountered 3646 + 3647 +[[image:file:///C:\Users\Administrator\AppData\Local\Temp\ksohtml22584\wps59.png]] 3648 + 3649 +When it starts to homing, HW=0, it starts to homing at a forward high speed, and does not encounter a limit switch. After encountering the rising edge of HW, it decelerates, runs at a forward low speed, and stops when encountering the falling edge of HW. 3650 + 3651 + 3652 +① The deceleration point signal is invalid when starting homing, the forward limit switch is encountered 3653 + 3654 +[[image:file:///C:\Users\Administrator\AppData\Local\Temp\ksohtml22584\wps60.png]] 3655 + 3656 +When it starts to homing, HW=0, it starts to homing at forward high speed, encounters the limit switch, automatically reverses, and runs at reverse high speed. After encountering the rising edge of HW, decelerates and reverses to resume forward operation, and stops when encountering the falling edge of HW at forward low speed. 3657 + 3658 + 3659 +③ The deceleration point signal is valid when starting homing 3660 + 3661 +[[image:file:///C:\Users\Administrator\AppData\Local\Temp\ksohtml22584\wps61.png]] 3662 + 3663 +When starting homing, HW=1, it will start homing directly at low speed, and stop when encountering HW falling edge; 3664 + 3665 + 3666 +(25) P01-40=27 3667 + 3668 +Mechanical homing: Home switch (HW) 3669 + 3670 +Deceleration point: Home switch (HW) 3671 + 3672 +① The deceleration point signal is invalid when starting homing, the reverse limit switch is not encountered 3673 + 3674 +[[image:file:///C:\Users\Administrator\AppData\Local\Temp\ksohtml22584\wps62.png]] 3675 + 3676 +When it starts to homing, HW=0, it starts to homing at a reverse high speed, and does not encounter a limit switch. After encountering the rising edge of HW, it decelerates and reverses the direction, runs at a forward low speed, and stops when encountering the falling edge of HW. 3677 + 3678 + 3679 +① The deceleration point signal is invalid when starting homing, the reverse limit switch is encountered 3680 + 3681 +[[image:file:///C:\Users\Administrator\AppData\Local\Temp\ksohtml22584\wps63.png]] 3682 + 3683 +When it starts to homing, HW=0, it starts to homing at a reverse high speed. When it encounters a limit switch, it automatically reverses and runs at a forward high speed. When it encounters a rising edge of HW, it decelerates and continues to run at a forward low speed. When it encounters a falling edge of HW, it stops. 3684 + 3685 + 3686 +③ The deceleration point signal is valid when starting homing 3687 + 3688 +[[image:file:///C:\Users\Administrator\AppData\Local\Temp\ksohtml22584\wps64.png]] 3689 + 3690 +When starting homing, HW=1, it will start homing directly at low speed, and stop when encountering HW falling edge; 3691 + 3692 + 3693 +(26) P01-40=28 3694 + 3695 +Mechanical homing: Home switch (HW) 3696 + 3697 +Deceleration point: Home switch (HW) 3698 + 3699 +① The deceleration point signal is invalid when starting homing, the reverse limit switch is not encountered 3700 + 3701 +[[image:file:///C:\Users\Administrator\AppData\Local\Temp\ksohtml22584\wps65.png]] 3702 + 3703 +When it starts to homing, HW=0, it starts to homing at a reverse high speed, and does not encounter a limit switch. After encountering the rising edge of HW, it decelerates and reverses, and runs at a forward low speed. After encountering the falling edge of HW, it reverses and runs at a reverse low speed, and stops when encountering the rising edge of HW. 3704 + 3705 + 3706 +① The deceleration point signal is invalid when starting homing, the reverse limit switch is encountered 3707 + 3708 +[[image:file:///C:\Users\Administrator\AppData\Local\Temp\ksohtml22584\wps66.png]] 3709 + 3710 +When it starts to homing, HW=0, it starts to homing at a reverse high speed. When encountering a limit switch, it automatically reverses and runs at a forward high speed. When encountering a rising edge of HW, it decelerates and runs at a forward low speed. When encountering a falling edge of HW, it reverses and runs at a reverse low speed. When encountering a rising edge of HW, it stops. 3711 + 3712 + 3713 +③ The deceleration point signal is valid when starting homing 3714 + 3715 +[[image:file:///C:\Users\Administrator\AppData\Local\Temp\ksohtml22584\wps67.png]] 3716 + 3717 +When starting with homing, HW = 1, it will directly start to homing at a forward low speed. After encountering the falling edge of HW, it will reverse and run at a reverse low speed. When encountering the rising edge of HW, it will stop. 3718 + 3719 + 3720 +(27) P01-40=29 3721 + 3722 +Mechanical homing: Home switch (HW) 3723 + 3724 +Deceleration point: Home switch (HW) 3725 + 3726 +① The deceleration point signal is invalid when starting homing, the reverse limit switch is not encountered 3727 + 3728 +[[image:file:///C:\Users\Administrator\AppData\Local\Temp\ksohtml22584\wps68.png]] 3729 + 3730 +When it starts to homing, HW = 0, it starts to homing at a reverse high speed, and does not encounter a limit switch. After encountering the rising edge of HW, it decelerates and runs at a reverse low speed. After encountering the falling edge of HW, it reverses and runs at a forward low speed, and stops when encountering the rising edge of HW. 3731 + 3732 + 3733 +① The deceleration point signal is invalid when starting homing, the reverse limit switch is encountered 3734 + 3735 +[[image:file:///C:\Users\Administrator\AppData\Local\Temp\ksohtml22584\wps69.png]] 3736 + 3737 +When it starts to homing, HW=0, it starts to homing at a reverse high speed. When it encounters a limit switch, it automatically reverses and runs at a forward high speed. After encountering a rising edge of HW, it decelerates and runs in a reverse low speed. After encountering a falling edge of HW, it reverses. When running at a forward low speed, it stops when it encounters a rising edge of HW. 3738 + 3739 +③ The deceleration point signal is valid when starting homing 3740 + 3741 +[[image:file:///C:\Users\Administrator\AppData\Local\Temp\ksohtml22584\wps70.png]] 3742 + 3743 +When starting homing, when HW=1, it starts to homing directly at low speed in reverse direction. After encountering the falling edge of HW, it stops when running at low speed in reverse direction and forward direction and encountering the rising edge of HW 3744 + 3745 + 3746 +(28) P01-40=30 3747 + 3748 +Mechanical homing: Home switch (HW) 3749 + 3750 +Deceleration point: Home switch (HW) 3751 + 3752 +① The deceleration point signal is invalid when starting homing, the reverse limit switch is not encountered 3753 + 3754 +[[image:file:///C:\Users\Administrator\AppData\Local\Temp\ksohtml22584\wps71.png]] 3755 + 3756 +When it starts to homing, HW=0, it starts to homing at reverse high speed, and does not encounter the limit switch. After encountering the rising edge of HW, it decelerates, runs at reverse low speed, and stops when encountering the falling edge of HW. 3757 + 3758 + 3759 +① The deceleration point signal is invalid when starting homing, the reverse limit switch is encountered 3760 + 3761 +[[image:file:///C:\Users\Administrator\AppData\Local\Temp\ksohtml22584\wps72.png]] 3762 + 3763 +When it starts to homing, HW=0, it starts to homing at a reverse high speed. When it encounters a limit switch, it automatically reverses and runs at a forward high speed. When it encounters a rising edge of HW, it decelerates and runs in a reverse low speed. When it encounters a falling edge of HW, it stops. 3764 + 3765 + 3766 +③ The deceleration point signal is valid when starting homing 3767 + 3768 +[[image:file:///C:\Users\Administrator\AppData\Local\Temp\ksohtml22584\wps73.png]] 3769 + 3770 +When starting homing, HW=1, start homing at low speed in reverse directly, and stop when encountering HW falling edge; 3771 + 3772 + 3773 +(29) P01-40=33 and P01-40=34 3774 + 3775 +Mechanical homing: Z signal. 3776 + 3777 +Deceleration point: None 3778 + 3779 +Homing mode 33: Reverse low speed operation, stop the first Z signal encountered 3780 + 3781 +Homing mode 34: running at low speed in forward direction, stopping the first Z signal encountered 3782 + 3783 +[[image:file:///C:\Users\Administrator\AppData\Local\Temp\ksohtml22584\wps74.png]] 3784 + 3785 + 3786 +(30) P01-40=35 3787 + 3788 +Homing mode 35, taking the current position as the mechanical homing, after triggering the homing (P01-39: 0x00→0x01/0x00 → 0x02); 3789 + 3790 +After the homing is completed, according to the set value of P10-08 (homing bias compensation), P10-06 (encoder multi-turn reset operation) is executed. 3791 + 3792 + 3793 +