From version 26.1
edited by Theodore Xu
on 2023/08/28 10:06
on 2023/08/28 10:06
Change comment:
There is no comment for this version
To version 46.1
edited by Theodore Xu
on 2023/10/12 17:06
on 2023/10/12 17:06
Change comment:
There is no comment for this version
Summary
-
Page properties (1 modified, 0 added, 0 removed)
-
Attachments (0 modified, 7 added, 0 removed)
- 1697099618537-157.png
- xwiki_PIStudio_12.PLC+protocols_WebHome_664a826cd356c830.png
- xwiki_PIStudio_12.PLC+protocols_WebHome_78026942a88f0fdb.png
- xwiki_PIStudio_12.PLC+protocols_WebHome_872ec32d12b55aa.png
- xwiki_PIStudio_12.PLC+protocols_WebHome_8ee8d3ac3637bfc4.png
- xwiki_PIStudio_12.PLC+protocols_WebHome_ac8ece9a26719fda.png
- 西门子1200协议参数.png
Details
- Page properties
-
- Content
-
... ... @@ -1,24 +3,37 @@ 1 -= **Siemens ** = 2 - 3 3 == **S7-200 Smart Serial** == 4 4 5 -** 1)AddressList3 +**V-BOX setting** 6 6 7 -|**Type**|**Device register**|**HMI register**|**Format**|**Range**|**Note** 8 -|(% rowspan="9" %)Bit|I|I|I ddddd.o|0.0~~99999.7| 9 -|Q|Q|Q ddddd.o|0.0~~99999.7| 10 -|V|VWbit|VWbit ddddd.o|0.0~~99999.7| 11 -|V|V|V ddddd.o|0.0~~99999.7| 12 -|M|M|M ddddd.o|0.0~~99999.7| 13 -|SM|SM|ddddd.o|0.0~~99999.7| 14 -|S|S|ddddd.o|0.0~~99999.7|Read only 15 -|T|T|ddddd|0~~99999|Timer state, read only 16 -|C|C|ddddd|0~~99999|Counter state, read only 17 -|(% rowspan="12" %)Word|I|IW|IW ddddd|0~~99999| 18 -|Q|QW|QW ddddd|0~~99999| 19 -|AI|AIW|AIW ddddd|0~~99999| 20 -|AQ|VB|VB ddddd|0~~99999| 21 -|V|VW|VW ddddd|0~~99998|((( 5 +(% style="width:1323.87px" %) 6 +|**Items**|**Settings**|**Note** 7 +|Protocol|(% style="width:783px" %)Siemens S7-200 CPU22x/Smart PPI| 8 +|Connection|(% style="width:783px" %)RS485| 9 +|Baud rate|(% style="width:783px" %)9600| 10 +|Data bit|(% style="width:783px" %)8| 11 +|Parity|(% style="width:783px" %)EVEN| 12 +|Stop bit|(% style="width:783px" %)1| 13 +|PLC station No.|(% style="width:783px" %)2| 14 + 15 +(% style="text-align:center" %) 16 +[[image:西门子200串口.png]] 17 + 18 +**Address List ** 19 + 20 +|**Type**|**Device register**|**Format**|**Range**|**Note** 21 +|(% rowspan="9" %)Bit|I|I ddddd.o|0.0~~99999.7| 22 +|Q|Q ddddd.o|0.0~~99999.7| 23 +|V|VWbit ddddd.o|0.0~~99999.7| 24 +|V|V ddddd.o|0.0~~99999.7| 25 +|M|M ddddd.o|0.0~~99999.7| 26 +|SM|ddddd.o|0.0~~99999.7| 27 +|S|ddddd.o|0.0~~99999.7|Read only 28 +|T|ddddd|0~~99999|Timer state, read only 29 +|C|ddddd|0~~99999|Counter state, read only 30 +|(% rowspan="12" %)Word|I|IW ddddd|0~~99999| 31 +|Q|QW ddddd|0~~99999| 32 +|AI|AIW ddddd|0~~99999| 33 +|AQ|VB ddddd|0~~99999| 34 +|V|VW ddddd|0~~99998|((( 22 22 VW0=VB (0~~1) 23 23 24 24 VW2=VB (2~~3) ... ... @@ -25,7 +25,7 @@ 25 25 26 26 Address value is a multiple of 2 27 27 ))) 28 -|V|VD |VDddddd|0~~99998|(((41 +|V|VD ddddd|0~~99998|((( 29 29 VD0=VB (0~~3) 30 30 31 31 VD2=VB (4~~7) ... ... @@ -32,8 +32,8 @@ 32 32 33 33 Address value is a multiple of 4 34 34 ))) 35 -|M|MB |MBddddd|0~~99999|36 -|M|MW |MWddddd|0~~99999|(((48 +|M|MB ddddd|0~~99999| 49 +|M|MW ddddd|0~~99999|((( 37 37 MW0=MB(0~~1) 38 38 39 39 MW2=MB(2~~3) ... ... @@ -40,7 +40,7 @@ 40 40 41 41 Address value is a multiple of 2 42 42 ))) 43 -|M|MD |MDddddd|0~~99999|(((56 +|M|MD ddddd|0~~99999|((( 44 44 MD0=MB(0~~3) 45 45 46 46 MD4=MB(4~~7) ... ... @@ -47,26 +47,19 @@ 47 47 48 48 Address value is a multiple of 4 49 49 ))) 50 -|T|TW |TWddddd|0~~99999|Value of timer51 -|C|CW |CWddddd|0~~99999|Value of counter52 -|W|SW |SWddddd|0~~99999|63 +|T|TW ddddd|0~~99999|Value of timer 64 +|C|CW ddddd|0~~99999|Value of counter 65 +|W|SW ddddd|0~~99999| 53 53 54 -** 2)V-BOXProtocol:Siemens S7-200 CPU22x/Smart PPI**67 +**PLC setting** 55 55 56 56 (% style="text-align:center" %) 57 -[[image:西门子200串口.png]] 58 - 59 -**3)PLC software** 60 - 61 -(% style="text-align:center" %) 62 62 [[image:西门子软件版本.png]] 63 63 64 -**4)PLC Software Configuration** 65 - 66 66 (% style="text-align:center" %) 67 67 [[image:485通讯配置.png]] 68 68 69 -** 5)Connect and Download**75 +**Connect and Download** 70 70 71 71 (% style="text-align:center" %) 72 72 [[image:以太网 PC和PLC连接.png]] ... ... @@ -74,7 +74,7 @@ 74 74 (% style="text-align:center" %) 75 75 [[image:以太网下载.png]] 76 76 77 -** 6)wiring**83 +**Cable Wiring** 78 78 79 79 (% style="text-align:center" %) 80 80 [[image:485接线.png]] ... ... @@ -81,32 +81,34 @@ 81 81 82 82 == **S7-200 Smart Ethernet ** == 83 83 84 -(% class="wikigeneratedid" id="H1FF09V-BOX" %) 85 -**1)V-BOX Protocol:Siemens S7-200 Smart(Ethernet)** 90 +**V-BOX setting** 86 86 92 +|**Items**|**Settings** 93 +|Protocol|Siemens S7-200 Smart(Ethernet) 94 +|Connection|Ethernet 95 +|Port No.|102 96 +|PLC station No.|2 97 + 87 87 (% style="text-align:center" %) 88 88 [[image:西门子200smart 以太网.png]] 89 89 90 -** 2)PLC software**101 +**PLC setting** 91 91 92 92 (% style="text-align:center" %) 93 93 [[image:西门子软件版本.png]] 94 94 95 -**3)PLC Software Configuration** 96 - 97 97 (% style="text-align:center" %) 98 98 [[image:以太网通讯配置.png]] 99 99 100 -** 4)Connect and Download**109 +**Connect and Download** 101 101 102 102 (% style="text-align:center" %) 103 103 [[image:以太网 PC和PLC连接.png]] 104 104 105 - 106 106 (% style="text-align:center" %) 107 107 [[image:以太网下载.png]] 108 108 109 -** 5)wiring**117 +**Cable Wiring** 110 110 111 111 V-Box : RJ45 Ethernet interface 112 112 ... ... @@ -115,11 +115,11 @@ 115 115 (% style="text-align:center" %) 116 116 [[image:以太网连接.png]] 117 117 118 -== {{id name="HS7-300Ethernet"/}}**S7-300 Ethernet ** ==126 +== **S7-300 Ethernet ** == 119 119 120 120 Supported Series: Siemens S7-300 series PLC 121 121 122 -** 1)V-BOX setting**130 +**V-BOX setting** 123 123 124 124 |**Items**|**Settings**|**Note** 125 125 |Protocol|Simens S7-300 Ethernet| ... ... @@ -127,21 +127,21 @@ 127 127 |Port No.|102| 128 128 |PLC station No.|2|Need to be same as the PLC setting 129 129 130 -** 2)Address List**138 +**Address List** 131 131 132 -|**Type**|**Device register**|** HMI register**|**Format**|**Range**|**Note**133 -|(% rowspan="4" %)Bit|I|I |Iddddd.o|0.0~~99999.7|134 -|Q|Q |Qddddd.o|0.0~~99999.7|135 -|M|M |Mddddd.o|0.0~~99999.7|136 -|DB0.DB~~DB99.DB|DBxDB D|DBxDBnndddd.o|0.0~~99999999.7|(((140 +|**Type**|**Device register**|**Format**|**Range**|**Note** 141 +|(% rowspan="4" %)Bit|I|I ddddd.o|0.0~~99999.7| 142 +|Q|Q ddddd.o|0.0~~99999.7| 143 +|M|M ddddd.o|0.0~~99999.7| 144 +|DB0.DB~~DB99.DB|DBxDB nndddd.o|0.0~~99999999.7|((( 137 137 nn: block number; 138 138 139 139 dddd: address; 140 140 ))) 141 -|(% rowspan="8" %)Word|I|IW |IWddddd|0~~99999|142 -|Q|QW |QWddddd|0~~99999|143 -|(% rowspan="3" %)M|MB |MBddddd|0~~99999|144 -|MW |MWddddd|0~~99999|(((149 +|(% rowspan="8" %)Word|I|IW ddddd|0~~99999| 150 +|Q|QW ddddd|0~~99999| 151 +|(% rowspan="3" %)M|MB ddddd|0~~99999| 152 +|MW ddddd|0~~99999|((( 145 145 MW0=MB(0~~1) 146 146 147 147 MW2=MB(2~~3) ... ... @@ -148,7 +148,7 @@ 148 148 149 149 Address value is a multiple of 2 150 150 ))) 151 -|MD |MDddddd|0~~99999|(((159 +|MD ddddd|0~~99999|((( 152 152 MD0=MB(0~~3) 153 153 154 154 MD4=MB(4~~7) ... ... @@ -155,49 +155,39 @@ 155 155 156 156 Address value is a multiple of 4 157 157 ))) 158 -|(% rowspan="3" %)DB0.DB~~DB99.DB|DBxDBB |DBxDBBnndddd|0~~99999999|(% rowspan="3" %)(((166 +|(% rowspan="3" %)DB0.DB~~DB99.DB|DBxDBB nndddd|0~~99999999|(% rowspan="3" %)((( 159 159 nn: block number; 160 160 161 161 dddd: address 162 162 ))) 163 -|DBxDBW |DBxDBWnndddd|0~~99999999164 -|DBxDBD |DBxDBDnndddd|0~~99999999171 +|DBxDBW nndddd|0~~99999999 172 +|DBxDBD nndddd|0~~99999999 165 165 166 -** 3)Configure the communication protocol**174 +**Configure the communication protocol** 167 167 168 - {{id name="Iimage-20220824161345-1.png"/}}[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_8e00ed9483ddb629.png||alt="image-20220824161345-1.png" height="1011" width="1920"]]176 +[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_8e00ed9483ddb629.png||alt="image-20220824161345-1.png" height="1011" width="1920"]] 169 169 170 -** 4)Cable Wiring**178 +**Cable Wiring** 171 171 172 - {{id name="Iimage-20220824161450-2.png"/}}[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_ac8ece9a26719fda.png||alt="image-20220824161450-2.png" height="170" width="401"]]180 +[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_ac8ece9a26719fda.png||alt="image-20220824161450-2.png" height="170" width="401"]] 173 173 174 -== {{id name="HS7-1200A0Ethernet"/}}**S7-1200 Ethernet ** ==182 +== **S7-1200 Ethernet ** == 175 175 176 176 [[download link>>url:https://ftp.we-con.com.cn/Download/WIKI/V-BOX/Demo/%E9%80%9A%E8%AE%AF%E6%A1%88%E4%BE%8B/Communicate%20with%20S7-1200%20via%20Ehernet.zip]] 177 177 178 - ==**S7-XXXEthernet**==186 +**V-BOX Setting** 179 179 180 -Supported Series: Siemens S7-400, S7-1200 and S7-1500 181 - 182 -**1)V-BOX setting** 183 - 184 -|=**Items**|=**Settings**|=**Note** 185 -|Protocol|Siemens S7-XXX| 188 +|**Items**|**Settings**|**Note** 189 +|Protocol|Siemens S7-1200| 186 186 |Connection|Ethernet| 187 187 |Port No.|102| 188 -|Device No.|Slot (Default 1 for S7-1500/ 2 for S7-1200/ 3 for S7-400)| 189 -|HMI No.|Rack (Default as 0)| 192 +|PLC station No.|2| 190 190 191 -Slot from TIA Portal is equal to Device No. of V-net 194 +(% style="text-align:center" %) 195 +[[image:西门子1200协议参数.png]] 192 192 193 - Rack from TIAPortalisequalto HMI No. of V-net197 +**Address List** 194 194 195 -{{id name="Iimage-20220824162459-3.png"/}}[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_d78bc267e5fc6394.png||alt="image-20220824162459-3.png" height="503" width="798"]] 196 - 197 -{{id name="Iimage-20220824163305-2.png"/}}[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_c9ae84ef5d418580.png||alt="image-20220824163305-2.png" height="1009" width="1920"]] 198 - 199 -**2)Address List** 200 - 201 201 |**Type**|**Device register**|**HMI register**|**Format**|**Range**|**Note** 202 202 |(% rowspan="4" %)Bit|I|I|M d.o|((( 203 203 d:0~-~-9999 ... ... @@ -276,18 +276,176 @@ 276 276 Address value is a multiple of 4 277 277 ))) 278 278 279 -**3)Configure the communication protocol** 277 +{{info}} 278 +✎Note: 280 280 281 -{{id name="Iimage-20220824163448-3.png"/}}[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_9e740a8bf83ea3bf.png||alt="image-20220824163448-3.png" height="557" width="974"]] 280 +* The S7-1200 supports simultaneous connection of three devices. 281 +* V-BOX access PLC, use S7 protocol, access PLC TSAP 02.01 (S7-1200 PROFINET interface only supports three connections, the default support), detailed reference to the system manual of S7-1200. 282 +* S7-1200 String type, the default first two bytes are used to store the maximum character and valid characters, so the text data will be shifted back one word address. When interacting with the data, what way this address plc is displayed with is unknown. And because of an extra word of data causes us to display the wrong. The solution is if we use String, then the actual data address we want to operate on is actually shifted back two bytes, so as long as the address on the project is shifted back 2 bits to correspond with the actual data address. 283 +* V-BOX operation character length needs to be set to 2 times the length of the Siemens character for proper display 284 +{{/info}} 282 282 286 +**PLC Settings** 287 + 288 +Add BD 289 + 290 +* Please uncheck [Symbolic access only] option; 291 + 292 +(% style="text-align:center" %) 293 +[[image:xwiki_PIStudio_12.PLC+protocols_WebHome_872ec32d12b55aa.png]] 294 + 295 +Address settings, using BD2 as example. 296 + 297 +* DB×DBB2xxxx, DB×DBW2xxxx, DB×DBD2xxxx for accessing data of DB2 in B1. 298 +* 2 represent DB block number 299 +* xxxx represent address 300 + 301 +**Such as:** 302 + 303 +* DBxDBB20000 = DB2.DBB0 304 +* DBxDBW20004 = DB2.DBW4 305 + 306 +(% style="text-align:center" %) 307 +[[image:xwiki_PIStudio_12.PLC+protocols_WebHome_8ee8d3ac3637bfc4.png]] 308 + 309 +**How to connect with S7-1200 Firmware V4.0** 310 + 311 +PLC configuration 312 + 313 +* Double click [device configuration] in Siemens via software 314 +* Double click [protection] to enter protection configuration screen 315 + 316 +(% style="text-align:center" %) 317 +[[image:xwiki_PIStudio_12.PLC+protocols_WebHome_664a826cd356c830.png]] 318 + 319 +* Check [Permit access with PUT / GET communication from remote partner (PLC, HMI, OPC, ...)] 320 + 321 +(% style="text-align:center" %) 322 +[[image:xwiki_PIStudio_12.PLC+protocols_WebHome_78026942a88f0fdb.png]] 323 + 324 +DB settings 325 + 326 +* Right click [DB], select [properties] 327 +* Uncheck [optimized block access] 328 + 329 +**Cable Wiring** 330 + 331 +(% style="text-align:center" %) 332 +[[image:xwiki_PIStudio_12.PLC+protocols_WebHome_ac8ece9a26719fda.png]] 333 + 334 +== **S7-XXX Ethernet** == 335 + 336 +Supported Series: Siemens S7-400, S7-1200 and S7-1500 337 + 338 +**V-BOX setting** 339 + 340 +|=**Items**|=**Settings**|=**Note** 341 +|Protocol|Siemens S7-XXX| 342 +|Connection|Ethernet| 343 +|Port No.|102| 344 +|Device No.|Slot (Default 1 for S7-1500/ 2 for S7-1200/ 3 for S7-400)| 345 +|HMI No.|Rack (Default as 0)| 346 + 347 +Slot from TIA Portal is equal to Device No. of V-net 348 + 349 +Rack from TIA Portal is equal to HMI No. of V-net 350 + 351 +[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_d78bc267e5fc6394.png||alt="image-20220824162459-3.png" height="503" width="798"]] 352 + 353 +[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_c9ae84ef5d418580.png||alt="image-20220824163305-2.png" height="1009" width="1920"]] 354 + 355 +**Address List** 356 + 357 +|**Type**|**Device register**|**Format**|**Range**|**Note** 358 +|(% rowspan="4" %)Bit|I|M d.o|((( 359 +d:0~-~-9999 360 + 361 +o:0-7 362 +)))| 363 +|Q|Q d.o|((( 364 +d:0~-~-9999 365 + 366 +o:0-7 367 +)))| 368 +|M|M d.o|((( 369 +d:0~-~-9999 370 + 371 +o:0-7 372 +)))| 373 +|DB0.DB-DB99.DB|DBxDBnndddd.o|((( 374 +nn:0-9999, 375 + 376 +dddd:0-9999, 377 + 378 +o:0-7 379 +)))|((( 380 +nn:DB No. 381 + 382 +dddd:address value 383 + 384 +o: digit address 385 +))) 386 +|(% rowspan="8" %)Word|M|MB d|d:0-99999| 387 +|M|MW d|d:0-99999|((( 388 +MW0=MB(0~~1) 389 + 390 +MW2=MB(2~~3) 391 + 392 +Address value is a multiple of 2 393 +))) 394 +|M|MD d|d:0-99999|((( 395 +MD0=MB(0~~3) 396 + 397 +MD4=MB(4~~7) 398 + 399 +Address value is a multiple of 4 400 +))) 401 +|I|IW d|d:0-99999| 402 +|Q|QW d|d:0-99999| 403 +|DB0.DB-DB99.DB|DBxDBBnndddd|((( 404 +nn:0-9999 405 + 406 +dddd:0-9999 407 +)))|((( 408 +nn:DB No. 409 + 410 +dddd:address value 411 +))) 412 +|DB0.DB-DB99.DB|DBxDBWnndddd|((( 413 +nn:0-9999 414 + 415 +dddd:0-9999 416 +)))|((( 417 +nn:DB No. 418 + 419 +dddd:address value 420 + 421 +Address value is a multiple of 2 422 +))) 423 +|DB0.DB-DB99.DB|DBxDBDnndddd|((( 424 +nn:0-9999 425 + 426 +dddd:0-9999 427 +)))|((( 428 +nn:DB No. 429 + 430 +dddd:address value 431 + 432 +Address value is a multiple of 4 433 +))) 434 + 435 +**Configure the communication protocol** 436 + 437 +[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_9e740a8bf83ea3bf.png||alt="image-20220824163448-3.png" height="557" width="974"]] 438 + 283 283 **✎Note:** 284 284 285 285 * The S7-1200 supports simultaneous connection of three devices, so the driver supports simultaneous access to PLC by three V-BOX. 286 286 * V-BOX access PLC, use S7 protocol, access PLC TSAP 02.01 (s7-1200 PROFINET interface only supports three connections, the default support), detailed reference to the system manual of S7-1200. 287 287 288 -** 4)Cable Wiring**444 +**Cable Wiring** 289 289 290 - {{id name="Iimage-20220824162342-2.png"/}}[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_ac8ece9a26719fda.png||alt="image-20220824162342-2.png" height="170" width="401"]]446 +[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_ac8ece9a26719fda.png||alt="image-20220824162342-2.png" height="170" width="401"]] 291 291 292 292 == {{id name="HLOGOEthernet"/}}**LOGO Ethernet ** == 293 293 ... ... @@ -324,19 +324,19 @@ 324 324 325 325 Click [Tools]~-~-[Ethernet Connections],shown as below. 326 326 327 - {{id name="IPIStudio.125C.PLCprotocols.WebHome4012.PLCProtocol_html_8b9d2322edf89519.png"/}}[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_d13df637bfedcc52.png||alt="12.PLC Protocol_html_8b9d2322edf89519.png" height="641" width="423"]]483 +[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_d13df637bfedcc52.png||alt="12.PLC Protocol_html_8b9d2322edf89519.png" height="641" width="423"]] 328 328 329 329 Set Ethernet connection parameter. IP, Subnet Mask, shown as below. 330 330 331 - {{id name="IPIStudio.125C.PLCprotocols.WebHome40image-20221228142937-4.png"/}}[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_316247e0130c4c55.png||alt="image-20221228142937-4.png" height="484" width="366"]]487 +[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_316247e0130c4c55.png||alt="image-20221228142937-4.png" height="484" width="366"]] 332 332 333 333 **TSAP set**:The value set by local TSAP is the remote TSAP set in HMI. PLC's remote TSAP is the opposite,shown as below. 334 334 335 - {{id name="IPIStudio.125C.PLCprotocols.WebHome40image-20221228143047-5.png"/}}[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_facc6ee1af05162f.png||alt="image-20221228143047-5.png" height="626" width="1088"]]491 +[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_facc6ee1af05162f.png||alt="image-20221228143047-5.png" height="626" width="1088"]] 336 336 337 337 **Download Project**: Click "Address book" to add the IP address to be downloaded (fi."Detect" to check whether the IP address can be detected. Then click “ok”, and the system will prompt that PLC will be "STOP" mode. Click “YES” to start download. 338 338 339 - {{id name="IPIStudio.125C.PLCprotocols.WebHome40image-20221228143246-6.png"/}}[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_d43d2b7b2599ee64.png||alt="image-20221228143246-6.png" height="698" width="688"]]495 +[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_d43d2b7b2599ee64.png||alt="image-20221228143246-6.png" height="698" width="688"]] 340 340 341 341 **V-BOX Communication Settings** 342 342
- 1697099618537-157.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.AiXia - Size
-
... ... @@ -1,0 +1,1 @@ 1 +36.4 KB - Content
- xwiki_PIStudio_12.PLC+protocols_WebHome_664a826cd356c830.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.AiXia - Size
-
... ... @@ -1,0 +1,1 @@ 1 +82.1 KB - Content
- xwiki_PIStudio_12.PLC+protocols_WebHome_78026942a88f0fdb.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.AiXia - Size
-
... ... @@ -1,0 +1,1 @@ 1 +39.3 KB - Content
- xwiki_PIStudio_12.PLC+protocols_WebHome_872ec32d12b55aa.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.AiXia - Size
-
... ... @@ -1,0 +1,1 @@ 1 +133.4 KB - Content
- xwiki_PIStudio_12.PLC+protocols_WebHome_8ee8d3ac3637bfc4.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.AiXia - Size
-
... ... @@ -1,0 +1,1 @@ 1 +96.9 KB - Content
- xwiki_PIStudio_12.PLC+protocols_WebHome_ac8ece9a26719fda.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.AiXia - Size
-
... ... @@ -1,0 +1,1 @@ 1 +107.1 KB - Content
- 西门子1200协议参数.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.AiXia - Size
-
... ... @@ -1,0 +1,1 @@ 1 +64.6 KB - Content