From version 15.1
edited by Theodore Xu
on 2023/08/25 15:37
on 2023/08/25 15:37
Change comment:
There is no comment for this version
To version 47.1
edited by Theodore Xu
on 2024/02/27 19:56
on 2024/02/27 19:56
Change comment:
There is no comment for this version
Summary
-
Page properties (1 modified, 0 added, 0 removed)
-
Attachments (0 modified, 12 added, 0 removed)
- 1697099618537-157.png
- 485接线.png
- 485通讯配置.png
- V-NET_Client logo8.png
- xwiki_PIStudio_12.PLC+protocols_WebHome_664a826cd356c830.png
- xwiki_PIStudio_12.PLC+protocols_WebHome_78026942a88f0fdb.png
- xwiki_PIStudio_12.PLC+protocols_WebHome_872ec32d12b55aa.png
- xwiki_PIStudio_12.PLC+protocols_WebHome_8ee8d3ac3637bfc4.png
- xwiki_PIStudio_12.PLC+protocols_WebHome_ac8ece9a26719fda.png
- 以太网 PC和PLC连接.png
- 西门子1200协议参数.png
- 西门子200串口.png
Details
- Page properties
-
- Content
-
... ... @@ -1,32 +1,121 @@ 1 -= {{id name="HSiemens"/}}**Siemens** =1 +== **S7-200 Smart Serial** == 2 2 3 - ==**S7-200SmartEthernet**==3 +**V-BOX setting** 4 4 5 -[[download link>>url:https://ftp.we-con.com.cn/Download/WIKI/V-BOX/Demo/%E9%80%9A%E8%AE%AF%E6%A1%88%E4%BE%8B/Communication%20with%20S7-200%20Smart.zip]] 5 +(% style="width:1323.87px" %) 6 +|**Items**|**Settings**|**Note** 7 +|Protocol|(% style="width:783px" %)Siemens S7-200 CPU22x/Smart PPI| 8 +|Connection|(% style="width:783px" %)RS485| 9 +|Baud rate|(% style="width:783px" %)9600| 10 +|Data bit|(% style="width:783px" %)8| 11 +|Parity|(% style="width:783px" %)EVEN| 12 +|Stop bit|(% style="width:783px" %)1| 13 +|PLC station No.|(% style="width:783px" %)2| 6 6 7 -**1)PLC software** 15 +(% style="text-align:center" %) 16 +[[image:西门子200串口.png]] 8 8 18 +**Address List ** 19 + 20 +|**Type**|**Device register**|**Format**|**Range**|**Note** 21 +|(% rowspan="9" %)Bit|I|I ddddd.o|0.0~~99999.7| 22 +|Q|Q ddddd.o|0.0~~99999.7| 23 +|V|VWbit ddddd.o|0.0~~99999.7| 24 +|V|V ddddd.o|0.0~~99999.7| 25 +|M|M ddddd.o|0.0~~99999.7| 26 +|SM|ddddd.o|0.0~~99999.7| 27 +|S|ddddd.o|0.0~~99999.7|Read only 28 +|T|ddddd|0~~99999|Timer state, read only 29 +|C|ddddd|0~~99999|Counter state, read only 30 +|(% rowspan="12" %)Word|I|IW ddddd|0~~99999| 31 +|Q|QW ddddd|0~~99999| 32 +|AI|AIW ddddd|0~~99999| 33 +|AQ|VB ddddd|0~~99999| 34 +|V|VW ddddd|0~~99998|((( 35 +VW0=VB (0~~1) 36 + 37 +VW2=VB (2~~3) 38 + 39 +Address value is a multiple of 2 40 +))) 41 +|V|VD ddddd|0~~99998|((( 42 +VD0=VB (0~~3) 43 + 44 +VD2=VB (4~~7) 45 + 46 +Address value is a multiple of 4 47 +))) 48 +|M|MB ddddd|0~~99999| 49 +|M|MW ddddd|0~~99999|((( 50 +MW0=MB(0~~1) 51 + 52 +MW2=MB(2~~3) 53 + 54 +Address value is a multiple of 2 55 +))) 56 +|M|MD ddddd|0~~99999|((( 57 +MD0=MB(0~~3) 58 + 59 +MD4=MB(4~~7) 60 + 61 +Address value is a multiple of 4 62 +))) 63 +|T|TW ddddd|0~~99999|Value of timer 64 +|C|CW ddddd|0~~99999|Value of counter 65 +|W|SW ddddd|0~~99999| 66 + 67 +**PLC setting** 68 + 9 9 (% style="text-align:center" %) 10 10 [[image:西门子软件版本.png]] 11 11 12 -**2)Ethernet Configuration** 13 - 14 14 (% style="text-align:center" %) 15 -[[image: 以太网通讯配置.png]]73 +[[image:485通讯配置.png]] 16 16 17 -** 3)ConnectPCsoftware**75 +**Connect and Download** 18 18 19 19 (% style="text-align:center" %) 78 +[[image:以太网 PC和PLC连接.png]] 79 + 80 +(% style="text-align:center" %) 20 20 [[image:以太网下载.png]] 21 21 22 -** 4)Configureof V-net**83 +**Cable Wiring** 23 23 24 24 (% style="text-align:center" %) 86 +[[image:485接线.png]] 87 + 88 +== **S7-200 Smart Ethernet ** == 89 + 90 +**V-BOX setting** 91 + 92 +|**Items**|**Settings** 93 +|Protocol|Siemens S7-200 Smart(Ethernet) 94 +|Connection|Ethernet 95 +|Port No.|102 96 +|PLC station No.|2 97 + 98 +(% style="text-align:center" %) 25 25 [[image:西门子200smart 以太网.png]] 26 26 27 -** 5)wiring**101 +**PLC setting** 28 28 103 +(% style="text-align:center" %) 104 +[[image:西门子软件版本.png]] 29 29 106 +(% style="text-align:center" %) 107 +[[image:以太网通讯配置.png]] 108 + 109 +**Connect and Download** 110 + 111 +(% style="text-align:center" %) 112 +[[image:以太网 PC和PLC连接.png]] 113 + 114 +(% style="text-align:center" %) 115 +[[image:以太网下载.png]] 116 + 117 +**Cable Wiring** 118 + 30 30 V-Box : RJ45 Ethernet interface 31 31 32 32 PLC : RJ45 Ethernet interface ... ... @@ -34,13 +34,11 @@ 34 34 (% style="text-align:center" %) 35 35 [[image:以太网连接.png]] 36 36 37 - 126 +== **S7-300 Ethernet ** == 38 38 39 -== {{id name="HS7-300Ethernet"/}}**S7-300 Ethernet ** == 40 - 41 41 Supported Series: Siemens S7-300 series PLC 42 42 43 -** 1)V-BOX setting**130 +**V-BOX setting** 44 44 45 45 |**Items**|**Settings**|**Note** 46 46 |Protocol|Simens S7-300 Ethernet| ... ... @@ -48,21 +48,21 @@ 48 48 |Port No.|102| 49 49 |PLC station No.|2|Need to be same as the PLC setting 50 50 51 -** 2)Address List**138 +**Address List** 52 52 53 -|**Type**|**Device register**|** HMI register**|**Format**|**Range**|**Note**54 -|(% rowspan="4" %)Bit|I|I |Iddddd.o|0.0~~99999.7|55 -|Q|Q |Qddddd.o|0.0~~99999.7|56 -|M|M |Mddddd.o|0.0~~99999.7|57 -|DB0.DB~~DB99.DB|DBxDB D|DBxDBnndddd.o|0.0~~99999999.7|(((140 +|**Type**|**Device register**|**Format**|**Range**|**Note** 141 +|(% rowspan="4" %)Bit|I|I ddddd.o|0.0~~99999.7| 142 +|Q|Q ddddd.o|0.0~~99999.7| 143 +|M|M ddddd.o|0.0~~99999.7| 144 +|DB0.DB~~DB99.DB|DBxDB nndddd.o|0.0~~99999999.7|((( 58 58 nn: block number; 59 59 60 60 dddd: address; 61 61 ))) 62 -|(% rowspan="8" %)Word|I|IW |IWddddd|0~~99999|63 -|Q|QW |QWddddd|0~~99999|64 -|(% rowspan="3" %)M|MB |MBddddd|0~~99999|65 -|MW |MWddddd|0~~99999|(((149 +|(% rowspan="8" %)Word|I|IW ddddd|0~~99999| 150 +|Q|QW ddddd|0~~99999| 151 +|(% rowspan="3" %)M|MB ddddd|0~~99999| 152 +|MW ddddd|0~~99999|((( 66 66 MW0=MB(0~~1) 67 67 68 68 MW2=MB(2~~3) ... ... @@ -69,7 +69,7 @@ 69 69 70 70 Address value is a multiple of 2 71 71 ))) 72 -|MD |MDddddd|0~~99999|(((159 +|MD ddddd|0~~99999|((( 73 73 MD0=MB(0~~3) 74 74 75 75 MD4=MB(4~~7) ... ... @@ -76,49 +76,39 @@ 76 76 77 77 Address value is a multiple of 4 78 78 ))) 79 -|(% rowspan="3" %)DB0.DB~~DB99.DB|DBxDBB |DBxDBBnndddd|0~~99999999|(% rowspan="3" %)(((166 +|(% rowspan="3" %)DB0.DB~~DB99.DB|DBxDBB nndddd|0~~99999999|(% rowspan="3" %)((( 80 80 nn: block number; 81 81 82 82 dddd: address 83 83 ))) 84 -|DBxDBW |DBxDBWnndddd|0~~9999999985 -|DBxDBD |DBxDBDnndddd|0~~99999999171 +|DBxDBW nndddd|0~~99999999 172 +|DBxDBD nndddd|0~~99999999 86 86 87 -** 3)Configure the communication protocol**174 +**Configure the communication protocol** 88 88 89 - {{id name="Iimage-20220824161345-1.png"/}}[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_8e00ed9483ddb629.png||alt="image-20220824161345-1.png" height="1011" width="1920"]]176 +[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_8e00ed9483ddb629.png||alt="image-20220824161345-1.png" height="1011" width="1920"]] 90 90 91 -** 4)Cable Wiring**178 +**Cable Wiring** 92 92 93 - {{id name="Iimage-20220824161450-2.png"/}}[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_ac8ece9a26719fda.png||alt="image-20220824161450-2.png" height="170" width="401"]]180 +[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_ac8ece9a26719fda.png||alt="image-20220824161450-2.png" height="170" width="401"]] 94 94 95 -== {{id name="HS7-1200A0Ethernet"/}}**S7-1200 Ethernet ** ==182 +== **S7-1200 Ethernet ** == 96 96 97 97 [[download link>>url:https://ftp.we-con.com.cn/Download/WIKI/V-BOX/Demo/%E9%80%9A%E8%AE%AF%E6%A1%88%E4%BE%8B/Communicate%20with%20S7-1200%20via%20Ehernet.zip]] 98 98 99 - == {{id name="HS7-XXXEthernetl"/}}**S7-XXXEthernetl**==186 +**V-BOX Setting** 100 100 101 -Supported Series: Siemens S7-400, S7-1200 and S7-1500 102 - 103 -**1)V-BOX setting** 104 - 105 -|=**Items**|=**Settings**|=**Note** 106 -|Protocol|Siemens S7-XXX| 188 +|**Items**|**Settings**|**Note** 189 +|Protocol|Siemens S7-1200| 107 107 |Connection|Ethernet| 108 108 |Port No.|102| 109 -|Device No.|Slot (Default 1 for S7-1500/ 2 for S7-1200/ 3 for S7-400)| 110 -|HMI No.|Rack (Default as 0)| 192 +|PLC station No.|2| 111 111 112 -Slot from TIA Portal is equal to Device No. of V-net 194 +(% style="text-align:center" %) 195 +[[image:西门子1200协议参数.png]] 113 113 114 - Rack from TIAPortalisequalto HMI No. of V-net197 +**Address List** 115 115 116 -{{id name="Iimage-20220824162459-3.png"/}}[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_d78bc267e5fc6394.png||alt="image-20220824162459-3.png" height="503" width="798"]] 117 - 118 -{{id name="Iimage-20220824163305-2.png"/}}[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_c9ae84ef5d418580.png||alt="image-20220824163305-2.png" height="1009" width="1920"]] 119 - 120 -**2)Address List** 121 - 122 122 |**Type**|**Device register**|**HMI register**|**Format**|**Range**|**Note** 123 123 |(% rowspan="4" %)Bit|I|I|M d.o|((( 124 124 d:0~-~-9999 ... ... @@ -197,18 +197,176 @@ 197 197 Address value is a multiple of 4 198 198 ))) 199 199 200 -**3)Configure the communication protocol** 277 +{{info}} 278 +✎Note: 201 201 202 -{{id name="Iimage-20220824163448-3.png"/}}[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_9e740a8bf83ea3bf.png||alt="image-20220824163448-3.png" height="557" width="974"]] 280 +* The S7-1200 supports simultaneous connection of three devices. 281 +* V-BOX access PLC, use S7 protocol, access PLC TSAP 02.01 (S7-1200 PROFINET interface only supports three connections, the default support), detailed reference to the system manual of S7-1200. 282 +* S7-1200 String type, the default first two bytes are used to store the maximum character and valid characters, so the text data will be shifted back one word address. When interacting with the data, what way this address plc is displayed with is unknown. And because of an extra word of data causes us to display the wrong. The solution is if we use String, then the actual data address we want to operate on is actually shifted back two bytes, so as long as the address on the project is shifted back 2 bits to correspond with the actual data address. 283 +* V-BOX operation character length needs to be set to 2 times the length of the Siemens character for proper display 284 +{{/info}} 203 203 286 +**PLC Settings** 287 + 288 +Add BD 289 + 290 +* Please uncheck [Symbolic access only] option; 291 + 292 +(% style="text-align:center" %) 293 +[[image:xwiki_PIStudio_12.PLC+protocols_WebHome_872ec32d12b55aa.png]] 294 + 295 +Address settings, using BD2 as example. 296 + 297 +* DB×DBB2xxxx, DB×DBW2xxxx, DB×DBD2xxxx for accessing data of DB2 in B1. 298 +* 2 represent DB block number 299 +* xxxx represent address 300 + 301 +**Such as:** 302 + 303 +* DBxDBB20000 = DB2.DBB0 304 +* DBxDBW20004 = DB2.DBW4 305 + 306 +(% style="text-align:center" %) 307 +[[image:xwiki_PIStudio_12.PLC+protocols_WebHome_8ee8d3ac3637bfc4.png]] 308 + 309 +**How to connect with S7-1200 Firmware V4.0** 310 + 311 +PLC configuration 312 + 313 +* Double click [device configuration] in Siemens via software 314 +* Double click [protection] to enter protection configuration screen 315 + 316 +(% style="text-align:center" %) 317 +[[image:xwiki_PIStudio_12.PLC+protocols_WebHome_664a826cd356c830.png]] 318 + 319 +* Check [Permit access with PUT / GET communication from remote partner (PLC, HMI, OPC, ...)] 320 + 321 +(% style="text-align:center" %) 322 +[[image:xwiki_PIStudio_12.PLC+protocols_WebHome_78026942a88f0fdb.png]] 323 + 324 +DB settings 325 + 326 +* Right click [DB], select [properties] 327 +* Uncheck [optimized block access] 328 + 329 +**Cable Wiring** 330 + 331 +(% style="text-align:center" %) 332 +[[image:xwiki_PIStudio_12.PLC+protocols_WebHome_ac8ece9a26719fda.png]] 333 + 334 +== **S7-XXX Ethernet** == 335 + 336 +Supported Series: Siemens S7-400, S7-1200 and S7-1500 337 + 338 +**V-BOX setting** 339 + 340 +|=**Items**|=**Settings**|=**Note** 341 +|Protocol|Siemens S7-XXX| 342 +|Connection|Ethernet| 343 +|Port No.|102| 344 +|Device No.|Slot (Default 1 for S7-1500/ 2 for S7-1200/ 3 for S7-400)| 345 +|HMI No.|Rack (Default as 0)| 346 + 347 +Slot from TIA Portal is equal to Device No. of V-net 348 + 349 +Rack from TIA Portal is equal to HMI No. of V-net 350 + 351 +[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_d78bc267e5fc6394.png||alt="image-20220824162459-3.png" height="503" width="798"]] 352 + 353 +[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_c9ae84ef5d418580.png||alt="image-20220824163305-2.png" height="1009" width="1920"]] 354 + 355 +**Address List** 356 + 357 +|**Type**|**Device register**|**Format**|**Range**|**Note** 358 +|(% rowspan="4" %)Bit|I|M d.o|((( 359 +d:0~-~-9999 360 + 361 +o:0-7 362 +)))| 363 +|Q|Q d.o|((( 364 +d:0~-~-9999 365 + 366 +o:0-7 367 +)))| 368 +|M|M d.o|((( 369 +d:0~-~-9999 370 + 371 +o:0-7 372 +)))| 373 +|DB0.DB-DB99.DB|DBxDBnndddd.o|((( 374 +nn:0-9999, 375 + 376 +dddd:0-9999, 377 + 378 +o:0-7 379 +)))|((( 380 +nn:DB No. 381 + 382 +dddd:address value 383 + 384 +o: digit address 385 +))) 386 +|(% rowspan="8" %)Word|M|MB d|d:0-99999| 387 +|M|MW d|d:0-99999|((( 388 +MW0=MB(0~~1) 389 + 390 +MW2=MB(2~~3) 391 + 392 +Address value is a multiple of 2 393 +))) 394 +|M|MD d|d:0-99999|((( 395 +MD0=MB(0~~3) 396 + 397 +MD4=MB(4~~7) 398 + 399 +Address value is a multiple of 4 400 +))) 401 +|I|IW d|d:0-99999| 402 +|Q|QW d|d:0-99999| 403 +|DB0.DB-DB99.DB|DBxDBBnndddd|((( 404 +nn:0-9999 405 + 406 +dddd:0-9999 407 +)))|((( 408 +nn:DB No. 409 + 410 +dddd:address value 411 +))) 412 +|DB0.DB-DB99.DB|DBxDBWnndddd|((( 413 +nn:0-9999 414 + 415 +dddd:0-9999 416 +)))|((( 417 +nn:DB No. 418 + 419 +dddd:address value 420 + 421 +Address value is a multiple of 2 422 +))) 423 +|DB0.DB-DB99.DB|DBxDBDnndddd|((( 424 +nn:0-9999 425 + 426 +dddd:0-9999 427 +)))|((( 428 +nn:DB No. 429 + 430 +dddd:address value 431 + 432 +Address value is a multiple of 4 433 +))) 434 + 435 +**Configure the communication protocol** 436 + 437 +[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_9e740a8bf83ea3bf.png||alt="image-20220824163448-3.png" height="557" width="974"]] 438 + 204 204 **✎Note:** 205 205 206 206 * The S7-1200 supports simultaneous connection of three devices, so the driver supports simultaneous access to PLC by three V-BOX. 207 207 * V-BOX access PLC, use S7 protocol, access PLC TSAP 02.01 (s7-1200 PROFINET interface only supports three connections, the default support), detailed reference to the system manual of S7-1200. 208 208 209 -** 4)Cable Wiring**444 +**Cable Wiring** 210 210 211 - {{id name="Iimage-20220824162342-2.png"/}}[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_ac8ece9a26719fda.png||alt="image-20220824162342-2.png" height="170" width="401"]]446 +[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_ac8ece9a26719fda.png||alt="image-20220824162342-2.png" height="170" width="401"]] 212 212 213 213 == {{id name="HLOGOEthernet"/}}**LOGO Ethernet ** == 214 214 ... ... @@ -245,30 +245,28 @@ 245 245 246 246 Click [Tools]~-~-[Ethernet Connections],shown as below. 247 247 248 - {{id name="IPIStudio.125C.PLCprotocols.WebHome4012.PLCProtocol_html_8b9d2322edf89519.png"/}}[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_d13df637bfedcc52.png||alt="12.PLC Protocol_html_8b9d2322edf89519.png" height="641" width="423"]]483 +[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_d13df637bfedcc52.png||alt="12.PLC Protocol_html_8b9d2322edf89519.png" height="641" width="423"]] 249 249 250 250 Set Ethernet connection parameter. IP, Subnet Mask, shown as below. 251 251 252 - {{id name="IPIStudio.125C.PLCprotocols.WebHome40image-20221228142937-4.png"/}}[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_316247e0130c4c55.png||alt="image-20221228142937-4.png" height="484" width="366"]]487 +[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_316247e0130c4c55.png||alt="image-20221228142937-4.png" height="484" width="366"]] 253 253 254 254 **TSAP set**:The value set by local TSAP is the remote TSAP set in HMI. PLC's remote TSAP is the opposite,shown as below. 255 255 256 - {{id name="IPIStudio.125C.PLCprotocols.WebHome40image-20221228143047-5.png"/}}[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_facc6ee1af05162f.png||alt="image-20221228143047-5.png" height="626" width="1088"]]491 +[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_facc6ee1af05162f.png||alt="image-20221228143047-5.png" height="626" width="1088"]] 257 257 258 258 **Download Project**: Click "Address book" to add the IP address to be downloaded (fi."Detect" to check whether the IP address can be detected. Then click “ok”, and the system will prompt that PLC will be "STOP" mode. Click “YES” to start download. 259 259 260 - {{id name="IPIStudio.125C.PLCprotocols.WebHome40image-20221228143246-6.png"/}}[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_d43d2b7b2599ee64.png||alt="image-20221228143246-6.png" height="698" width="688"]]495 +[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_d43d2b7b2599ee64.png||alt="image-20221228143246-6.png" height="698" width="688"]] 261 261 262 262 **V-BOX Communication Settings** 263 263 264 264 Set PLC IP in [IP Address] settings; 265 265 266 -{{id name="ILldwDGntf4.png"/}}[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_ab570912d299c09.png||alt="LldwDGntf4.png" height="530" width="899"]] 501 +(% style="text-align:center" %) 502 +[[image:V-NET_Client logo8.png]] 267 267 268 -Enable V-BOX Ethernet in [Network]; 269 269 270 -{{id name="IWgvjfWbQif.png"/}}[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_637860db3ca1ca1b.png||alt="WgvjfWbQif.png" height="654" width="1195"]] 271 - 272 272 TSAP setting 273 273 274 274 * The initialization script needs to set the source TSAP address and the target TSAP address, otherwise the communication will not be successful. ... ... @@ -276,7 +276,7 @@ 276 276 **function** **init**.main() 277 277 addr_setword("@W_0#HSW1200",8192) //~-~- Set the source TSAP address// 278 278 addr_setword("@W_0#HSW1201",4096) //~-~- Set the destination TSAP address// 279 - 512 +**end** 280 280 281 281 Note: The name of the test script is init, 8192 and 4096 are the data used for the test, there is no HSW address in the register option, but you can directly set the value of the corresponding address through the code. 282 282
- 1697099618537-157.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.AiXia - Size
-
... ... @@ -1,0 +1,1 @@ 1 +36.4 KB - Content
- 485接线.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.AiXia - Size
-
... ... @@ -1,0 +1,1 @@ 1 +242.2 KB - Content
- 485通讯配置.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.AiXia - Size
-
... ... @@ -1,0 +1,1 @@ 1 +154.4 KB - Content
- V-NET_Client logo8.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.AiXia - Size
-
... ... @@ -1,0 +1,1 @@ 1 +22.4 KB - Content
- xwiki_PIStudio_12.PLC+protocols_WebHome_664a826cd356c830.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.AiXia - Size
-
... ... @@ -1,0 +1,1 @@ 1 +82.1 KB - Content
- xwiki_PIStudio_12.PLC+protocols_WebHome_78026942a88f0fdb.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.AiXia - Size
-
... ... @@ -1,0 +1,1 @@ 1 +39.3 KB - Content
- xwiki_PIStudio_12.PLC+protocols_WebHome_872ec32d12b55aa.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.AiXia - Size
-
... ... @@ -1,0 +1,1 @@ 1 +133.4 KB - Content
- xwiki_PIStudio_12.PLC+protocols_WebHome_8ee8d3ac3637bfc4.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.AiXia - Size
-
... ... @@ -1,0 +1,1 @@ 1 +96.9 KB - Content
- xwiki_PIStudio_12.PLC+protocols_WebHome_ac8ece9a26719fda.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.AiXia - Size
-
... ... @@ -1,0 +1,1 @@ 1 +107.1 KB - Content
- 以太网 PC和PLC连接.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.AiXia - Size
-
... ... @@ -1,0 +1,1 @@ 1 +131.3 KB - Content
- 西门子1200协议参数.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.AiXia - Size
-
... ... @@ -1,0 +1,1 @@ 1 +64.6 KB - Content
- 西门子200串口.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.AiXia - Size
-
... ... @@ -1,0 +1,1 @@ 1 +64.5 KB - Content