1 (% class="wikigeneratedid" id="HDVPserial" %)
2 (% id="cke_bm_111267S" style="display:none" %)** **
3
4 == **DVP Serial** ==
5
6 (% class="wikigeneratedid" %)
7 Supoort Series: DELTA DVP EH/ES/SS/EX/EH2/SV/SA/SC/SX
8
9 **V-BOX Settings**
10
11 |=**Items**|=**Settings**|=**Note**
12 |Protocol|DELTA DVP PROTOCOL|
13 |Connection|RS232|
14 |Baud Rate|9600|
15 |Stop Bit|1|
16 |Data Bit|7|
17 |Parity|EVEN|
18 |Device No.|1|
19
20 **Address List**
21
22 |=**Type**|=**Device registers**|=**HMI registers**|=**Format**|=**Range**|=**Note**
23 |Bit|X|X|X d|0~~303237|
24 |Bit|Y|Y|Y d|0~~303237|
25 |Bit|M|M|M d|0~~99999|
26 |Bit|T|T|T d|0~~99999|
27 |Bit|C|C|T d|0~~99999|
28 |Bit|S|S|T d|0~~99999|
29 |Word|D|D|D d|0~~99999|
30 |Word|T|T|T d|0~~99999|
31 |Word|C|C|C d|0~~99999|
32
33 **Wiring Diagram**
34
35 [[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_96f8e9b105b4268c.png||alt="Delta DVP PROTOCOLSerial232.png" height="247" width="400"]]
36
37 == **DVP Ethernet** ==
38
39 Supported Series: Delta DVP ES2/EX2/SS2/SA2/SX2 Controller
40
41 {{info}}
42 ✎Note: It is not suggest DVP SE series controller to use this protocol, please use the MODBUS TCP protocol for SE series.
43 {{/info}}
44
45 **V-BOX Settings**
46
47 |=**Items**|=**Settings**|=**Note**
48 |Protocol|DELTA DVP Modbus TCP|
49 |Connection|Ethernet|
50 |Port No.|502|Must be the same as the PLC setting
51 |PLC station No.|0|Must be the same as the PLC setting
52
53 (% style="text-align:center" %)
54 [[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_514e38138de7059.png||alt="DVPEthernetVNETPortocol.png" height="493" width="729"]]
55
56 **Address List **
57
58 |=**Type**|=**Device registers**|=**VBox registers**|=**Format**|=**Range**|=**Note**
59 |Bit|X|X|X OOO|0~~377|
60 |Bit|Y|Y|Y OOO|0~~377|
61 |Bit|M0|M0|M0DDDD|0~~1535|
62 |Bit|M1|M1|M1DDDD|1536~~4096|
63 |Bit|T|T|TDDD|0~~255|
64 |Bit|C|C|CDDD|0~~255|
65 |Bit|S|S|SDDDD|0~~1023|
66 |Word|D0|D0|D0DDDD|0~~4095|
67 |Word|D1|D1|D1DDDD|4096~~11999|
68 |Word|T|T|TDDD|0~~255|
69 |Word|C|C|CDDD|0~~199|
70 |Double Word|HC|HC|HCDDD|200~~255|
71
72 **PLC Setting:**
73
74 ~1. Create new project in Delta WPL Soft, and click Setting to open the communication settings:
75
76 [[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_c5e594a6b73bdd68.png||alt="DVPEthernetWPLSoft2.png" height="727" width="1366"]]
77
78 2. Set up the communication type and PLC IP:
79
80 [[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_92343d448762200c.png||alt="DVPEthernetSetup.png" height="592" width="346"]]
81
82 3. Click OK and save the settings. Then click Communication on toolbar, then click Transfer Setup to open new window:
83
84 {{id name="IDVPEthernetTransfer.png"/}}[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_a24e318f1e5f0839.png||alt="DVPEthernetTransfer.png" height="726" width="1366"]]
85
86 4. Select Communication Mode as PC => PLC to download or select PC <=PLC to upload:
87
88 [[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_ae301f5422be2294.png||alt="DVPEthernetPLCtoPC.png" height="303" width="308"]]
89
90 5. Click Auto-Search Ethernet Module to find the PLC on the same LAN network:
91
92 {{id name="IDVPEthernetAutoSearch.png"/}}[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_e2c32050bbe425bc.png||alt="DVPEthernetAutoSearch.png" height="723" width="1366"]]
93
94 == **AS Series Serial** ==
95
96 Supported Series: Delta AS200/AS300
97
98 **V-BOX Settings**
99
100 |**Item**|**Settings**|**Note**
101 |Protocol|DELTA AS300 MODBUS RTU|
102 |Connection|RS485|
103 |Baud rate|9600|
104 |Data bit|8|
105 |Parity|NONE|
106 |Stop bit|1|
107 |PLC station No.|1|
108
109 **Address List**
110
111 |=**Type**|=**Device registers**|=**Format**|=**Range**|=**Note**
112 |(% colspan="1" rowspan="9" %)Bit|X|Xdd.dd|0~~63.15|Read only
113 |Y|Ydd.dd|0~~63.15|
114 |D|Dddddd|0~~29999|
115 |M|Mdddd|0~~8191|
116 |SM|SMdddd|0~~4095|
117 |S|Sdddd|0~~2047|
118 |T|Tddd|0~~511|
119 |C|Cddd|0~~511|
120 |HC|HCddd|0~~255|Double Word
121 |(% colspan="1" rowspan="7" %)Word|X|Xdd|0~~63|
122 |Y|Ydd|0~~63|
123 |SR|SRdddd|0~~2047|Special register
124 |D|Dddddd|0~~29999|
125 |T|Tddd|0~~511|
126 |C|Cddd|0~~511|
127 |E|Ed|0~~9|
128
129 **PLC Settings**
130
131 Create project
132
133 (% style="text-align:center" %)
134 [[image:台达1.png]]
135
136 Open the tool COMMGR, to communicate with PLC, if know the IP, we can directly click Add to input PLC IP. Or search the PLC IP from LAN.
137
138 (% style="text-align:center" %)
139 [[image:1696906027584-350.png]]
140
141 Double click the HWCONFIG to open the communication settings window.
142
143 (% style="text-align:center" %)
144 [[image:台达3.png]]
145
146 Expand the Project Tree, open the hardware configuration, double click the PLC icon.
147
148 (% style="text-align:center" %)
149 [[image:台达4.png]]
150
151 Click COM1 Port Setting, the default Modbus mode is ASCII, need to change to RTU.
152
153 (% style="text-align:center" %)
154 [[image:台达5.png]]
155
156
157 Click Ethernet Port Basic Setting, set the PLC IP and Gateway. Make sure the IP and Gateway is same segment. Then download into PLC.
158
159 (% style="text-align:center" %)
160 [[image:台达6.png]]
161
162 **Cable Wiring**
163
164 (% id="cke_bm_36592S" style="display:none" %) (%%)Pin Definition Diagram
165
166 [[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_daa33fcae616e61c.png||alt="image-20220831155157-3.png" height="181" width="320"]]
167
168 == **AS Series Ethernet** ==
169
170 |=**Items**|=**Settings**|=**Note**
171 |Protocol|DELTA AS300 MODBUS TCP|
172 |Connection|Ethernet|
173 |Port No.|502|
174 |Device No.|1|
175 |HMI No.|0|
176
177 **Address List**
178
179 |**Type**|**Device registers**|**HMI registers**|**Format**|**Range**|**Note**
180 |Bit|X|X|X d|0~~63|
181 |Bit|Y|Y|Y d|0~~63|
182 |Bit|D|D|D d|0~~29999|
183 |Bit|M|M|M d|0~~8191|
184 |Bit|SM|SM|SM d|0~~4095|
185 |Bit|S|S|S h|0~~2047|
186 |Bit|T|T|T d|0~~511|
187 |Bit|C|C|C d|0~~511|
188 |Bit|HC|HC|HC d|0~~255|
189 |Word|X|X|X h|0~~63|
190 |Word|Y|Y|Y d|0~~63|
191 |Word|SR|SR|SR d|0~~2047|
192 |Word|D|D|D d|0~~29999|
193 |Word|T|T|T d|0~~511|
194 |Word|C|C|C h|0~~511|
195 |Word|E|E|E d|0~~9|
196
197 **PLC Setting**
198
199 1.Open COMMGR ,[Add]→[Driver Name] Driver1→[Connection Setup]→[Type] Ethernet→[Ethernet Card] →[Description] Realtek PCIe GBE Family Controller→[Search] PC and PLC are in
200 the same LAN, click the corresponding PLC IP searched.→[OK]
201
202 (% style="text-align:center" %)
203 [[image:2.1.png]]
204
205 2. Open ISPSoft,[Project]→Double click[HWCONFIG]
206
207 (% style="text-align:center" %)
208 [[image:台达2.2.png]]
209
210 PLC Default Parameters:
211 [Device]→[Hardware Configuration]→[CPU(AS332T-A)]→[Hardware Configuration]→[General] →[Ethernet Port Basic Setting]: [IP Address]192.168.40.122, [Subnet Mask]255.255.255.0,[Gateway]
212 192.168.40.1→[Download]
213
214 (% style="text-align:center" %)
215 [[image:台达2.3-.png]]
216
217 (% style="text-align:center" %)
218 [[image:台达2.4.png]]
219
220 **Cable Wiring**