From version 29.1
edited by Theodore Xu
on 2023/08/28 10:10
on 2023/08/28 10:10
Change comment:
There is no comment for this version
To version 46.1
edited by Theodore Xu
on 2023/10/12 17:06
on 2023/10/12 17:06
Change comment:
There is no comment for this version
Summary
-
Page properties (1 modified, 0 added, 0 removed)
-
Attachments (0 modified, 7 added, 0 removed)
- 1697099618537-157.png
- xwiki_PIStudio_12.PLC+protocols_WebHome_664a826cd356c830.png
- xwiki_PIStudio_12.PLC+protocols_WebHome_78026942a88f0fdb.png
- xwiki_PIStudio_12.PLC+protocols_WebHome_872ec32d12b55aa.png
- xwiki_PIStudio_12.PLC+protocols_WebHome_8ee8d3ac3637bfc4.png
- xwiki_PIStudio_12.PLC+protocols_WebHome_ac8ece9a26719fda.png
- 西门子1200协议参数.png
Details
- Page properties
-
- Content
-
... ... @@ -1,39 +3,37 @@ 1 -= **Siemens ** = 2 - 3 3 == **S7-200 Smart Serial** == 4 4 3 +**V-BOX setting** 5 5 6 -**1)V-BOX setting** 5 +(% style="width:1323.87px" %) 6 +|**Items**|**Settings**|**Note** 7 +|Protocol|(% style="width:783px" %)Siemens S7-200 CPU22x/Smart PPI| 8 +|Connection|(% style="width:783px" %)RS485| 9 +|Baud rate|(% style="width:783px" %)9600| 10 +|Data bit|(% style="width:783px" %)8| 11 +|Parity|(% style="width:783px" %)EVEN| 12 +|Stop bit|(% style="width:783px" %)1| 13 +|PLC station No.|(% style="width:783px" %)2| 7 7 8 -|**Item**|**Settings**|**Note** 9 -|Protocol|Siemens S7-200 CPU22x/Smart PPI| 10 -|Connection|RS485| 11 -|Baud rate|9600| 12 -|Data bit|8| 13 -|Parity|EVEN| 14 -|Stop bit|1| 15 -|PLC station No.|2 16 - 17 17 (% style="text-align:center" %) 18 18 [[image:西门子200串口.png]] 19 19 20 -** 2)Address List **18 +**Address List ** 21 21 22 -|**Type**|**Device register**|** HMI register**|**Format**|**Range**|**Note**23 -|(% rowspan="9" %)Bit|I|I |Iddddd.o|0.0~~99999.7|24 -|Q|Q |Qddddd.o|0.0~~99999.7|25 -|V|VWbit |VWbitddddd.o|0.0~~99999.7|26 -|V|V |Vddddd.o|0.0~~99999.7|27 -|M|M |Mddddd.o|0.0~~99999.7|28 -|SM| SM|ddddd.o|0.0~~99999.7|29 -|S| S|ddddd.o|0.0~~99999.7|Read only30 -|T| T|ddddd|0~~99999|Timer state, read only31 -|C| C|ddddd|0~~99999|Counter state, read only32 -|(% rowspan="12" %)Word|I|IW |IWddddd|0~~99999|33 -|Q|QW |QWddddd|0~~99999|34 -|AI|AIW |AIWddddd|0~~99999|35 -|AQ|VB |VBddddd|0~~99999|36 -|V|VW |VWddddd|0~~99998|(((20 +|**Type**|**Device register**|**Format**|**Range**|**Note** 21 +|(% rowspan="9" %)Bit|I|I ddddd.o|0.0~~99999.7| 22 +|Q|Q ddddd.o|0.0~~99999.7| 23 +|V|VWbit ddddd.o|0.0~~99999.7| 24 +|V|V ddddd.o|0.0~~99999.7| 25 +|M|M ddddd.o|0.0~~99999.7| 26 +|SM|ddddd.o|0.0~~99999.7| 27 +|S|ddddd.o|0.0~~99999.7|Read only 28 +|T|ddddd|0~~99999|Timer state, read only 29 +|C|ddddd|0~~99999|Counter state, read only 30 +|(% rowspan="12" %)Word|I|IW ddddd|0~~99999| 31 +|Q|QW ddddd|0~~99999| 32 +|AI|AIW ddddd|0~~99999| 33 +|AQ|VB ddddd|0~~99999| 34 +|V|VW ddddd|0~~99998|((( 37 37 VW0=VB (0~~1) 38 38 39 39 VW2=VB (2~~3) ... ... @@ -40,7 +40,7 @@ 40 40 41 41 Address value is a multiple of 2 42 42 ))) 43 -|V|VD |VDddddd|0~~99998|(((41 +|V|VD ddddd|0~~99998|((( 44 44 VD0=VB (0~~3) 45 45 46 46 VD2=VB (4~~7) ... ... @@ -47,8 +47,8 @@ 47 47 48 48 Address value is a multiple of 4 49 49 ))) 50 -|M|MB |MBddddd|0~~99999|51 -|M|MW |MWddddd|0~~99999|(((48 +|M|MB ddddd|0~~99999| 49 +|M|MW ddddd|0~~99999|((( 52 52 MW0=MB(0~~1) 53 53 54 54 MW2=MB(2~~3) ... ... @@ -55,7 +55,7 @@ 55 55 56 56 Address value is a multiple of 2 57 57 ))) 58 -|M|MD |MDddddd|0~~99999|(((56 +|M|MD ddddd|0~~99999|((( 59 59 MD0=MB(0~~3) 60 60 61 61 MD4=MB(4~~7) ... ... @@ -62,21 +62,19 @@ 62 62 63 63 Address value is a multiple of 4 64 64 ))) 65 -|T|TW |TWddddd|0~~99999|Value of timer66 -|C|CW |CWddddd|0~~99999|Value of counter67 -|W|SW |SWddddd|0~~99999|63 +|T|TW ddddd|0~~99999|Value of timer 64 +|C|CW ddddd|0~~99999|Value of counter 65 +|W|SW ddddd|0~~99999| 68 68 69 -** 3)PLC software**67 +**PLC setting** 70 70 71 71 (% style="text-align:center" %) 72 72 [[image:西门子软件版本.png]] 73 73 74 -**4)PLC Software Configuration** 75 - 76 76 (% style="text-align:center" %) 77 77 [[image:485通讯配置.png]] 78 78 79 -** 5)Connect and Download**75 +**Connect and Download** 80 80 81 81 (% style="text-align:center" %) 82 82 [[image:以太网 PC和PLC连接.png]] ... ... @@ -84,7 +84,7 @@ 84 84 (% style="text-align:center" %) 85 85 [[image:以太网下载.png]] 86 86 87 -** 6)wiring**83 +**Cable Wiring** 88 88 89 89 (% style="text-align:center" %) 90 90 [[image:485接线.png]] ... ... @@ -91,38 +91,34 @@ 91 91 92 92 == **S7-200 Smart Ethernet ** == 93 93 94 -** 1)V-BOXSetting**90 +**V-BOX setting** 95 95 92 +|**Items**|**Settings** 93 +|Protocol|Siemens S7-200 Smart(Ethernet) 94 +|Connection|Ethernet 95 +|Port No.|102 96 +|PLC station No.|2 96 96 97 -|**Items**|**Settings**|**Note** 98 -|Protocol|Siemens S7-200 Smart(Ethernet)| 99 -|Connection|Ethernet| 100 -|Port No.|102| 101 -|PLC station No.|2| 102 - 103 103 (% style="text-align:center" %) 104 104 [[image:西门子200smart 以太网.png]] 105 105 106 -** 2)PLC software**101 +**PLC setting** 107 107 108 108 (% style="text-align:center" %) 109 109 [[image:西门子软件版本.png]] 110 110 111 -**3)PLC Software Configuration** 112 - 113 113 (% style="text-align:center" %) 114 114 [[image:以太网通讯配置.png]] 115 115 116 -** 4)Connect and Download**109 +**Connect and Download** 117 117 118 118 (% style="text-align:center" %) 119 119 [[image:以太网 PC和PLC连接.png]] 120 120 121 - 122 122 (% style="text-align:center" %) 123 123 [[image:以太网下载.png]] 124 124 125 -** 5)wiring**117 +**Cable Wiring** 126 126 127 127 V-Box : RJ45 Ethernet interface 128 128 ... ... @@ -131,11 +131,11 @@ 131 131 (% style="text-align:center" %) 132 132 [[image:以太网连接.png]] 133 133 134 -== {{id name="HS7-300Ethernet"/}}**S7-300 Ethernet ** ==126 +== **S7-300 Ethernet ** == 135 135 136 136 Supported Series: Siemens S7-300 series PLC 137 137 138 -** 1)V-BOX setting**130 +**V-BOX setting** 139 139 140 140 |**Items**|**Settings**|**Note** 141 141 |Protocol|Simens S7-300 Ethernet| ... ... @@ -143,21 +143,21 @@ 143 143 |Port No.|102| 144 144 |PLC station No.|2|Need to be same as the PLC setting 145 145 146 -** 2)Address List**138 +**Address List** 147 147 148 -|**Type**|**Device register**|** HMI register**|**Format**|**Range**|**Note**149 -|(% rowspan="4" %)Bit|I|I |Iddddd.o|0.0~~99999.7|150 -|Q|Q |Qddddd.o|0.0~~99999.7|151 -|M|M |Mddddd.o|0.0~~99999.7|152 -|DB0.DB~~DB99.DB|DBxDB D|DBxDBnndddd.o|0.0~~99999999.7|(((140 +|**Type**|**Device register**|**Format**|**Range**|**Note** 141 +|(% rowspan="4" %)Bit|I|I ddddd.o|0.0~~99999.7| 142 +|Q|Q ddddd.o|0.0~~99999.7| 143 +|M|M ddddd.o|0.0~~99999.7| 144 +|DB0.DB~~DB99.DB|DBxDB nndddd.o|0.0~~99999999.7|((( 153 153 nn: block number; 154 154 155 155 dddd: address; 156 156 ))) 157 -|(% rowspan="8" %)Word|I|IW |IWddddd|0~~99999|158 -|Q|QW |QWddddd|0~~99999|159 -|(% rowspan="3" %)M|MB |MBddddd|0~~99999|160 -|MW |MWddddd|0~~99999|(((149 +|(% rowspan="8" %)Word|I|IW ddddd|0~~99999| 150 +|Q|QW ddddd|0~~99999| 151 +|(% rowspan="3" %)M|MB ddddd|0~~99999| 152 +|MW ddddd|0~~99999|((( 161 161 MW0=MB(0~~1) 162 162 163 163 MW2=MB(2~~3) ... ... @@ -164,7 +164,7 @@ 164 164 165 165 Address value is a multiple of 2 166 166 ))) 167 -|MD |MDddddd|0~~99999|(((159 +|MD ddddd|0~~99999|((( 168 168 MD0=MB(0~~3) 169 169 170 170 MD4=MB(4~~7) ... ... @@ -171,49 +171,39 @@ 171 171 172 172 Address value is a multiple of 4 173 173 ))) 174 -|(% rowspan="3" %)DB0.DB~~DB99.DB|DBxDBB |DBxDBBnndddd|0~~99999999|(% rowspan="3" %)(((166 +|(% rowspan="3" %)DB0.DB~~DB99.DB|DBxDBB nndddd|0~~99999999|(% rowspan="3" %)((( 175 175 nn: block number; 176 176 177 177 dddd: address 178 178 ))) 179 -|DBxDBW |DBxDBWnndddd|0~~99999999180 -|DBxDBD |DBxDBDnndddd|0~~99999999171 +|DBxDBW nndddd|0~~99999999 172 +|DBxDBD nndddd|0~~99999999 181 181 182 -** 3)Configure the communication protocol**174 +**Configure the communication protocol** 183 183 184 - {{id name="Iimage-20220824161345-1.png"/}}[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_8e00ed9483ddb629.png||alt="image-20220824161345-1.png" height="1011" width="1920"]]176 +[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_8e00ed9483ddb629.png||alt="image-20220824161345-1.png" height="1011" width="1920"]] 185 185 186 -** 4)Cable Wiring**178 +**Cable Wiring** 187 187 188 - {{id name="Iimage-20220824161450-2.png"/}}[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_ac8ece9a26719fda.png||alt="image-20220824161450-2.png" height="170" width="401"]]180 +[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_ac8ece9a26719fda.png||alt="image-20220824161450-2.png" height="170" width="401"]] 189 189 190 -== {{id name="HS7-1200A0Ethernet"/}}**S7-1200 Ethernet ** ==182 +== **S7-1200 Ethernet ** == 191 191 192 192 [[download link>>url:https://ftp.we-con.com.cn/Download/WIKI/V-BOX/Demo/%E9%80%9A%E8%AE%AF%E6%A1%88%E4%BE%8B/Communicate%20with%20S7-1200%20via%20Ehernet.zip]] 193 193 194 - ==**S7-XXXEthernet**==186 +**V-BOX Setting** 195 195 196 -Supported Series: Siemens S7-400, S7-1200 and S7-1500 197 - 198 -**1)V-BOX setting** 199 - 200 -|=**Items**|=**Settings**|=**Note** 201 -|Protocol|Siemens S7-XXX| 188 +|**Items**|**Settings**|**Note** 189 +|Protocol|Siemens S7-1200| 202 202 |Connection|Ethernet| 203 203 |Port No.|102| 204 -|Device No.|Slot (Default 1 for S7-1500/ 2 for S7-1200/ 3 for S7-400)| 205 -|HMI No.|Rack (Default as 0)| 192 +|PLC station No.|2| 206 206 207 -Slot from TIA Portal is equal to Device No. of V-net 194 +(% style="text-align:center" %) 195 +[[image:西门子1200协议参数.png]] 208 208 209 - Rack from TIAPortalisequalto HMI No. of V-net197 +**Address List** 210 210 211 -{{id name="Iimage-20220824162459-3.png"/}}[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_d78bc267e5fc6394.png||alt="image-20220824162459-3.png" height="503" width="798"]] 212 - 213 -{{id name="Iimage-20220824163305-2.png"/}}[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_c9ae84ef5d418580.png||alt="image-20220824163305-2.png" height="1009" width="1920"]] 214 - 215 -**2)Address List** 216 - 217 217 |**Type**|**Device register**|**HMI register**|**Format**|**Range**|**Note** 218 218 |(% rowspan="4" %)Bit|I|I|M d.o|((( 219 219 d:0~-~-9999 ... ... @@ -292,18 +292,176 @@ 292 292 Address value is a multiple of 4 293 293 ))) 294 294 295 -**3)Configure the communication protocol** 277 +{{info}} 278 +✎Note: 296 296 297 -{{id name="Iimage-20220824163448-3.png"/}}[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_9e740a8bf83ea3bf.png||alt="image-20220824163448-3.png" height="557" width="974"]] 280 +* The S7-1200 supports simultaneous connection of three devices. 281 +* V-BOX access PLC, use S7 protocol, access PLC TSAP 02.01 (S7-1200 PROFINET interface only supports three connections, the default support), detailed reference to the system manual of S7-1200. 282 +* S7-1200 String type, the default first two bytes are used to store the maximum character and valid characters, so the text data will be shifted back one word address. When interacting with the data, what way this address plc is displayed with is unknown. And because of an extra word of data causes us to display the wrong. The solution is if we use String, then the actual data address we want to operate on is actually shifted back two bytes, so as long as the address on the project is shifted back 2 bits to correspond with the actual data address. 283 +* V-BOX operation character length needs to be set to 2 times the length of the Siemens character for proper display 284 +{{/info}} 298 298 286 +**PLC Settings** 287 + 288 +Add BD 289 + 290 +* Please uncheck [Symbolic access only] option; 291 + 292 +(% style="text-align:center" %) 293 +[[image:xwiki_PIStudio_12.PLC+protocols_WebHome_872ec32d12b55aa.png]] 294 + 295 +Address settings, using BD2 as example. 296 + 297 +* DB×DBB2xxxx, DB×DBW2xxxx, DB×DBD2xxxx for accessing data of DB2 in B1. 298 +* 2 represent DB block number 299 +* xxxx represent address 300 + 301 +**Such as:** 302 + 303 +* DBxDBB20000 = DB2.DBB0 304 +* DBxDBW20004 = DB2.DBW4 305 + 306 +(% style="text-align:center" %) 307 +[[image:xwiki_PIStudio_12.PLC+protocols_WebHome_8ee8d3ac3637bfc4.png]] 308 + 309 +**How to connect with S7-1200 Firmware V4.0** 310 + 311 +PLC configuration 312 + 313 +* Double click [device configuration] in Siemens via software 314 +* Double click [protection] to enter protection configuration screen 315 + 316 +(% style="text-align:center" %) 317 +[[image:xwiki_PIStudio_12.PLC+protocols_WebHome_664a826cd356c830.png]] 318 + 319 +* Check [Permit access with PUT / GET communication from remote partner (PLC, HMI, OPC, ...)] 320 + 321 +(% style="text-align:center" %) 322 +[[image:xwiki_PIStudio_12.PLC+protocols_WebHome_78026942a88f0fdb.png]] 323 + 324 +DB settings 325 + 326 +* Right click [DB], select [properties] 327 +* Uncheck [optimized block access] 328 + 329 +**Cable Wiring** 330 + 331 +(% style="text-align:center" %) 332 +[[image:xwiki_PIStudio_12.PLC+protocols_WebHome_ac8ece9a26719fda.png]] 333 + 334 +== **S7-XXX Ethernet** == 335 + 336 +Supported Series: Siemens S7-400, S7-1200 and S7-1500 337 + 338 +**V-BOX setting** 339 + 340 +|=**Items**|=**Settings**|=**Note** 341 +|Protocol|Siemens S7-XXX| 342 +|Connection|Ethernet| 343 +|Port No.|102| 344 +|Device No.|Slot (Default 1 for S7-1500/ 2 for S7-1200/ 3 for S7-400)| 345 +|HMI No.|Rack (Default as 0)| 346 + 347 +Slot from TIA Portal is equal to Device No. of V-net 348 + 349 +Rack from TIA Portal is equal to HMI No. of V-net 350 + 351 +[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_d78bc267e5fc6394.png||alt="image-20220824162459-3.png" height="503" width="798"]] 352 + 353 +[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_c9ae84ef5d418580.png||alt="image-20220824163305-2.png" height="1009" width="1920"]] 354 + 355 +**Address List** 356 + 357 +|**Type**|**Device register**|**Format**|**Range**|**Note** 358 +|(% rowspan="4" %)Bit|I|M d.o|((( 359 +d:0~-~-9999 360 + 361 +o:0-7 362 +)))| 363 +|Q|Q d.o|((( 364 +d:0~-~-9999 365 + 366 +o:0-7 367 +)))| 368 +|M|M d.o|((( 369 +d:0~-~-9999 370 + 371 +o:0-7 372 +)))| 373 +|DB0.DB-DB99.DB|DBxDBnndddd.o|((( 374 +nn:0-9999, 375 + 376 +dddd:0-9999, 377 + 378 +o:0-7 379 +)))|((( 380 +nn:DB No. 381 + 382 +dddd:address value 383 + 384 +o: digit address 385 +))) 386 +|(% rowspan="8" %)Word|M|MB d|d:0-99999| 387 +|M|MW d|d:0-99999|((( 388 +MW0=MB(0~~1) 389 + 390 +MW2=MB(2~~3) 391 + 392 +Address value is a multiple of 2 393 +))) 394 +|M|MD d|d:0-99999|((( 395 +MD0=MB(0~~3) 396 + 397 +MD4=MB(4~~7) 398 + 399 +Address value is a multiple of 4 400 +))) 401 +|I|IW d|d:0-99999| 402 +|Q|QW d|d:0-99999| 403 +|DB0.DB-DB99.DB|DBxDBBnndddd|((( 404 +nn:0-9999 405 + 406 +dddd:0-9999 407 +)))|((( 408 +nn:DB No. 409 + 410 +dddd:address value 411 +))) 412 +|DB0.DB-DB99.DB|DBxDBWnndddd|((( 413 +nn:0-9999 414 + 415 +dddd:0-9999 416 +)))|((( 417 +nn:DB No. 418 + 419 +dddd:address value 420 + 421 +Address value is a multiple of 2 422 +))) 423 +|DB0.DB-DB99.DB|DBxDBDnndddd|((( 424 +nn:0-9999 425 + 426 +dddd:0-9999 427 +)))|((( 428 +nn:DB No. 429 + 430 +dddd:address value 431 + 432 +Address value is a multiple of 4 433 +))) 434 + 435 +**Configure the communication protocol** 436 + 437 +[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_9e740a8bf83ea3bf.png||alt="image-20220824163448-3.png" height="557" width="974"]] 438 + 299 299 **✎Note:** 300 300 301 301 * The S7-1200 supports simultaneous connection of three devices, so the driver supports simultaneous access to PLC by three V-BOX. 302 302 * V-BOX access PLC, use S7 protocol, access PLC TSAP 02.01 (s7-1200 PROFINET interface only supports three connections, the default support), detailed reference to the system manual of S7-1200. 303 303 304 -** 4)Cable Wiring**444 +**Cable Wiring** 305 305 306 - {{id name="Iimage-20220824162342-2.png"/}}[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_ac8ece9a26719fda.png||alt="image-20220824162342-2.png" height="170" width="401"]]446 +[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_ac8ece9a26719fda.png||alt="image-20220824162342-2.png" height="170" width="401"]] 307 307 308 308 == {{id name="HLOGOEthernet"/}}**LOGO Ethernet ** == 309 309 ... ... @@ -340,19 +340,19 @@ 340 340 341 341 Click [Tools]~-~-[Ethernet Connections],shown as below. 342 342 343 - {{id name="IPIStudio.125C.PLCprotocols.WebHome4012.PLCProtocol_html_8b9d2322edf89519.png"/}}[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_d13df637bfedcc52.png||alt="12.PLC Protocol_html_8b9d2322edf89519.png" height="641" width="423"]]483 +[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_d13df637bfedcc52.png||alt="12.PLC Protocol_html_8b9d2322edf89519.png" height="641" width="423"]] 344 344 345 345 Set Ethernet connection parameter. IP, Subnet Mask, shown as below. 346 346 347 - {{id name="IPIStudio.125C.PLCprotocols.WebHome40image-20221228142937-4.png"/}}[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_316247e0130c4c55.png||alt="image-20221228142937-4.png" height="484" width="366"]]487 +[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_316247e0130c4c55.png||alt="image-20221228142937-4.png" height="484" width="366"]] 348 348 349 349 **TSAP set**:The value set by local TSAP is the remote TSAP set in HMI. PLC's remote TSAP is the opposite,shown as below. 350 350 351 - {{id name="IPIStudio.125C.PLCprotocols.WebHome40image-20221228143047-5.png"/}}[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_facc6ee1af05162f.png||alt="image-20221228143047-5.png" height="626" width="1088"]]491 +[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_facc6ee1af05162f.png||alt="image-20221228143047-5.png" height="626" width="1088"]] 352 352 353 353 **Download Project**: Click "Address book" to add the IP address to be downloaded (fi."Detect" to check whether the IP address can be detected. Then click “ok”, and the system will prompt that PLC will be "STOP" mode. Click “YES” to start download. 354 354 355 - {{id name="IPIStudio.125C.PLCprotocols.WebHome40image-20221228143246-6.png"/}}[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_d43d2b7b2599ee64.png||alt="image-20221228143246-6.png" height="698" width="688"]]495 +[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_d43d2b7b2599ee64.png||alt="image-20221228143246-6.png" height="698" width="688"]] 356 356 357 357 **V-BOX Communication Settings** 358 358
- 1697099618537-157.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.AiXia - Size
-
... ... @@ -1,0 +1,1 @@ 1 +36.4 KB - Content
- xwiki_PIStudio_12.PLC+protocols_WebHome_664a826cd356c830.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.AiXia - Size
-
... ... @@ -1,0 +1,1 @@ 1 +82.1 KB - Content
- xwiki_PIStudio_12.PLC+protocols_WebHome_78026942a88f0fdb.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.AiXia - Size
-
... ... @@ -1,0 +1,1 @@ 1 +39.3 KB - Content
- xwiki_PIStudio_12.PLC+protocols_WebHome_872ec32d12b55aa.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.AiXia - Size
-
... ... @@ -1,0 +1,1 @@ 1 +133.4 KB - Content
- xwiki_PIStudio_12.PLC+protocols_WebHome_8ee8d3ac3637bfc4.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.AiXia - Size
-
... ... @@ -1,0 +1,1 @@ 1 +96.9 KB - Content
- xwiki_PIStudio_12.PLC+protocols_WebHome_ac8ece9a26719fda.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.AiXia - Size
-
... ... @@ -1,0 +1,1 @@ 1 +107.1 KB - Content
- 西门子1200协议参数.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.AiXia - Size
-
... ... @@ -1,0 +1,1 @@ 1 +64.6 KB - Content