Changes for page Siemens

Last modified by Joe on 2024/08/30 14:46

From version 16.1
edited by Theodore Xu
on 2023/08/25 15:46
Change comment: There is no comment for this version
To version 45.1
edited by Theodore Xu
on 2023/10/12 16:37
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -1,41 +3,121 @@
1 -= {{id name="HSiemens"/}}**Siemens ** =
2 -
3 3  == **S7-200 Smart Serial** ==
4 4  
5 -== **S7-200 Smart Ethernet ** ==
3 +**V-BOX setting**
6 6  
7 -[[download link>>url:https://ftp.we-con.com.cn/Download/WIKI/V-BOX/Demo/%E9%80%9A%E8%AE%AF%E6%A1%88%E4%BE%8B/Communication%20with%20S7-200%20Smart.zip]]
5 +(% style="width:1323.87px" %)
6 +|**Items**|**Settings**|**Note**
7 +|Protocol|(% style="width:783px" %)Siemens S7-200 CPU22x/Smart PPI|
8 +|Connection|(% style="width:783px" %)RS485|
9 +|Baud rate|(% style="width:783px" %)9600|
10 +|Data bit|(% style="width:783px" %)8|
11 +|Parity|(% style="width:783px" %)EVEN|
12 +|Stop bit|(% style="width:783px" %)1|
13 +|PLC station No.|(% style="width:783px" %)2|
8 8  
9 -= **1)V-BOX ** =
15 +(% style="text-align:center" %)
16 +[[image:西门子200串口.png]]
10 10  
11 -|**Item**|**Settings**|**Note**
12 -|Protocol|Siemens S7-200 Smart(Ethemet)|
13 -|Connection|Ethernet|
14 -|Port No.|5002|Must be the same as the PLC setting
15 -|PLC station No.|0|
18 +**Address List **
16 16  
20 +|**Type**|**Device register**|**Format**|**Range**|**Note**
21 +|(% rowspan="9" %)Bit|I|I ddddd.o|0.0~~99999.7|
22 +|Q|Q ddddd.o|0.0~~99999.7|
23 +|V|VWbit ddddd.o|0.0~~99999.7|
24 +|V|V ddddd.o|0.0~~99999.7|
25 +|M|M ddddd.o|0.0~~99999.7|
26 +|SM|ddddd.o|0.0~~99999.7|
27 +|S|ddddd.o|0.0~~99999.7|Read only
28 +|T|ddddd|0~~99999|Timer state, read only
29 +|C|ddddd|0~~99999|Counter state, read only
30 +|(% rowspan="12" %)Word|I|IW ddddd|0~~99999|
31 +|Q|QW ddddd|0~~99999|
32 +|AI|AIW ddddd|0~~99999|
33 +|AQ|VB ddddd|0~~99999|
34 +|V|VW ddddd|0~~99998|(((
35 +VW0=VB (0~~1)
36 +
37 +VW2=VB (2~~3)
38 +
39 +Address value is a multiple of 2
40 +)))
41 +|V|VD ddddd|0~~99998|(((
42 +VD0=VB (0~~3)
43 +
44 +VD2=VB (4~~7)
45 +
46 +Address value is a multiple of 4
47 +)))
48 +|M|MB ddddd|0~~99999|
49 +|M|MW ddddd|0~~99999|(((
50 +MW0=MB(0~~1)
51 +
52 +MW2=MB(2~~3)
53 +
54 +Address value is a multiple of 2
55 +)))
56 +|M|MD ddddd|0~~99999|(((
57 +MD0=MB(0~~3)
58 +
59 +MD4=MB(4~~7)
60 +
61 +Address value is a multiple of 4
62 +)))
63 +|T|TW ddddd|0~~99999|Value of timer
64 +|C|CW ddddd|0~~99999|Value of counter
65 +|W|SW ddddd|0~~99999|
66 +
67 +**PLC setting**
68 +
17 17  (% style="text-align:center" %)
70 +[[image:西门子软件版本.png]]
71 +
72 +(% style="text-align:center" %)
73 +[[image:485通讯配置.png]]
74 +
75 +**Connect and Download**
76 +
77 +(% style="text-align:center" %)
78 +[[image:以太网 PC和PLC连接.png]]
79 +
80 +(% style="text-align:center" %)
81 +[[image:以太网下载.png]]
82 +
83 +**Cable Wiring**
84 +
85 +(% style="text-align:center" %)
86 +[[image:485接线.png]]
87 +
88 +== **S7-200 Smart Ethernet ** ==
89 +
90 +**V-BOX setting**
91 +
92 +|**Items**|**Settings**
93 +|Protocol|Siemens S7-200 Smart(Ethernet)
94 +|Connection|Ethernet
95 +|Port No.|102
96 +|PLC station No.|2
97 +
98 +(% style="text-align:center" %)
18 18  [[image:西门子200smart 以太网.png]]
19 19  
20 -**1)PLC software**
101 +**PLC setting**
21 21  
22 22  (% style="text-align:center" %)
23 23  [[image:西门子软件版本.png]]
24 24  
25 -**2)Ethernet Configuration**
26 -
27 27  (% style="text-align:center" %)
28 28  [[image:以太网通讯配置.png]]
29 29  
30 -**3)Connect PC software**
109 +**Connect and Download**
31 31  
32 32  (% style="text-align:center" %)
112 +[[image:以太网 PC和PLC连接.png]]
113 +
114 +(% style="text-align:center" %)
33 33  [[image:以太网下载.png]]
34 34  
117 +**Cable Wiring**
35 35  
36 -**5)wiring**
37 -
38 -
39 39  V-Box : RJ45 Ethernet interface
40 40  
41 41  PLC : RJ45 Ethernet interface
... ... @@ -43,13 +43,11 @@
43 43  (% style="text-align:center" %)
44 44  [[image:以太网连接.png]]
45 45  
46 -
126 +== **S7-300 Ethernet ** ==
47 47  
48 -== {{id name="HS7-300Ethernet"/}}**S7-300 Ethernet ** ==
49 -
50 50  Supported Series: Siemens S7-300 series PLC
51 51  
52 -**1)V-BOX setting**
130 +**V-BOX setting**
53 53  
54 54  |**Items**|**Settings**|**Note**
55 55  |Protocol|Simens S7-300 Ethernet|
... ... @@ -57,21 +57,21 @@
57 57  |Port No.|102|
58 58  |PLC station No.|2|Need to be same as the PLC setting
59 59  
60 -**2)Address List**
138 +**Address List**
61 61  
62 -|**Type**|**Device register**|**HMI register**|**Format**|**Range**|**Note**
63 -|(% rowspan="4" %)Bit|I|I|I ddddd.o|0.0~~99999.7|
64 -|Q|Q|Q ddddd.o|0.0~~99999.7|
65 -|M|M|M ddddd.o|0.0~~99999.7|
66 -|DB0.DB~~DB99.DB|DBxDBD|DBxDB nndddd.o|0.0~~99999999.7|(((
140 +|**Type**|**Device register**|**Format**|**Range**|**Note**
141 +|(% rowspan="4" %)Bit|I|I ddddd.o|0.0~~99999.7|
142 +|Q|Q ddddd.o|0.0~~99999.7|
143 +|M|M ddddd.o|0.0~~99999.7|
144 +|DB0.DB~~DB99.DB|DBxDB nndddd.o|0.0~~99999999.7|(((
67 67  nn: block number;
68 68  
69 69  dddd: address;
70 70  )))
71 -|(% rowspan="8" %)Word|I|IW|IW ddddd|0~~99999|
72 -|Q|QW|QW ddddd|0~~99999|
73 -|(% rowspan="3" %)M|MB|MB ddddd|0~~99999|
74 -|MW|MW ddddd|0~~99999|(((
149 +|(% rowspan="8" %)Word|I|IW ddddd|0~~99999|
150 +|Q|QW ddddd|0~~99999|
151 +|(% rowspan="3" %)M|MB ddddd|0~~99999|
152 +|MW ddddd|0~~99999|(((
75 75  MW0=MB(0~~1)
76 76  
77 77  MW2=MB(2~~3)
... ... @@ -78,7 +78,7 @@
78 78  
79 79  Address value is a multiple of 2
80 80  )))
81 -|MD|MD ddddd|0~~99999|(((
159 +|MD ddddd|0~~99999|(((
82 82  MD0=MB(0~~3)
83 83  
84 84  MD4=MB(4~~7)
... ... @@ -85,49 +85,36 @@
85 85  
86 86  Address value is a multiple of 4
87 87  )))
88 -|(% rowspan="3" %)DB0.DB~~DB99.DB|DBxDBB|DBxDBB nndddd|0~~99999999|(% rowspan="3" %)(((
166 +|(% rowspan="3" %)DB0.DB~~DB99.DB|DBxDBB nndddd|0~~99999999|(% rowspan="3" %)(((
89 89  nn: block number;
90 90  
91 91  dddd: address
92 92  )))
93 -|DBxDBW|DBxDBW nndddd|0~~99999999
94 -|DBxDBD|DBxDBD nndddd|0~~99999999
171 +|DBxDBW nndddd|0~~99999999
172 +|DBxDBD nndddd|0~~99999999
95 95  
96 -**3)Configure the communication protocol**
174 +**Configure the communication protocol**
97 97  
98 -{{id name="Iimage-20220824161345-1.png"/}}[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_8e00ed9483ddb629.png||alt="image-20220824161345-1.png" height="1011" width="1920"]]
176 +[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_8e00ed9483ddb629.png||alt="image-20220824161345-1.png" height="1011" width="1920"]]
99 99  
100 -**4)Cable Wiring**
178 +**Cable Wiring**
101 101  
102 -{{id name="Iimage-20220824161450-2.png"/}}[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_ac8ece9a26719fda.png||alt="image-20220824161450-2.png" height="170" width="401"]]
180 +[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_ac8ece9a26719fda.png||alt="image-20220824161450-2.png" height="170" width="401"]]
103 103  
104 -== {{id name="HS7-1200A0Ethernet"/}}**S7-1200 Ethernet ** ==
182 +== **S7-1200 Ethernet ** ==
105 105  
106 106  [[download link>>url:https://ftp.we-con.com.cn/Download/WIKI/V-BOX/Demo/%E9%80%9A%E8%AE%AF%E6%A1%88%E4%BE%8B/Communicate%20with%20S7-1200%20via%20Ehernet.zip]]
107 107  
108 -== {{id name="HS7-XXXEthernetl"/}}**S7-XXX Ethernet l** ==
186 +**V-BOX Setting**
109 109  
110 -Supported Series: Siemens S7-400, S7-1200 and S7-1500
111 -
112 -**1)V-BOX setting**
113 -
114 -|=**Items**|=**Settings**|=**Note**
115 -|Protocol|Siemens S7-XXX|
188 +|**Items**|**Settings**|**Note**
189 +|Protocol|Siemens S7-1200|
116 116  |Connection|Ethernet|
117 117  |Port No.|102|
118 -|Device No.|Slot (Default 1 for S7-1500/ 2 for S7-1200/ 3 for S7-400)|
119 -|HMI No.|Rack (Default as 0)|
192 +|PLC station No.|2|
120 120  
121 -Slot from TIA Portal is equal to Device No. of V-net
194 +**Address List**
122 122  
123 -Rack from TIA Portal is equal to HMI No. of V-net
124 -
125 -{{id name="Iimage-20220824162459-3.png"/}}[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_d78bc267e5fc6394.png||alt="image-20220824162459-3.png" height="503" width="798"]]
126 -
127 -{{id name="Iimage-20220824163305-2.png"/}}[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_c9ae84ef5d418580.png||alt="image-20220824163305-2.png" height="1009" width="1920"]]
128 -
129 -**2)Address List**
130 -
131 131  |**Type**|**Device register**|**HMI register**|**Format**|**Range**|**Note**
132 132  |(% rowspan="4" %)Bit|I|I|M d.o|(((
133 133  d:0~-~-9999
... ... @@ -206,18 +206,123 @@
206 206  Address value is a multiple of 4
207 207  )))
208 208  
209 -**3)Configure the communication protocol**
274 +**Communication Settings**
210 210  
211 -{{id name="Iimage-20220824163448-3.png"/}}[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_9e740a8bf83ea3bf.png||alt="image-20220824163448-3.png" height="557" width="974"]]
276 +Enable HMI Ethernet in [Project Settings]
212 212  
278 +== **S7-XXX Ethernet** ==
279 +
280 +Supported Series: Siemens S7-400, S7-1200 and S7-1500
281 +
282 +**V-BOX setting**
283 +
284 +|=**Items**|=**Settings**|=**Note**
285 +|Protocol|Siemens S7-XXX|
286 +|Connection|Ethernet|
287 +|Port No.|102|
288 +|Device No.|Slot (Default 1 for S7-1500/ 2 for S7-1200/ 3 for S7-400)|
289 +|HMI No.|Rack (Default as 0)|
290 +
291 +Slot from TIA Portal is equal to Device No. of V-net
292 +
293 +Rack from TIA Portal is equal to HMI No. of V-net
294 +
295 +[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_d78bc267e5fc6394.png||alt="image-20220824162459-3.png" height="503" width="798"]]
296 +
297 +[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_c9ae84ef5d418580.png||alt="image-20220824163305-2.png" height="1009" width="1920"]]
298 +
299 +**Address List**
300 +
301 +|**Type**|**Device register**|**Format**|**Range**|**Note**
302 +|(% rowspan="4" %)Bit|I|M d.o|(((
303 +d:0~-~-9999
304 +
305 +o:0-7
306 +)))|
307 +|Q|Q d.o|(((
308 +d:0~-~-9999
309 +
310 +o:0-7
311 +)))|
312 +|M|M d.o|(((
313 +d:0~-~-9999
314 +
315 +o:0-7
316 +)))|
317 +|DB0.DB-DB99.DB|DBxDBnndddd.o|(((
318 +nn:0-9999,
319 +
320 +dddd:0-9999,
321 +
322 +o:0-7
323 +)))|(((
324 +nn:DB No.
325 +
326 +dddd:address value
327 +
328 +o: digit address
329 +)))
330 +|(% rowspan="8" %)Word|M|MB d|d:0-99999|
331 +|M|MW d|d:0-99999|(((
332 +MW0=MB(0~~1)
333 +
334 +MW2=MB(2~~3)
335 +
336 +Address value is a multiple of 2
337 +)))
338 +|M|MD d|d:0-99999|(((
339 +MD0=MB(0~~3)
340 +
341 +MD4=MB(4~~7)
342 +
343 +Address value is a multiple of 4
344 +)))
345 +|I|IW d|d:0-99999|
346 +|Q|QW d|d:0-99999|
347 +|DB0.DB-DB99.DB|DBxDBBnndddd|(((
348 +nn:0-9999
349 +
350 +dddd:0-9999
351 +)))|(((
352 +nn:DB No.
353 +
354 +dddd:address value
355 +)))
356 +|DB0.DB-DB99.DB|DBxDBWnndddd|(((
357 +nn:0-9999
358 +
359 +dddd:0-9999
360 +)))|(((
361 +nn:DB No.
362 +
363 +dddd:address value
364 +
365 +Address value is a multiple of 2
366 +)))
367 +|DB0.DB-DB99.DB|DBxDBDnndddd|(((
368 +nn:0-9999
369 +
370 +dddd:0-9999
371 +)))|(((
372 +nn:DB No.
373 +
374 +dddd:address value
375 +
376 +Address value is a multiple of 4
377 +)))
378 +
379 +**Configure the communication protocol**
380 +
381 +[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_9e740a8bf83ea3bf.png||alt="image-20220824163448-3.png" height="557" width="974"]]
382 +
213 213  **✎Note:**
214 214  
215 215  * The S7-1200 supports simultaneous connection of three devices, so the driver supports simultaneous access to PLC by three V-BOX.
216 216  * V-BOX access PLC, use S7 protocol, access PLC TSAP 02.01 (s7-1200 PROFINET interface only supports three connections, the default support), detailed reference to the system manual of S7-1200.
217 217  
218 -**4)Cable Wiring**
388 +**Cable Wiring**
219 219  
220 -{{id name="Iimage-20220824162342-2.png"/}}[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_ac8ece9a26719fda.png||alt="image-20220824162342-2.png" height="170" width="401"]]
390 +[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_ac8ece9a26719fda.png||alt="image-20220824162342-2.png" height="170" width="401"]]
221 221  
222 222  == {{id name="HLOGOEthernet"/}}**LOGO Ethernet ** ==
223 223  
... ... @@ -285,7 +285,7 @@
285 285  **function** **init**.main()
286 286   addr_setword("@W_0#HSW1200",8192) //~-~- Set the source TSAP address//
287 287   addr_setword("@W_0#HSW1201",4096) //~-~- Set the destination TSAP address//
288 - **end**
458 +**end**
289 289  
290 290  Note: The name of the test script is init, 8192 and 4096 are the data used for the test, there is no HSW address in the register option, but you can directly set the value of the corresponding address through the code.
291 291  
1697099618537-157.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.AiXia
Size
... ... @@ -1,0 +1,1 @@
1 +36.4 KB
Content
485接线.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.AiXia
Size
... ... @@ -1,0 +1,1 @@
1 +242.2 KB
Content
485通讯配置.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.AiXia
Size
... ... @@ -1,0 +1,1 @@
1 +154.4 KB
Content
以太网 PC和PLC连接.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.AiXia
Size
... ... @@ -1,0 +1,1 @@
1 +131.3 KB
Content
西门子200串口.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.AiXia
Size
... ... @@ -1,0 +1,1 @@
1 +64.5 KB
Content