From version 33.1
edited by Theodore Xu
on 2023/09/12 10:55
on 2023/09/12 10:55
Change comment:
There is no comment for this version
To version 45.1
edited by Theodore Xu
on 2023/10/12 16:37
on 2023/10/12 16:37
Change comment:
There is no comment for this version
Summary
-
Page properties (1 modified, 0 added, 0 removed)
-
Attachments (0 modified, 1 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -1,17 +3,16 @@ 1 -= **Siemens ** = 2 - 3 3 == **S7-200 Smart Serial** == 4 4 5 5 **V-BOX setting** 6 6 7 7 (% style="width:1323.87px" %) 8 -|Protocol|(% style="width:783px" %)Siemens S7-200 CPU22x/Smart PPI 9 -|Connection|(% style="width:783px" %)RS485 10 -|Baud rate|(% style="width:783px" %)9600 11 -|Data bit|(% style="width:783px" %)8 12 -|Parity|(% style="width:783px" %)EVEN 13 -|Stop bit|(% style="width:783px" %)1 14 -|PLC station No.|(% style="width:783px" %)2 6 +|**Items**|**Settings**|**Note** 7 +|Protocol|(% style="width:783px" %)Siemens S7-200 CPU22x/Smart PPI| 8 +|Connection|(% style="width:783px" %)RS485| 9 +|Baud rate|(% style="width:783px" %)9600| 10 +|Data bit|(% style="width:783px" %)8| 11 +|Parity|(% style="width:783px" %)EVEN| 12 +|Stop bit|(% style="width:783px" %)1| 13 +|PLC station No.|(% style="width:783px" %)2| 15 15 16 16 (% style="text-align:center" %) 17 17 [[image:西门子200串口.png]] ... ... @@ -18,21 +18,21 @@ 18 18 19 19 **Address List ** 20 20 21 -|**Type**|**Device register**|** HMI register**|**Format**|**Range**|**Note**22 -|(% rowspan="9" %)Bit|I|I |Iddddd.o|0.0~~99999.7|23 -|Q|Q |Qddddd.o|0.0~~99999.7|24 -|V|VWbit |VWbitddddd.o|0.0~~99999.7|25 -|V|V |Vddddd.o|0.0~~99999.7|26 -|M|M |Mddddd.o|0.0~~99999.7|27 -|SM| SM|ddddd.o|0.0~~99999.7|28 -|S| S|ddddd.o|0.0~~99999.7|Read only29 -|T| T|ddddd|0~~99999|Timer state, read only30 -|C| C|ddddd|0~~99999|Counter state, read only31 -|(% rowspan="12" %)Word|I|IW |IWddddd|0~~99999|32 -|Q|QW |QWddddd|0~~99999|33 -|AI|AIW |AIWddddd|0~~99999|34 -|AQ|VB |VBddddd|0~~99999|35 -|V|VW |VWddddd|0~~99998|(((20 +|**Type**|**Device register**|**Format**|**Range**|**Note** 21 +|(% rowspan="9" %)Bit|I|I ddddd.o|0.0~~99999.7| 22 +|Q|Q ddddd.o|0.0~~99999.7| 23 +|V|VWbit ddddd.o|0.0~~99999.7| 24 +|V|V ddddd.o|0.0~~99999.7| 25 +|M|M ddddd.o|0.0~~99999.7| 26 +|SM|ddddd.o|0.0~~99999.7| 27 +|S|ddddd.o|0.0~~99999.7|Read only 28 +|T|ddddd|0~~99999|Timer state, read only 29 +|C|ddddd|0~~99999|Counter state, read only 30 +|(% rowspan="12" %)Word|I|IW ddddd|0~~99999| 31 +|Q|QW ddddd|0~~99999| 32 +|AI|AIW ddddd|0~~99999| 33 +|AQ|VB ddddd|0~~99999| 34 +|V|VW ddddd|0~~99998|((( 36 36 VW0=VB (0~~1) 37 37 38 38 VW2=VB (2~~3) ... ... @@ -39,7 +39,7 @@ 39 39 40 40 Address value is a multiple of 2 41 41 ))) 42 -|V|VD |VDddddd|0~~99998|(((41 +|V|VD ddddd|0~~99998|((( 43 43 VD0=VB (0~~3) 44 44 45 45 VD2=VB (4~~7) ... ... @@ -46,8 +46,8 @@ 46 46 47 47 Address value is a multiple of 4 48 48 ))) 49 -|M|MB |MBddddd|0~~99999|50 -|M|MW |MWddddd|0~~99999|(((48 +|M|MB ddddd|0~~99999| 49 +|M|MW ddddd|0~~99999|((( 51 51 MW0=MB(0~~1) 52 52 53 53 MW2=MB(2~~3) ... ... @@ -54,7 +54,7 @@ 54 54 55 55 Address value is a multiple of 2 56 56 ))) 57 -|M|MD |MDddddd|0~~99999|(((56 +|M|MD ddddd|0~~99999|((( 58 58 MD0=MB(0~~3) 59 59 60 60 MD4=MB(4~~7) ... ... @@ -61,9 +61,9 @@ 61 61 62 62 Address value is a multiple of 4 63 63 ))) 64 -|T|TW |TWddddd|0~~99999|Value of timer65 -|C|CW |CWddddd|0~~99999|Value of counter66 -|W|SW |SWddddd|0~~99999|63 +|T|TW ddddd|0~~99999|Value of timer 64 +|C|CW ddddd|0~~99999|Value of counter 65 +|W|SW ddddd|0~~99999| 67 67 68 68 **PLC setting** 69 69 ... ... @@ -90,11 +90,11 @@ 90 90 91 91 **V-BOX setting** 92 92 93 -|**Items**|**Settings** |**Note**94 -|Protocol|Siemens S7-200 Smart(Ethernet) |95 -|Connection|Ethernet |96 -|Port No.|102 |97 -|PLC station No.|2 |92 +|**Items**|**Settings** 93 +|Protocol|Siemens S7-200 Smart(Ethernet) 94 +|Connection|Ethernet 95 +|Port No.|102 96 +|PLC station No.|2 98 98 99 99 (% style="text-align:center" %) 100 100 [[image:西门子200smart 以太网.png]] ... ... @@ -124,11 +124,11 @@ 124 124 (% style="text-align:center" %) 125 125 [[image:以太网连接.png]] 126 126 127 -== {{id name="HS7-300Ethernet"/}}**S7-300 Ethernet ** ==126 +== **S7-300 Ethernet ** == 128 128 129 129 Supported Series: Siemens S7-300 series PLC 130 130 131 -** 1)V-BOX setting**130 +**V-BOX setting** 132 132 133 133 |**Items**|**Settings**|**Note** 134 134 |Protocol|Simens S7-300 Ethernet| ... ... @@ -136,21 +136,21 @@ 136 136 |Port No.|102| 137 137 |PLC station No.|2|Need to be same as the PLC setting 138 138 139 -** 2)Address List**138 +**Address List** 140 140 141 -|**Type**|**Device register**|** HMI register**|**Format**|**Range**|**Note**142 -|(% rowspan="4" %)Bit|I|I |Iddddd.o|0.0~~99999.7|143 -|Q|Q |Qddddd.o|0.0~~99999.7|144 -|M|M |Mddddd.o|0.0~~99999.7|145 -|DB0.DB~~DB99.DB|DBxDB D|DBxDBnndddd.o|0.0~~99999999.7|(((140 +|**Type**|**Device register**|**Format**|**Range**|**Note** 141 +|(% rowspan="4" %)Bit|I|I ddddd.o|0.0~~99999.7| 142 +|Q|Q ddddd.o|0.0~~99999.7| 143 +|M|M ddddd.o|0.0~~99999.7| 144 +|DB0.DB~~DB99.DB|DBxDB nndddd.o|0.0~~99999999.7|((( 146 146 nn: block number; 147 147 148 148 dddd: address; 149 149 ))) 150 -|(% rowspan="8" %)Word|I|IW |IWddddd|0~~99999|151 -|Q|QW |QWddddd|0~~99999|152 -|(% rowspan="3" %)M|MB |MBddddd|0~~99999|153 -|MW |MWddddd|0~~99999|(((149 +|(% rowspan="8" %)Word|I|IW ddddd|0~~99999| 150 +|Q|QW ddddd|0~~99999| 151 +|(% rowspan="3" %)M|MB ddddd|0~~99999| 152 +|MW ddddd|0~~99999|((( 154 154 MW0=MB(0~~1) 155 155 156 156 MW2=MB(2~~3) ... ... @@ -157,7 +157,7 @@ 157 157 158 158 Address value is a multiple of 2 159 159 ))) 160 -|MD |MDddddd|0~~99999|(((159 +|MD ddddd|0~~99999|((( 161 161 MD0=MB(0~~3) 162 162 163 163 MD4=MB(4~~7) ... ... @@ -164,31 +164,123 @@ 164 164 165 165 Address value is a multiple of 4 166 166 ))) 167 -|(% rowspan="3" %)DB0.DB~~DB99.DB|DBxDBB |DBxDBBnndddd|0~~99999999|(% rowspan="3" %)(((166 +|(% rowspan="3" %)DB0.DB~~DB99.DB|DBxDBB nndddd|0~~99999999|(% rowspan="3" %)((( 168 168 nn: block number; 169 169 170 170 dddd: address 171 171 ))) 172 -|DBxDBW |DBxDBWnndddd|0~~99999999173 -|DBxDBD |DBxDBDnndddd|0~~99999999171 +|DBxDBW nndddd|0~~99999999 172 +|DBxDBD nndddd|0~~99999999 174 174 175 -** 3)Configure the communication protocol**174 +**Configure the communication protocol** 176 176 177 - {{id name="Iimage-20220824161345-1.png"/}}[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_8e00ed9483ddb629.png||alt="image-20220824161345-1.png" height="1011" width="1920"]]176 +[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_8e00ed9483ddb629.png||alt="image-20220824161345-1.png" height="1011" width="1920"]] 178 178 179 -** 4)Cable Wiring**178 +**Cable Wiring** 180 180 181 - {{id name="Iimage-20220824161450-2.png"/}}[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_ac8ece9a26719fda.png||alt="image-20220824161450-2.png" height="170" width="401"]]180 +[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_ac8ece9a26719fda.png||alt="image-20220824161450-2.png" height="170" width="401"]] 182 182 183 -== {{id name="HS7-1200A0Ethernet"/}}**S7-1200 Ethernet ** ==182 +== **S7-1200 Ethernet ** == 184 184 185 185 [[download link>>url:https://ftp.we-con.com.cn/Download/WIKI/V-BOX/Demo/%E9%80%9A%E8%AE%AF%E6%A1%88%E4%BE%8B/Communicate%20with%20S7-1200%20via%20Ehernet.zip]] 186 186 186 +**V-BOX Setting** 187 + 188 +|**Items**|**Settings**|**Note** 189 +|Protocol|Siemens S7-1200| 190 +|Connection|Ethernet| 191 +|Port No.|102| 192 +|PLC station No.|2| 193 + 194 +**Address List** 195 + 196 +|**Type**|**Device register**|**HMI register**|**Format**|**Range**|**Note** 197 +|(% rowspan="4" %)Bit|I|I|M d.o|((( 198 +d:0~-~-9999 199 + 200 +o:0-7 201 +)))| 202 +|Q|Q|Q d.o|((( 203 +d:0~-~-9999 204 + 205 +o:0-7 206 +)))| 207 +|M|M|M d.o|((( 208 +d:0~-~-9999 209 + 210 +o:0-7 211 +)))| 212 +|DB0.DB-DB99.DB|DBxDB|DBxDBnndddd.o|((( 213 +nn:0-9999, 214 + 215 +dddd:0-9999, 216 + 217 +o:0-7 218 +)))|((( 219 +nn:DB No. 220 + 221 +dddd:address value 222 + 223 +o: digit address 224 +))) 225 +|(% rowspan="8" %)Word|M|MB|MB d|d:0-99999| 226 +|M|MW|MW d|d:0-99999|((( 227 +MW0=MB(0~~1) 228 + 229 +MW2=MB(2~~3) 230 + 231 +Address value is a multiple of 2 232 +))) 233 +|M|MD|MD d|d:0-99999|((( 234 +MD0=MB(0~~3) 235 + 236 +MD4=MB(4~~7) 237 + 238 +Address value is a multiple of 4 239 +))) 240 +|I|IW|IW d|d:0-99999| 241 +|Q|QW|QW d|d:0-99999| 242 +|DB0.DB-DB99.DB|DBxDBB|DBxDBBnndddd|((( 243 +nn:0-9999 244 + 245 +dddd:0-9999 246 +)))|((( 247 +nn:DB No. 248 + 249 +dddd:address value 250 +))) 251 +|DB0.DB-DB99.DB|DBxDBW|DBxDBWnndddd|((( 252 +nn:0-9999 253 + 254 +dddd:0-9999 255 +)))|((( 256 +nn:DB No. 257 + 258 +dddd:address value 259 + 260 +Address value is a multiple of 2 261 +))) 262 +|DB0.DB-DB99.DB|DBxDBD|DBxDBDnndddd|((( 263 +nn:0-9999 264 + 265 +dddd:0-9999 266 +)))|((( 267 +nn:DB No. 268 + 269 +dddd:address value 270 + 271 +Address value is a multiple of 4 272 +))) 273 + 274 +**Communication Settings** 275 + 276 +Enable HMI Ethernet in [Project Settings] 277 + 187 187 == **S7-XXX Ethernet** == 188 188 189 189 Supported Series: Siemens S7-400, S7-1200 and S7-1500 190 190 191 -** 1)V-BOX setting**282 +**V-BOX setting** 192 192 193 193 |=**Items**|=**Settings**|=**Note** 194 194 |Protocol|Siemens S7-XXX| ... ... @@ -201,29 +201,29 @@ 201 201 202 202 Rack from TIA Portal is equal to HMI No. of V-net 203 203 204 - {{id name="Iimage-20220824162459-3.png"/}}[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_d78bc267e5fc6394.png||alt="image-20220824162459-3.png" height="503" width="798"]]295 +[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_d78bc267e5fc6394.png||alt="image-20220824162459-3.png" height="503" width="798"]] 205 205 206 - {{id name="Iimage-20220824163305-2.png"/}}[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_c9ae84ef5d418580.png||alt="image-20220824163305-2.png" height="1009" width="1920"]]297 +[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_c9ae84ef5d418580.png||alt="image-20220824163305-2.png" height="1009" width="1920"]] 207 207 208 -** 2)Address List**299 +**Address List** 209 209 210 -|**Type**|**Device register**|** HMI register**|**Format**|**Range**|**Note**211 -|(% rowspan="4" %)Bit|I| I|M d.o|(((301 +|**Type**|**Device register**|**Format**|**Range**|**Note** 302 +|(% rowspan="4" %)Bit|I|M d.o|((( 212 212 d:0~-~-9999 213 213 214 214 o:0-7 215 215 )))| 216 -|Q|Q |Qd.o|(((307 +|Q|Q d.o|((( 217 217 d:0~-~-9999 218 218 219 219 o:0-7 220 220 )))| 221 -|M|M |Md.o|(((312 +|M|M d.o|((( 222 222 d:0~-~-9999 223 223 224 224 o:0-7 225 225 )))| 226 -|DB0.DB-DB99.DB|DBxDB |DBxDBnndddd.o|(((317 +|DB0.DB-DB99.DB|DBxDBnndddd.o|((( 227 227 nn:0-9999, 228 228 229 229 dddd:0-9999, ... ... @@ -236,8 +236,8 @@ 236 236 237 237 o: digit address 238 238 ))) 239 -|(% rowspan="8" %)Word|M|MB |MBd|d:0-99999|240 -|M|MW |MWd|d:0-99999|(((330 +|(% rowspan="8" %)Word|M|MB d|d:0-99999| 331 +|M|MW d|d:0-99999|((( 241 241 MW0=MB(0~~1) 242 242 243 243 MW2=MB(2~~3) ... ... @@ -244,7 +244,7 @@ 244 244 245 245 Address value is a multiple of 2 246 246 ))) 247 -|M|MD |MDd|d:0-99999|(((338 +|M|MD d|d:0-99999|((( 248 248 MD0=MB(0~~3) 249 249 250 250 MD4=MB(4~~7) ... ... @@ -251,9 +251,9 @@ 251 251 252 252 Address value is a multiple of 4 253 253 ))) 254 -|I|IW |IWd|d:0-99999|255 -|Q|QW |QWd|d:0-99999|256 -|DB0.DB-DB99.DB|DBxDBB |DBxDBBnndddd|(((345 +|I|IW d|d:0-99999| 346 +|Q|QW d|d:0-99999| 347 +|DB0.DB-DB99.DB|DBxDBBnndddd|((( 257 257 nn:0-9999 258 258 259 259 dddd:0-9999 ... ... @@ -262,7 +262,7 @@ 262 262 263 263 dddd:address value 264 264 ))) 265 -|DB0.DB-DB99.DB|DBxDBW |DBxDBWnndddd|(((356 +|DB0.DB-DB99.DB|DBxDBWnndddd|((( 266 266 nn:0-9999 267 267 268 268 dddd:0-9999 ... ... @@ -273,7 +273,7 @@ 273 273 274 274 Address value is a multiple of 2 275 275 ))) 276 -|DB0.DB-DB99.DB|DBxDBD |DBxDBDnndddd|(((367 +|DB0.DB-DB99.DB|DBxDBDnndddd|((( 277 277 nn:0-9999 278 278 279 279 dddd:0-9999 ... ... @@ -285,9 +285,9 @@ 285 285 Address value is a multiple of 4 286 286 ))) 287 287 288 -** 3)Configure the communication protocol**379 +**Configure the communication protocol** 289 289 290 - {{id name="Iimage-20220824163448-3.png"/}}[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_9e740a8bf83ea3bf.png||alt="image-20220824163448-3.png" height="557" width="974"]]381 +[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_9e740a8bf83ea3bf.png||alt="image-20220824163448-3.png" height="557" width="974"]] 291 291 292 292 **✎Note:** 293 293 ... ... @@ -294,9 +294,9 @@ 294 294 * The S7-1200 supports simultaneous connection of three devices, so the driver supports simultaneous access to PLC by three V-BOX. 295 295 * V-BOX access PLC, use S7 protocol, access PLC TSAP 02.01 (s7-1200 PROFINET interface only supports three connections, the default support), detailed reference to the system manual of S7-1200. 296 296 297 -** 4)Cable Wiring**388 +**Cable Wiring** 298 298 299 - {{id name="Iimage-20220824162342-2.png"/}}[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_ac8ece9a26719fda.png||alt="image-20220824162342-2.png" height="170" width="401"]]390 +[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_ac8ece9a26719fda.png||alt="image-20220824162342-2.png" height="170" width="401"]] 300 300 301 301 == {{id name="HLOGOEthernet"/}}**LOGO Ethernet ** == 302 302
- 1697099618537-157.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.AiXia - Size
-
... ... @@ -1,0 +1,1 @@ 1 +36.4 KB - Content