From version 33.1
edited by Theodore Xu
on 2023/09/12 10:55
on 2023/09/12 10:55
Change comment:
There is no comment for this version
To version 40.1
edited by Theodore Xu
on 2023/09/15 11:58
on 2023/09/15 11:58
Change comment:
There is no comment for this version
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -1,17 +3,16 @@ 1 -= **Siemens ** = 2 - 3 3 == **S7-200 Smart Serial** == 4 4 5 5 **V-BOX setting** 6 6 7 7 (% style="width:1323.87px" %) 8 -|Protocol|(% style="width:783px" %)Siemens S7-200 CPU22x/Smart PPI 9 -|Connection|(% style="width:783px" %)RS485 10 -|Baud rate|(% style="width:783px" %)9600 11 -|Data bit|(% style="width:783px" %)8 12 -|Parity|(% style="width:783px" %)EVEN 13 -|Stop bit|(% style="width:783px" %)1 14 -|PLC station No.|(% style="width:783px" %)2 6 +|**Items**|**Settings**|**Note** 7 +|Protocol|(% style="width:783px" %)Siemens S7-200 CPU22x/Smart PPI| 8 +|Connection|(% style="width:783px" %)RS485| 9 +|Baud rate|(% style="width:783px" %)9600| 10 +|Data bit|(% style="width:783px" %)8| 11 +|Parity|(% style="width:783px" %)EVEN| 12 +|Stop bit|(% style="width:783px" %)1| 13 +|PLC station No.|(% style="width:783px" %)2| 15 15 16 16 (% style="text-align:center" %) 17 17 [[image:西门子200串口.png]] ... ... @@ -18,21 +18,21 @@ 18 18 19 19 **Address List ** 20 20 21 -|**Type**|**Device register**|** HMI register**|**Format**|**Range**|**Note**22 -|(% rowspan="9" %)Bit|I|I |Iddddd.o|0.0~~99999.7|23 -|Q|Q |Qddddd.o|0.0~~99999.7|24 -|V|VWbit |VWbitddddd.o|0.0~~99999.7|25 -|V|V |Vddddd.o|0.0~~99999.7|26 -|M|M |Mddddd.o|0.0~~99999.7|27 -|SM| SM|ddddd.o|0.0~~99999.7|28 -|S| S|ddddd.o|0.0~~99999.7|Read only29 -|T| T|ddddd|0~~99999|Timer state, read only30 -|C| C|ddddd|0~~99999|Counter state, read only31 -|(% rowspan="12" %)Word|I|IW |IWddddd|0~~99999|32 -|Q|QW |QWddddd|0~~99999|33 -|AI|AIW |AIWddddd|0~~99999|34 -|AQ|VB |VBddddd|0~~99999|35 -|V|VW |VWddddd|0~~99998|(((20 +|**Type**|**Device register**|**Format**|**Range**|**Note** 21 +|(% rowspan="9" %)Bit|I|I ddddd.o|0.0~~99999.7| 22 +|Q|Q ddddd.o|0.0~~99999.7| 23 +|V|VWbit ddddd.o|0.0~~99999.7| 24 +|V|V ddddd.o|0.0~~99999.7| 25 +|M|M ddddd.o|0.0~~99999.7| 26 +|SM|ddddd.o|0.0~~99999.7| 27 +|S|ddddd.o|0.0~~99999.7|Read only 28 +|T|ddddd|0~~99999|Timer state, read only 29 +|C|ddddd|0~~99999|Counter state, read only 30 +|(% rowspan="12" %)Word|I|IW ddddd|0~~99999| 31 +|Q|QW ddddd|0~~99999| 32 +|AI|AIW ddddd|0~~99999| 33 +|AQ|VB ddddd|0~~99999| 34 +|V|VW ddddd|0~~99998|((( 36 36 VW0=VB (0~~1) 37 37 38 38 VW2=VB (2~~3) ... ... @@ -39,7 +39,7 @@ 39 39 40 40 Address value is a multiple of 2 41 41 ))) 42 -|V|VD |VDddddd|0~~99998|(((41 +|V|VD ddddd|0~~99998|((( 43 43 VD0=VB (0~~3) 44 44 45 45 VD2=VB (4~~7) ... ... @@ -46,8 +46,8 @@ 46 46 47 47 Address value is a multiple of 4 48 48 ))) 49 -|M|MB |MBddddd|0~~99999|50 -|M|MW |MWddddd|0~~99999|(((48 +|M|MB ddddd|0~~99999| 49 +|M|MW ddddd|0~~99999|((( 51 51 MW0=MB(0~~1) 52 52 53 53 MW2=MB(2~~3) ... ... @@ -54,7 +54,7 @@ 54 54 55 55 Address value is a multiple of 2 56 56 ))) 57 -|M|MD |MDddddd|0~~99999|(((56 +|M|MD ddddd|0~~99999|((( 58 58 MD0=MB(0~~3) 59 59 60 60 MD4=MB(4~~7) ... ... @@ -61,9 +61,9 @@ 61 61 62 62 Address value is a multiple of 4 63 63 ))) 64 -|T|TW |TWddddd|0~~99999|Value of timer65 -|C|CW |CWddddd|0~~99999|Value of counter66 -|W|SW |SWddddd|0~~99999|63 +|T|TW ddddd|0~~99999|Value of timer 64 +|C|CW ddddd|0~~99999|Value of counter 65 +|W|SW ddddd|0~~99999| 67 67 68 68 **PLC setting** 69 69 ... ... @@ -90,11 +90,11 @@ 90 90 91 91 **V-BOX setting** 92 92 93 -|**Items**|**Settings** |**Note**94 -|Protocol|Siemens S7-200 Smart(Ethernet) |95 -|Connection|Ethernet |96 -|Port No.|102 |97 -|PLC station No.|2 |92 +|**Items**|**Settings** 93 +|Protocol|Siemens S7-200 Smart(Ethernet) 94 +|Connection|Ethernet 95 +|Port No.|102 96 +|PLC station No.|2 98 98 99 99 (% style="text-align:center" %) 100 100 [[image:西门子200smart 以太网.png]] ... ... @@ -138,19 +138,19 @@ 138 138 139 139 **2)Address List** 140 140 141 -|**Type**|**Device register**|** HMI register**|**Format**|**Range**|**Note**142 -|(% rowspan="4" %)Bit|I|I |Iddddd.o|0.0~~99999.7|143 -|Q|Q |Qddddd.o|0.0~~99999.7|144 -|M|M |Mddddd.o|0.0~~99999.7|145 -|DB0.DB~~DB99.DB|DBxDB D|DBxDBnndddd.o|0.0~~99999999.7|(((140 +|**Type**|**Device register**|**Format**|**Range**|**Note** 141 +|(% rowspan="4" %)Bit|I|I ddddd.o|0.0~~99999.7| 142 +|Q|Q ddddd.o|0.0~~99999.7| 143 +|M|M ddddd.o|0.0~~99999.7| 144 +|DB0.DB~~DB99.DB|DBxDB nndddd.o|0.0~~99999999.7|((( 146 146 nn: block number; 147 147 148 148 dddd: address; 149 149 ))) 150 -|(% rowspan="8" %)Word|I|IW |IWddddd|0~~99999|151 -|Q|QW |QWddddd|0~~99999|152 -|(% rowspan="3" %)M|MB |MBddddd|0~~99999|153 -|MW |MWddddd|0~~99999|(((149 +|(% rowspan="8" %)Word|I|IW ddddd|0~~99999| 150 +|Q|QW ddddd|0~~99999| 151 +|(% rowspan="3" %)M|MB ddddd|0~~99999| 152 +|MW ddddd|0~~99999|((( 154 154 MW0=MB(0~~1) 155 155 156 156 MW2=MB(2~~3) ... ... @@ -157,7 +157,7 @@ 157 157 158 158 Address value is a multiple of 2 159 159 ))) 160 -|MD |MDddddd|0~~99999|(((159 +|MD ddddd|0~~99999|((( 161 161 MD0=MB(0~~3) 162 162 163 163 MD4=MB(4~~7) ... ... @@ -164,13 +164,13 @@ 164 164 165 165 Address value is a multiple of 4 166 166 ))) 167 -|(% rowspan="3" %)DB0.DB~~DB99.DB|DBxDBB |DBxDBBnndddd|0~~99999999|(% rowspan="3" %)(((166 +|(% rowspan="3" %)DB0.DB~~DB99.DB|DBxDBB nndddd|0~~99999999|(% rowspan="3" %)((( 168 168 nn: block number; 169 169 170 170 dddd: address 171 171 ))) 172 -|DBxDBW |DBxDBWnndddd|0~~99999999173 -|DBxDBD |DBxDBDnndddd|0~~99999999171 +|DBxDBW nndddd|0~~99999999 172 +|DBxDBD nndddd|0~~99999999 174 174 175 175 **3)Configure the communication protocol** 176 176