Changes for page 03 Software

Last modified by Devin Chen on 2025/01/06 15:48

From version 55.1
edited by Theodore Xu
on 2023/12/05 14:59
Change comment: There is no comment for this version
To version 56.1
edited by Theodore Xu
on 2024/01/18 09:31
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -1,6 +1,79 @@
1 1  (% style="width:965.841px" %)
2 2  |=(% scope="row" style="width: 158px;" %)Software|=(% style="width: 146px;" %)Version|=(% style="width: 122.37px;" %)Download|=(% style="width: 510.974px;" %)Description
3 -|=(% colspan="1" style="width: 158px;" %)V-NET Client|(% style="width:146px" %)230323|(% style="width:122.37px" %)[[Link>>https://ftp.we-con.com.cn/Download/WIKI/V-BOX/Software/V-NET%20Client%20setup23032302.zip]]|(% style="width:510.974px" %)(((
3 +|=(% colspan="1" style="width: 158px;" %)V-NET Client|(% style="width:146px" %)(((
4 +**3.0.54**
5 +)))|(% style="width:122.37px" %)[[Link>>https://ftp.we-con.com.cn/Download/WIKI/V-BOX/Software/V-NET%20Client%20setup23032302.zip]]|(% style="width:510.974px" %)(((
6 +**Update Log of version 3.0.54**
7 +
8 +**Update content**
9 +
10 +Change the company name
11 +
12 +**Notice**
13 +
14 +**Compatibility issues**
15 +
16 +Misreported virus of antivirus software:
17 +
18 +1. When installing and running the software, it may be intercepted by antivirus software.
19 +
20 +2. When the program runs, it needs to use some sensitive operations, such as writing Windows registry, etc. These operations can be recognized by antivirus software as not allowed operation, so that it is intercepted;
21 +
22 +3.Please close the antivirus software to run this software, or add the Client software to white list.
23 +
24 +The problem will be continue followed up and investigated.
25 +
26 +
27 +**Virtual deployment function in the neutral software**
28 +
29 +~1. In this version, neutral software needs to import a certificate to be used normally, and the software provides a neutral general certificate.
30 +
31 +2. The certificate is incompatible with that exported by software “V-NET Access”, and the certificate needs to be downloaded again in virtual administrator account.
32 +
33 +3. Update the neutral general certificate to "IIoT Client Universal Neutral Certificate_231025. ce”. For the customer who exported the certificate before November 2023, please download the certificate in the virtual administrator account again, and then used this software.
34 +
35 +**Precautions**
36 +
37 +~1. The **remote download** function in V-NET Access is transferred to the **device pass-through** function in V-Net Client.
38 +
39 +2. Single sign-on problem: The account only supports single sign-on on V-NET/neutral software, so two computers cannot log in the same account to use VPN pass-through at the same time.
40 +
41 +3. If the pop-up prompts "wpcap.dll was not found" when opening the software, please find "npcap-1. 71. exe" in the installation directory. Enable the option "Install Npcap in WinPcap API-compatible Mode" when installing.
42 +
43 +**Software information**
44 +
45 +Upgrade time: 2024/01/03
46 +
47 +Software version: V3.0.54
48 +
49 +Firmware version:
50 +
51 +H01-1.0.1.23102001
52 +
53 +S01-1.0.1.23102001
54 +
55 +E01-1.0.4.23102001
56 +
57 +E02-1.0.1.23102001
58 +)))
59 +|=(% colspan="1" style="width: 158px;" %)Cloud Client|(% style="width:146px" %)230323|(% style="width:122.37px" %)[[Link>>https://ftp.we-con.com.cn/Download/WIKI/V-BOX/Software/Cloud%20Client%20setup23032302.zip]]|(% style="width:510.974px" %)
60 +|=(% colspan="1" rowspan="2" style="width: 158px;" %)**V-NET APP**|(% style="width:146px" %)Android 2.2.7|(% style="width:122.37px" %)[[Link>>https://ftp.we-con.com.cn/Download/Software/V-Net-V2.2.7-202307281055.apk]]|(% style="width:510.974px" %)(((
61 +**Update Log of Test version**
62 +
63 +* Bug of Google Map cannot display;
64 +* Modifiedable alias name for V-Box and HMI;
65 +* Remote monitoring screen now support rotation;
66 +* Abnormal display Web SCADA BUG;
67 +* New columns for Alarm record: Confirm time, Confirm user;
68 +* Monitor V-NET and cloud scada by android APP
69 +)))
70 +|(% style="width:146px" %)(((
71 +TV version
72 +
73 +Android 2.2.5
74 +)))|(% style="width:122.37px" %)[[Link>>https://ftp.we-con.com.cn/Download/WIKI/V-BOX/Software/V-Net-TV-V2.2.5-202309041821.apk]]|(% style="width:510.974px" %)
75 +|=(% colspan="1" style="width: 158px;" %)Old version |(% style="width:146px" %) |(% style="width:122.37px" %) |(% style="width:122.37px" %)
76 +|=(% colspan="1" style="width: 158px;" %)V-NET Client|(% style="width:146px" %)230323|(% style="width:122.37px" %)[[Link>>https://ftp.we-con.com.cn/Download/WIKI/V-BOX/Software/V-NET%20Client%20setup23032302.zip]]|(% style="width:122.37px" %)(((
4 4  **Update Log of Release version 3.0.37**
5 5  
6 6  **Bugs fixed**
... ... @@ -56,46 +56,3 @@
56 56  If the pop up prompt "**The application was unable to start(0xc000007b)**" when you open the software, please also install "npcap-1. 71. exe";
57 57  )))
58 58  )))
59 -|=(% colspan="1" style="width: 158px;" %)Cloud Client|(% style="width:146px" %)230323|(% style="width:122.37px" %)[[Link>>https://ftp.we-con.com.cn/Download/WIKI/V-BOX/Software/Cloud%20Client%20setup23032302.zip]]|(% style="width:510.974px" %)
60 -|=(% colspan="1" rowspan="1" style="width: 158px;" %)**V-NET Access PC software**|(% colspan="1" rowspan="1" style="width:146px" %)20220628|(% style="width:122.37px" %)[[Link>>https://ftp.we-con.com.cn/Download/Software/V-NET%20Access20220628.zip]]|(% style="width:510.974px" %)(((
61 -Configure VBOX connect with VNET and pass through and network configuration
62 -
63 -(% class="wikigeneratedid" id="HUpdateLogofA0Releaseversion20220628" %)
64 -**Update Log of Release version 20220628**
65 -
66 -**V-Box Firmware**
67 -
68 -* Bug fixed: Some H-SG cannot use 4G normally after upgrades;
69 -* Optimize the firmware update method;
70 -
71 -**PC Client**
72 -
73 -* Bug fixed: Ethernet pass through cannot be used;
74 -* Bug fixed: For the trigger type collection of device communication addresses, the data collected for the first time may be offline state;
75 -* Bug fixed: 4G ICCID reporting error;
76 -* Bug fixed: When RTC backup power supply is insufficient, the timestamp of historical data uploading is inaccurate;
77 -* Bug fixed: On OpenCloud mode, the collected value of the string type address is empty;
78 -* Bug fixed: Longitude and latitude positioning may be inaccurate;
79 -* When download the Network configuration, the software would not ask firmware updates anymore (**Suggest update the firmware through Ethernet**);
80 -* Monitoring tag reset function;
81 -
82 -(% class="wikigeneratedid" id="HImportantReminder" %)
83 -**Important Reminder**
84 -
85 -If the firmware version in V-Box is old (earlier than 1.21061701), and directly use the lastest release version (Release Build 2022-06-28 V2.3.38) of V-NET Access to upgrade, there will be an exception of "update failed" or "unrecognized device after update". Please use the release version 20210617(Release Build 2021-06-17 V2.2.94) to update first, and then use the lastest one to upgrade.
86 -)))
87 -|=(% colspan="1" rowspan="3" style="width: 158px;" %)**V-NET APP**|(% style="width:146px" %)Android 2.2.7|(% style="width:122.37px" %)[[Link>>https://ftp.we-con.com.cn/Download/Software/V-Net-V2.2.7-202307281055.apk]]|(% style="width:510.974px" %)(((
88 -**Update Log of Test version**
89 -
90 -* Bug of Google Map cannot display;
91 -* Modifiedable alias name for V-Box and HMI;
92 -* Remote monitoring screen now support rotation;
93 -* Abnormal display Web SCADA BUG;
94 -* New columns for Alarm record: Confirm time, Confirm user;
95 -* Monitor V-NET and cloud scada by android APP
96 -)))
97 -|(% style="width:146px" %)(((
98 -TV version
99 -
100 -Android 2.2.5
101 -)))|(% style="width:122.37px" %)[[Link>>https://ftp.we-con.com.cn/Download/WIKI/V-BOX/Software/V-Net-TV-V2.2.5-202309041821.apk]]|(% style="width:510.974px" %)