... ... @@ -1,17 +3,16 @@
1 -= **Siemens ** =
2 -
3 3  == **S7-200 Smart Serial** ==
4 4  
5 5  **V-BOX setting**
6 6  
7 7  (% style="width:1323.87px" %)
8 -|Protocol|(% style="width:783px" %)Siemens S7-200 CPU22x/Smart PPI
9 -|Connection|(% style="width:783px" %)RS485
10 -|Baud rate|(% style="width:783px" %)9600
11 -|Data bit|(% style="width:783px" %)8
12 -|Parity|(% style="width:783px" %)EVEN
13 -|Stop bit|(% style="width:783px" %)1
14 -|PLC station No.|(% style="width:783px" %)2
6 +|**Items**|**Settings**|**Note**
7 +|Protocol|(% style="width:783px" %)Siemens S7-200 CPU22x/Smart PPI|
8 +|Connection|(% style="width:783px" %)RS485|
9 +|Baud rate|(% style="width:783px" %)9600|
10 +|Data bit|(% style="width:783px" %)8|
11 +|Parity|(% style="width:783px" %)EVEN|
12 +|Stop bit|(% style="width:783px" %)1|
13 +|PLC station No.|(% style="width:783px" %)2|
15 15  
16 16  (% style="text-align:center" %)
17 17  [[image:西门子200串口.png]]
... ... @@ -18,21 +18,21 @@
18 18  
19 19  **Address List **
20 20  
21 -|**Type**|**Device register**|**HMI register**|**Format**|**Range**|**Note**
22 -|(% rowspan="9" %)Bit|I|I|I ddddd.o|0.0~~99999.7|
23 -|Q|Q|Q ddddd.o|0.0~~99999.7|
24 -|V|VWbit|VWbit ddddd.o|0.0~~99999.7|
25 -|V|V|V ddddd.o|0.0~~99999.7|
26 -|M|M|M ddddd.o|0.0~~99999.7|
27 -|SM|SM|ddddd.o|0.0~~99999.7|
28 -|S|S|ddddd.o|0.0~~99999.7|Read only
29 -|T|T|ddddd|0~~99999|Timer state, read only
30 -|C|C|ddddd|0~~99999|Counter state, read only
31 -|(% rowspan="12" %)Word|I|IW|IW ddddd|0~~99999|
32 -|Q|QW|QW ddddd|0~~99999|
33 -|AI|AIW|AIW ddddd|0~~99999|
34 -|AQ|VB|VB ddddd|0~~99999|
35 -|V|VW|VW ddddd|0~~99998|(((
20 +|**Type**|**Device register**|**Format**|**Range**|**Note**
21 +|(% rowspan="9" %)Bit|I|I ddddd.o|0.0~~99999.7|
22 +|Q|Q ddddd.o|0.0~~99999.7|
23 +|V|VWbit ddddd.o|0.0~~99999.7|
24 +|V|V ddddd.o|0.0~~99999.7|
25 +|M|M ddddd.o|0.0~~99999.7|
26 +|SM|ddddd.o|0.0~~99999.7|
27 +|S|ddddd.o|0.0~~99999.7|Read only
28 +|T|ddddd|0~~99999|Timer state, read only
29 +|C|ddddd|0~~99999|Counter state, read only
30 +|(% rowspan="12" %)Word|I|IW ddddd|0~~99999|
31 +|Q|QW ddddd|0~~99999|
32 +|AI|AIW ddddd|0~~99999|
33 +|AQ|VB ddddd|0~~99999|
34 +|V|VW ddddd|0~~99998|(((
36 36  VW0=VB (0~~1)
37 37  
38 38  VW2=VB (2~~3)
... ... @@ -39,7 +39,7 @@
39 39  
40 40  Address value is a multiple of 2
41 41  )))
42 -|V|VD|VD ddddd|0~~99998|(((
41 +|V|VD ddddd|0~~99998|(((
43 43  VD0=VB (0~~3)
44 44  
45 45  VD2=VB (4~~7)
... ... @@ -46,8 +46,8 @@
46 46  
47 47  Address value is a multiple of 4
48 48  )))
49 -|M|MB|MB ddddd|0~~99999|
50 -|M|MW|MW ddddd|0~~99999|(((
48 +|M|MB ddddd|0~~99999|
49 +|M|MW ddddd|0~~99999|(((
51 51  MW0=MB(0~~1)
52 52  
53 53  MW2=MB(2~~3)
... ... @@ -54,7 +54,7 @@
54 54  
55 55  Address value is a multiple of 2
56 56  )))
57 -|M|MD|MD ddddd|0~~99999|(((
56 +|M|MD ddddd|0~~99999|(((
58 58  MD0=MB(0~~3)
59 59  
60 60  MD4=MB(4~~7)
... ... @@ -61,9 +61,9 @@
61 61  
62 62  Address value is a multiple of 4
63 63  )))
64 -|T|TW|TW ddddd|0~~99999|Value of timer
65 -|C|CW|CW ddddd|0~~99999|Value of counter
66 -|W|SW|SW ddddd|0~~99999|
63 +|T|TW ddddd|0~~99999|Value of timer
64 +|C|CW ddddd|0~~99999|Value of counter
65 +|W|SW ddddd|0~~99999|
67 67  
68 68  **PLC setting**
69 69  
... ... @@ -90,11 +90,11 @@
90 90  
91 91  **V-BOX setting**
92 92  
93 -|**Items**|**Settings**|**Note**
94 -|Protocol|Siemens S7-200 Smart(Ethernet)|
95 -|Connection|Ethernet|
96 -|Port No.|102|
97 -|PLC station No.|2|
92 +|**Items**|**Settings**
93 +|Protocol|Siemens S7-200 Smart(Ethernet)
94 +|Connection|Ethernet
95 +|Port No.|102
96 +|PLC station No.|2
98 98  
99 99  (% style="text-align:center" %)
100 100  [[image:西门子200smart 以太网.png]]
... ... @@ -138,19 +138,19 @@
138 138  
139 139  **2)Address List**
140 140  
141 -|**Type**|**Device register**|**HMI register**|**Format**|**Range**|**Note**
142 -|(% rowspan="4" %)Bit|I|I|I ddddd.o|0.0~~99999.7|
143 -|Q|Q|Q ddddd.o|0.0~~99999.7|
144 -|M|M|M ddddd.o|0.0~~99999.7|
145 -|DB0.DB~~DB99.DB|DBxDBD|DBxDB nndddd.o|0.0~~99999999.7|(((
140 +|**Type**|**Device register**|**Format**|**Range**|**Note**
141 +|(% rowspan="4" %)Bit|I|I ddddd.o|0.0~~99999.7|
142 +|Q|Q ddddd.o|0.0~~99999.7|
143 +|M|M ddddd.o|0.0~~99999.7|
144 +|DB0.DB~~DB99.DB|DBxDB nndddd.o|0.0~~99999999.7|(((
146 146  nn: block number;
147 147  
148 148  dddd: address;
149 149  )))
150 -|(% rowspan="8" %)Word|I|IW|IW ddddd|0~~99999|
151 -|Q|QW|QW ddddd|0~~99999|
152 -|(% rowspan="3" %)M|MB|MB ddddd|0~~99999|
153 -|MW|MW ddddd|0~~99999|(((
149 +|(% rowspan="8" %)Word|I|IW ddddd|0~~99999|
150 +|Q|QW ddddd|0~~99999|
151 +|(% rowspan="3" %)M|MB ddddd|0~~99999|
152 +|MW ddddd|0~~99999|(((
154 154  MW0=MB(0~~1)
155 155  
156 156  MW2=MB(2~~3)
... ... @@ -157,7 +157,7 @@
157 157  
158 158  Address value is a multiple of 2
159 159  )))
160 -|MD|MD ddddd|0~~99999|(((
159 +|MD ddddd|0~~99999|(((
161 161  MD0=MB(0~~3)
162 162  
163 163  MD4=MB(4~~7)
... ... @@ -164,13 +164,13 @@
164 164  
165 165  Address value is a multiple of 4
166 166  )))
167 -|(% rowspan="3" %)DB0.DB~~DB99.DB|DBxDBB|DBxDBB nndddd|0~~99999999|(% rowspan="3" %)(((
166 +|(% rowspan="3" %)DB0.DB~~DB99.DB|DBxDBB nndddd|0~~99999999|(% rowspan="3" %)(((
168 168  nn: block number;
169 169  
170 170  dddd: address
171 171  )))
172 -|DBxDBW|DBxDBW nndddd|0~~99999999
173 -|DBxDBD|DBxDBD nndddd|0~~99999999
171 +|DBxDBW nndddd|0~~99999999
172 +|DBxDBD nndddd|0~~99999999
174 174  
175 175  **3)Configure the communication protocol**
176 176