Changes for page 03 Software
Last modified by Devin Chen on 2025/03/22 16:13
Summary
-
Page properties (2 modified, 0 added, 0 removed)
Details
- Page properties
-
- Author
-
... ... @@ -1,1 +1,1 @@ 1 -XWiki. DevinChen1 +XWiki.Stone - Content
-
... ... @@ -1,130 +1,79 @@ 1 -(% style="width:965.841px" %) 2 -|=(% scope="row" style="width: 158px;" %)Software|=(% style="width: 146px;" %)Version|=(% style="width: 122.37px;" %)Download|=(% style="width: 510.974px;" %)Description 3 -|=(% colspan="1" style="width: 158px;" %)V-NET Client|(% style="width:146px" %)((( 4 -**3.0.54** 5 -)))|(% style="width:122.37px" %)[[Link>>https://ftp.we-con.com.cn/Download/WIKI/V-BOX/Software/V-NET%20Client%20setup240103.zip]]|(% style="width:510.974px" %)((( 6 -**Update Log of version 3.0.54** 1 += **1 V-BOX PC software** = 7 7 8 - **Updatecontent**3 +== Ver: 20220628 == 9 9 10 -C hangethecompanyname5 +Configure VBOX connect with VNET and pass through and network configuration 11 11 12 -**Notice** 7 +(% class="wikigeneratedid" id="HUpdateLogofA0Releaseversion20220628" %) 8 +**Update Log of Release version 20220628** 13 13 14 -** Compatibilityissues**10 +**V-Box Firmware** 15 15 16 - Misreportedvirusofantivirussoftware:12 +1) Bug fixed: Some H-SG cannot use 4G normally after upgrades; 17 17 18 - 1. Wheninstalling and runningthesoftware,itmay be interceptedbyantivirussoftware.14 +2) Optimize the firmware update method; 19 19 20 - 2.When the program runs,it needs to use some sensitive operations, such as writing Windows registry, etc. These operations can be recognized by antivirus software as not allowed operation, so that it is intercepted;16 +**PC Client** 21 21 22 - 3.Pleaseclose the antivirussoftwareorunhissoftware,or add theClient softwareto whitelist.18 +1) Bug fixed: Ethernet pass through cannot be used; 23 23 24 - The problemwillbe continuefollowedupandinvestigated.20 +2) Bug fixed: For the trigger type collection of device communication addresses, the data collected for the first time may be offline state; 25 25 22 +3) Bug fixed: 4G ICCID reporting error; 26 26 27 - **Virtualdeploymentfunctionintheneutralsoftware**24 +4) Bug fixed: When RTC backup power supply is insufficient, the timestamp of historical data uploading is inaccurate; 28 28 29 - ~1.Inthis version,neutralsoftware needsto importacertificateto beusednormally,andthe softwareprovidesaneutral generalcertificate.26 +5) Bug fixed: On OpenCloud mode, the collected value of the string type address is empty; 30 30 31 - 2.Thecertificate is incompatible with that exportedby software“V-NET Access”,and the certificateneedsbe downloaded againin virtualadministrator account.28 +6) Bug fixed: Longitude and latitude positioning may be inaccurate; 32 32 33 - 3.Update theeutralgeneralcertificate to"IIoT Client Universal Neutral Certificate_231025. ce”. Forthecustomer whoexportedthecertificate beforeNovember 2023,pleasedownload thecertificateinthevirtualadministrator account again,andthenusedthis software.30 +6) When download the Network configuration, the software would not ask firmware updates anymore (**Suggest update the firmware through Ethernet**); 34 34 35 - **Precautions**32 +7) Monitoring tag reset function; 36 36 37 -* The **remote download** function in V-NET Access is transferred to the **device pass-through** function in V-Net Client. 38 -* Single sign-on problem: The account only supports single sign-on on V-NET/neutral software, so two computers cannot log in the same account to use VPN pass-through at the same time. 39 -* ((( 40 -If the pop up prompt "**wpcap.dll was not found**" when you open the software, please find "npcap-1. 71. exe" in the installation directory. Enable the option "Install Npcap in WinPcap API-compatible Mode" when installing; 41 -))) 34 +=== Firmware version === 42 42 43 - **Softwareinformation**36 +[[Download link>>https://ftp.we-con.com.cn/Download/Software/V-NET%20Access20220628.zip]] 44 44 45 -Upgrade time: 2024/01/03 38 +* H01-1.0.1.22062801 39 +* S01-1.0.1.22062801 40 +* E01-1.0.4.22062801 41 +* E02-1.0.1.22062801 46 46 47 -Firmware version: 43 +(% class="wikigeneratedid" id="HImportantReminder" %) 44 +**Important Reminder** 48 48 49 - H01-1.0.1.2310200146 +If the firmware version in V-Box is old (earlier than 1.21061701), and directly use the lastest release version (Release Build 2022-06-28 V2.3.38) of V-NET Access to upgrade, there will be an exception of "update failed" or "unrecognized device after update". Please use the release version 20210617(Release Build 2021-06-17 V2.2.94) to update first, and then use the lastest one to upgrade. 50 50 51 - S01-1.0.1.2310200148 +== Ver: 20210617 == 52 52 53 - E01-1.0.4.2310200150 +[[Old Version Download 2021-06-17>>https://ftp.we-con.com.cn/Download/Software/V-NET%20Access20210617.zip]] 54 54 55 -E02-1.0.1.23102001 56 -))) 57 -|=(% colspan="1" style="width: 158px;" %)Cloud Client|(% style="width:146px" %)230323|(% style="width:122.37px" %)[[Link>>https://ftp.we-con.com.cn/Download/WIKI/V-BOX/Software/Cloud%20Client%20setup23032302.zip]]|(% style="width:510.974px" %) 58 -|=(% colspan="1" rowspan="2" style="width: 158px;" %)**V-NET APP**|(% style="width:146px" %)Android 2.2.7|(% style="width:122.37px" %)[[Link>>https://ftp.we-con.com.cn/Download/Software/V-Net-V2.2.7-202307281055.apk]]|(% style="width:510.974px" %)((( 59 -**Update Log of Test version** 52 += **2 V-BOX APP** = 60 60 61 -* Bug of Google Map cannot display; 62 -* Modifiedable alias name for V-Box and HMI; 63 -* Remote monitoring screen now support rotation; 64 -* Abnormal display Web SCADA BUG; 65 -* New columns for Alarm record: Confirm time, Confirm user; 66 -* Monitor V-NET and cloud scada by android APP 67 -))) 68 -|(% style="width:146px" %)((( 69 -TV version 54 +== Android 2.2.1 == 70 70 71 -Android 2.2.5 72 -)))|(% style="width:122.37px" %)[[Link>>https://ftp.we-con.com.cn/Download/WIKI/V-BOX/Software/V-Net-TV-V2.2.5-202309041821.apk]]|(% style="width:510.974px" %) 73 -|=(% colspan="1" style="width: 158px;" %)Old version |(% style="width:146px" %) |(% style="width:122.37px" %) |(% style="width:122.37px" %) 74 -|=(% colspan="1" style="width: 158px;" %)V-NET Client|(% style="width:146px" %)**3.0.37**|(% style="width:122.37px" %)[[Link>>https://ftp.we-con.com.cn/Download/WIKI/V-BOX/Software/V-NET%20Client%20setup23032302.zip]]|(% style="width:122.37px" %)((( 75 -**Update Log of Release version 3.0.37** 56 +Monitor V-NET and cloud scada by android APP 76 76 77 -**Bugs fixed** 78 - 79 -**PC Client** 80 - 58 +(% class="wikigeneratedid" %) 81 81 ((( 82 -* IG HMI does not show 485_2 in the PLC pass-through page; 83 -* PLC Passthrough: Ethernet pass-through not working; 84 -* IP address error reporting problems on segment 0; 85 -* Spelling error problem in some pages; 60 +[[Download link>>https://ftp.we-con.com.cn/Download/Software/V-NET%20APP-2.2.1.zip ]] 86 86 ))) 87 87 88 -**V -BOXFirmware**63 += **3 WVPN tool** = 89 89 90 -* ((( 91 -None 92 -))) 65 +== Ver: 20220221 == 93 93 94 - **New functionsadded**67 +[[Download link>>https://ftp.we-con.com.cn/Download/WIKI/V-BOX/Software/WVpn_PCclient-0.3.21.22022101.zip]] 95 95 96 -* New registration on login page; 97 -* VPN pass-through adds UDP mode; 98 -* Software homepage add full screen/remove full screen; 69 += **4 OPC tool** = 99 99 100 - **Notice**71 +== Ver: 20211222 == 101 101 102 - Compatibility issues73 +[[Download link>>https://ftp.we-con.com.cn/Download/WIKI/V-BOX/Software/V-BOX%20OPCTool%20setup20211222.zip]] 103 103 104 -* Misreportedvirus of antivirus software:75 += **5 Cloud tool** = 105 105 106 -1. When installing and running the software, it may be intercepted by antivirus software; 107 -1. ((( 108 -When the program runs, it needs to use some sensitive operations, such as writing Windows registry, etc. These operations can be recognized by antivirus software as not allowed operation, so that it is intercepted; 109 -))) 110 -1. ((( 111 -Please close the antivirus software to run this software at present, or add the Client software to white list; 112 -))) 113 -1. ((( 114 -The problem will be continue followed up and investigated; 115 -))) 77 +== 20220628 == 116 116 117 -Precautions 118 - 119 -* The remote download function of V-NET Access software is transferred to the device pass-through function of V-Net Client software 120 -* ((( 121 -Single sign-on problem: The account only supports single sign-on on V-NET, so two computers cannot log in the same account at the same time; 122 -))) 123 -* ((( 124 -If the pop up prompt "**wpcap.dll was not found**" when you open the software, please find "npcap-1. 71. exe" in the installation directory. Enable the option "Install Npcap in WinPcap API-compatible Mode" when installing; 125 -))) 126 -* ((( 127 -If the pop up prompt "**The application was unable to start(0xc000007b)**" when you open the software, please also install "npcap-1. 71. exe"; 128 -))) 129 -))) 130 -|=(% colspan="1" style="width: 158px;" %)V-NET Access|(% style="width:146px" %) |(% style="width:122.37px" %)[[Link>>https://ftp.we-con.com.cn/Download/WIKI/V-BOX/Software/V-NET%20Access20220628.zip]]|(% style="width:122.37px" %) 79 +[[Download link>>https://drive.google.com/file/d/1NyGWtjgtPxvMQI08l6Y59it7Jo5vniKU/view?usp=sharing]]