Changes for page Siemens

Last modified by Joe on 2024/08/30 14:46

From version 1.1
edited by Leo Wei
on 2023/08/24 14:11
Change comment: Changed document syntax from [XWiki 2.1] to [xwiki/2.1].
To version 15.1
edited by Theodore Xu
on 2023/08/25 15:37
Change comment: There is no comment for this version

Summary

Details

Page properties
Title
... ... @@ -1,0 +1,1 @@
1 +Siemens
Author
... ... @@ -1,1 +1,1 @@
1 -XWiki.admin
1 +XWiki.AiXia
Content
... ... @@ -1,0 +1,292 @@
1 += {{id name="HSiemens"/}}**Siemens ** =
2 +
3 +== **S7-200 Smart Ethernet ** ==
4 +
5 +[[download link>>url:https://ftp.we-con.com.cn/Download/WIKI/V-BOX/Demo/%E9%80%9A%E8%AE%AF%E6%A1%88%E4%BE%8B/Communication%20with%20S7-200%20Smart.zip]]
6 +
7 +**1)PLC software**
8 +
9 +(% style="text-align:center" %)
10 +[[image:西门子软件版本.png]]
11 +
12 +**2)Ethernet Configuration**
13 +
14 +(% style="text-align:center" %)
15 +[[image:以太网通讯配置.png]]
16 +
17 +**3)Connect PC software**
18 +
19 +(% style="text-align:center" %)
20 +[[image:以太网下载.png]]
21 +
22 +**4)Configure of V-net**
23 +
24 +(% style="text-align:center" %)
25 +[[image:西门子200smart 以太网.png]]
26 +
27 +**5)wiring**
28 +
29 +
30 +V-Box : RJ45 Ethernet interface
31 +
32 +PLC : RJ45 Ethernet interface
33 +
34 +(% style="text-align:center" %)
35 +[[image:以太网连接.png]]
36 +
37 +
38 +
39 +== {{id name="HS7-300Ethernet"/}}**S7-300 Ethernet ** ==
40 +
41 +Supported Series: Siemens S7-300 series PLC
42 +
43 +**1)V-BOX setting**
44 +
45 +|**Items**|**Settings**|**Note**
46 +|Protocol|Simens S7-300 Ethernet|
47 +|Connection|Ethernet|
48 +|Port No.|102|
49 +|PLC station No.|2|Need to be same as the PLC setting
50 +
51 +**2)Address List**
52 +
53 +|**Type**|**Device register**|**HMI register**|**Format**|**Range**|**Note**
54 +|(% rowspan="4" %)Bit|I|I|I ddddd.o|0.0~~99999.7|
55 +|Q|Q|Q ddddd.o|0.0~~99999.7|
56 +|M|M|M ddddd.o|0.0~~99999.7|
57 +|DB0.DB~~DB99.DB|DBxDBD|DBxDB nndddd.o|0.0~~99999999.7|(((
58 +nn: block number;
59 +
60 +dddd: address;
61 +)))
62 +|(% rowspan="8" %)Word|I|IW|IW ddddd|0~~99999|
63 +|Q|QW|QW ddddd|0~~99999|
64 +|(% rowspan="3" %)M|MB|MB ddddd|0~~99999|
65 +|MW|MW ddddd|0~~99999|(((
66 +MW0=MB(0~~1)
67 +
68 +MW2=MB(2~~3)
69 +
70 +Address value is a multiple of 2
71 +)))
72 +|MD|MD ddddd|0~~99999|(((
73 +MD0=MB(0~~3)
74 +
75 +MD4=MB(4~~7)
76 +
77 +Address value is a multiple of 4
78 +)))
79 +|(% rowspan="3" %)DB0.DB~~DB99.DB|DBxDBB|DBxDBB nndddd|0~~99999999|(% rowspan="3" %)(((
80 +nn: block number;
81 +
82 +dddd: address
83 +)))
84 +|DBxDBW|DBxDBW nndddd|0~~99999999
85 +|DBxDBD|DBxDBD nndddd|0~~99999999
86 +
87 +**3)Configure the communication protocol**
88 +
89 +{{id name="Iimage-20220824161345-1.png"/}}[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_8e00ed9483ddb629.png||alt="image-20220824161345-1.png" height="1011" width="1920"]]
90 +
91 +**4)Cable Wiring**
92 +
93 +{{id name="Iimage-20220824161450-2.png"/}}[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_ac8ece9a26719fda.png||alt="image-20220824161450-2.png" height="170" width="401"]]
94 +
95 +== {{id name="HS7-1200A0Ethernet"/}}**S7-1200 Ethernet ** ==
96 +
97 +[[download link>>url:https://ftp.we-con.com.cn/Download/WIKI/V-BOX/Demo/%E9%80%9A%E8%AE%AF%E6%A1%88%E4%BE%8B/Communicate%20with%20S7-1200%20via%20Ehernet.zip]]
98 +
99 +== {{id name="HS7-XXXEthernetl"/}}**S7-XXX Ethernet l** ==
100 +
101 +Supported Series: Siemens S7-400, S7-1200 and S7-1500
102 +
103 +**1)V-BOX setting**
104 +
105 +|=**Items**|=**Settings**|=**Note**
106 +|Protocol|Siemens S7-XXX|
107 +|Connection|Ethernet|
108 +|Port No.|102|
109 +|Device No.|Slot (Default 1 for S7-1500/ 2 for S7-1200/ 3 for S7-400)|
110 +|HMI No.|Rack (Default as 0)|
111 +
112 +Slot from TIA Portal is equal to Device No. of V-net
113 +
114 +Rack from TIA Portal is equal to HMI No. of V-net
115 +
116 +{{id name="Iimage-20220824162459-3.png"/}}[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_d78bc267e5fc6394.png||alt="image-20220824162459-3.png" height="503" width="798"]]
117 +
118 +{{id name="Iimage-20220824163305-2.png"/}}[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_c9ae84ef5d418580.png||alt="image-20220824163305-2.png" height="1009" width="1920"]]
119 +
120 +**2)Address List**
121 +
122 +|**Type**|**Device register**|**HMI register**|**Format**|**Range**|**Note**
123 +|(% rowspan="4" %)Bit|I|I|M d.o|(((
124 +d:0~-~-9999
125 +
126 +o:0-7
127 +)))|
128 +|Q|Q|Q d.o|(((
129 +d:0~-~-9999
130 +
131 +o:0-7
132 +)))|
133 +|M|M|M d.o|(((
134 +d:0~-~-9999
135 +
136 +o:0-7
137 +)))|
138 +|DB0.DB-DB99.DB|DBxDB|DBxDBnndddd.o|(((
139 +nn:0-9999,
140 +
141 +dddd:0-9999,
142 +
143 +o:0-7
144 +)))|(((
145 +nn:DB No.
146 +
147 +dddd:address value
148 +
149 +o: digit address
150 +)))
151 +|(% rowspan="8" %)Word|M|MB|MB d|d:0-99999|
152 +|M|MW|MW d|d:0-99999|(((
153 +MW0=MB(0~~1)
154 +
155 +MW2=MB(2~~3)
156 +
157 +Address value is a multiple of 2
158 +)))
159 +|M|MD|MD d|d:0-99999|(((
160 +MD0=MB(0~~3)
161 +
162 +MD4=MB(4~~7)
163 +
164 +Address value is a multiple of 4
165 +)))
166 +|I|IW|IW d|d:0-99999|
167 +|Q|QW|QW d|d:0-99999|
168 +|DB0.DB-DB99.DB|DBxDBB|DBxDBBnndddd|(((
169 +nn:0-9999
170 +
171 +dddd:0-9999
172 +)))|(((
173 +nn:DB No.
174 +
175 +dddd:address value
176 +)))
177 +|DB0.DB-DB99.DB|DBxDBW|DBxDBWnndddd|(((
178 +nn:0-9999
179 +
180 +dddd:0-9999
181 +)))|(((
182 +nn:DB No.
183 +
184 +dddd:address value
185 +
186 +Address value is a multiple of 2
187 +)))
188 +|DB0.DB-DB99.DB|DBxDBD|DBxDBDnndddd|(((
189 +nn:0-9999
190 +
191 +dddd:0-9999
192 +)))|(((
193 +nn:DB No.
194 +
195 +dddd:address value
196 +
197 +Address value is a multiple of 4
198 +)))
199 +
200 +**3)Configure the communication protocol**
201 +
202 +{{id name="Iimage-20220824163448-3.png"/}}[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_9e740a8bf83ea3bf.png||alt="image-20220824163448-3.png" height="557" width="974"]]
203 +
204 +**✎Note:**
205 +
206 +* The S7-1200 supports simultaneous connection of three devices, so the driver supports simultaneous access to PLC by three V-BOX.
207 +* V-BOX access PLC, use S7 protocol, access PLC TSAP 02.01 (s7-1200 PROFINET interface only supports three connections, the default support), detailed reference to the system manual of S7-1200.
208 +
209 +**4)Cable Wiring**
210 +
211 +{{id name="Iimage-20220824162342-2.png"/}}[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_ac8ece9a26719fda.png||alt="image-20220824162342-2.png" height="170" width="401"]]
212 +
213 +== {{id name="HLOGOEthernet"/}}**LOGO Ethernet ** ==
214 +
215 +Supported Series: Siemens Logo 0BA0, 0BA1 series
216 +
217 +**V-BOX Settings**
218 +
219 +|**Items**|**Settings**|**Note**
220 +|Protocol|Siemens LOGO|
221 +|Connection|Ethernet|
222 +|Port No.|102|
223 +|PLC station No.|2|
224 +
225 +**Address List**
226 +
227 +|**Number**|**Address Type**|**Data Type**|**Range**|**DB Address**|**PLC Address**
228 +|1|RTC|Word|1-7|DB1.DBX984.0|0x001ec0
229 +|2|VB|Byte|0-1469|DB1.DBX0.0|0x000000
230 +|3|VD|Double Word|0-1466|DB1.DBX0.0|0x000000
231 +|4|VW|Word|0-1468|DB1.DBX0.0|0x000000
232 +|5|NAQ|Word|1-32|DB1.DBX1406.0|0x002bf0
233 +|6|NAI|Word|1-64|DB1.DBX1262.0|0x002770
234 +|7|AM|Word|1-64|DB1.DBX1118.0|0x0022f0
235 +|8|AQ|Word|1-16|DB1.DBX1072.0|0x002180
236 +|9|AI|Word|1-16|DB1.DBX1032.0|0x002040
237 +|10|I|Bit|1-64|DB1.DBX1024.0|0x002000
238 +|11|Q|Bit|1-64|DB1.DBX1064.0|0x002140
239 +|12|M|Bit|1-112|DB1.DBX1104.0|0x002280
240 +|13|NI|Bit|1-128|DB1.DBX1246.0|0x0026f0
241 +|14|NQ|Bit|1-128|DB1.DBX1390.0|0x002b70
242 +|15|V|Bit|0-14697|DB1.DBX0.0|0x000000
243 +
244 +**PLC Settings in LOGO Software:**
245 +
246 +Click [Tools]~-~-[Ethernet Connections],shown as below.
247 +
248 +{{id name="IPIStudio.125C.PLCprotocols.WebHome4012.PLCProtocol_html_8b9d2322edf89519.png"/}}[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_d13df637bfedcc52.png||alt="12.PLC Protocol_html_8b9d2322edf89519.png" height="641" width="423"]]
249 +
250 +Set Ethernet connection parameter. IP, Subnet Mask, shown as below.
251 +
252 +{{id name="IPIStudio.125C.PLCprotocols.WebHome40image-20221228142937-4.png"/}}[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_316247e0130c4c55.png||alt="image-20221228142937-4.png" height="484" width="366"]]
253 +
254 +**TSAP set**:The value set by local TSAP is the remote TSAP set in HMI. PLC's remote TSAP is the opposite,shown as below.
255 +
256 +{{id name="IPIStudio.125C.PLCprotocols.WebHome40image-20221228143047-5.png"/}}[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_facc6ee1af05162f.png||alt="image-20221228143047-5.png" height="626" width="1088"]]
257 +
258 + **Download Project**: Click "Address book" to add the IP address to be downloaded (fi."Detect" to check whether the IP address can be detected. Then click “ok”, and the system will prompt that PLC will be "STOP" mode. Click “YES” to start download.
259 +
260 +{{id name="IPIStudio.125C.PLCprotocols.WebHome40image-20221228143246-6.png"/}}[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_d43d2b7b2599ee64.png||alt="image-20221228143246-6.png" height="698" width="688"]]
261 +
262 +**V-BOX Communication Settings**
263 +
264 +Set PLC IP in [IP Address] settings;
265 +
266 +{{id name="ILldwDGntf4.png"/}}[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_ab570912d299c09.png||alt="LldwDGntf4.png" height="530" width="899"]]
267 +
268 +Enable V-BOX Ethernet in [Network];
269 +
270 +{{id name="IWgvjfWbQif.png"/}}[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_637860db3ca1ca1b.png||alt="WgvjfWbQif.png" height="654" width="1195"]]
271 +
272 +TSAP setting
273 +
274 +* The initialization script needs to set the source TSAP address and the target TSAP address, otherwise the communication will not be successful.
275 +
276 +**function** **init**.main()
277 + addr_setword("@W_0#HSW1200",8192) //~-~- Set the source TSAP address//
278 + addr_setword("@W_0#HSW1201",4096) //~-~- Set the destination TSAP address//
279 + **end**
280 +
281 +Note: The name of the test script is init, 8192 and 4096 are the data used for the test, there is no HSW address in the register option, but you can directly set the value of the corresponding address through the code.
282 +
283 +**✎Note:**
284 +
285 +* **Communication port configuration: **
286 +** Continuous length needs to be set to 0.
287 +** Integration interval needs to be set to 1. (no change may result in data errors)
288 +** Set Port and Device Station NO.
289 +** Other set as defaulted.
290 +* **Notes on the use of registers:**
291 +** Register VD: Use only registers that are multiples of 4, such as 0, 4, 8, etc.
292 +** Register VW: Use only registers thay are multiples of 2, such as 0, 2, 4 etc. (Using an odd-length register may result in data errors, such as 2 3 4 )
xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_316247e0130c4c55.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.admin
Size
... ... @@ -1,0 +1,1 @@
1 +14.8 KB
Content
xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_637860db3ca1ca1b.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.admin
Size
... ... @@ -1,0 +1,1 @@
1 +36.3 KB
Content
xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_8e00ed9483ddb629.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.admin
Size
... ... @@ -1,0 +1,1 @@
1 +126.0 KB
Content
xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_9e740a8bf83ea3bf.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.admin
Size
... ... @@ -1,0 +1,1 @@
1 +42.8 KB
Content
xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_ab570912d299c09.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.admin
Size
... ... @@ -1,0 +1,1 @@
1 +24.3 KB
Content
xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_ac8ece9a26719fda.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.admin
Size
... ... @@ -1,0 +1,1 @@
1 +107.1 KB
Content
xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_c9ae84ef5d418580.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.admin
Size
... ... @@ -1,0 +1,1 @@
1 +127.5 KB
Content
xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_d13df637bfedcc52.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.admin
Size
... ... @@ -1,0 +1,1 @@
1 +36.0 KB
Content
xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_d43d2b7b2599ee64.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.admin
Size
... ... @@ -1,0 +1,1 @@
1 +40.0 KB
Content
xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_d78bc267e5fc6394.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.admin
Size
... ... @@ -1,0 +1,1 @@
1 +32.6 KB
Content
xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_facc6ee1af05162f.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.admin
Size
... ... @@ -1,0 +1,1 @@
1 +52.3 KB
Content
以太网下载.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.AiXia
Size
... ... @@ -1,0 +1,1 @@
1 +102.2 KB
Content
以太网连接.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.AiXia
Size
... ... @@ -1,0 +1,1 @@
1 +257.6 KB
Content
以太网通讯配置.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.AiXia
Size
... ... @@ -1,0 +1,1 @@
1 +132.2 KB
Content
西门子200smart 以太网.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.AiXia
Size
... ... @@ -1,0 +1,1 @@
1 +61.6 KB
Content
西门子软件版本.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.AiXia
Size
... ... @@ -1,0 +1,1 @@
1 +146.3 KB
Content