From version 14.1
edited by Theodore Xu
on 2023/08/25 15:10
on 2023/08/25 15:10
Change comment:
There is no comment for this version
To version 48.1
edited by Theodore Xu
on 2024/02/27 19:59
on 2024/02/27 19:59
Change comment:
There is no comment for this version
Summary
-
Page properties (1 modified, 0 added, 0 removed)
-
Attachments (0 modified, 14 added, 0 removed)
- 1697099618537-157.png
- 485接线.png
- 485通讯配置.png
- V-NET_Client logo.png
- V-NET_Client logo8.png
- xwiki_PIStudio_12.PLC+protocols_WebHome_664a826cd356c830.png
- xwiki_PIStudio_12.PLC+protocols_WebHome_78026942a88f0fdb.png
- xwiki_PIStudio_12.PLC+protocols_WebHome_872ec32d12b55aa.png
- xwiki_PIStudio_12.PLC+protocols_WebHome_8ee8d3ac3637bfc4.png
- xwiki_PIStudio_12.PLC+protocols_WebHome_ac8ece9a26719fda.png
- 以太网 PC和PLC连接.png
- 以太网连接.png
- 西门子1200协议参数.png
- 西门子200串口.png
Details
- Page properties
-
- Content
-
... ... @@ -1,34 +1,133 @@ 1 -= {{id name="HSiemens"/}}**Siemens** =1 +== **S7-200 Smart Serial** == 2 2 3 - ==**S7-200SmartEthernet**==3 +**V-BOX setting** 4 4 5 -[[download link>>url:https://ftp.we-con.com.cn/Download/WIKI/V-BOX/Demo/%E9%80%9A%E8%AE%AF%E6%A1%88%E4%BE%8B/Communication%20with%20S7-200%20Smart.zip]] 5 +(% style="width:1323.87px" %) 6 +|**Items**|**Settings**|**Note** 7 +|Protocol|(% style="width:783px" %)Siemens S7-200 CPU22x/Smart PPI| 8 +|Connection|(% style="width:783px" %)RS485| 9 +|Baud rate|(% style="width:783px" %)9600| 10 +|Data bit|(% style="width:783px" %)8| 11 +|Parity|(% style="width:783px" %)EVEN| 12 +|Stop bit|(% style="width:783px" %)1| 13 +|PLC station No.|(% style="width:783px" %)2| 6 6 7 -**1)PLC software** 15 +(% style="text-align:center" %) 16 +[[image:西门子200串口.png]] 8 8 18 +**Address List ** 19 + 20 +|**Type**|**Device register**|**Format**|**Range**|**Note** 21 +|(% rowspan="9" %)Bit|I|I ddddd.o|0.0~~99999.7| 22 +|Q|Q ddddd.o|0.0~~99999.7| 23 +|V|VWbit ddddd.o|0.0~~99999.7| 24 +|V|V ddddd.o|0.0~~99999.7| 25 +|M|M ddddd.o|0.0~~99999.7| 26 +|SM|ddddd.o|0.0~~99999.7| 27 +|S|ddddd.o|0.0~~99999.7|Read only 28 +|T|ddddd|0~~99999|Timer state, read only 29 +|C|ddddd|0~~99999|Counter state, read only 30 +|(% rowspan="12" %)Word|I|IW ddddd|0~~99999| 31 +|Q|QW ddddd|0~~99999| 32 +|AI|AIW ddddd|0~~99999| 33 +|AQ|VB ddddd|0~~99999| 34 +|V|VW ddddd|0~~99998|((( 35 +VW0=VB (0~~1) 36 + 37 +VW2=VB (2~~3) 38 + 39 +Address value is a multiple of 2 40 +))) 41 +|V|VD ddddd|0~~99998|((( 42 +VD0=VB (0~~3) 43 + 44 +VD2=VB (4~~7) 45 + 46 +Address value is a multiple of 4 47 +))) 48 +|M|MB ddddd|0~~99999| 49 +|M|MW ddddd|0~~99999|((( 50 +MW0=MB(0~~1) 51 + 52 +MW2=MB(2~~3) 53 + 54 +Address value is a multiple of 2 55 +))) 56 +|M|MD ddddd|0~~99999|((( 57 +MD0=MB(0~~3) 58 + 59 +MD4=MB(4~~7) 60 + 61 +Address value is a multiple of 4 62 +))) 63 +|T|TW ddddd|0~~99999|Value of timer 64 +|C|CW ddddd|0~~99999|Value of counter 65 +|W|SW ddddd|0~~99999| 66 + 67 +**PLC setting** 68 + 9 9 (% style="text-align:center" %) 10 10 [[image:西门子软件版本.png]] 11 11 12 -**2)Ethernet Configuration** 72 +(% style="text-align:center" %) 73 +[[image:485通讯配置.png]] 13 13 75 +**Connect and Download** 76 + 14 14 (% style="text-align:center" %) 78 +[[image:以太网 PC和PLC连接.png]] 79 + 80 +(% style="text-align:center" %) 81 +[[image:以太网下载.png]] 82 + 83 +**Cable Wiring** 84 + 85 +(% style="text-align:center" %) 86 +[[image:485接线.png]] 87 + 88 +== **S7-200 Smart Ethernet ** == 89 + 90 +**V-BOX setting** 91 + 92 +|**Items**|**Settings** 93 +|Protocol|Siemens S7-200 Smart(Ethernet) 94 +|Connection|Ethernet 95 +|Port No.|102 96 +|PLC station No.|2 97 + 98 +(% style="text-align:center" %) 99 +[[image:西门子200smart 以太网.png]] 100 + 101 +**PLC setting** 102 + 103 +(% style="text-align:center" %) 104 +[[image:西门子软件版本.png]] 105 + 106 +(% style="text-align:center" %) 15 15 [[image:以太网通讯配置.png]] 16 16 17 -** 3)ConnectPCsoftware**109 +**Connect and Download** 18 18 19 19 (% style="text-align:center" %) 112 +[[image:以太网 PC和PLC连接.png]] 113 + 114 +(% style="text-align:center" %) 20 20 [[image:以太网下载.png]] 21 21 22 - 4)**Configureof V-net**117 +**Cable Wiring** 23 23 119 +V-Box : RJ45 Ethernet interface 120 + 121 +PLC : RJ45 Ethernet interface 122 + 24 24 (% style="text-align:center" %) 25 -[[image: 西门子200smart以太网.png]]124 +[[image:以太网连接.png]] 26 26 27 -== {{id name="HS7-300Ethernet"/}}**S7-300 Ethernet ** ==126 +== **S7-300 Ethernet ** == 28 28 29 29 Supported Series: Siemens S7-300 series PLC 30 30 31 -** 1)V-BOX setting**130 +**V-BOX setting** 32 32 33 33 |**Items**|**Settings**|**Note** 34 34 |Protocol|Simens S7-300 Ethernet| ... ... @@ -36,21 +36,21 @@ 36 36 |Port No.|102| 37 37 |PLC station No.|2|Need to be same as the PLC setting 38 38 39 -** 2)Address List**138 +**Address List** 40 40 41 -|**Type**|**Device register**|** HMI register**|**Format**|**Range**|**Note**42 -|(% rowspan="4" %)Bit|I|I |Iddddd.o|0.0~~99999.7|43 -|Q|Q |Qddddd.o|0.0~~99999.7|44 -|M|M |Mddddd.o|0.0~~99999.7|45 -|DB0.DB~~DB99.DB|DBxDB D|DBxDBnndddd.o|0.0~~99999999.7|(((140 +|**Type**|**Device register**|**Format**|**Range**|**Note** 141 +|(% rowspan="4" %)Bit|I|I ddddd.o|0.0~~99999.7| 142 +|Q|Q ddddd.o|0.0~~99999.7| 143 +|M|M ddddd.o|0.0~~99999.7| 144 +|DB0.DB~~DB99.DB|DBxDB nndddd.o|0.0~~99999999.7|((( 46 46 nn: block number; 47 47 48 48 dddd: address; 49 49 ))) 50 -|(% rowspan="8" %)Word|I|IW |IWddddd|0~~99999|51 -|Q|QW |QWddddd|0~~99999|52 -|(% rowspan="3" %)M|MB |MBddddd|0~~99999|53 -|MW |MWddddd|0~~99999|(((149 +|(% rowspan="8" %)Word|I|IW ddddd|0~~99999| 150 +|Q|QW ddddd|0~~99999| 151 +|(% rowspan="3" %)M|MB ddddd|0~~99999| 152 +|MW ddddd|0~~99999|((( 54 54 MW0=MB(0~~1) 55 55 56 56 MW2=MB(2~~3) ... ... @@ -57,7 +57,7 @@ 57 57 58 58 Address value is a multiple of 2 59 59 ))) 60 -|MD |MDddddd|0~~99999|(((159 +|MD ddddd|0~~99999|((( 61 61 MD0=MB(0~~3) 62 62 63 63 MD4=MB(4~~7) ... ... @@ -64,49 +64,39 @@ 64 64 65 65 Address value is a multiple of 4 66 66 ))) 67 -|(% rowspan="3" %)DB0.DB~~DB99.DB|DBxDBB |DBxDBBnndddd|0~~99999999|(% rowspan="3" %)(((166 +|(% rowspan="3" %)DB0.DB~~DB99.DB|DBxDBB nndddd|0~~99999999|(% rowspan="3" %)((( 68 68 nn: block number; 69 69 70 70 dddd: address 71 71 ))) 72 -|DBxDBW |DBxDBWnndddd|0~~9999999973 -|DBxDBD |DBxDBDnndddd|0~~99999999171 +|DBxDBW nndddd|0~~99999999 172 +|DBxDBD nndddd|0~~99999999 74 74 75 -** 3)Configure the communication protocol**174 +**Configure the communication protocol** 76 76 77 - {{id name="Iimage-20220824161345-1.png"/}}[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_8e00ed9483ddb629.png||alt="image-20220824161345-1.png" height="1011" width="1920"]]176 +[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_8e00ed9483ddb629.png||alt="image-20220824161345-1.png" height="1011" width="1920"]] 78 78 79 -** 4)Cable Wiring**178 +**Cable Wiring** 80 80 81 - {{id name="Iimage-20220824161450-2.png"/}}[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_ac8ece9a26719fda.png||alt="image-20220824161450-2.png" height="170" width="401"]]180 +[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_ac8ece9a26719fda.png||alt="image-20220824161450-2.png" height="170" width="401"]] 82 82 83 -== {{id name="HS7-1200A0Ethernet"/}}**S7-1200 Ethernet ** ==182 +== **S7-1200 Ethernet ** == 84 84 85 85 [[download link>>url:https://ftp.we-con.com.cn/Download/WIKI/V-BOX/Demo/%E9%80%9A%E8%AE%AF%E6%A1%88%E4%BE%8B/Communicate%20with%20S7-1200%20via%20Ehernet.zip]] 86 86 87 - == {{id name="HS7-XXXEthernetl"/}}**S7-XXXEthernetl**==186 +**V-BOX Setting** 88 88 89 -Supported Series: Siemens S7-400, S7-1200 and S7-1500 90 - 91 -**1)V-BOX setting** 92 - 93 -|=**Items**|=**Settings**|=**Note** 94 -|Protocol|Siemens S7-XXX| 188 +|**Items**|**Settings**|**Note** 189 +|Protocol|Siemens S7-1200| 95 95 |Connection|Ethernet| 96 96 |Port No.|102| 97 -|Device No.|Slot (Default 1 for S7-1500/ 2 for S7-1200/ 3 for S7-400)| 98 -|HMI No.|Rack (Default as 0)| 192 +|PLC station No.|2| 99 99 100 -Slot from TIA Portal is equal to Device No. of V-net 194 +(% style="text-align:center" %) 195 +[[image:西门子1200协议参数.png]] 101 101 102 - Rack from TIAPortalisequalto HMI No. of V-net197 +**Address List** 103 103 104 -{{id name="Iimage-20220824162459-3.png"/}}[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_d78bc267e5fc6394.png||alt="image-20220824162459-3.png" height="503" width="798"]] 105 - 106 -{{id name="Iimage-20220824163305-2.png"/}}[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_c9ae84ef5d418580.png||alt="image-20220824163305-2.png" height="1009" width="1920"]] 107 - 108 -**2)Address List** 109 - 110 110 |**Type**|**Device register**|**HMI register**|**Format**|**Range**|**Note** 111 111 |(% rowspan="4" %)Bit|I|I|M d.o|((( 112 112 d:0~-~-9999 ... ... @@ -185,18 +185,176 @@ 185 185 Address value is a multiple of 4 186 186 ))) 187 187 188 -**3)Configure the communication protocol** 277 +{{info}} 278 +✎Note: 189 189 190 -{{id name="Iimage-20220824163448-3.png"/}}[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_9e740a8bf83ea3bf.png||alt="image-20220824163448-3.png" height="557" width="974"]] 280 +* The S7-1200 supports simultaneous connection of three devices. 281 +* V-BOX access PLC, use S7 protocol, access PLC TSAP 02.01 (S7-1200 PROFINET interface only supports three connections, the default support), detailed reference to the system manual of S7-1200. 282 +* S7-1200 String type, the default first two bytes are used to store the maximum character and valid characters, so the text data will be shifted back one word address. When interacting with the data, what way this address plc is displayed with is unknown. And because of an extra word of data causes us to display the wrong. The solution is if we use String, then the actual data address we want to operate on is actually shifted back two bytes, so as long as the address on the project is shifted back 2 bits to correspond with the actual data address. 283 +* V-BOX operation character length needs to be set to 2 times the length of the Siemens character for proper display 284 +{{/info}} 191 191 286 +**PLC Settings** 287 + 288 +Add BD 289 + 290 +* Please uncheck [Symbolic access only] option; 291 + 292 +(% style="text-align:center" %) 293 +[[image:xwiki_PIStudio_12.PLC+protocols_WebHome_872ec32d12b55aa.png]] 294 + 295 +Address settings, using BD2 as example. 296 + 297 +* DB×DBB2xxxx, DB×DBW2xxxx, DB×DBD2xxxx for accessing data of DB2 in B1. 298 +* 2 represent DB block number 299 +* xxxx represent address 300 + 301 +**Such as:** 302 + 303 +* DBxDBB20000 = DB2.DBB0 304 +* DBxDBW20004 = DB2.DBW4 305 + 306 +(% style="text-align:center" %) 307 +[[image:xwiki_PIStudio_12.PLC+protocols_WebHome_8ee8d3ac3637bfc4.png]] 308 + 309 +**How to connect with S7-1200 Firmware V4.0** 310 + 311 +PLC configuration 312 + 313 +* Double click [device configuration] in Siemens via software 314 +* Double click [protection] to enter protection configuration screen 315 + 316 +(% style="text-align:center" %) 317 +[[image:xwiki_PIStudio_12.PLC+protocols_WebHome_664a826cd356c830.png]] 318 + 319 +* Check [Permit access with PUT / GET communication from remote partner (PLC, HMI, OPC, ...)] 320 + 321 +(% style="text-align:center" %) 322 +[[image:xwiki_PIStudio_12.PLC+protocols_WebHome_78026942a88f0fdb.png]] 323 + 324 +DB settings 325 + 326 +* Right click [DB], select [properties] 327 +* Uncheck [optimized block access] 328 + 329 +**Cable Wiring** 330 + 331 +(% style="text-align:center" %) 332 +[[image:xwiki_PIStudio_12.PLC+protocols_WebHome_ac8ece9a26719fda.png]] 333 + 334 +== **S7-XXX Ethernet** == 335 + 336 +Supported Series: Siemens S7-400, S7-1200 and S7-1500 337 + 338 +**V-BOX setting** 339 + 340 +|=**Items**|=**Settings**|=**Note** 341 +|Protocol|Siemens S7-XXX| 342 +|Connection|Ethernet| 343 +|Port No.|102| 344 +|Device No.|Slot (Default 1 for S7-1500/ 2 for S7-1200/ 3 for S7-400)| 345 +|HMI No.|Rack (Default as 0)| 346 + 347 +Slot from TIA Portal is equal to Device No. of V-net 348 + 349 +Rack from TIA Portal is equal to HMI No. of V-net 350 + 351 +[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_d78bc267e5fc6394.png||alt="image-20220824162459-3.png" height="503" width="798"]] 352 + 353 +[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_c9ae84ef5d418580.png||alt="image-20220824163305-2.png" height="1009" width="1920"]] 354 + 355 +**Address List** 356 + 357 +|**Type**|**Device register**|**Format**|**Range**|**Note** 358 +|(% rowspan="4" %)Bit|I|M d.o|((( 359 +d:0~-~-9999 360 + 361 +o:0-7 362 +)))| 363 +|Q|Q d.o|((( 364 +d:0~-~-9999 365 + 366 +o:0-7 367 +)))| 368 +|M|M d.o|((( 369 +d:0~-~-9999 370 + 371 +o:0-7 372 +)))| 373 +|DB0.DB-DB99.DB|DBxDBnndddd.o|((( 374 +nn:0-9999, 375 + 376 +dddd:0-9999, 377 + 378 +o:0-7 379 +)))|((( 380 +nn:DB No. 381 + 382 +dddd:address value 383 + 384 +o: digit address 385 +))) 386 +|(% rowspan="8" %)Word|M|MB d|d:0-99999| 387 +|M|MW d|d:0-99999|((( 388 +MW0=MB(0~~1) 389 + 390 +MW2=MB(2~~3) 391 + 392 +Address value is a multiple of 2 393 +))) 394 +|M|MD d|d:0-99999|((( 395 +MD0=MB(0~~3) 396 + 397 +MD4=MB(4~~7) 398 + 399 +Address value is a multiple of 4 400 +))) 401 +|I|IW d|d:0-99999| 402 +|Q|QW d|d:0-99999| 403 +|DB0.DB-DB99.DB|DBxDBBnndddd|((( 404 +nn:0-9999 405 + 406 +dddd:0-9999 407 +)))|((( 408 +nn:DB No. 409 + 410 +dddd:address value 411 +))) 412 +|DB0.DB-DB99.DB|DBxDBWnndddd|((( 413 +nn:0-9999 414 + 415 +dddd:0-9999 416 +)))|((( 417 +nn:DB No. 418 + 419 +dddd:address value 420 + 421 +Address value is a multiple of 2 422 +))) 423 +|DB0.DB-DB99.DB|DBxDBDnndddd|((( 424 +nn:0-9999 425 + 426 +dddd:0-9999 427 +)))|((( 428 +nn:DB No. 429 + 430 +dddd:address value 431 + 432 +Address value is a multiple of 4 433 +))) 434 + 435 +**Configure the communication protocol** 436 + 437 +[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_9e740a8bf83ea3bf.png||alt="image-20220824163448-3.png" height="557" width="974"]] 438 + 192 192 **✎Note:** 193 193 194 194 * The S7-1200 supports simultaneous connection of three devices, so the driver supports simultaneous access to PLC by three V-BOX. 195 195 * V-BOX access PLC, use S7 protocol, access PLC TSAP 02.01 (s7-1200 PROFINET interface only supports three connections, the default support), detailed reference to the system manual of S7-1200. 196 196 197 -** 4)Cable Wiring**444 +**Cable Wiring** 198 198 199 - {{id name="Iimage-20220824162342-2.png"/}}[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_ac8ece9a26719fda.png||alt="image-20220824162342-2.png" height="170" width="401"]]446 +[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_ac8ece9a26719fda.png||alt="image-20220824162342-2.png" height="170" width="401"]] 200 200 201 201 == {{id name="HLOGOEthernet"/}}**LOGO Ethernet ** == 202 202 ... ... @@ -233,30 +233,27 @@ 233 233 234 234 Click [Tools]~-~-[Ethernet Connections],shown as below. 235 235 236 - {{id name="IPIStudio.125C.PLCprotocols.WebHome4012.PLCProtocol_html_8b9d2322edf89519.png"/}}[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_d13df637bfedcc52.png||alt="12.PLC Protocol_html_8b9d2322edf89519.png" height="641" width="423"]]483 +[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_d13df637bfedcc52.png||alt="12.PLC Protocol_html_8b9d2322edf89519.png" height="641" width="423"]] 237 237 238 238 Set Ethernet connection parameter. IP, Subnet Mask, shown as below. 239 239 240 - {{id name="IPIStudio.125C.PLCprotocols.WebHome40image-20221228142937-4.png"/}}[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_316247e0130c4c55.png||alt="image-20221228142937-4.png" height="484" width="366"]]487 +[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_316247e0130c4c55.png||alt="image-20221228142937-4.png" height="484" width="366"]] 241 241 242 242 **TSAP set**:The value set by local TSAP is the remote TSAP set in HMI. PLC's remote TSAP is the opposite,shown as below. 243 243 244 - {{id name="IPIStudio.125C.PLCprotocols.WebHome40image-20221228143047-5.png"/}}[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_facc6ee1af05162f.png||alt="image-20221228143047-5.png" height="626" width="1088"]]491 +[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_facc6ee1af05162f.png||alt="image-20221228143047-5.png" height="626" width="1088"]] 245 245 246 246 **Download Project**: Click "Address book" to add the IP address to be downloaded (fi."Detect" to check whether the IP address can be detected. Then click “ok”, and the system will prompt that PLC will be "STOP" mode. Click “YES” to start download. 247 247 248 - {{id name="IPIStudio.125C.PLCprotocols.WebHome40image-20221228143246-6.png"/}}[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_d43d2b7b2599ee64.png||alt="image-20221228143246-6.png" height="698" width="688"]]495 +[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_d43d2b7b2599ee64.png||alt="image-20221228143246-6.png" height="698" width="688"]] 249 249 250 250 **V-BOX Communication Settings** 251 251 252 252 Set PLC IP in [IP Address] settings; 253 253 254 -{{id name="ILldwDGntf4.png"/}}[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_ab570912d299c09.png||alt="LldwDGntf4.png" height="530" width="899"]] 501 +(% style="text-align:center" %) 502 +[[image:V-NET_Client logo.png]] 255 255 256 -Enable V-BOX Ethernet in [Network]; 257 - 258 -{{id name="IWgvjfWbQif.png"/}}[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_637860db3ca1ca1b.png||alt="WgvjfWbQif.png" height="654" width="1195"]] 259 - 260 260 TSAP setting 261 261 262 262 * The initialization script needs to set the source TSAP address and the target TSAP address, otherwise the communication will not be successful. ... ... @@ -264,7 +264,7 @@ 264 264 **function** **init**.main() 265 265 addr_setword("@W_0#HSW1200",8192) //~-~- Set the source TSAP address// 266 266 addr_setword("@W_0#HSW1201",4096) //~-~- Set the destination TSAP address// 267 - 511 +**end** 268 268 269 269 Note: The name of the test script is init, 8192 and 4096 are the data used for the test, there is no HSW address in the register option, but you can directly set the value of the corresponding address through the code. 270 270
- 1697099618537-157.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.AiXia - Size
-
... ... @@ -1,0 +1,1 @@ 1 +36.4 KB - Content
- 485接线.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.AiXia - Size
-
... ... @@ -1,0 +1,1 @@ 1 +242.2 KB - Content
- 485通讯配置.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.AiXia - Size
-
... ... @@ -1,0 +1,1 @@ 1 +154.4 KB - Content
- V-NET_Client logo.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.AiXia - Size
-
... ... @@ -1,0 +1,1 @@ 1 +22.4 KB - Content
- V-NET_Client logo8.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.AiXia - Size
-
... ... @@ -1,0 +1,1 @@ 1 +22.4 KB - Content
- xwiki_PIStudio_12.PLC+protocols_WebHome_664a826cd356c830.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.AiXia - Size
-
... ... @@ -1,0 +1,1 @@ 1 +82.1 KB - Content
- xwiki_PIStudio_12.PLC+protocols_WebHome_78026942a88f0fdb.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.AiXia - Size
-
... ... @@ -1,0 +1,1 @@ 1 +39.3 KB - Content
- xwiki_PIStudio_12.PLC+protocols_WebHome_872ec32d12b55aa.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.AiXia - Size
-
... ... @@ -1,0 +1,1 @@ 1 +133.4 KB - Content
- xwiki_PIStudio_12.PLC+protocols_WebHome_8ee8d3ac3637bfc4.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.AiXia - Size
-
... ... @@ -1,0 +1,1 @@ 1 +96.9 KB - Content
- xwiki_PIStudio_12.PLC+protocols_WebHome_ac8ece9a26719fda.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.AiXia - Size
-
... ... @@ -1,0 +1,1 @@ 1 +107.1 KB - Content
- 以太网 PC和PLC连接.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.AiXia - Size
-
... ... @@ -1,0 +1,1 @@ 1 +131.3 KB - Content
- 以太网连接.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.AiXia - Size
-
... ... @@ -1,0 +1,1 @@ 1 +257.6 KB - Content
- 西门子1200协议参数.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.AiXia - Size
-
... ... @@ -1,0 +1,1 @@ 1 +64.6 KB - Content
- 西门子200串口.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.AiXia - Size
-
... ... @@ -1,0 +1,1 @@ 1 +64.5 KB - Content