From version 30.1
edited by Theodore Xu
on 2023/08/28 10:15
on 2023/08/28 10:15
Change comment:
There is no comment for this version
To version 46.1
edited by Theodore Xu
on 2023/10/12 17:06
on 2023/10/12 17:06
Change comment:
There is no comment for this version
Summary
-
Page properties (1 modified, 0 added, 0 removed)
-
Attachments (0 modified, 7 added, 0 removed)
- 1697099618537-157.png
- xwiki_PIStudio_12.PLC+protocols_WebHome_664a826cd356c830.png
- xwiki_PIStudio_12.PLC+protocols_WebHome_78026942a88f0fdb.png
- xwiki_PIStudio_12.PLC+protocols_WebHome_872ec32d12b55aa.png
- xwiki_PIStudio_12.PLC+protocols_WebHome_8ee8d3ac3637bfc4.png
- xwiki_PIStudio_12.PLC+protocols_WebHome_ac8ece9a26719fda.png
- 西门子1200协议参数.png
Details
- Page properties
-
- Content
-
... ... @@ -1,39 +3,37 @@ 1 -= **Siemens ** = 2 - 3 3 == **S7-200 Smart Serial** == 4 4 3 +**V-BOX setting** 5 5 6 -**1)V-BOX setting** 5 +(% style="width:1323.87px" %) 6 +|**Items**|**Settings**|**Note** 7 +|Protocol|(% style="width:783px" %)Siemens S7-200 CPU22x/Smart PPI| 8 +|Connection|(% style="width:783px" %)RS485| 9 +|Baud rate|(% style="width:783px" %)9600| 10 +|Data bit|(% style="width:783px" %)8| 11 +|Parity|(% style="width:783px" %)EVEN| 12 +|Stop bit|(% style="width:783px" %)1| 13 +|PLC station No.|(% style="width:783px" %)2| 7 7 8 -|**Item**|**Settings**|**Note** 9 -|Protocol|Siemens S7-200 CPU22x/Smart PPI| 10 -|Connection|RS485| 11 -|Baud rate|9600| 12 -|Data bit|8| 13 -|Parity|EVEN| 14 -|Stop bit|1| 15 -|PLC station No.|2 16 - 17 17 (% style="text-align:center" %) 18 18 [[image:西门子200串口.png]] 19 19 20 -** 2)Address List **18 +**Address List ** 21 21 22 -|**Type**|**Device register**|** HMI register**|**Format**|**Range**|**Note**23 -|(% rowspan="9" %)Bit|I|I |Iddddd.o|0.0~~99999.7|24 -|Q|Q |Qddddd.o|0.0~~99999.7|25 -|V|VWbit |VWbitddddd.o|0.0~~99999.7|26 -|V|V |Vddddd.o|0.0~~99999.7|27 -|M|M |Mddddd.o|0.0~~99999.7|28 -|SM| SM|ddddd.o|0.0~~99999.7|29 -|S| S|ddddd.o|0.0~~99999.7|Read only30 -|T| T|ddddd|0~~99999|Timer state, read only31 -|C| C|ddddd|0~~99999|Counter state, read only32 -|(% rowspan="12" %)Word|I|IW |IWddddd|0~~99999|33 -|Q|QW |QWddddd|0~~99999|34 -|AI|AIW |AIWddddd|0~~99999|35 -|AQ|VB |VBddddd|0~~99999|36 -|V|VW |VWddddd|0~~99998|(((20 +|**Type**|**Device register**|**Format**|**Range**|**Note** 21 +|(% rowspan="9" %)Bit|I|I ddddd.o|0.0~~99999.7| 22 +|Q|Q ddddd.o|0.0~~99999.7| 23 +|V|VWbit ddddd.o|0.0~~99999.7| 24 +|V|V ddddd.o|0.0~~99999.7| 25 +|M|M ddddd.o|0.0~~99999.7| 26 +|SM|ddddd.o|0.0~~99999.7| 27 +|S|ddddd.o|0.0~~99999.7|Read only 28 +|T|ddddd|0~~99999|Timer state, read only 29 +|C|ddddd|0~~99999|Counter state, read only 30 +|(% rowspan="12" %)Word|I|IW ddddd|0~~99999| 31 +|Q|QW ddddd|0~~99999| 32 +|AI|AIW ddddd|0~~99999| 33 +|AQ|VB ddddd|0~~99999| 34 +|V|VW ddddd|0~~99998|((( 37 37 VW0=VB (0~~1) 38 38 39 39 VW2=VB (2~~3) ... ... @@ -40,7 +40,7 @@ 40 40 41 41 Address value is a multiple of 2 42 42 ))) 43 -|V|VD |VDddddd|0~~99998|(((41 +|V|VD ddddd|0~~99998|((( 44 44 VD0=VB (0~~3) 45 45 46 46 VD2=VB (4~~7) ... ... @@ -47,8 +47,8 @@ 47 47 48 48 Address value is a multiple of 4 49 49 ))) 50 -|M|MB |MBddddd|0~~99999|51 -|M|MW |MWddddd|0~~99999|(((48 +|M|MB ddddd|0~~99999| 49 +|M|MW ddddd|0~~99999|((( 52 52 MW0=MB(0~~1) 53 53 54 54 MW2=MB(2~~3) ... ... @@ -55,7 +55,7 @@ 55 55 56 56 Address value is a multiple of 2 57 57 ))) 58 -|M|MD |MDddddd|0~~99999|(((56 +|M|MD ddddd|0~~99999|((( 59 59 MD0=MB(0~~3) 60 60 61 61 MD4=MB(4~~7) ... ... @@ -62,21 +62,19 @@ 62 62 63 63 Address value is a multiple of 4 64 64 ))) 65 -|T|TW |TWddddd|0~~99999|Value of timer66 -|C|CW |CWddddd|0~~99999|Value of counter67 -|W|SW |SWddddd|0~~99999|63 +|T|TW ddddd|0~~99999|Value of timer 64 +|C|CW ddddd|0~~99999|Value of counter 65 +|W|SW ddddd|0~~99999| 68 68 69 -** 3)PLC software**67 +**PLC setting** 70 70 71 71 (% style="text-align:center" %) 72 72 [[image:西门子软件版本.png]] 73 73 74 -**4)PLC Software Configuration** 75 - 76 76 (% style="text-align:center" %) 77 77 [[image:485通讯配置.png]] 78 78 79 -** 5)Connect and Download**75 +**Connect and Download** 80 80 81 81 (% style="text-align:center" %) 82 82 [[image:以太网 PC和PLC连接.png]] ... ... @@ -84,7 +84,7 @@ 84 84 (% style="text-align:center" %) 85 85 [[image:以太网下载.png]] 86 86 87 -** 6)wiring**83 +**Cable Wiring** 88 88 89 89 (% style="text-align:center" %) 90 90 [[image:485接线.png]] ... ... @@ -91,37 +91,34 @@ 91 91 92 92 == **S7-200 Smart Ethernet ** == 93 93 94 -** 1)V-BOX setting**90 +**V-BOX setting** 95 95 96 -|**Items**|**Settings** |**Note**97 -|Protocol|Siemens S7-200 Smart(Ethernet) |98 -|Connection|Ethernet |99 -|Port No.|102 |100 -|PLC station No.|2 |92 +|**Items**|**Settings** 93 +|Protocol|Siemens S7-200 Smart(Ethernet) 94 +|Connection|Ethernet 95 +|Port No.|102 96 +|PLC station No.|2 101 101 102 102 (% style="text-align:center" %) 103 103 [[image:西门子200smart 以太网.png]] 104 104 105 -** 2)PLC software**101 +**PLC setting** 106 106 107 107 (% style="text-align:center" %) 108 108 [[image:西门子软件版本.png]] 109 109 110 -**3)PLC Software Configuration** 111 - 112 112 (% style="text-align:center" %) 113 113 [[image:以太网通讯配置.png]] 114 114 115 -** 4)Connect and Download**109 +**Connect and Download** 116 116 117 117 (% style="text-align:center" %) 118 118 [[image:以太网 PC和PLC连接.png]] 119 119 120 - 121 121 (% style="text-align:center" %) 122 122 [[image:以太网下载.png]] 123 123 124 -** 5)wiring**117 +**Cable Wiring** 125 125 126 126 V-Box : RJ45 Ethernet interface 127 127 ... ... @@ -130,11 +130,11 @@ 130 130 (% style="text-align:center" %) 131 131 [[image:以太网连接.png]] 132 132 133 -== {{id name="HS7-300Ethernet"/}}**S7-300 Ethernet ** ==126 +== **S7-300 Ethernet ** == 134 134 135 135 Supported Series: Siemens S7-300 series PLC 136 136 137 -** 1)V-BOX setting**130 +**V-BOX setting** 138 138 139 139 |**Items**|**Settings**|**Note** 140 140 |Protocol|Simens S7-300 Ethernet| ... ... @@ -142,21 +142,21 @@ 142 142 |Port No.|102| 143 143 |PLC station No.|2|Need to be same as the PLC setting 144 144 145 -** 2)Address List**138 +**Address List** 146 146 147 -|**Type**|**Device register**|** HMI register**|**Format**|**Range**|**Note**148 -|(% rowspan="4" %)Bit|I|I |Iddddd.o|0.0~~99999.7|149 -|Q|Q |Qddddd.o|0.0~~99999.7|150 -|M|M |Mddddd.o|0.0~~99999.7|151 -|DB0.DB~~DB99.DB|DBxDB D|DBxDBnndddd.o|0.0~~99999999.7|(((140 +|**Type**|**Device register**|**Format**|**Range**|**Note** 141 +|(% rowspan="4" %)Bit|I|I ddddd.o|0.0~~99999.7| 142 +|Q|Q ddddd.o|0.0~~99999.7| 143 +|M|M ddddd.o|0.0~~99999.7| 144 +|DB0.DB~~DB99.DB|DBxDB nndddd.o|0.0~~99999999.7|((( 152 152 nn: block number; 153 153 154 154 dddd: address; 155 155 ))) 156 -|(% rowspan="8" %)Word|I|IW |IWddddd|0~~99999|157 -|Q|QW |QWddddd|0~~99999|158 -|(% rowspan="3" %)M|MB |MBddddd|0~~99999|159 -|MW |MWddddd|0~~99999|(((149 +|(% rowspan="8" %)Word|I|IW ddddd|0~~99999| 150 +|Q|QW ddddd|0~~99999| 151 +|(% rowspan="3" %)M|MB ddddd|0~~99999| 152 +|MW ddddd|0~~99999|((( 160 160 MW0=MB(0~~1) 161 161 162 162 MW2=MB(2~~3) ... ... @@ -163,7 +163,7 @@ 163 163 164 164 Address value is a multiple of 2 165 165 ))) 166 -|MD |MDddddd|0~~99999|(((159 +|MD ddddd|0~~99999|((( 167 167 MD0=MB(0~~3) 168 168 169 169 MD4=MB(4~~7) ... ... @@ -170,49 +170,39 @@ 170 170 171 171 Address value is a multiple of 4 172 172 ))) 173 -|(% rowspan="3" %)DB0.DB~~DB99.DB|DBxDBB |DBxDBBnndddd|0~~99999999|(% rowspan="3" %)(((166 +|(% rowspan="3" %)DB0.DB~~DB99.DB|DBxDBB nndddd|0~~99999999|(% rowspan="3" %)((( 174 174 nn: block number; 175 175 176 176 dddd: address 177 177 ))) 178 -|DBxDBW |DBxDBWnndddd|0~~99999999179 -|DBxDBD |DBxDBDnndddd|0~~99999999171 +|DBxDBW nndddd|0~~99999999 172 +|DBxDBD nndddd|0~~99999999 180 180 181 -** 3)Configure the communication protocol**174 +**Configure the communication protocol** 182 182 183 - {{id name="Iimage-20220824161345-1.png"/}}[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_8e00ed9483ddb629.png||alt="image-20220824161345-1.png" height="1011" width="1920"]]176 +[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_8e00ed9483ddb629.png||alt="image-20220824161345-1.png" height="1011" width="1920"]] 184 184 185 -** 4)Cable Wiring**178 +**Cable Wiring** 186 186 187 - {{id name="Iimage-20220824161450-2.png"/}}[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_ac8ece9a26719fda.png||alt="image-20220824161450-2.png" height="170" width="401"]]180 +[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_ac8ece9a26719fda.png||alt="image-20220824161450-2.png" height="170" width="401"]] 188 188 189 -== {{id name="HS7-1200A0Ethernet"/}}**S7-1200 Ethernet ** ==182 +== **S7-1200 Ethernet ** == 190 190 191 191 [[download link>>url:https://ftp.we-con.com.cn/Download/WIKI/V-BOX/Demo/%E9%80%9A%E8%AE%AF%E6%A1%88%E4%BE%8B/Communicate%20with%20S7-1200%20via%20Ehernet.zip]] 192 192 193 - ==**S7-XXXEthernet**==186 +**V-BOX Setting** 194 194 195 -Supported Series: Siemens S7-400, S7-1200 and S7-1500 196 - 197 -**1)V-BOX setting** 198 - 199 -|=**Items**|=**Settings**|=**Note** 200 -|Protocol|Siemens S7-XXX| 188 +|**Items**|**Settings**|**Note** 189 +|Protocol|Siemens S7-1200| 201 201 |Connection|Ethernet| 202 202 |Port No.|102| 203 -|Device No.|Slot (Default 1 for S7-1500/ 2 for S7-1200/ 3 for S7-400)| 204 -|HMI No.|Rack (Default as 0)| 192 +|PLC station No.|2| 205 205 206 -Slot from TIA Portal is equal to Device No. of V-net 194 +(% style="text-align:center" %) 195 +[[image:西门子1200协议参数.png]] 207 207 208 - Rack from TIAPortalisequalto HMI No. of V-net197 +**Address List** 209 209 210 -{{id name="Iimage-20220824162459-3.png"/}}[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_d78bc267e5fc6394.png||alt="image-20220824162459-3.png" height="503" width="798"]] 211 - 212 -{{id name="Iimage-20220824163305-2.png"/}}[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_c9ae84ef5d418580.png||alt="image-20220824163305-2.png" height="1009" width="1920"]] 213 - 214 -**2)Address List** 215 - 216 216 |**Type**|**Device register**|**HMI register**|**Format**|**Range**|**Note** 217 217 |(% rowspan="4" %)Bit|I|I|M d.o|((( 218 218 d:0~-~-9999 ... ... @@ -291,18 +291,176 @@ 291 291 Address value is a multiple of 4 292 292 ))) 293 293 294 -**3)Configure the communication protocol** 277 +{{info}} 278 +✎Note: 295 295 296 -{{id name="Iimage-20220824163448-3.png"/}}[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_9e740a8bf83ea3bf.png||alt="image-20220824163448-3.png" height="557" width="974"]] 280 +* The S7-1200 supports simultaneous connection of three devices. 281 +* V-BOX access PLC, use S7 protocol, access PLC TSAP 02.01 (S7-1200 PROFINET interface only supports three connections, the default support), detailed reference to the system manual of S7-1200. 282 +* S7-1200 String type, the default first two bytes are used to store the maximum character and valid characters, so the text data will be shifted back one word address. When interacting with the data, what way this address plc is displayed with is unknown. And because of an extra word of data causes us to display the wrong. The solution is if we use String, then the actual data address we want to operate on is actually shifted back two bytes, so as long as the address on the project is shifted back 2 bits to correspond with the actual data address. 283 +* V-BOX operation character length needs to be set to 2 times the length of the Siemens character for proper display 284 +{{/info}} 297 297 286 +**PLC Settings** 287 + 288 +Add BD 289 + 290 +* Please uncheck [Symbolic access only] option; 291 + 292 +(% style="text-align:center" %) 293 +[[image:xwiki_PIStudio_12.PLC+protocols_WebHome_872ec32d12b55aa.png]] 294 + 295 +Address settings, using BD2 as example. 296 + 297 +* DB×DBB2xxxx, DB×DBW2xxxx, DB×DBD2xxxx for accessing data of DB2 in B1. 298 +* 2 represent DB block number 299 +* xxxx represent address 300 + 301 +**Such as:** 302 + 303 +* DBxDBB20000 = DB2.DBB0 304 +* DBxDBW20004 = DB2.DBW4 305 + 306 +(% style="text-align:center" %) 307 +[[image:xwiki_PIStudio_12.PLC+protocols_WebHome_8ee8d3ac3637bfc4.png]] 308 + 309 +**How to connect with S7-1200 Firmware V4.0** 310 + 311 +PLC configuration 312 + 313 +* Double click [device configuration] in Siemens via software 314 +* Double click [protection] to enter protection configuration screen 315 + 316 +(% style="text-align:center" %) 317 +[[image:xwiki_PIStudio_12.PLC+protocols_WebHome_664a826cd356c830.png]] 318 + 319 +* Check [Permit access with PUT / GET communication from remote partner (PLC, HMI, OPC, ...)] 320 + 321 +(% style="text-align:center" %) 322 +[[image:xwiki_PIStudio_12.PLC+protocols_WebHome_78026942a88f0fdb.png]] 323 + 324 +DB settings 325 + 326 +* Right click [DB], select [properties] 327 +* Uncheck [optimized block access] 328 + 329 +**Cable Wiring** 330 + 331 +(% style="text-align:center" %) 332 +[[image:xwiki_PIStudio_12.PLC+protocols_WebHome_ac8ece9a26719fda.png]] 333 + 334 +== **S7-XXX Ethernet** == 335 + 336 +Supported Series: Siemens S7-400, S7-1200 and S7-1500 337 + 338 +**V-BOX setting** 339 + 340 +|=**Items**|=**Settings**|=**Note** 341 +|Protocol|Siemens S7-XXX| 342 +|Connection|Ethernet| 343 +|Port No.|102| 344 +|Device No.|Slot (Default 1 for S7-1500/ 2 for S7-1200/ 3 for S7-400)| 345 +|HMI No.|Rack (Default as 0)| 346 + 347 +Slot from TIA Portal is equal to Device No. of V-net 348 + 349 +Rack from TIA Portal is equal to HMI No. of V-net 350 + 351 +[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_d78bc267e5fc6394.png||alt="image-20220824162459-3.png" height="503" width="798"]] 352 + 353 +[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_c9ae84ef5d418580.png||alt="image-20220824163305-2.png" height="1009" width="1920"]] 354 + 355 +**Address List** 356 + 357 +|**Type**|**Device register**|**Format**|**Range**|**Note** 358 +|(% rowspan="4" %)Bit|I|M d.o|((( 359 +d:0~-~-9999 360 + 361 +o:0-7 362 +)))| 363 +|Q|Q d.o|((( 364 +d:0~-~-9999 365 + 366 +o:0-7 367 +)))| 368 +|M|M d.o|((( 369 +d:0~-~-9999 370 + 371 +o:0-7 372 +)))| 373 +|DB0.DB-DB99.DB|DBxDBnndddd.o|((( 374 +nn:0-9999, 375 + 376 +dddd:0-9999, 377 + 378 +o:0-7 379 +)))|((( 380 +nn:DB No. 381 + 382 +dddd:address value 383 + 384 +o: digit address 385 +))) 386 +|(% rowspan="8" %)Word|M|MB d|d:0-99999| 387 +|M|MW d|d:0-99999|((( 388 +MW0=MB(0~~1) 389 + 390 +MW2=MB(2~~3) 391 + 392 +Address value is a multiple of 2 393 +))) 394 +|M|MD d|d:0-99999|((( 395 +MD0=MB(0~~3) 396 + 397 +MD4=MB(4~~7) 398 + 399 +Address value is a multiple of 4 400 +))) 401 +|I|IW d|d:0-99999| 402 +|Q|QW d|d:0-99999| 403 +|DB0.DB-DB99.DB|DBxDBBnndddd|((( 404 +nn:0-9999 405 + 406 +dddd:0-9999 407 +)))|((( 408 +nn:DB No. 409 + 410 +dddd:address value 411 +))) 412 +|DB0.DB-DB99.DB|DBxDBWnndddd|((( 413 +nn:0-9999 414 + 415 +dddd:0-9999 416 +)))|((( 417 +nn:DB No. 418 + 419 +dddd:address value 420 + 421 +Address value is a multiple of 2 422 +))) 423 +|DB0.DB-DB99.DB|DBxDBDnndddd|((( 424 +nn:0-9999 425 + 426 +dddd:0-9999 427 +)))|((( 428 +nn:DB No. 429 + 430 +dddd:address value 431 + 432 +Address value is a multiple of 4 433 +))) 434 + 435 +**Configure the communication protocol** 436 + 437 +[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_9e740a8bf83ea3bf.png||alt="image-20220824163448-3.png" height="557" width="974"]] 438 + 298 298 **✎Note:** 299 299 300 300 * The S7-1200 supports simultaneous connection of three devices, so the driver supports simultaneous access to PLC by three V-BOX. 301 301 * V-BOX access PLC, use S7 protocol, access PLC TSAP 02.01 (s7-1200 PROFINET interface only supports three connections, the default support), detailed reference to the system manual of S7-1200. 302 302 303 -** 4)Cable Wiring**444 +**Cable Wiring** 304 304 305 - {{id name="Iimage-20220824162342-2.png"/}}[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_ac8ece9a26719fda.png||alt="image-20220824162342-2.png" height="170" width="401"]]446 +[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_ac8ece9a26719fda.png||alt="image-20220824162342-2.png" height="170" width="401"]] 306 306 307 307 == {{id name="HLOGOEthernet"/}}**LOGO Ethernet ** == 308 308 ... ... @@ -339,19 +339,19 @@ 339 339 340 340 Click [Tools]~-~-[Ethernet Connections],shown as below. 341 341 342 - {{id name="IPIStudio.125C.PLCprotocols.WebHome4012.PLCProtocol_html_8b9d2322edf89519.png"/}}[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_d13df637bfedcc52.png||alt="12.PLC Protocol_html_8b9d2322edf89519.png" height="641" width="423"]]483 +[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_d13df637bfedcc52.png||alt="12.PLC Protocol_html_8b9d2322edf89519.png" height="641" width="423"]] 343 343 344 344 Set Ethernet connection parameter. IP, Subnet Mask, shown as below. 345 345 346 - {{id name="IPIStudio.125C.PLCprotocols.WebHome40image-20221228142937-4.png"/}}[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_316247e0130c4c55.png||alt="image-20221228142937-4.png" height="484" width="366"]]487 +[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_316247e0130c4c55.png||alt="image-20221228142937-4.png" height="484" width="366"]] 347 347 348 348 **TSAP set**:The value set by local TSAP is the remote TSAP set in HMI. PLC's remote TSAP is the opposite,shown as below. 349 349 350 - {{id name="IPIStudio.125C.PLCprotocols.WebHome40image-20221228143047-5.png"/}}[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_facc6ee1af05162f.png||alt="image-20221228143047-5.png" height="626" width="1088"]]491 +[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_facc6ee1af05162f.png||alt="image-20221228143047-5.png" height="626" width="1088"]] 351 351 352 352 **Download Project**: Click "Address book" to add the IP address to be downloaded (fi."Detect" to check whether the IP address can be detected. Then click “ok”, and the system will prompt that PLC will be "STOP" mode. Click “YES” to start download. 353 353 354 - {{id name="IPIStudio.125C.PLCprotocols.WebHome40image-20221228143246-6.png"/}}[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_d43d2b7b2599ee64.png||alt="image-20221228143246-6.png" height="698" width="688"]]495 +[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_d43d2b7b2599ee64.png||alt="image-20221228143246-6.png" height="698" width="688"]] 355 355 356 356 **V-BOX Communication Settings** 357 357
- 1697099618537-157.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.AiXia - Size
-
... ... @@ -1,0 +1,1 @@ 1 +36.4 KB - Content
- xwiki_PIStudio_12.PLC+protocols_WebHome_664a826cd356c830.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.AiXia - Size
-
... ... @@ -1,0 +1,1 @@ 1 +82.1 KB - Content
- xwiki_PIStudio_12.PLC+protocols_WebHome_78026942a88f0fdb.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.AiXia - Size
-
... ... @@ -1,0 +1,1 @@ 1 +39.3 KB - Content
- xwiki_PIStudio_12.PLC+protocols_WebHome_872ec32d12b55aa.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.AiXia - Size
-
... ... @@ -1,0 +1,1 @@ 1 +133.4 KB - Content
- xwiki_PIStudio_12.PLC+protocols_WebHome_8ee8d3ac3637bfc4.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.AiXia - Size
-
... ... @@ -1,0 +1,1 @@ 1 +96.9 KB - Content
- xwiki_PIStudio_12.PLC+protocols_WebHome_ac8ece9a26719fda.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.AiXia - Size
-
... ... @@ -1,0 +1,1 @@ 1 +107.1 KB - Content
- 西门子1200协议参数.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.AiXia - Size
-
... ... @@ -1,0 +1,1 @@ 1 +64.6 KB - Content