Changes for page Siemens

Last modified by Joe on 2024/08/30 14:46

From version 15.1
edited by Theodore Xu
on 2023/08/25 15:37
Change comment: There is no comment for this version
To version 45.1
edited by Theodore Xu
on 2023/10/12 16:37
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -1,32 +1,121 @@
1 -= {{id name="HSiemens"/}}**Siemens ** =
1 +== **S7-200 Smart Serial** ==
2 2  
3 -== **S7-200 Smart Ethernet ** ==
3 +**V-BOX setting**
4 4  
5 -[[download link>>url:https://ftp.we-con.com.cn/Download/WIKI/V-BOX/Demo/%E9%80%9A%E8%AE%AF%E6%A1%88%E4%BE%8B/Communication%20with%20S7-200%20Smart.zip]]
5 +(% style="width:1323.87px" %)
6 +|**Items**|**Settings**|**Note**
7 +|Protocol|(% style="width:783px" %)Siemens S7-200 CPU22x/Smart PPI|
8 +|Connection|(% style="width:783px" %)RS485|
9 +|Baud rate|(% style="width:783px" %)9600|
10 +|Data bit|(% style="width:783px" %)8|
11 +|Parity|(% style="width:783px" %)EVEN|
12 +|Stop bit|(% style="width:783px" %)1|
13 +|PLC station No.|(% style="width:783px" %)2|
6 6  
7 -**1)PLC software**
15 +(% style="text-align:center" %)
16 +[[image:西门子200串口.png]]
8 8  
18 +**Address List **
19 +
20 +|**Type**|**Device register**|**Format**|**Range**|**Note**
21 +|(% rowspan="9" %)Bit|I|I ddddd.o|0.0~~99999.7|
22 +|Q|Q ddddd.o|0.0~~99999.7|
23 +|V|VWbit ddddd.o|0.0~~99999.7|
24 +|V|V ddddd.o|0.0~~99999.7|
25 +|M|M ddddd.o|0.0~~99999.7|
26 +|SM|ddddd.o|0.0~~99999.7|
27 +|S|ddddd.o|0.0~~99999.7|Read only
28 +|T|ddddd|0~~99999|Timer state, read only
29 +|C|ddddd|0~~99999|Counter state, read only
30 +|(% rowspan="12" %)Word|I|IW ddddd|0~~99999|
31 +|Q|QW ddddd|0~~99999|
32 +|AI|AIW ddddd|0~~99999|
33 +|AQ|VB ddddd|0~~99999|
34 +|V|VW ddddd|0~~99998|(((
35 +VW0=VB (0~~1)
36 +
37 +VW2=VB (2~~3)
38 +
39 +Address value is a multiple of 2
40 +)))
41 +|V|VD ddddd|0~~99998|(((
42 +VD0=VB (0~~3)
43 +
44 +VD2=VB (4~~7)
45 +
46 +Address value is a multiple of 4
47 +)))
48 +|M|MB ddddd|0~~99999|
49 +|M|MW ddddd|0~~99999|(((
50 +MW0=MB(0~~1)
51 +
52 +MW2=MB(2~~3)
53 +
54 +Address value is a multiple of 2
55 +)))
56 +|M|MD ddddd|0~~99999|(((
57 +MD0=MB(0~~3)
58 +
59 +MD4=MB(4~~7)
60 +
61 +Address value is a multiple of 4
62 +)))
63 +|T|TW ddddd|0~~99999|Value of timer
64 +|C|CW ddddd|0~~99999|Value of counter
65 +|W|SW ddddd|0~~99999|
66 +
67 +**PLC setting**
68 +
9 9  (% style="text-align:center" %)
10 10  [[image:西门子软件版本.png]]
11 11  
12 -**2)Ethernet Configuration**
13 -
14 14  (% style="text-align:center" %)
15 -[[image:以太网通讯配置.png]]
73 +[[image:485通讯配置.png]]
16 16  
17 -**3)Connect PC software**
75 +**Connect and Download**
18 18  
19 19  (% style="text-align:center" %)
78 +[[image:以太网 PC和PLC连接.png]]
79 +
80 +(% style="text-align:center" %)
20 20  [[image:以太网下载.png]]
21 21  
22 -**4)Configure of V-net**
83 +**Cable Wiring**
23 23  
24 24  (% style="text-align:center" %)
86 +[[image:485接线.png]]
87 +
88 +== **S7-200 Smart Ethernet ** ==
89 +
90 +**V-BOX setting**
91 +
92 +|**Items**|**Settings**
93 +|Protocol|Siemens S7-200 Smart(Ethernet)
94 +|Connection|Ethernet
95 +|Port No.|102
96 +|PLC station No.|2
97 +
98 +(% style="text-align:center" %)
25 25  [[image:西门子200smart 以太网.png]]
26 26  
27 -**5)wiring**
101 +**PLC setting**
28 28  
103 +(% style="text-align:center" %)
104 +[[image:西门子软件版本.png]]
29 29  
106 +(% style="text-align:center" %)
107 +[[image:以太网通讯配置.png]]
108 +
109 +**Connect and Download**
110 +
111 +(% style="text-align:center" %)
112 +[[image:以太网 PC和PLC连接.png]]
113 +
114 +(% style="text-align:center" %)
115 +[[image:以太网下载.png]]
116 +
117 +**Cable Wiring**
118 +
30 30  V-Box : RJ45 Ethernet interface
31 31  
32 32  PLC : RJ45 Ethernet interface
... ... @@ -34,13 +34,11 @@
34 34  (% style="text-align:center" %)
35 35  [[image:以太网连接.png]]
36 36  
37 -
126 +== **S7-300 Ethernet ** ==
38 38  
39 -== {{id name="HS7-300Ethernet"/}}**S7-300 Ethernet ** ==
40 -
41 41  Supported Series: Siemens S7-300 series PLC
42 42  
43 -**1)V-BOX setting**
130 +**V-BOX setting**
44 44  
45 45  |**Items**|**Settings**|**Note**
46 46  |Protocol|Simens S7-300 Ethernet|
... ... @@ -48,21 +48,21 @@
48 48  |Port No.|102|
49 49  |PLC station No.|2|Need to be same as the PLC setting
50 50  
51 -**2)Address List**
138 +**Address List**
52 52  
53 -|**Type**|**Device register**|**HMI register**|**Format**|**Range**|**Note**
54 -|(% rowspan="4" %)Bit|I|I|I ddddd.o|0.0~~99999.7|
55 -|Q|Q|Q ddddd.o|0.0~~99999.7|
56 -|M|M|M ddddd.o|0.0~~99999.7|
57 -|DB0.DB~~DB99.DB|DBxDBD|DBxDB nndddd.o|0.0~~99999999.7|(((
140 +|**Type**|**Device register**|**Format**|**Range**|**Note**
141 +|(% rowspan="4" %)Bit|I|I ddddd.o|0.0~~99999.7|
142 +|Q|Q ddddd.o|0.0~~99999.7|
143 +|M|M ddddd.o|0.0~~99999.7|
144 +|DB0.DB~~DB99.DB|DBxDB nndddd.o|0.0~~99999999.7|(((
58 58  nn: block number;
59 59  
60 60  dddd: address;
61 61  )))
62 -|(% rowspan="8" %)Word|I|IW|IW ddddd|0~~99999|
63 -|Q|QW|QW ddddd|0~~99999|
64 -|(% rowspan="3" %)M|MB|MB ddddd|0~~99999|
65 -|MW|MW ddddd|0~~99999|(((
149 +|(% rowspan="8" %)Word|I|IW ddddd|0~~99999|
150 +|Q|QW ddddd|0~~99999|
151 +|(% rowspan="3" %)M|MB ddddd|0~~99999|
152 +|MW ddddd|0~~99999|(((
66 66  MW0=MB(0~~1)
67 67  
68 68  MW2=MB(2~~3)
... ... @@ -69,7 +69,7 @@
69 69  
70 70  Address value is a multiple of 2
71 71  )))
72 -|MD|MD ddddd|0~~99999|(((
159 +|MD ddddd|0~~99999|(((
73 73  MD0=MB(0~~3)
74 74  
75 75  MD4=MB(4~~7)
... ... @@ -76,49 +76,36 @@
76 76  
77 77  Address value is a multiple of 4
78 78  )))
79 -|(% rowspan="3" %)DB0.DB~~DB99.DB|DBxDBB|DBxDBB nndddd|0~~99999999|(% rowspan="3" %)(((
166 +|(% rowspan="3" %)DB0.DB~~DB99.DB|DBxDBB nndddd|0~~99999999|(% rowspan="3" %)(((
80 80  nn: block number;
81 81  
82 82  dddd: address
83 83  )))
84 -|DBxDBW|DBxDBW nndddd|0~~99999999
85 -|DBxDBD|DBxDBD nndddd|0~~99999999
171 +|DBxDBW nndddd|0~~99999999
172 +|DBxDBD nndddd|0~~99999999
86 86  
87 -**3)Configure the communication protocol**
174 +**Configure the communication protocol**
88 88  
89 -{{id name="Iimage-20220824161345-1.png"/}}[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_8e00ed9483ddb629.png||alt="image-20220824161345-1.png" height="1011" width="1920"]]
176 +[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_8e00ed9483ddb629.png||alt="image-20220824161345-1.png" height="1011" width="1920"]]
90 90  
91 -**4)Cable Wiring**
178 +**Cable Wiring**
92 92  
93 -{{id name="Iimage-20220824161450-2.png"/}}[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_ac8ece9a26719fda.png||alt="image-20220824161450-2.png" height="170" width="401"]]
180 +[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_ac8ece9a26719fda.png||alt="image-20220824161450-2.png" height="170" width="401"]]
94 94  
95 -== {{id name="HS7-1200A0Ethernet"/}}**S7-1200 Ethernet ** ==
182 +== **S7-1200 Ethernet ** ==
96 96  
97 97  [[download link>>url:https://ftp.we-con.com.cn/Download/WIKI/V-BOX/Demo/%E9%80%9A%E8%AE%AF%E6%A1%88%E4%BE%8B/Communicate%20with%20S7-1200%20via%20Ehernet.zip]]
98 98  
99 -== {{id name="HS7-XXXEthernetl"/}}**S7-XXX Ethernet l** ==
186 +**V-BOX Setting**
100 100  
101 -Supported Series: Siemens S7-400, S7-1200 and S7-1500
102 -
103 -**1)V-BOX setting**
104 -
105 -|=**Items**|=**Settings**|=**Note**
106 -|Protocol|Siemens S7-XXX|
188 +|**Items**|**Settings**|**Note**
189 +|Protocol|Siemens S7-1200|
107 107  |Connection|Ethernet|
108 108  |Port No.|102|
109 -|Device No.|Slot (Default 1 for S7-1500/ 2 for S7-1200/ 3 for S7-400)|
110 -|HMI No.|Rack (Default as 0)|
192 +|PLC station No.|2|
111 111  
112 -Slot from TIA Portal is equal to Device No. of V-net
194 +**Address List**
113 113  
114 -Rack from TIA Portal is equal to HMI No. of V-net
115 -
116 -{{id name="Iimage-20220824162459-3.png"/}}[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_d78bc267e5fc6394.png||alt="image-20220824162459-3.png" height="503" width="798"]]
117 -
118 -{{id name="Iimage-20220824163305-2.png"/}}[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_c9ae84ef5d418580.png||alt="image-20220824163305-2.png" height="1009" width="1920"]]
119 -
120 -**2)Address List**
121 -
122 122  |**Type**|**Device register**|**HMI register**|**Format**|**Range**|**Note**
123 123  |(% rowspan="4" %)Bit|I|I|M d.o|(((
124 124  d:0~-~-9999
... ... @@ -197,18 +197,123 @@
197 197  Address value is a multiple of 4
198 198  )))
199 199  
200 -**3)Configure the communication protocol**
274 +**Communication Settings**
201 201  
202 -{{id name="Iimage-20220824163448-3.png"/}}[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_9e740a8bf83ea3bf.png||alt="image-20220824163448-3.png" height="557" width="974"]]
276 +Enable HMI Ethernet in [Project Settings]
203 203  
278 +== **S7-XXX Ethernet** ==
279 +
280 +Supported Series: Siemens S7-400, S7-1200 and S7-1500
281 +
282 +**V-BOX setting**
283 +
284 +|=**Items**|=**Settings**|=**Note**
285 +|Protocol|Siemens S7-XXX|
286 +|Connection|Ethernet|
287 +|Port No.|102|
288 +|Device No.|Slot (Default 1 for S7-1500/ 2 for S7-1200/ 3 for S7-400)|
289 +|HMI No.|Rack (Default as 0)|
290 +
291 +Slot from TIA Portal is equal to Device No. of V-net
292 +
293 +Rack from TIA Portal is equal to HMI No. of V-net
294 +
295 +[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_d78bc267e5fc6394.png||alt="image-20220824162459-3.png" height="503" width="798"]]
296 +
297 +[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_c9ae84ef5d418580.png||alt="image-20220824163305-2.png" height="1009" width="1920"]]
298 +
299 +**Address List**
300 +
301 +|**Type**|**Device register**|**Format**|**Range**|**Note**
302 +|(% rowspan="4" %)Bit|I|M d.o|(((
303 +d:0~-~-9999
304 +
305 +o:0-7
306 +)))|
307 +|Q|Q d.o|(((
308 +d:0~-~-9999
309 +
310 +o:0-7
311 +)))|
312 +|M|M d.o|(((
313 +d:0~-~-9999
314 +
315 +o:0-7
316 +)))|
317 +|DB0.DB-DB99.DB|DBxDBnndddd.o|(((
318 +nn:0-9999,
319 +
320 +dddd:0-9999,
321 +
322 +o:0-7
323 +)))|(((
324 +nn:DB No.
325 +
326 +dddd:address value
327 +
328 +o: digit address
329 +)))
330 +|(% rowspan="8" %)Word|M|MB d|d:0-99999|
331 +|M|MW d|d:0-99999|(((
332 +MW0=MB(0~~1)
333 +
334 +MW2=MB(2~~3)
335 +
336 +Address value is a multiple of 2
337 +)))
338 +|M|MD d|d:0-99999|(((
339 +MD0=MB(0~~3)
340 +
341 +MD4=MB(4~~7)
342 +
343 +Address value is a multiple of 4
344 +)))
345 +|I|IW d|d:0-99999|
346 +|Q|QW d|d:0-99999|
347 +|DB0.DB-DB99.DB|DBxDBBnndddd|(((
348 +nn:0-9999
349 +
350 +dddd:0-9999
351 +)))|(((
352 +nn:DB No.
353 +
354 +dddd:address value
355 +)))
356 +|DB0.DB-DB99.DB|DBxDBWnndddd|(((
357 +nn:0-9999
358 +
359 +dddd:0-9999
360 +)))|(((
361 +nn:DB No.
362 +
363 +dddd:address value
364 +
365 +Address value is a multiple of 2
366 +)))
367 +|DB0.DB-DB99.DB|DBxDBDnndddd|(((
368 +nn:0-9999
369 +
370 +dddd:0-9999
371 +)))|(((
372 +nn:DB No.
373 +
374 +dddd:address value
375 +
376 +Address value is a multiple of 4
377 +)))
378 +
379 +**Configure the communication protocol**
380 +
381 +[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_9e740a8bf83ea3bf.png||alt="image-20220824163448-3.png" height="557" width="974"]]
382 +
204 204  **✎Note:**
205 205  
206 206  * The S7-1200 supports simultaneous connection of three devices, so the driver supports simultaneous access to PLC by three V-BOX.
207 207  * V-BOX access PLC, use S7 protocol, access PLC TSAP 02.01 (s7-1200 PROFINET interface only supports three connections, the default support), detailed reference to the system manual of S7-1200.
208 208  
209 -**4)Cable Wiring**
388 +**Cable Wiring**
210 210  
211 -{{id name="Iimage-20220824162342-2.png"/}}[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_ac8ece9a26719fda.png||alt="image-20220824162342-2.png" height="170" width="401"]]
390 +[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_ac8ece9a26719fda.png||alt="image-20220824162342-2.png" height="170" width="401"]]
212 212  
213 213  == {{id name="HLOGOEthernet"/}}**LOGO Ethernet ** ==
214 214  
... ... @@ -276,7 +276,7 @@
276 276  **function** **init**.main()
277 277   addr_setword("@W_0#HSW1200",8192) //~-~- Set the source TSAP address//
278 278   addr_setword("@W_0#HSW1201",4096) //~-~- Set the destination TSAP address//
279 - **end**
458 +**end**
280 280  
281 281  Note: The name of the test script is init, 8192 and 4096 are the data used for the test, there is no HSW address in the register option, but you can directly set the value of the corresponding address through the code.
282 282  
1697099618537-157.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.AiXia
Size
... ... @@ -1,0 +1,1 @@
1 +36.4 KB
Content
485接线.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.AiXia
Size
... ... @@ -1,0 +1,1 @@
1 +242.2 KB
Content
485通讯配置.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.AiXia
Size
... ... @@ -1,0 +1,1 @@
1 +154.4 KB
Content
以太网 PC和PLC连接.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.AiXia
Size
... ... @@ -1,0 +1,1 @@
1 +131.3 KB
Content
西门子200串口.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.AiXia
Size
... ... @@ -1,0 +1,1 @@
1 +64.5 KB
Content