Changes for page Siemens

Last modified by Joe on 2024/08/30 14:46

From version 39.1
edited by Theodore Xu
on 2023/09/15 11:58
Change comment: There is no comment for this version
To version 40.1
edited by Theodore Xu
on 2023/09/15 11:58
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -137,19 +137,19 @@
137 137  
138 138  **2)Address List**
139 139  
140 -|**Type**|**Device register**|**HMI register**|**Format**|**Range**|**Note**
141 -|(% rowspan="4" %)Bit|I|I|I ddddd.o|0.0~~99999.7|
142 -|Q|Q|Q ddddd.o|0.0~~99999.7|
143 -|M|M|M ddddd.o|0.0~~99999.7|
144 -|DB0.DB~~DB99.DB|DBxDBD|DBxDB nndddd.o|0.0~~99999999.7|(((
140 +|**Type**|**Device register**|**Format**|**Range**|**Note**
141 +|(% rowspan="4" %)Bit|I|I ddddd.o|0.0~~99999.7|
142 +|Q|Q ddddd.o|0.0~~99999.7|
143 +|M|M ddddd.o|0.0~~99999.7|
144 +|DB0.DB~~DB99.DB|DBxDB nndddd.o|0.0~~99999999.7|(((
145 145  nn: block number;
146 146  
147 147  dddd: address;
148 148  )))
149 -|(% rowspan="8" %)Word|I|IW|IW ddddd|0~~99999|
150 -|Q|QW|QW ddddd|0~~99999|
151 -|(% rowspan="3" %)M|MB|MB ddddd|0~~99999|
152 -|MW|MW ddddd|0~~99999|(((
149 +|(% rowspan="8" %)Word|I|IW ddddd|0~~99999|
150 +|Q|QW ddddd|0~~99999|
151 +|(% rowspan="3" %)M|MB ddddd|0~~99999|
152 +|MW ddddd|0~~99999|(((
153 153  MW0=MB(0~~1)
154 154  
155 155  MW2=MB(2~~3)
... ... @@ -156,7 +156,7 @@
156 156  
157 157  Address value is a multiple of 2
158 158  )))
159 -|MD|MD ddddd|0~~99999|(((
159 +|MD ddddd|0~~99999|(((
160 160  MD0=MB(0~~3)
161 161  
162 162  MD4=MB(4~~7)
... ... @@ -163,13 +163,13 @@
163 163  
164 164  Address value is a multiple of 4
165 165  )))
166 -|(% rowspan="3" %)DB0.DB~~DB99.DB|DBxDBB|DBxDBB nndddd|0~~99999999|(% rowspan="3" %)(((
166 +|(% rowspan="3" %)DB0.DB~~DB99.DB|DBxDBB nndddd|0~~99999999|(% rowspan="3" %)(((
167 167  nn: block number;
168 168  
169 169  dddd: address
170 170  )))
171 -|DBxDBW|DBxDBW nndddd|0~~99999999
172 -|DBxDBD|DBxDBD nndddd|0~~99999999
171 +|DBxDBW nndddd|0~~99999999
172 +|DBxDBD nndddd|0~~99999999
173 173  
174 174  **3)Configure the communication protocol**
175 175