From version 22.1
edited by Theodore Xu
on 2023/08/25 16:40
on 2023/08/25 16:40
Change comment:
There is no comment for this version
To version 46.1
edited by Theodore Xu
on 2023/10/12 17:06
on 2023/10/12 17:06
Change comment:
There is no comment for this version
Summary
-
Page properties (1 modified, 0 added, 0 removed)
-
Attachments (0 modified, 7 added, 0 removed)
- 1697099618537-157.png
- xwiki_PIStudio_12.PLC+protocols_WebHome_664a826cd356c830.png
- xwiki_PIStudio_12.PLC+protocols_WebHome_78026942a88f0fdb.png
- xwiki_PIStudio_12.PLC+protocols_WebHome_872ec32d12b55aa.png
- xwiki_PIStudio_12.PLC+protocols_WebHome_8ee8d3ac3637bfc4.png
- xwiki_PIStudio_12.PLC+protocols_WebHome_ac8ece9a26719fda.png
- 西门子1200协议参数.png
Details
- Page properties
-
- Content
-
... ... @@ -1,23 +3,78 @@ 1 -= {{id name="HSiemens"/}}**Siemens ** = 2 - 3 3 == **S7-200 Smart Serial** == 4 4 5 -** 1)V-BOXProtocol:Siemens S7-200 CPU22x/Smart PPI**3 +**V-BOX setting** 6 6 5 +(% style="width:1323.87px" %) 6 +|**Items**|**Settings**|**Note** 7 +|Protocol|(% style="width:783px" %)Siemens S7-200 CPU22x/Smart PPI| 8 +|Connection|(% style="width:783px" %)RS485| 9 +|Baud rate|(% style="width:783px" %)9600| 10 +|Data bit|(% style="width:783px" %)8| 11 +|Parity|(% style="width:783px" %)EVEN| 12 +|Stop bit|(% style="width:783px" %)1| 13 +|PLC station No.|(% style="width:783px" %)2| 14 + 7 7 (% style="text-align:center" %) 8 8 [[image:西门子200串口.png]] 9 9 10 -** 2)PLCsoftware**18 +**Address List ** 11 11 20 +|**Type**|**Device register**|**Format**|**Range**|**Note** 21 +|(% rowspan="9" %)Bit|I|I ddddd.o|0.0~~99999.7| 22 +|Q|Q ddddd.o|0.0~~99999.7| 23 +|V|VWbit ddddd.o|0.0~~99999.7| 24 +|V|V ddddd.o|0.0~~99999.7| 25 +|M|M ddddd.o|0.0~~99999.7| 26 +|SM|ddddd.o|0.0~~99999.7| 27 +|S|ddddd.o|0.0~~99999.7|Read only 28 +|T|ddddd|0~~99999|Timer state, read only 29 +|C|ddddd|0~~99999|Counter state, read only 30 +|(% rowspan="12" %)Word|I|IW ddddd|0~~99999| 31 +|Q|QW ddddd|0~~99999| 32 +|AI|AIW ddddd|0~~99999| 33 +|AQ|VB ddddd|0~~99999| 34 +|V|VW ddddd|0~~99998|((( 35 +VW0=VB (0~~1) 36 + 37 +VW2=VB (2~~3) 38 + 39 +Address value is a multiple of 2 40 +))) 41 +|V|VD ddddd|0~~99998|((( 42 +VD0=VB (0~~3) 43 + 44 +VD2=VB (4~~7) 45 + 46 +Address value is a multiple of 4 47 +))) 48 +|M|MB ddddd|0~~99999| 49 +|M|MW ddddd|0~~99999|((( 50 +MW0=MB(0~~1) 51 + 52 +MW2=MB(2~~3) 53 + 54 +Address value is a multiple of 2 55 +))) 56 +|M|MD ddddd|0~~99999|((( 57 +MD0=MB(0~~3) 58 + 59 +MD4=MB(4~~7) 60 + 61 +Address value is a multiple of 4 62 +))) 63 +|T|TW ddddd|0~~99999|Value of timer 64 +|C|CW ddddd|0~~99999|Value of counter 65 +|W|SW ddddd|0~~99999| 66 + 67 +**PLC setting** 68 + 12 12 (% style="text-align:center" %) 13 13 [[image:西门子软件版本.png]] 14 14 15 -**3)PLC Software Configuration** 16 - 17 17 (% style="text-align:center" %) 18 18 [[image:485通讯配置.png]] 19 19 20 -** 4)ConnectPC software and Download**75 +**Connect and Download** 21 21 22 22 (% style="text-align:center" %) 23 23 [[image:以太网 PC和PLC连接.png]] ... ... @@ -25,7 +25,7 @@ 25 25 (% style="text-align:center" %) 26 26 [[image:以太网下载.png]] 27 27 28 -** 5)wiring**83 +**Cable Wiring** 29 29 30 30 (% style="text-align:center" %) 31 31 [[image:485接线.png]] ... ... @@ -32,34 +32,34 @@ 32 32 33 33 == **S7-200 Smart Ethernet ** == 34 34 35 - [[download link>>url:https://ftp.we-con.com.cn/Download/WIKI/V-BOX/Demo/%E9%80%9A%E8%AE%AF%E6%A1%88%E4%BE%8B/Communication%20with%20S7-200%20Smart.zip]]90 +**V-BOX setting** 36 36 37 -(% class="wikigeneratedid" id="H1FF09V-BOX" %) 38 -**1)V-BOX Protocol:Siemens S7-200 Smart(Ethernet)** 92 +|**Items**|**Settings** 93 +|Protocol|Siemens S7-200 Smart(Ethernet) 94 +|Connection|Ethernet 95 +|Port No.|102 96 +|PLC station No.|2 39 39 40 40 (% style="text-align:center" %) 41 41 [[image:西门子200smart 以太网.png]] 42 42 43 -** 2)PLC software**101 +**PLC setting** 44 44 45 45 (% style="text-align:center" %) 46 46 [[image:西门子软件版本.png]] 47 47 48 -**3)PLC Software Configuration** 49 - 50 50 (% style="text-align:center" %) 51 51 [[image:以太网通讯配置.png]] 52 52 53 -** 4)ConnectPC software and Download**109 +**Connect and Download** 54 54 55 55 (% style="text-align:center" %) 56 56 [[image:以太网 PC和PLC连接.png]] 57 57 58 - 59 59 (% style="text-align:center" %) 60 60 [[image:以太网下载.png]] 61 61 62 -** 5)wiring**117 +**Cable Wiring** 63 63 64 64 V-Box : RJ45 Ethernet interface 65 65 ... ... @@ -68,11 +68,11 @@ 68 68 (% style="text-align:center" %) 69 69 [[image:以太网连接.png]] 70 70 71 -== {{id name="HS7-300Ethernet"/}}**S7-300 Ethernet ** ==126 +== **S7-300 Ethernet ** == 72 72 73 73 Supported Series: Siemens S7-300 series PLC 74 74 75 -** 1)V-BOX setting**130 +**V-BOX setting** 76 76 77 77 |**Items**|**Settings**|**Note** 78 78 |Protocol|Simens S7-300 Ethernet| ... ... @@ -80,21 +80,21 @@ 80 80 |Port No.|102| 81 81 |PLC station No.|2|Need to be same as the PLC setting 82 82 83 -** 2)Address List**138 +**Address List** 84 84 85 -|**Type**|**Device register**|** HMI register**|**Format**|**Range**|**Note**86 -|(% rowspan="4" %)Bit|I|I |Iddddd.o|0.0~~99999.7|87 -|Q|Q |Qddddd.o|0.0~~99999.7|88 -|M|M |Mddddd.o|0.0~~99999.7|89 -|DB0.DB~~DB99.DB|DBxDB D|DBxDBnndddd.o|0.0~~99999999.7|(((140 +|**Type**|**Device register**|**Format**|**Range**|**Note** 141 +|(% rowspan="4" %)Bit|I|I ddddd.o|0.0~~99999.7| 142 +|Q|Q ddddd.o|0.0~~99999.7| 143 +|M|M ddddd.o|0.0~~99999.7| 144 +|DB0.DB~~DB99.DB|DBxDB nndddd.o|0.0~~99999999.7|((( 90 90 nn: block number; 91 91 92 92 dddd: address; 93 93 ))) 94 -|(% rowspan="8" %)Word|I|IW |IWddddd|0~~99999|95 -|Q|QW |QWddddd|0~~99999|96 -|(% rowspan="3" %)M|MB |MBddddd|0~~99999|97 -|MW |MWddddd|0~~99999|(((149 +|(% rowspan="8" %)Word|I|IW ddddd|0~~99999| 150 +|Q|QW ddddd|0~~99999| 151 +|(% rowspan="3" %)M|MB ddddd|0~~99999| 152 +|MW ddddd|0~~99999|((( 98 98 MW0=MB(0~~1) 99 99 100 100 MW2=MB(2~~3) ... ... @@ -101,7 +101,7 @@ 101 101 102 102 Address value is a multiple of 2 103 103 ))) 104 -|MD |MDddddd|0~~99999|(((159 +|MD ddddd|0~~99999|((( 105 105 MD0=MB(0~~3) 106 106 107 107 MD4=MB(4~~7) ... ... @@ -108,49 +108,39 @@ 108 108 109 109 Address value is a multiple of 4 110 110 ))) 111 -|(% rowspan="3" %)DB0.DB~~DB99.DB|DBxDBB |DBxDBBnndddd|0~~99999999|(% rowspan="3" %)(((166 +|(% rowspan="3" %)DB0.DB~~DB99.DB|DBxDBB nndddd|0~~99999999|(% rowspan="3" %)((( 112 112 nn: block number; 113 113 114 114 dddd: address 115 115 ))) 116 -|DBxDBW |DBxDBWnndddd|0~~99999999117 -|DBxDBD |DBxDBDnndddd|0~~99999999171 +|DBxDBW nndddd|0~~99999999 172 +|DBxDBD nndddd|0~~99999999 118 118 119 -** 3)Configure the communication protocol**174 +**Configure the communication protocol** 120 120 121 - {{id name="Iimage-20220824161345-1.png"/}}[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_8e00ed9483ddb629.png||alt="image-20220824161345-1.png" height="1011" width="1920"]]176 +[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_8e00ed9483ddb629.png||alt="image-20220824161345-1.png" height="1011" width="1920"]] 122 122 123 -** 4)Cable Wiring**178 +**Cable Wiring** 124 124 125 - {{id name="Iimage-20220824161450-2.png"/}}[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_ac8ece9a26719fda.png||alt="image-20220824161450-2.png" height="170" width="401"]]180 +[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_ac8ece9a26719fda.png||alt="image-20220824161450-2.png" height="170" width="401"]] 126 126 127 -== {{id name="HS7-1200A0Ethernet"/}}**S7-1200 Ethernet ** ==182 +== **S7-1200 Ethernet ** == 128 128 129 129 [[download link>>url:https://ftp.we-con.com.cn/Download/WIKI/V-BOX/Demo/%E9%80%9A%E8%AE%AF%E6%A1%88%E4%BE%8B/Communicate%20with%20S7-1200%20via%20Ehernet.zip]] 130 130 131 - == {{id name="HS7-XXXEthernetl"/}}**S7-XXXEthernetl**==186 +**V-BOX Setting** 132 132 133 -Supported Series: Siemens S7-400, S7-1200 and S7-1500 134 - 135 -**1)V-BOX setting** 136 - 137 -|=**Items**|=**Settings**|=**Note** 138 -|Protocol|Siemens S7-XXX| 188 +|**Items**|**Settings**|**Note** 189 +|Protocol|Siemens S7-1200| 139 139 |Connection|Ethernet| 140 140 |Port No.|102| 141 -|Device No.|Slot (Default 1 for S7-1500/ 2 for S7-1200/ 3 for S7-400)| 142 -|HMI No.|Rack (Default as 0)| 192 +|PLC station No.|2| 143 143 144 -Slot from TIA Portal is equal to Device No. of V-net 194 +(% style="text-align:center" %) 195 +[[image:西门子1200协议参数.png]] 145 145 146 - Rack from TIAPortalisequalto HMI No. of V-net197 +**Address List** 147 147 148 -{{id name="Iimage-20220824162459-3.png"/}}[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_d78bc267e5fc6394.png||alt="image-20220824162459-3.png" height="503" width="798"]] 149 - 150 -{{id name="Iimage-20220824163305-2.png"/}}[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_c9ae84ef5d418580.png||alt="image-20220824163305-2.png" height="1009" width="1920"]] 151 - 152 -**2)Address List** 153 - 154 154 |**Type**|**Device register**|**HMI register**|**Format**|**Range**|**Note** 155 155 |(% rowspan="4" %)Bit|I|I|M d.o|((( 156 156 d:0~-~-9999 ... ... @@ -229,18 +229,176 @@ 229 229 Address value is a multiple of 4 230 230 ))) 231 231 232 -**3)Configure the communication protocol** 277 +{{info}} 278 +✎Note: 233 233 234 -{{id name="Iimage-20220824163448-3.png"/}}[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_9e740a8bf83ea3bf.png||alt="image-20220824163448-3.png" height="557" width="974"]] 280 +* The S7-1200 supports simultaneous connection of three devices. 281 +* V-BOX access PLC, use S7 protocol, access PLC TSAP 02.01 (S7-1200 PROFINET interface only supports three connections, the default support), detailed reference to the system manual of S7-1200. 282 +* S7-1200 String type, the default first two bytes are used to store the maximum character and valid characters, so the text data will be shifted back one word address. When interacting with the data, what way this address plc is displayed with is unknown. And because of an extra word of data causes us to display the wrong. The solution is if we use String, then the actual data address we want to operate on is actually shifted back two bytes, so as long as the address on the project is shifted back 2 bits to correspond with the actual data address. 283 +* V-BOX operation character length needs to be set to 2 times the length of the Siemens character for proper display 284 +{{/info}} 235 235 286 +**PLC Settings** 287 + 288 +Add BD 289 + 290 +* Please uncheck [Symbolic access only] option; 291 + 292 +(% style="text-align:center" %) 293 +[[image:xwiki_PIStudio_12.PLC+protocols_WebHome_872ec32d12b55aa.png]] 294 + 295 +Address settings, using BD2 as example. 296 + 297 +* DB×DBB2xxxx, DB×DBW2xxxx, DB×DBD2xxxx for accessing data of DB2 in B1. 298 +* 2 represent DB block number 299 +* xxxx represent address 300 + 301 +**Such as:** 302 + 303 +* DBxDBB20000 = DB2.DBB0 304 +* DBxDBW20004 = DB2.DBW4 305 + 306 +(% style="text-align:center" %) 307 +[[image:xwiki_PIStudio_12.PLC+protocols_WebHome_8ee8d3ac3637bfc4.png]] 308 + 309 +**How to connect with S7-1200 Firmware V4.0** 310 + 311 +PLC configuration 312 + 313 +* Double click [device configuration] in Siemens via software 314 +* Double click [protection] to enter protection configuration screen 315 + 316 +(% style="text-align:center" %) 317 +[[image:xwiki_PIStudio_12.PLC+protocols_WebHome_664a826cd356c830.png]] 318 + 319 +* Check [Permit access with PUT / GET communication from remote partner (PLC, HMI, OPC, ...)] 320 + 321 +(% style="text-align:center" %) 322 +[[image:xwiki_PIStudio_12.PLC+protocols_WebHome_78026942a88f0fdb.png]] 323 + 324 +DB settings 325 + 326 +* Right click [DB], select [properties] 327 +* Uncheck [optimized block access] 328 + 329 +**Cable Wiring** 330 + 331 +(% style="text-align:center" %) 332 +[[image:xwiki_PIStudio_12.PLC+protocols_WebHome_ac8ece9a26719fda.png]] 333 + 334 +== **S7-XXX Ethernet** == 335 + 336 +Supported Series: Siemens S7-400, S7-1200 and S7-1500 337 + 338 +**V-BOX setting** 339 + 340 +|=**Items**|=**Settings**|=**Note** 341 +|Protocol|Siemens S7-XXX| 342 +|Connection|Ethernet| 343 +|Port No.|102| 344 +|Device No.|Slot (Default 1 for S7-1500/ 2 for S7-1200/ 3 for S7-400)| 345 +|HMI No.|Rack (Default as 0)| 346 + 347 +Slot from TIA Portal is equal to Device No. of V-net 348 + 349 +Rack from TIA Portal is equal to HMI No. of V-net 350 + 351 +[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_d78bc267e5fc6394.png||alt="image-20220824162459-3.png" height="503" width="798"]] 352 + 353 +[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_c9ae84ef5d418580.png||alt="image-20220824163305-2.png" height="1009" width="1920"]] 354 + 355 +**Address List** 356 + 357 +|**Type**|**Device register**|**Format**|**Range**|**Note** 358 +|(% rowspan="4" %)Bit|I|M d.o|((( 359 +d:0~-~-9999 360 + 361 +o:0-7 362 +)))| 363 +|Q|Q d.o|((( 364 +d:0~-~-9999 365 + 366 +o:0-7 367 +)))| 368 +|M|M d.o|((( 369 +d:0~-~-9999 370 + 371 +o:0-7 372 +)))| 373 +|DB0.DB-DB99.DB|DBxDBnndddd.o|((( 374 +nn:0-9999, 375 + 376 +dddd:0-9999, 377 + 378 +o:0-7 379 +)))|((( 380 +nn:DB No. 381 + 382 +dddd:address value 383 + 384 +o: digit address 385 +))) 386 +|(% rowspan="8" %)Word|M|MB d|d:0-99999| 387 +|M|MW d|d:0-99999|((( 388 +MW0=MB(0~~1) 389 + 390 +MW2=MB(2~~3) 391 + 392 +Address value is a multiple of 2 393 +))) 394 +|M|MD d|d:0-99999|((( 395 +MD0=MB(0~~3) 396 + 397 +MD4=MB(4~~7) 398 + 399 +Address value is a multiple of 4 400 +))) 401 +|I|IW d|d:0-99999| 402 +|Q|QW d|d:0-99999| 403 +|DB0.DB-DB99.DB|DBxDBBnndddd|((( 404 +nn:0-9999 405 + 406 +dddd:0-9999 407 +)))|((( 408 +nn:DB No. 409 + 410 +dddd:address value 411 +))) 412 +|DB0.DB-DB99.DB|DBxDBWnndddd|((( 413 +nn:0-9999 414 + 415 +dddd:0-9999 416 +)))|((( 417 +nn:DB No. 418 + 419 +dddd:address value 420 + 421 +Address value is a multiple of 2 422 +))) 423 +|DB0.DB-DB99.DB|DBxDBDnndddd|((( 424 +nn:0-9999 425 + 426 +dddd:0-9999 427 +)))|((( 428 +nn:DB No. 429 + 430 +dddd:address value 431 + 432 +Address value is a multiple of 4 433 +))) 434 + 435 +**Configure the communication protocol** 436 + 437 +[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_9e740a8bf83ea3bf.png||alt="image-20220824163448-3.png" height="557" width="974"]] 438 + 236 236 **✎Note:** 237 237 238 238 * The S7-1200 supports simultaneous connection of three devices, so the driver supports simultaneous access to PLC by three V-BOX. 239 239 * V-BOX access PLC, use S7 protocol, access PLC TSAP 02.01 (s7-1200 PROFINET interface only supports three connections, the default support), detailed reference to the system manual of S7-1200. 240 240 241 -** 4)Cable Wiring**444 +**Cable Wiring** 242 242 243 - {{id name="Iimage-20220824162342-2.png"/}}[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_ac8ece9a26719fda.png||alt="image-20220824162342-2.png" height="170" width="401"]]446 +[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_ac8ece9a26719fda.png||alt="image-20220824162342-2.png" height="170" width="401"]] 244 244 245 245 == {{id name="HLOGOEthernet"/}}**LOGO Ethernet ** == 246 246 ... ... @@ -277,19 +277,19 @@ 277 277 278 278 Click [Tools]~-~-[Ethernet Connections],shown as below. 279 279 280 - {{id name="IPIStudio.125C.PLCprotocols.WebHome4012.PLCProtocol_html_8b9d2322edf89519.png"/}}[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_d13df637bfedcc52.png||alt="12.PLC Protocol_html_8b9d2322edf89519.png" height="641" width="423"]]483 +[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_d13df637bfedcc52.png||alt="12.PLC Protocol_html_8b9d2322edf89519.png" height="641" width="423"]] 281 281 282 282 Set Ethernet connection parameter. IP, Subnet Mask, shown as below. 283 283 284 - {{id name="IPIStudio.125C.PLCprotocols.WebHome40image-20221228142937-4.png"/}}[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_316247e0130c4c55.png||alt="image-20221228142937-4.png" height="484" width="366"]]487 +[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_316247e0130c4c55.png||alt="image-20221228142937-4.png" height="484" width="366"]] 285 285 286 286 **TSAP set**:The value set by local TSAP is the remote TSAP set in HMI. PLC's remote TSAP is the opposite,shown as below. 287 287 288 - {{id name="IPIStudio.125C.PLCprotocols.WebHome40image-20221228143047-5.png"/}}[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_facc6ee1af05162f.png||alt="image-20221228143047-5.png" height="626" width="1088"]]491 +[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_facc6ee1af05162f.png||alt="image-20221228143047-5.png" height="626" width="1088"]] 289 289 290 290 **Download Project**: Click "Address book" to add the IP address to be downloaded (fi."Detect" to check whether the IP address can be detected. Then click “ok”, and the system will prompt that PLC will be "STOP" mode. Click “YES” to start download. 291 291 292 - {{id name="IPIStudio.125C.PLCprotocols.WebHome40image-20221228143246-6.png"/}}[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_d43d2b7b2599ee64.png||alt="image-20221228143246-6.png" height="698" width="688"]]495 +[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_d43d2b7b2599ee64.png||alt="image-20221228143246-6.png" height="698" width="688"]] 293 293 294 294 **V-BOX Communication Settings** 295 295
- 1697099618537-157.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.AiXia - Size
-
... ... @@ -1,0 +1,1 @@ 1 +36.4 KB - Content
- xwiki_PIStudio_12.PLC+protocols_WebHome_664a826cd356c830.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.AiXia - Size
-
... ... @@ -1,0 +1,1 @@ 1 +82.1 KB - Content
- xwiki_PIStudio_12.PLC+protocols_WebHome_78026942a88f0fdb.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.AiXia - Size
-
... ... @@ -1,0 +1,1 @@ 1 +39.3 KB - Content
- xwiki_PIStudio_12.PLC+protocols_WebHome_872ec32d12b55aa.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.AiXia - Size
-
... ... @@ -1,0 +1,1 @@ 1 +133.4 KB - Content
- xwiki_PIStudio_12.PLC+protocols_WebHome_8ee8d3ac3637bfc4.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.AiXia - Size
-
... ... @@ -1,0 +1,1 @@ 1 +96.9 KB - Content
- xwiki_PIStudio_12.PLC+protocols_WebHome_ac8ece9a26719fda.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.AiXia - Size
-
... ... @@ -1,0 +1,1 @@ 1 +107.1 KB - Content
- 西门子1200协议参数.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.AiXia - Size
-
... ... @@ -1,0 +1,1 @@ 1 +64.6 KB - Content