From version 16.1
edited by Theodore Xu
on 2023/08/25 15:46
on 2023/08/25 15:46
Change comment:
There is no comment for this version
To version 45.1
edited by Theodore Xu
on 2023/10/12 16:37
on 2023/10/12 16:37
Change comment:
There is no comment for this version
Summary
-
Page properties (1 modified, 0 added, 0 removed)
-
Attachments (0 modified, 5 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -1,41 +3,121 @@ 1 -= {{id name="HSiemens"/}}**Siemens ** = 2 - 3 3 == **S7-200 Smart Serial** == 4 4 5 - ==**S7-200SmartEthernet**==3 +**V-BOX setting** 6 6 7 -[[download link>>url:https://ftp.we-con.com.cn/Download/WIKI/V-BOX/Demo/%E9%80%9A%E8%AE%AF%E6%A1%88%E4%BE%8B/Communication%20with%20S7-200%20Smart.zip]] 5 +(% style="width:1323.87px" %) 6 +|**Items**|**Settings**|**Note** 7 +|Protocol|(% style="width:783px" %)Siemens S7-200 CPU22x/Smart PPI| 8 +|Connection|(% style="width:783px" %)RS485| 9 +|Baud rate|(% style="width:783px" %)9600| 10 +|Data bit|(% style="width:783px" %)8| 11 +|Parity|(% style="width:783px" %)EVEN| 12 +|Stop bit|(% style="width:783px" %)1| 13 +|PLC station No.|(% style="width:783px" %)2| 8 8 9 -= **1)V-BOX ** = 15 +(% style="text-align:center" %) 16 +[[image:西门子200串口.png]] 10 10 11 -|**Item**|**Settings**|**Note** 12 -|Protocol|Siemens S7-200 Smart(Ethemet)| 13 -|Connection|Ethernet| 14 -|Port No.|5002|Must be the same as the PLC setting 15 -|PLC station No.|0| 18 +**Address List ** 16 16 20 +|**Type**|**Device register**|**Format**|**Range**|**Note** 21 +|(% rowspan="9" %)Bit|I|I ddddd.o|0.0~~99999.7| 22 +|Q|Q ddddd.o|0.0~~99999.7| 23 +|V|VWbit ddddd.o|0.0~~99999.7| 24 +|V|V ddddd.o|0.0~~99999.7| 25 +|M|M ddddd.o|0.0~~99999.7| 26 +|SM|ddddd.o|0.0~~99999.7| 27 +|S|ddddd.o|0.0~~99999.7|Read only 28 +|T|ddddd|0~~99999|Timer state, read only 29 +|C|ddddd|0~~99999|Counter state, read only 30 +|(% rowspan="12" %)Word|I|IW ddddd|0~~99999| 31 +|Q|QW ddddd|0~~99999| 32 +|AI|AIW ddddd|0~~99999| 33 +|AQ|VB ddddd|0~~99999| 34 +|V|VW ddddd|0~~99998|((( 35 +VW0=VB (0~~1) 36 + 37 +VW2=VB (2~~3) 38 + 39 +Address value is a multiple of 2 40 +))) 41 +|V|VD ddddd|0~~99998|((( 42 +VD0=VB (0~~3) 43 + 44 +VD2=VB (4~~7) 45 + 46 +Address value is a multiple of 4 47 +))) 48 +|M|MB ddddd|0~~99999| 49 +|M|MW ddddd|0~~99999|((( 50 +MW0=MB(0~~1) 51 + 52 +MW2=MB(2~~3) 53 + 54 +Address value is a multiple of 2 55 +))) 56 +|M|MD ddddd|0~~99999|((( 57 +MD0=MB(0~~3) 58 + 59 +MD4=MB(4~~7) 60 + 61 +Address value is a multiple of 4 62 +))) 63 +|T|TW ddddd|0~~99999|Value of timer 64 +|C|CW ddddd|0~~99999|Value of counter 65 +|W|SW ddddd|0~~99999| 66 + 67 +**PLC setting** 68 + 17 17 (% style="text-align:center" %) 70 +[[image:西门子软件版本.png]] 71 + 72 +(% style="text-align:center" %) 73 +[[image:485通讯配置.png]] 74 + 75 +**Connect and Download** 76 + 77 +(% style="text-align:center" %) 78 +[[image:以太网 PC和PLC连接.png]] 79 + 80 +(% style="text-align:center" %) 81 +[[image:以太网下载.png]] 82 + 83 +**Cable Wiring** 84 + 85 +(% style="text-align:center" %) 86 +[[image:485接线.png]] 87 + 88 +== **S7-200 Smart Ethernet ** == 89 + 90 +**V-BOX setting** 91 + 92 +|**Items**|**Settings** 93 +|Protocol|Siemens S7-200 Smart(Ethernet) 94 +|Connection|Ethernet 95 +|Port No.|102 96 +|PLC station No.|2 97 + 98 +(% style="text-align:center" %) 18 18 [[image:西门子200smart 以太网.png]] 19 19 20 -** 1)PLC software**101 +**PLC setting** 21 21 22 22 (% style="text-align:center" %) 23 23 [[image:西门子软件版本.png]] 24 24 25 -**2)Ethernet Configuration** 26 - 27 27 (% style="text-align:center" %) 28 28 [[image:以太网通讯配置.png]] 29 29 30 -** 3)ConnectPCsoftware**109 +**Connect and Download** 31 31 32 32 (% style="text-align:center" %) 112 +[[image:以太网 PC和PLC连接.png]] 113 + 114 +(% style="text-align:center" %) 33 33 [[image:以太网下载.png]] 34 34 117 +**Cable Wiring** 35 35 36 -**5)wiring** 37 - 38 - 39 39 V-Box : RJ45 Ethernet interface 40 40 41 41 PLC : RJ45 Ethernet interface ... ... @@ -43,13 +43,11 @@ 43 43 (% style="text-align:center" %) 44 44 [[image:以太网连接.png]] 45 45 46 - 126 +== **S7-300 Ethernet ** == 47 47 48 -== {{id name="HS7-300Ethernet"/}}**S7-300 Ethernet ** == 49 - 50 50 Supported Series: Siemens S7-300 series PLC 51 51 52 -** 1)V-BOX setting**130 +**V-BOX setting** 53 53 54 54 |**Items**|**Settings**|**Note** 55 55 |Protocol|Simens S7-300 Ethernet| ... ... @@ -57,21 +57,21 @@ 57 57 |Port No.|102| 58 58 |PLC station No.|2|Need to be same as the PLC setting 59 59 60 -** 2)Address List**138 +**Address List** 61 61 62 -|**Type**|**Device register**|** HMI register**|**Format**|**Range**|**Note**63 -|(% rowspan="4" %)Bit|I|I |Iddddd.o|0.0~~99999.7|64 -|Q|Q |Qddddd.o|0.0~~99999.7|65 -|M|M |Mddddd.o|0.0~~99999.7|66 -|DB0.DB~~DB99.DB|DBxDB D|DBxDBnndddd.o|0.0~~99999999.7|(((140 +|**Type**|**Device register**|**Format**|**Range**|**Note** 141 +|(% rowspan="4" %)Bit|I|I ddddd.o|0.0~~99999.7| 142 +|Q|Q ddddd.o|0.0~~99999.7| 143 +|M|M ddddd.o|0.0~~99999.7| 144 +|DB0.DB~~DB99.DB|DBxDB nndddd.o|0.0~~99999999.7|((( 67 67 nn: block number; 68 68 69 69 dddd: address; 70 70 ))) 71 -|(% rowspan="8" %)Word|I|IW |IWddddd|0~~99999|72 -|Q|QW |QWddddd|0~~99999|73 -|(% rowspan="3" %)M|MB |MBddddd|0~~99999|74 -|MW |MWddddd|0~~99999|(((149 +|(% rowspan="8" %)Word|I|IW ddddd|0~~99999| 150 +|Q|QW ddddd|0~~99999| 151 +|(% rowspan="3" %)M|MB ddddd|0~~99999| 152 +|MW ddddd|0~~99999|((( 75 75 MW0=MB(0~~1) 76 76 77 77 MW2=MB(2~~3) ... ... @@ -78,7 +78,7 @@ 78 78 79 79 Address value is a multiple of 2 80 80 ))) 81 -|MD |MDddddd|0~~99999|(((159 +|MD ddddd|0~~99999|((( 82 82 MD0=MB(0~~3) 83 83 84 84 MD4=MB(4~~7) ... ... @@ -85,49 +85,36 @@ 85 85 86 86 Address value is a multiple of 4 87 87 ))) 88 -|(% rowspan="3" %)DB0.DB~~DB99.DB|DBxDBB |DBxDBBnndddd|0~~99999999|(% rowspan="3" %)(((166 +|(% rowspan="3" %)DB0.DB~~DB99.DB|DBxDBB nndddd|0~~99999999|(% rowspan="3" %)((( 89 89 nn: block number; 90 90 91 91 dddd: address 92 92 ))) 93 -|DBxDBW |DBxDBWnndddd|0~~9999999994 -|DBxDBD |DBxDBDnndddd|0~~99999999171 +|DBxDBW nndddd|0~~99999999 172 +|DBxDBD nndddd|0~~99999999 95 95 96 -** 3)Configure the communication protocol**174 +**Configure the communication protocol** 97 97 98 - {{id name="Iimage-20220824161345-1.png"/}}[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_8e00ed9483ddb629.png||alt="image-20220824161345-1.png" height="1011" width="1920"]]176 +[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_8e00ed9483ddb629.png||alt="image-20220824161345-1.png" height="1011" width="1920"]] 99 99 100 -** 4)Cable Wiring**178 +**Cable Wiring** 101 101 102 - {{id name="Iimage-20220824161450-2.png"/}}[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_ac8ece9a26719fda.png||alt="image-20220824161450-2.png" height="170" width="401"]]180 +[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_ac8ece9a26719fda.png||alt="image-20220824161450-2.png" height="170" width="401"]] 103 103 104 -== {{id name="HS7-1200A0Ethernet"/}}**S7-1200 Ethernet ** ==182 +== **S7-1200 Ethernet ** == 105 105 106 106 [[download link>>url:https://ftp.we-con.com.cn/Download/WIKI/V-BOX/Demo/%E9%80%9A%E8%AE%AF%E6%A1%88%E4%BE%8B/Communicate%20with%20S7-1200%20via%20Ehernet.zip]] 107 107 108 - == {{id name="HS7-XXXEthernetl"/}}**S7-XXXEthernetl**==186 +**V-BOX Setting** 109 109 110 -Supported Series: Siemens S7-400, S7-1200 and S7-1500 111 - 112 -**1)V-BOX setting** 113 - 114 -|=**Items**|=**Settings**|=**Note** 115 -|Protocol|Siemens S7-XXX| 188 +|**Items**|**Settings**|**Note** 189 +|Protocol|Siemens S7-1200| 116 116 |Connection|Ethernet| 117 117 |Port No.|102| 118 -|Device No.|Slot (Default 1 for S7-1500/ 2 for S7-1200/ 3 for S7-400)| 119 -|HMI No.|Rack (Default as 0)| 192 +|PLC station No.|2| 120 120 121 - Slot from TIAPortalisequalto Device No. of V-net194 +**Address List** 122 122 123 -Rack from TIA Portal is equal to HMI No. of V-net 124 - 125 -{{id name="Iimage-20220824162459-3.png"/}}[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_d78bc267e5fc6394.png||alt="image-20220824162459-3.png" height="503" width="798"]] 126 - 127 -{{id name="Iimage-20220824163305-2.png"/}}[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_c9ae84ef5d418580.png||alt="image-20220824163305-2.png" height="1009" width="1920"]] 128 - 129 -**2)Address List** 130 - 131 131 |**Type**|**Device register**|**HMI register**|**Format**|**Range**|**Note** 132 132 |(% rowspan="4" %)Bit|I|I|M d.o|((( 133 133 d:0~-~-9999 ... ... @@ -206,18 +206,123 @@ 206 206 Address value is a multiple of 4 207 207 ))) 208 208 209 -** 3)Configure the communicationprotocol**274 +**Communication Settings** 210 210 211 - {{idname="Iimage-20220824163448-3.png"/}}[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_9e740a8bf83ea3bf.png||alt="image-20220824163448-3.png" height="557" width="974"]]276 +Enable HMI Ethernet in [Project Settings] 212 212 278 +== **S7-XXX Ethernet** == 279 + 280 +Supported Series: Siemens S7-400, S7-1200 and S7-1500 281 + 282 +**V-BOX setting** 283 + 284 +|=**Items**|=**Settings**|=**Note** 285 +|Protocol|Siemens S7-XXX| 286 +|Connection|Ethernet| 287 +|Port No.|102| 288 +|Device No.|Slot (Default 1 for S7-1500/ 2 for S7-1200/ 3 for S7-400)| 289 +|HMI No.|Rack (Default as 0)| 290 + 291 +Slot from TIA Portal is equal to Device No. of V-net 292 + 293 +Rack from TIA Portal is equal to HMI No. of V-net 294 + 295 +[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_d78bc267e5fc6394.png||alt="image-20220824162459-3.png" height="503" width="798"]] 296 + 297 +[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_c9ae84ef5d418580.png||alt="image-20220824163305-2.png" height="1009" width="1920"]] 298 + 299 +**Address List** 300 + 301 +|**Type**|**Device register**|**Format**|**Range**|**Note** 302 +|(% rowspan="4" %)Bit|I|M d.o|((( 303 +d:0~-~-9999 304 + 305 +o:0-7 306 +)))| 307 +|Q|Q d.o|((( 308 +d:0~-~-9999 309 + 310 +o:0-7 311 +)))| 312 +|M|M d.o|((( 313 +d:0~-~-9999 314 + 315 +o:0-7 316 +)))| 317 +|DB0.DB-DB99.DB|DBxDBnndddd.o|((( 318 +nn:0-9999, 319 + 320 +dddd:0-9999, 321 + 322 +o:0-7 323 +)))|((( 324 +nn:DB No. 325 + 326 +dddd:address value 327 + 328 +o: digit address 329 +))) 330 +|(% rowspan="8" %)Word|M|MB d|d:0-99999| 331 +|M|MW d|d:0-99999|((( 332 +MW0=MB(0~~1) 333 + 334 +MW2=MB(2~~3) 335 + 336 +Address value is a multiple of 2 337 +))) 338 +|M|MD d|d:0-99999|((( 339 +MD0=MB(0~~3) 340 + 341 +MD4=MB(4~~7) 342 + 343 +Address value is a multiple of 4 344 +))) 345 +|I|IW d|d:0-99999| 346 +|Q|QW d|d:0-99999| 347 +|DB0.DB-DB99.DB|DBxDBBnndddd|((( 348 +nn:0-9999 349 + 350 +dddd:0-9999 351 +)))|((( 352 +nn:DB No. 353 + 354 +dddd:address value 355 +))) 356 +|DB0.DB-DB99.DB|DBxDBWnndddd|((( 357 +nn:0-9999 358 + 359 +dddd:0-9999 360 +)))|((( 361 +nn:DB No. 362 + 363 +dddd:address value 364 + 365 +Address value is a multiple of 2 366 +))) 367 +|DB0.DB-DB99.DB|DBxDBDnndddd|((( 368 +nn:0-9999 369 + 370 +dddd:0-9999 371 +)))|((( 372 +nn:DB No. 373 + 374 +dddd:address value 375 + 376 +Address value is a multiple of 4 377 +))) 378 + 379 +**Configure the communication protocol** 380 + 381 +[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_9e740a8bf83ea3bf.png||alt="image-20220824163448-3.png" height="557" width="974"]] 382 + 213 213 **✎Note:** 214 214 215 215 * The S7-1200 supports simultaneous connection of three devices, so the driver supports simultaneous access to PLC by three V-BOX. 216 216 * V-BOX access PLC, use S7 protocol, access PLC TSAP 02.01 (s7-1200 PROFINET interface only supports three connections, the default support), detailed reference to the system manual of S7-1200. 217 217 218 -** 4)Cable Wiring**388 +**Cable Wiring** 219 219 220 - {{id name="Iimage-20220824162342-2.png"/}}[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_ac8ece9a26719fda.png||alt="image-20220824162342-2.png" height="170" width="401"]]390 +[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_ac8ece9a26719fda.png||alt="image-20220824162342-2.png" height="170" width="401"]] 221 221 222 222 == {{id name="HLOGOEthernet"/}}**LOGO Ethernet ** == 223 223 ... ... @@ -285,7 +285,7 @@ 285 285 **function** **init**.main() 286 286 addr_setword("@W_0#HSW1200",8192) //~-~- Set the source TSAP address// 287 287 addr_setword("@W_0#HSW1201",4096) //~-~- Set the destination TSAP address// 288 - 458 +**end** 289 289 290 290 Note: The name of the test script is init, 8192 and 4096 are the data used for the test, there is no HSW address in the register option, but you can directly set the value of the corresponding address through the code. 291 291
- 1697099618537-157.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.AiXia - Size
-
... ... @@ -1,0 +1,1 @@ 1 +36.4 KB - Content
- 485接线.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.AiXia - Size
-
... ... @@ -1,0 +1,1 @@ 1 +242.2 KB - Content
- 485通讯配置.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.AiXia - Size
-
... ... @@ -1,0 +1,1 @@ 1 +154.4 KB - Content
- 以太网 PC和PLC连接.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.AiXia - Size
-
... ... @@ -1,0 +1,1 @@ 1 +131.3 KB - Content
- 西门子200串口.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.AiXia - Size
-
... ... @@ -1,0 +1,1 @@ 1 +64.5 KB - Content