@@ -1,20 +1,54 @@ |
1 |
|
-= {{id name="HDelta"/}}**Delta** = |
|
1 |
+(% class="wikigeneratedid" id="HDVPserial" %) |
|
2 |
+(% id="cke_bm_111267S" style="display:none" %)** ** |
2 |
2 |
|
3 |
|
-== {{id name="HDVPEthernet"/}}**DVP Ethernet** == |
|
4 |
+(% class="wikigeneratedid" %) |
|
5 |
+Supoort Series: DELTA DVP EH/ES/SS/EX/EH2/SV/SA/SC/SX |
4 |
4 |
|
5 |
|
-Supoort Series: DELTA DVP20/32/40/60ES200RE/200TE or any DVP models with built-in Ethernet port, DELTA DVPEN01-SL module |
|
7 |
+**V-BOX Settings** |
6 |
6 |
|
7 |
|
-**1)V-BOX Settings** |
|
9 |
+|=**Items**|=**Settings**|=**Note** |
|
10 |
+|Protocol|DELTA DVP PROTOCOL| |
|
11 |
+|Connection|RS232| |
|
12 |
+|Baud Rate|9600| |
|
13 |
+|Stop Bit|1| |
|
14 |
+|Data Bit|7| |
|
15 |
+|Parity|EVEN| |
|
16 |
+|Device No.|1| |
8 |
8 |
|
|
18 |
+**Address List** |
|
19 |
+ |
|
20 |
+|=**Type**|=**Device registers**|=**HMI registers**|=**Format**|=**Range**|=**Note** |
|
21 |
+|Bit|X|X|X d|0~~303237| |
|
22 |
+|Bit|Y|Y|Y d|0~~303237| |
|
23 |
+|Bit|M|M|M d|0~~99999| |
|
24 |
+|Bit|T|T|T d|0~~99999| |
|
25 |
+|Bit|C|C|T d|0~~99999| |
|
26 |
+|Bit|S|S|T d|0~~99999| |
|
27 |
+|Word|D|D|D d|0~~99999| |
|
28 |
+|Word|T|T|T d|0~~99999| |
|
29 |
+|Word|C|C|C d|0~~99999| |
|
30 |
+ |
|
31 |
+**Wiring Diagram** |
|
32 |
+ |
|
33 |
+[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_96f8e9b105b4268c.png||alt="Delta DVP PROTOCOLSerial232.png" height="247" width="400"]] |
|
34 |
+ |
|
35 |
+== **DVP Ethernet** == |
|
36 |
+ |
|
37 |
+Supported Series: Delta DVP ES2/EX2/SS2/SA2/SX2/SE Controller |
|
38 |
+ |
|
39 |
+**V-BOX Settings** |
|
40 |
+ |
9 |
9 |
|=**Items**|=**Settings**|=**Note** |
10 |
|
-|Protocol|DELTA DVP MODBUS TCP| |
|
42 |
+|Protocol|DELTA DVP Modbus TCP| |
11 |
11 |
|Connection|Ethernet| |
12 |
|
-|Port No.|502| |
13 |
|
-|Device No.|1| |
14 |
|
-|VBox Device No.|0| |
|
44 |
+|Port No.|502|Must be the same as the PLC setting |
|
45 |
+|PLC station No.|0|Must be the same as the PLC setting |
15 |
15 |
|
16 |
|
-**2)Address List ** |
|
47 |
+(% style="text-align:center" %) |
|
48 |
+[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_514e38138de7059.png||alt="DVPEthernetVNETPortocol.png" height="493" width="729"]] |
17 |
17 |
|
|
50 |
+**Address List ** |
|
51 |
+ |
18 |
18 |
|=**Type**|=**Device registers**|=**VBox registers**|=**Format**|=**Range**|=**Note** |
19 |
19 |
|Bit|X|X|X OOO|0~~377| |
20 |
20 |
|Bit|Y|Y|Y OOO|0~~377| |
... |
... |
@@ -29,15 +29,15 @@ |
29 |
29 |
|Word|C|C|CDDD|0~~199| |
30 |
30 |
|Double Word|HC|HC|HCDDD|200~~255| |
31 |
31 |
|
32 |
|
-**3) PLC Setting:** |
|
66 |
+**PLC Setting:** |
33 |
33 |
|
34 |
34 |
~1. Create new project in Delta WPL Soft, and click Setting to open the communication settings: |
35 |
35 |
|
36 |
|
-{{id name="IDVPEthernetWPLSoft2.png"/}}[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_c5e594a6b73bdd68.png||alt="DVPEthernetWPLSoft2.png" height="727" width="1366"]] |
|
70 |
+[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_c5e594a6b73bdd68.png||alt="DVPEthernetWPLSoft2.png" height="727" width="1366"]] |
37 |
37 |
|
38 |
38 |
2. Set up the communication type and PLC IP: |
39 |
39 |
|
40 |
|
-{{id name="IDVPEthernetSetup.png"/}}[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_92343d448762200c.png||alt="DVPEthernetSetup.png" height="592" width="346"]] |
|
74 |
+[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_92343d448762200c.png||alt="DVPEthernetSetup.png" height="592" width="346"]] |
41 |
41 |
|
42 |
42 |
3. Click OK and save the settings. Then click Communication on toolbar, then click Transfer Setup to open new window: |
43 |
43 |
|
... |
... |
@@ -45,55 +45,89 @@ |
45 |
45 |
|
46 |
46 |
4. Select Communication Mode as PC => PLC to download or select PC <=PLC to upload: |
47 |
47 |
|
48 |
|
-{{id name="IDVPEthernetPLCtoPC.png"/}}[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_ae301f5422be2294.png||alt="DVPEthernetPLCtoPC.png" height="303" width="308"]] |
|
82 |
+[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_ae301f5422be2294.png||alt="DVPEthernetPLCtoPC.png" height="303" width="308"]] |
49 |
49 |
|
50 |
50 |
5. Click Auto-Search Ethernet Module to find the PLC on the same LAN network: |
51 |
51 |
|
52 |
52 |
{{id name="IDVPEthernetAutoSearch.png"/}}[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_e2c32050bbe425bc.png||alt="DVPEthernetAutoSearch.png" height="723" width="1366"]] |
53 |
53 |
|
54 |
|
-**4) V-BOX Setting:** |
55 |
55 |
|
56 |
|
-Set the same IP address according to the setting from WPL Soft: |
|
89 |
+== **AS Series Serial** == |
57 |
57 |
|
58 |
|
-{{id name="IDVPEthernetVNETPortocol.png"/}}[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_514e38138de7059.png||alt="DVPEthernetVNETPortocol.png" height="493" width="729"]] |
|
91 |
+Supported Series: Delta AS200/AS300 |
59 |
59 |
|
60 |
|
-== {{id name="HDVPserial"/}}**DVP serial** == |
|
93 |
+**V-BOX Settings** |
61 |
61 |
|
62 |
|
-Supoort Series: DELTA DVP EH/ES/SS/EX/EH2/SV/SA/SC/SX |
|
95 |
+|**Item**|**Settings**|**Note** |
|
96 |
+|Protocol|DELTA AS300 MODBUS RTU| |
|
97 |
+|Connection|RS485| |
|
98 |
+|Baud rate|9600| |
|
99 |
+|Data bit|8| |
|
100 |
+|Parity|NONE| |
|
101 |
+|Stop bit|1| |
|
102 |
+|PLC station No.|1| |
63 |
63 |
|
64 |
|
-**1)V-BOX Settings** |
|
104 |
+**Address List** |
65 |
65 |
|
66 |
|
-|=**Items**|=**Settings**|=**Note** |
67 |
|
-|Protocol|DELTA DVP PROTOCOL| |
68 |
|
-|Connection|RS232| |
69 |
|
-|Baud Rate|9600| |
70 |
|
-|Stop Bit|1| |
71 |
|
-|Data Bit|7| |
72 |
|
-|Parity|EVEN| |
73 |
|
-|Device No.|1| |
|
106 |
+|=**Type**|=**Device registers**|=**Format**|=**Range**|=**Note** |
|
107 |
+|(% colspan="1" rowspan="9" %)Bit|X|Xdd.dd|0~~63.15|Read only |
|
108 |
+|Y|Ydd.dd|0~~63.15| |
|
109 |
+|D|Dddddd|0~~29999| |
|
110 |
+|M|Mdddd|0~~8191| |
|
111 |
+|SM|SMdddd|0~~4095| |
|
112 |
+|S|Sdddd|0~~2047| |
|
113 |
+|T|Tddd|0~~511| |
|
114 |
+|C|Cddd|0~~511| |
|
115 |
+|HC|HCddd|0~~255|Double Word |
|
116 |
+|(% colspan="1" rowspan="7" %)Word|X|Xdd|0~~63| |
|
117 |
+|Y|Ydd|0~~63| |
|
118 |
+|SR|SRdddd|0~~2047|Special register |
|
119 |
+|D|Dddddd|0~~29999| |
|
120 |
+|T|Tddd|0~~511| |
|
121 |
+|C|Cddd|0~~511| |
|
122 |
+|E|Ed|0~~9| |
74 |
74 |
|
75 |
|
-**2)Address List** |
|
124 |
+**PLC Settings** |
76 |
76 |
|
77 |
|
-|=**Type**|=**Device registers**|=**VBox registers**|=**Format**|=**Range**|=**Note** |
78 |
|
-|Bit|X|X|X OOOOOO|0~~303237| |
79 |
|
-|Bit|Y|Y|Y OOOOOO|0~~303237| |
80 |
|
-|Bit|M|M|MDDDDD|0~~99999| |
81 |
|
-|Bit|T|T|TDDDDD|0~~99999| |
82 |
|
-|Bit|C|C|CDDDDD|0~~99999| |
83 |
|
-|Bit|S|S|SDDDDD|0~~99999| |
84 |
|
-|Word|D|D|D DDDDD|0~~99999| |
85 |
|
-|Word|T|T|TDDDDD|0~~99999| |
86 |
|
-|Word|C|C|CDDD|0~~199| |
87 |
|
-|Double Word|C|C|CDDDDD|200~~99999| |
|
126 |
+Create project |
88 |
88 |
|
89 |
|
-**3)Wiring Diagram** |
|
128 |
+(% style="text-align:center" %) |
|
129 |
+[[image:台达1.png]] |
90 |
90 |
|
91 |
|
-{{id name="IDeltaDVPPROTOCOLSerial232.png"/}}[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_96f8e9b105b4268c.png||alt="Delta DVP PROTOCOLSerial232.png" height="247" width="400"]] |
|
131 |
+Open the tool COMMGR, to communicate with PLC, if know the IP, we can directly click Add to input PLC IP. Or search the PLC IP from LAN. |
92 |
92 |
|
93 |
|
-== {{id name="HASEthernet"/}}**AS Ethernet** == |
|
133 |
+(% style="text-align:center" %) |
|
134 |
+[[image:1696906027584-350.png]] |
94 |
94 |
|
95 |
|
-**1)V-BOX Settings** |
|
136 |
+Double click the HWCONFIG to open the communication settings window. |
96 |
96 |
|
|
138 |
+(% style="text-align:center" %) |
|
139 |
+[[image:台达3.png]] |
|
140 |
+ |
|
141 |
+Expand the Project Tree, open the hardware configuration, double click the PLC icon. |
|
142 |
+ |
|
143 |
+(% style="text-align:center" %) |
|
144 |
+[[image:台达4.png]] |
|
145 |
+ |
|
146 |
+Click COM1 Port Setting, the default Modbus mode is ASCII, need to change to RTU. |
|
147 |
+ |
|
148 |
+(% style="text-align:center" %) |
|
149 |
+[[image:台达5.png]] |
|
150 |
+ |
|
151 |
+ |
|
152 |
+Click Ethernet Port Basic Setting, set the PLC IP and Gateway. Make sure the IP and Gateway is same segment. Then download into PLC. |
|
153 |
+ |
|
154 |
+(% style="text-align:center" %) |
|
155 |
+[[image:台达6.png]] |
|
156 |
+ |
|
157 |
+**Cable Wiring** |
|
158 |
+ |
|
159 |
+(% id="cke_bm_36592S" style="display:none" %) (%%)Pin Definition Diagram |
|
160 |
+ |
|
161 |
+[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_daa33fcae616e61c.png||alt="image-20220831155157-3.png" height="181" width="320"]] |
|
162 |
+ |
|
163 |
+== **AS Series Ethernet** == |
|
164 |
+ |
97 |
97 |
|=**Items**|=**Settings**|=**Note** |
98 |
98 |
|Protocol|DELTA AS300 MODBUS TCP| |
99 |
99 |
|Connection|Ethernet| |
... |
... |
@@ -101,7 +101,7 @@ |
101 |
101 |
|Device No.|1| |
102 |
102 |
|HMI No.|0| |
103 |
103 |
|
104 |
|
-**2)Address List** |
|
172 |
+**Address List** |
105 |
105 |
|
106 |
106 |
|**Type**|**Device registers**|**HMI registers**|**Format**|**Range**|**Note** |
107 |
107 |
|Bit|X|X|X d|0~~63| |
... |
... |
@@ -121,16 +121,31 @@ |
121 |
121 |
|Word|C|C|C h|0~~511| |
122 |
122 |
|Word|E|E|E d|0~~9| |
123 |
123 |
|
124 |
|
-**3)Configure the communication protocol** |
|
192 |
+**PLC Setting** |
125 |
125 |
|
126 |
|
-{{id name="Iimage-20220831160010-4.png"/}}[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_61f1537e99334c67.png||alt="image-20220831160010-4.png" height="708" width="1677"]] |
|
194 |
+1.Open COMMGR ,[Add]→[Driver Name] Driver1→[Connection Setup]→[Type] Ethernet→[Ethernet Card] →[Description] Realtek PCIe GBE Family Controller→[Search] PC and PLC are in |
|
195 |
+the same LAN, click the corresponding PLC IP searched.→[OK] |
127 |
127 |
|
128 |
|
-**4)Cable Wiring** |
|
197 |
+(% style="text-align:center" %) |
|
198 |
+[[image:2.1.png]] |
129 |
129 |
|
130 |
|
-Figure |
|
200 |
+2. Open ISPSoft,[Project]→Double click[HWCONFIG] |
131 |
131 |
|
132 |
|
-{{id name="Iimage-20220831155101-1.png"/}}{{id name="Iimage-20220831160055-5.png"/}}[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_f2c92ecd57ebfbd0.png||alt="image-20220831155101-1.png" height="262" width="118"]] [[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_32ea98dfbc23a591.png||alt="image-20220831160055-5.png" height="198" width="455"]] |
|
202 |
+(% style="text-align:center" %) |
|
203 |
+[[image:台达2.2.png]] |
133 |
133 |
|
134 |
|
-Pin Definition Diagram |
|
205 |
+PLC Default Parameters: |
|
206 |
+[Device]→[Hardware Configuration]→[CPU(AS332T-A)]→[Hardware Configuration]→[General] →[Ethernet Port Basic Setting]: [IP Address]192.168.40.122, [Subnet Mask]255.255.255.0,[Gateway] |
|
207 |
+192.168.40.1→[Download] |
135 |
135 |
|
136 |
|
-{{id name="Iimage-20220831155157-3.png"/}}[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_daa33fcae616e61c.png||alt="image-20220831155157-3.png" height="181" width="320"]] |
|
209 |
+(% style="text-align:center" %) |
|
210 |
+[[image:台达2.3-.png]] |
|
211 |
+ |
|
212 |
+(% style="text-align:center" %) |
|
213 |
+[[image:台达2.4.png]] |
|
214 |
+ |
|
215 |
+**Cable Wiring** |
|
216 |
+ |
|
217 |
+Figure |
|
218 |
+ |
|
219 |
+[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_f2c92ecd57ebfbd0.png||alt="image-20220831155101-1.png" height="262" width="118"]] [[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_32ea98dfbc23a591.png||alt="image-20220831160055-5.png" height="198" width="455"]] |